메뉴 건너뛰기




Volumn 166, Issue 1, 2013, Pages 15-29

How accurate is pulse rate variability as an estimate of heart rate variability?: A review on studies comparing photoplethysmographic technology with an electrocardiogram

Author keywords

Continuous blood pressure monitoring; Electrocardiography; Heart rate variability; Photoplethysmography; Pulse wave analysis

Indexed keywords

ACCURACY; AMBULATORY MONITORING; ARTIFACT; BLOOD PRESSURE MONITORING; BREATHING PATTERN; CARDIOVASCULAR PARAMETERS; ELECTROCARDIOGRAM; ELECTROCARDIOGRAPHY; HEART RATE VARIABILITY; HUMAN; IMPEDANCE PLETHYSMOGRAPHY; MENTAL STRESS; PHOTOELECTRIC PLETHYSMOGRAPH; PHOTOELECTRIC PLETHYSMOGRAPHY; PHYSICAL ACTIVITY; PRIORITY JOURNAL; PULSE OXIMETRY; PULSE RATE VARIABILITY; PULSE WAVE; QRS COMPLEX; REST; REVIEW; RR INTERVAL;

EID: 84877733859     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2012.03.119     Document Type: Review
Times cited : (492)

References (105)
  • 1
    • 0029928495 scopus 로고    scopus 로고
    • Electrophysiology TFotESoCatNASoP. Heart rate variability. Standards of measurement, physiological interpretation, and clinical use
    • Electrophysiology TFotESoCatNASoP. Heart rate variability. Standards of measurement, physiological interpretation, and clinical use Circulation 93 1996 1043 1065
    • (1996) Circulation , vol.93 , pp. 1043-1065
  • 2
    • 0023100673 scopus 로고
    • Decreased heart rate variability and its association with increased mortality after acute myocardial infarction
    • R.E. Kleiger, J.P. Miller, J.T. Bigger Jr., and A.J. Moss Decreased heart rate variability and its association with increased mortality after acute myocardial infarction Am J Cardiol 59 1987 256 262
    • (1987) Am J Cardiol , vol.59 , pp. 256-262
    • Kleiger, R.E.1    Miller, J.P.2    Bigger, Jr.J.T.3    Moss, A.J.4
  • 3
    • 0029828695 scopus 로고    scopus 로고
    • Impact of reduced heart rate variability on risk for cardiac events: The Framingham Heart Study
    • H. Tsuji, M.G. Larson, and F.J. Venditti Impact of reduced heart rate variability on risk for cardiac events: the Framingham Heart Study Circulation 94 1996 2850 2855
    • (1996) Circulation , vol.94 , pp. 2850-2855
    • Tsuji, H.1    Larson, M.G.2    Venditti, F.J.3
  • 4
    • 0032807515 scopus 로고    scopus 로고
    • Independent and incremental prognostic value of heart rate variability in patients with chronic heart failure
    • D. Bonaduce, M. Petretta, and F. Marciano Independent and incremental prognostic value of heart rate variability in patients with chronic heart failure Am Heart J 138 1999 273 284
    • (1999) Am Heart J , vol.138 , pp. 273-284
    • Bonaduce, D.1    Petretta, M.2    Marciano, F.3
  • 5
    • 0026216087 scopus 로고
    • Attenuated 24-h heart rate variability in apparently healthy subjects, subsequently suffering sudden cardiac death
    • H. Mølgaard, K.E. Sørensen, and P. Bjerregaard Attenuated 24-h heart rate variability in apparently healthy subjects, subsequently suffering sudden cardiac death Clin Auton Res 1 1991 233 237
    • (1991) Clin Auton Res , vol.1 , pp. 233-237
    • Mølgaard, H.1    Sørensen, K.E.2    Bjerregaard, P.3
  • 6
    • 0019827638 scopus 로고
    • Power spectrum analysis of heart rate fluctuation: A quantitative probe of beat-to-beat cardiovascular control
    • S. Akselrod, D. Gordon, F. Ubel, D. Shannon, A. Berger, and R. Cohen Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control Science 213 1981 220 222
