메뉴 건너뛰기




Volumn 16, Issue 1, 2015, Pages

Mechanical properties of orthodontic wires derived by instrumented indentation testing (IIT) according to ISO 14577

Author keywords

[No Author keywords available]

Indexed keywords

MOLYBDENUM; STAINLESS STEEL; TITANIUM; ALLOY; DENTAL ALLOY; NICKEL; TITANIUM MOLYBDENUM ALLOY; TITANIUM NICKELIDE;

EID: 84982791303     PISSN: 17237785     EISSN: 21961042     Source Type: Journal    
DOI: 10.1186/s40510-015-0091-z     Document Type: Article
Times cited : (27)

References (26)
  • 1
    • 0024710605 scopus 로고
    • Mechanical properties and clinical applications of orthodontic wires
    • PID: 2667330
    • Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop. 1989;96(2):100–9.
    • (1989) Am J Orthod Dentofacial Orthop , vol.96 , Issue.2 , pp. 100-109
    • Kapila, S.1    Sachdeva, R.2
  • 3
    • 79959986984 scopus 로고    scopus 로고
    • Comparisons of nanoindentation, 3-point bending, and tension tests for orthodontic wires
    • PID: 21724089
    • Iijima M, Muguruma T, Brantley WA, Mizoguchi I. Comparisons of nanoindentation, 3-point bending, and tension tests for orthodontic wires. Am J Orthod Dentofacial Orthop. 2011;140(1):65–71.
    • (2011) Am J Orthod Dentofacial Orthop , vol.140 , Issue.1 , pp. 65-71
    • Iijima, M.1    Muguruma, T.2    Brantley, W.A.3    Mizoguchi, I.4
  • 4
    • 33749610845 scopus 로고    scopus 로고
    • In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires
    • PID: 17045145
    • Verstrynge A, Van Humbeeck J, Willems G. In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2006;130(4):460–70.
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , Issue.4 , pp. 460-470
    • Verstrynge, A.1    Van Humbeeck, J.2    Willems, G.3
  • 7
    • 67649380351 scopus 로고    scopus 로고
    • Nanoindentation of orthodontic archwires: the effect of decontamination and clinical use on hardness, elastic modulus and surface roughness
    • PID: 19476991
    • Alcock JP, Barbour ME, Sandy JR, Ireland AJ. Nanoindentation of orthodontic archwires: the effect of decontamination and clinical use on hardness, elastic modulus and surface roughness. Dent Mater. 2009;25(8):1039–43.
    • (2009) Dent Mater , vol.25 , Issue.8 , pp. 1039-1043
    • Alcock, J.P.1    Barbour, M.E.2    Sandy, J.R.3    Ireland, A.J.4
  • 8
    • 84858685774 scopus 로고    scopus 로고
    • Effect of coating on properties of esthetic orthodontic nickel-titanium wires
    • PID: 21827235
    • Iijima M, Muguruma T, Brantley W, Choe HC, Nakagaki S, Alapati SB, et al. Effect of coating on properties of esthetic orthodontic nickel-titanium wires. Angle Orthod. 2012;82(2):319–25.
    • (2012) Angle Orthod , vol.82 , Issue.2 , pp. 319-325
    • Iijima, M.1    Muguruma, T.2    Brantley, W.3    Choe, H.C.4    Nakagaki, S.5    Alapati, S.B.6
  • 9
    • 84255177478 scopus 로고    scopus 로고
    • Effect of soft drinks on the physical and chemical features of nickel-titanium-based orthodontic wires
    • PID: 21492062
    • Parenti SI, Guicciardi S, Melandri C, Sprio S, Lafratta E, Tampieri A, et al. Effect of soft drinks on the physical and chemical features of nickel-titanium-based orthodontic wires. Acta Odontol Scand. 2012;70(1):49–55.
    • (2012) Acta Odontol Scand , vol.70 , Issue.1 , pp. 49-55
