메뉴 건너뛰기




Volumn 22, Issue 8, 2016, Pages 631-636

Validation of a New Heart Rate Measurement Algorithm for Fingertip Recording of Video Signals with Smartphones

Author keywords

Cardiology; heart rate variability; m Health; pulse wave analysis; smartphone; video signal

Indexed keywords

ALGORITHMS; CARDIOLOGY; ELECTROCARDIOGRAPHY; FREQUENCY DOMAIN ANALYSIS; SIGNAL ENCODING; SMARTPHONES; VIDEO SIGNAL PROCESSING;

EID: 84981335358     PISSN: 15305627     EISSN: 15563669     Source Type: Journal    
DOI: 10.1089/tmj.2015.0212     Document Type: Article
Times cited : (48)

References (26)
  • 1
    • 0029988782 scopus 로고    scopus 로고
    • Task force of the european society of cardiology and the north American society of pacing and electrophysiology
    • Taskforce. Heart rate variability. Standards of measurement, physiological interpretation, and clinical use
    • Taskforce. Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Eur Heart J 1996;17:354-381
    • (1996) Eur Heart J , vol.17 , pp. 354-381
  • 2
    • 0034602826 scopus 로고    scopus 로고
    • Chaos theory, heart rate variability, and arrhythmic mortality
    • Lombardi F. Chaos theory, heart rate variability, and arrhythmic mortality. Circulation 2000;101:8-10
    • (2000) Circulation , vol.101 , pp. 8-10
    • Lombardi, F.1
  • 6
    • 0035039002 scopus 로고    scopus 로고
    • Heart rate variability measurement in diabetic neuropathy: Review of methods
    • Risk M, Bril V, Broadbridge C, Cohen A. Heart rate variability measurement in diabetic neuropathy: Review of methods. Diabetes Technol Ther 2001;3: 63-76
    • (2001) Diabetes Technol Ther , vol.3 , pp. 63-76
    • Risk, M.1    Bril, V.2    Broadbridge, C.3    Cohen, A.4
  • 7
    • 0028951502 scopus 로고
    • RR variability in healthy, middle-aged persons compared with patients with chronic coronary heart disease or recent acute myocardial infarction
    • Bigger Jr. JT, Fleiss JL, Steinman RC, Rolnitzky LM, Schneider WJ, Stein PK. RR variability in healthy, middle-aged persons compared with patients with chronic coronary heart disease or recent acute myocardial infarction. Circulation 1995;91:1936-1943
    • (1995) Circulation , vol.91 , pp. 1936-1943
    • Bigger, J.T.1    Fleiss, J.L.2    Steinman, R.C.3    Rolnitzky, L.M.4    Schneider, W.J.5    Stein, P.K.6
  • 8
    • 34548401617 scopus 로고    scopus 로고
    • Heart rate variability in acute coronary syndrome patients with major depression: Influence of sertraline and mood improvement
    • Glassman AH, Bigger JT, Gaffney M, Van Zyl LT. Heart rate variability in acute coronary syndrome patients with major depression: Influence of sertraline and mood improvement. Arch Gen Psychiatry 2007;64:1025-1031
    • (2007) Arch Gen Psychiatry , vol.64 , pp. 1025-1031
    • Glassman, A.H.1    Bigger, J.T.2    Gaffney, M.3    Van Zyl, L.T.4
  • 9
    • 79951728836 scopus 로고    scopus 로고
    • Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea
    • Khandoker AH, Karmakar CK, Palaniswami M. Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea. Med Eng Phys 2011;33:204-209
    • (2011) Med Eng Phys , vol.33 , pp. 204-209
    • Khandoker, A.H.1    Karmakar, C.K.2    Palaniswami, M.3
  • 10
    • 84877733859 scopus 로고    scopus 로고
    • How accurate is pulse rate variability as an estimate of heart rate variability?: A review on studies comparing photoplethysmographic technology with an electrocardiogram
    • Schäfer A, Vagedes J. How accurate is pulse rate variability as an estimate of heart rate variability?: A review on studies comparing photoplethysmographic technology with an electrocardiogram. Int J Cardiol 2013;166:15-29
    • (2013) J Cardiol , vol.166 , pp. 15-29
    • Schäfer, A.1    Vagedes, J.2
  • 11
    • 39949085790 scopus 로고    scopus 로고
    • Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information?
    • Lu S, Zhao H, Ju K, Shin K, Lee M, Shelley K, Chon KH. Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? J Clin Monit Comput 2008;22:23-29
    • (2008) J Clin Monit Comput , vol.22 , pp. 23-29
    • Lu, S.1    Zhao, H.2    Ju, K.3    Shin, K.4    Lee, M.5    Shelley, K.6    Chon, K.H.7
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1(8476):307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 84895507457 scopus 로고    scopus 로고
    • Validity of the Ithlete smart phone application for determining ultra-short-term heart rate variability
    • Flatt AA, Esco MR. Validity of the Ithlete smart phone application for determining ultra-short-term heart rate variability. J Hum Kinet 2013;39:85-92
    • (2013) J Hum Kinet , vol.39 , pp. 85-92
    • Flatt, A.A.1    Esco, M.R.2
  • 16
    • 84977863765 scopus 로고    scopus 로고
    • Extracting heart rate variability from a smartphone camera
    • Lenskiy AA, Aitzhan Y. Extracting heart rate variability from a smartphone camera. J Inf Commun Converg Eng 2013;11:216-222
    • (2013) J Inf Commun Converg Eng , vol.11 , pp. 216-222
    • Lenskiy, A.A.1    Aitzhan, Y.2
  • 18
    • 84881394626 scopus 로고    scopus 로고
    • Statistical analysis of heart rate and heart rate variability monitoring through the use of smart phone cameras
    • Bolkhovsky JB, Scully CG, Chon KH. Statistical analysis of heart rate and heart rate variability monitoring through the use of smart phone cameras. Conf Proc IEEE Eng Med Biol Soc 2012;2012:1610-1613
    • (2012) Conf Proc IEEE Eng Med Biol Soc , vol.2012 , pp. 1610-1613
    • Bolkhovsky, J.B.1    Scully, C.G.2    Chon, K.H.3
  • 19
    • 84880942977 scopus 로고    scopus 로고
    • Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone
    • Kwon S, Kim H, Park KS. Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone. Proc Annu Int Conf IEEE Eng Med Biol Soc 2012;2012:2174-2177
    • (2012) Proc Annu Int Conf IEEE Eng Med Biol Soc , vol.2012 , pp. 2174-2177
    • Kwon, S.1    Kim, H.2    Park, K.S.3
  • 22
    • 70350439728 scopus 로고    scopus 로고
    • A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects
    • Lu G, Yang F, Taylor JA, Stein JF. A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects. J Med Eng Technol 2009;33:634-641
    • (2009) J Med Eng Technol , vol.33 , pp. 634-641
    • Lu, G.1    Yang, F.2    Taylor, J.A.3    Stein, J.F.4
  • 23
    • 84947649470 scopus 로고    scopus 로고
    • Extraction of heart rate variability from smartphone photoplethysmograms
    • Peng R-C, Zhou X-L, Lin W-H, Zhang Y-T. Extraction of heart rate variability from smartphone photoplethysmograms. Comput Math Methods Med 2015;2015:1-11
    • (2015) Comput Math Methods Med , vol.2015 , pp. 1-11
    • Peng, R.-C.1    Zhou, X.-L.2    Lin, W.-H.3    Zhang, Y.-T.4
  • 25
    • 80355132660 scopus 로고    scopus 로고
    • Nonlinear heart rate variability features for reallife stress detection Case study: Students under stress due to university examination
    • Melillo P, Bracale M, Pecchia L. Nonlinear heart rate variability features for reallife stress detection. Case study: Students under stress due to university examination. Biomed Eng Online 2011;10:96
    • (2011) Biomed Eng Online , vol.10 , pp. 96
    • Melillo, P.1    Bracale, M.2    Pecchia, L.3
  • 26
    • 33750086628 scopus 로고    scopus 로고
    • Heart rate variability and physical exercise Current status
    • Hottenrott K, Hoos O, Esperer HD. [Heart rate variability and physical exercise. Current status]. Herz 2006;31:544-552
    • (2006) Herz , vol.31 , pp. 544-552
    • Hottenrott, K.1    Hoos, O.2    Esperer, H.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.