    • (1981) Science , vol.213 , pp. 220-222
    • Akselrod, S.1    Gordon, D.2    Ubel, F.3    Shannon, D.4    Berger, A.5    Cohen, R.6
  • 9
  • 10
    • 0028006869 scopus 로고
    • The effect of amitriptyline, doxepin, fluvoxamine, and paroxetine treatment on heart rate variability
    • T. Rechlin The effect of amitriptyline, doxepin, fluvoxamine, and paroxetine treatment on heart rate variability J Clin Psychopharmacol 14 1994 392 395
    • (1994) J Clin Psychopharmacol , vol.14 , pp. 392-395
    • Rechlin, T.1
  • 11
    • 0028566121 scopus 로고
    • Are affective disorders associated with alterations of heart rate variability?
    • T. Rechlin, M. Weis, A. Spitzer, and W.P. Kaschka Are affective disorders associated with alterations of heart rate variability? J Affect Disord 32 1994 271 275
    • (1994) J Affect Disord , vol.32 , pp. 271-275
    • Rechlin, T.1    Weis, M.2    Spitzer, A.3    Kaschka, W.P.4
  • 12
    • 1542786647 scopus 로고    scopus 로고
    • Heart rate variability: Short-term studies are as useful as Holter to differentiate diabetic patients from healthy subjects
    • E.R. Migliaro, R. Canetti, P. Contreras, and M. Hakas Heart rate variability: short-term studies are as useful as Holter to differentiate diabetic patients from healthy subjects Ann Noninvasive Electrocardiol 8 2003 313 320
    • (2003) Ann Noninvasive Electrocardiol , vol.8 , pp. 313-320
    • Migliaro, E.R.1    Canetti, R.2    Contreras, P.3    Hakas, M.4
  • 13
    • 2442662543 scopus 로고    scopus 로고
    • Can cardiac vagal tone be estimated from the 10-second ECG?
    • R.M. Hamilton, P.S. McKechnie, and P.W. Macfarlane Can cardiac vagal tone be estimated from the 10-second ECG? Int J Cardiol 95 2004 109 115
    • (2004) Int J Cardiol , vol.95 , pp. 109-115
    • Hamilton, R.M.1    McKechnie, P.S.2    MacFarlane, P.W.3
  • 14
    • 0000126622 scopus 로고
    • Observations on the finger volume pulse recorded photoelectrically
    • A. Herzman, and C. Spielman Observations on the finger volume pulse recorded photoelectrically Am J Physiol 119 1937 334 335
    • (1937) Am J Physiol , vol.119 , pp. 334-335
    • Herzman, A.1    Spielman, C.2
  • 15
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • J. Allen Photoplethysmography and its application in clinical physiological measurement Physiol Meas 28 2007 R1
    • (2007) Physiol Meas , vol.28 , pp. 1
    • Allen, J.1
  • 17
    • 0344121909 scopus 로고    scopus 로고
    • Standard pulse oximeters can be used to monitor respiratory rate
    • P. Leonard, T.F. Beattie, P.S. Addison, and J.N. Watson Standard pulse oximeters can be used to monitor respiratory rate Emerg Med J 20 2003 524 525
    • (2003) Emerg Med J , vol.20 , pp. 524-525
    • Leonard, P.1    Beattie, T.F.2    Addison, P.S.3    Watson, J.N.4
  • 18
    • 43449105997 scopus 로고    scopus 로고
    • Photoplethysmography: Beyond the calculation of arterial oxygen saturation and heart rate
    • K. Shelley Photoplethysmography: Beyond the calculation of arterial oxygen saturation and heart rate Anesth Analg 105 2007 S31 S36
    • (2007) Anesth Analg , vol.105
    • Shelley, K.1
  • 20
    • 20944438037 scopus 로고    scopus 로고
    • Pulse transit time by R-wave-gated infrared photoplethysmography: Review of the literature and personal experience
    • J. Naschitz, S. Bezobchuk, and R. Mussafia-Priselac Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience J Clin Monit Comput 18 2004 333 342