    • Parenti, S.I.1    Guicciardi, S.2    Melandri, C.3    Sprio, S.4    Lafratta, E.5    Tampieri, A.6
  • 10
    • 84893796963 scopus 로고    scopus 로고
    • Effect of surface roughness in the determination of the mechanical properties of material using nanoindentation test
    • PID: 23835928
    • Xia Y, Bigerelle M, Marteau J, Mazeran PE, Bouvier S, Iost A. Effect of surface roughness in the determination of the mechanical properties of material using nanoindentation test. Scanning. 2014;36(1):134–49.
    • (2014) Scanning , vol.36 , Issue.1 , pp. 134-149
    • Xia, Y.1    Bigerelle, M.2    Marteau, J.3    Mazeran, P.E.4    Bouvier, S.5    Iost, A.6
  • 11
    • 84982813509 scopus 로고    scopus 로고
    • Material property data. Date Accessed: 24-March-2014 [database on the Internet]. Available from:. Accessed: 24-03-2014
    • Material property data. www.matweb.com Date Accessed: 24-March-2014 [database on the Internet]. Available from: www.matweb.com. Accessed: 24-03-2014
  • 13
    • 58849103921 scopus 로고    scopus 로고
    • Structure, composition, and mechanical properties of Australian orthodontic wires
    • PID: 19123699
    • Pelsue BM, Zinelis S, Bradley TG, Berzins DW, Eliades T, Eliades G. Structure, composition, and mechanical properties of Australian orthodontic wires. Angle Orthod. 2009;79(1):97–101.
    • (2009) Angle Orthod , vol.79 , Issue.1 , pp. 97-101
    • Pelsue, B.M.1    Zinelis, S.2    Bradley, T.G.3    Berzins, D.W.4    Eliades, T.5    Eliades, G.6
  • 14
    • 84982846199 scopus 로고    scopus 로고
    • Stainless Steel Grade 310 MoLN (UNS S31050). Available from:. Accessed 8-4-2015
    • Stainless Steel Grade 310 MoLN (UNS S31050). Available from: http://www.azom.com/article.aspx?ArticleID=8281. Accessed 8-4-2015
  • 15
    • 0033208653 scopus 로고    scopus 로고
    • An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires
    • PID: 10515141
    • Hunt NP, Cunningham SJ, Golden CG, Sheriff M. An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires. Angle Orthod. 1999;69(5):433–40.
    • (1999) Angle Orthod , vol.69 , Issue.5 , pp. 433-440
    • Hunt, N.P.1    Cunningham, S.J.2    Golden, C.G.3    Sheriff, M.4
  • 16
    • 84891639211 scopus 로고    scopus 로고
    • Friction coefficients and wear rates of different orthodontic archwires in artificial saliva
    • PID: 23440428
    • Alfonso MV, Espinar E, Llamas JM, Ruperez E, Manero JM, Barrera JM, et al. Friction coefficients and wear rates of different orthodontic archwires in artificial saliva. J Mater Sci Mater Med. 2013;24(5):1327–32.
    • (2013) J Mater Sci Mater Med , vol.24 , Issue.5 , pp. 1327-1332
    • Alfonso, M.V.1    Espinar, E.2    Llamas, J.M.3    Ruperez, E.4    Manero, J.M.5    Barrera, J.M.6
  • 17
    • 34447618582 scopus 로고    scopus 로고
    • Micro-XRD study of beta-titanium wires and infrared soldered joints
    • PID: 17178150
    • Iijima M, Brantley WA, Baba N, Alapati SB, Yuasa T, Ohno H, et al. Micro-XRD study of beta-titanium wires and infrared soldered joints. Dent Mater. 2007;23(9):1051–6.
    • (2007) Dent Mater , vol.23 , Issue.9 , pp. 1051-1056
    • Iijima, M.1    Brantley, W.A.2    Baba, N.3    Alapati, S.B.4    Yuasa, T.5    Ohno, H.6
  • 19
    • 33644997274 scopus 로고    scopus 로고
