메뉴 건너뛰기




Volumn 9786, Issue , 2016, Pages

Kinect based real-time position calibration for nasal endoscopic surgical navigation system

Author keywords

Calibration; Kinect; Nasal Endoscope; Registration; Surgical Navigation

Indexed keywords

ALGORITHMS; CALIBRATION; ENDOSCOPY; MEDICAL IMAGING; NAVIGATION SYSTEMS; ROBOTICS; SURGERY; SURGICAL EQUIPMENT; TRACKING (POSITION);

EID: 84982105582     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.2216599     Document Type: Conference Paper
Times cited : (1)

References (18)
  • 1
    • 79952114750 scopus 로고    scopus 로고
    • Recent advances in visualization, imaging, navigation in hepatobiliary and pancreatic sciences
    • M. Sugimoto, "Recent advances in visualization, imaging, navigation in hepatobiliary and pancreatic sciences," Journal of hepato-biliary-pancreatic sciences, vol. 17, pp. 574-576, 2010.
    • (2010) Journal of Hepato-biliary-pancreatic Sciences , vol.17 , pp. 574-576
    • Sugimoto, M.1
  • 2
    • 80051872997 scopus 로고    scopus 로고
    • Augmented reality in laparoscopic surgical oncology
    • S. Nicolau, L. Soler, D. Mutter, J. Marescaux, "Augmented reality in laparoscopic surgical oncology," Surgical oncology, vol. 20, pp. 189-201, 2011.
    • (2011) Surgical Oncology , vol.20 , pp. 189-201
    • Nicolau, S.1    Soler, L.2    Mutter, D.3    Marescaux, J.4
  • 3
    • 84939274436 scopus 로고    scopus 로고
    • Clinical application of navigation surgery using augmented reality in the abdominal field
    • T. Okamoto, S. Onda, K. Yanaga, N. Suzuki, A. Hattori, "Clinical application of navigation surgery using augmented reality in the abdominal field," Surgery today, pp. 1-10, 2014.
    • (2014) Surgery Today , pp. 1-10
    • Okamoto, T.1    Onda, S.2    Yanaga, K.3    Suzuki, N.4    Hattori, A.5
  • 4
    • 84880207869 scopus 로고    scopus 로고
    • Magnetic navigation for thoracic aortic stent-graft deployment using ultrasound image guidance
    • Z. Luo, J. Cai, S. Wang, Q. Zhao, T. M. Peters, L. Gu, "Magnetic navigation for thoracic aortic stent-graft deployment using ultrasound image guidance," IEEE Trans. Biomedical Engineering, vol. 60, pp. 862-871, 2013.
    • (2013) IEEE Trans. Biomedical Engineering , vol.60 , pp. 862-871
    • Luo, Z.1    Cai, J.2    Wang, S.3    Zhao, Q.4    Peters, T.M.5    Gu, L.6
  • 5
    • 84876463712 scopus 로고    scopus 로고
    • Neuronavigation in endonasal pituitary and skull base surgery using an autoregistration mask without head fixation: An assessment of accuracy and practicality
    • N. McLaughlin, R. L. Carrau, A. B. Kassam, D. F. Kelly, "Neuronavigation in endonasal pituitary and skull base surgery using an autoregistration mask without head fixation: an assessment of accuracy and practicality," Journal of neurological surgery. Part A, Central European neurosurgery, vol. 73, pp. 351-357, 2012.
    • (2012) Journal of Neurological Surgery. Part A, Central European Neurosurgery , vol.73 , pp. 351-357
    • McLaughlin, N.1    Carrau, R.L.2    Kassam, A.B.3    Kelly, D.F.4
  • 6
  • 7
    • 77952554970 scopus 로고    scopus 로고
    • 3-D Augmented Reality for MRI-Guided surgery using integral videography autostereoscopic image overlay