    • Structure and wear properties of laser gas nitrided NiTi surface
    • Zhao N, Man H, Cui Z, Yang X. Structure and wear properties of laser gas nitrided NiTi surface. Surf Coat Tech. 2006;200:4879–84.
    • (2006) Surf Coat Tech , vol.200 , pp. 4879-4884
    • Zhao, N.1    Man, H.2    Cui, Z.3    Yang, X.4
  • 20
    • 34447627862 scopus 로고    scopus 로고
    • Hardness measured with traditional Vickers and Martens hardness methods
    • PID: 17141860
    • Shahdad SA, McCabe JF, Bull S, Rusby S, Wassell RW. Hardness measured with traditional Vickers and Martens hardness methods. Dent Mater. 2007;23(9):1079–85.
    • (2007) Dent Mater , vol.23 , Issue.9 , pp. 1079-1085
    • Shahdad, S.A.1    McCabe, J.F.2    Bull, S.3    Rusby, S.4    Wassell, R.W.5
  • 21
    • 74349101470 scopus 로고    scopus 로고
    • A metallurgical characterization of ten endodontic Ni-Ti instruments: assessing the clinical relevance of shape memory and superelastic properties of Ni-Ti endodontic instruments
    • PID: 20078701
    • Zinelis S, Eliades T, Eliades G. A metallurgical characterization of ten endodontic Ni-Ti instruments: assessing the clinical relevance of shape memory and superelastic properties of Ni-Ti endodontic instruments. Int Endod J. 2010;43(2):125–34.
    • (2010) Int Endod J , vol.43 , Issue.2 , pp. 125-134
    • Zinelis, S.1    Eliades, T.2    Eliades, G.3
  • 23
    • 0026871106 scopus 로고
    • Super-elasticity and thermal behavior of Ni-Ti alloy orthodontic arch wires
    • PID: 1395482
    • Yoneyama T, Doi H, Hamanaka H, Okamoto Y, Mogi M, Miura F. Super-elasticity and thermal behavior of Ni-Ti alloy orthodontic arch wires. Dent Mater J. 1992;11(1):1–10.
    • (1992) Dent Mater J , vol.11 , Issue.1 , pp. 1-10
    • Yoneyama, T.1    Doi, H.2    Hamanaka, H.3    Okamoto, Y.4    Mogi, M.5    Miura, F.6
  • 24
    • 0032500440 scopus 로고    scopus 로고
    • A new method for estimating residual stresses by instrumented sharp indentation
    • Suresh S, Giannakopoulos E. A new method for estimating residual stresses by instrumented sharp indentation. Acta Metal. 1998;46:5575–767.
    • (1998) Acta Metal , vol.46 , pp. 5575-5767
    • Suresh, S.1    Giannakopoulos, E.2
  • 25
    • 33846785050 scopus 로고    scopus 로고
    • Determination of mechanical properties by instrumented indentation
    • Mencik J. Determination of mechanical properties by instrumented indentation. Meccanica. 2007;42:19–29.
    • (2007) Meccanica , vol.42 , pp. 19-29
    • Mencik, J.1
  • 26
    • 84866035121 scopus 로고    scopus 로고
    • Nanostructured β-phase Ti-31.0Fe-9.0Sn and sub-micron structured Ti-39.3Nb-13.3Zr-10.7Ta alloys for biomedical applications: microstructure benefits on the mechanical and corrosion performances
    • Hynowska A, Pellicer E, Fornell J, Gonzalez S, Van Steenberge N, Surinach S, et al. Nanostructured β-phase Ti-31.0Fe-9.0Sn and sub-micron structured Ti-39.3Nb-13.3Zr-10.7Ta alloys for biomedical applications: microstructure benefits on the mechanical and corrosion performances. Mat Sci Eng C. 2012;32(8):2418–25.
    • (2012) Mat Sci Eng C , vol.32 , Issue.8 , pp. 2418-2425
    • Hynowska, A.1    Pellicer, E.2    Fornell, J.3    Gonzalez, S.4    Van Steenberge, N.5    Surinach, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.