    • L. Hongen, T. Inomata, I. Sakuma, T. Dohi, "3-D Augmented Reality for MRI-Guided Surgery Using Integral Videography Autostereoscopic Image Overlay," IEEE Trans. Biomedical Engineering, vol. 57, pp. 1476-1486, 2010.
    • (2010) IEEE Trans. Biomedical Engineering , vol.57 , pp. 1476-1486
    • Hongen, L.1    Inomata, T.2    Sakuma, I.3    Dohi, T.4
  • 8
    • 67149121177 scopus 로고    scopus 로고
    • High-performance intraoperative cone-beam CT on a mobile C-arm: An integrated system for guidance of head and neck surgery
    • J. Siewerdsen, M. Daly, H. Chan, S. Nithiananthan, N. Hamming, K. Brock, et al., "High-performance intraoperative cone-beam CT on a mobile C-arm: an integrated system for guidance of head and neck surgery," in SPIE Medical Imaging, 2009, pp. 72610J-72610J-8.
    • (2009) SPIE Medical Imaging , pp. 72610J-72610J8
    • Siewerdsen, J.1    Daly, M.2    Chan, H.3    Nithiananthan, S.4    Hamming, N.5    Brock, K.6
  • 9
    • 67349149999 scopus 로고    scopus 로고
    • An augmented reality system for liver thermal ablation: Design and evaluation on clinical cases
    • S. Nicolau, X. Pennec, L. Soler, X. Buy, A. Gangi, N. Ayache, et al., "An augmented reality system for liver thermal ablation: design and evaluation on clinical cases," Medical Image Analysis, vol. 13, pp. 494-506, 2009.
    • (2009) Medical Image Analysis , vol.13 , pp. 494-506
    • Nicolau, S.1    Pennec, X.2    Soler, L.3    Buy, X.4    Gangi, A.5    Ayache, N.6
  • 11
    • 84885187948 scopus 로고    scopus 로고
    • Navigation system for minimally invasive esophagectomy: Experimental study in a porcine model
    • F. Nickel, H. G. Kenngott, J. Neuhaus, C. M. Sommer, T. Gehrig, A. Kolb, et al., "Navigation system for minimally invasive esophagectomy: experimental study in a porcine model," Surgical endoscopy, vol. 27, pp. 3663-3670, 2013.
    • (2013) Surgical Endoscopy , vol.27 , pp. 3663-3670
    • Nickel, F.1    Kenngott, H.G.2    Neuhaus, J.3    Sommer, C.M.4    Gehrig, T.5    Kolb, A.6
  • 12
    • 84896546073 scopus 로고    scopus 로고
    • Augmented real?time navigation with critical structure proximity alerts for endoscopic skull base surgery
    • B. J. Dixon, M. J. Daly, H. Chan, A. Vescan, I. J. Witterick, J. C. Irish, "Augmented real?time navigation with critical structure proximity alerts for endoscopic skull base surgery," The Laryngoscope, vol. 124, pp. 853-859, 2014.
    • (2014) The Laryngoscope , vol.124 , pp. 853-859
    • Dixon, B.J.1    Daly, M.J.2    Chan, H.3    Vescan, A.4    Witterick, I.J.5    Irish, J.C.6
  • 16
    • 0026137964 scopus 로고
    • Least-squares estimation of transformation parameters between two point patterns
    • S. Umeyama, "Least-squares estimation of transformation parameters between two point patterns," IEEE Trans. Pattern Analysis and Machine Intelligence, vol. 13, pp. 376-380, 1991.
    • (1991) IEEE Trans. Pattern Analysis and Machine Intelligence , vol.13 , pp. 376-380
    • Umeyama, S.1
  • 17
    • 0023381475 scopus 로고
    • Marching cubes: A high resolution 3D surface construction algorithm
    • W. E. Lorensen and H. E. Cline, "Marching cubes: A high resolution 3D surface construction algorithm," in ACM Siggraph Computer Graphics, 1987, pp. 163-169.
    • (1987) ACM Siggraph Computer Graphics , pp. 163-169
    • Lorensen, W.E.1    Cline, H.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.