    • (2004) J Clin Monit Comput , vol.18 , pp. 333-342
    • Naschitz, J.1    Bezobchuk, S.2    Mussafia-Priselac, R.3
  • 23
    • 0033404540 scopus 로고    scopus 로고
    • Photoplethysmographic assessment of pulse wave reflection: Blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus
    • P.J. Chowienczyk, R.P. Kelly, and H. MacCallum Photoplethysmographic assessment of pulse wave reflection: blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus J Am Coll Cardiol 34 1999 2007 2014
    • (1999) J Am Coll Cardiol , vol.34 , pp. 2007-2014
    • Chowienczyk, P.J.1    Kelly, R.P.2    MacCallum, H.3
  • 24
    • 0031910258 scopus 로고    scopus 로고
    • The variability of the photoplethysmographic signal - A potential method for the evaluation of the autonomic nervous system
    • M. Nitzan The variability of the photoplethysmographic signal - a potential method for the evaluation of the autonomic nervous system Physiol Meas 19 1998 93
    • (1998) Physiol Meas , vol.19 , pp. 93
    • Nitzan, M.1
  • 25
    • 0025763193 scopus 로고
    • Determination of pulse wave velocities with computerized algorithms
    • Y.C. Chiu, P.W. Arand, S.G. Shroff, T. Feldman, and J.D. Carroll Determination of pulse wave velocities with computerized algorithms Am Heart J 121 1991 1460 1470
    • (1991) Am Heart J , vol.121 , pp. 1460-1470
    • Chiu, Y.C.1    Arand, P.W.2    Shroff, S.G.3    Feldman, T.4    Carroll, J.D.5
  • 26
    • 78149474788 scopus 로고    scopus 로고
    • Mathematical methods for determining the foot point of the arterial pulse wave and evaluation of proposed methods
    • E. Kazanavicius, R.A.V. Gircys, and S. Lugin Mathematical methods for determining the foot point of the arterial pulse wave and evaluation of proposed methods Inf Technol Control 34 2005 29 36
    • (2005) Inf Technol Control , vol.34 , pp. 29-36
    • Kazanavicius, E.1    Gircys, R.A.V.2    Lugin, S.3
  • 28
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • L. Lin A concordance correlation coefficient to evaluate reproducibility Biometrics 45 1989 255 268
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.1
  • 29
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J. Bland, and D. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 327 1986 307 310
    • (1986) Lancet , vol.327 , pp. 307-310
    • Bland, J.1    Altman, D.2
  • 30
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • J.M. Bland, and D.G. Altman Comparing methods of measurement: why plotting difference against standard method is misleading Lancet 346 1995 1085 1087
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 31
    • 0022645103 scopus 로고
    • Pulse oximetry as a continuous, noninvasive monitoring procedure. Comparison of 2 instruments. (in German)
    • K.H. Altemeyer, J. Mayer, S. Berg-Seiter, and T. Fosel Pulse oximetry as a continuous, noninvasive monitoring procedure. Comparison of 2 instruments. (in German) Anaesthesist 35 1986 43 45
    • (1986) Anaesthesist , vol.35 , pp. 43-45
    • Altemeyer, K.H.1    Mayer, J.2    Berg-Seiter, S.3    Fosel, T.4
  • 32
    • 0023792446 scopus 로고
    • Evaluation of pulse oximetry as a continuous monitoring technique in the neonatal intensive care unit
    • K.J. Barrington, N.N. Finer, and C.A. Ryan Evaluation of pulse oximetry as a continuous monitoring technique in the neonatal intensive care unit Crit Care Med 16 1988 1147 1153
    • (1988) Crit Care Med , vol.16 , pp. 1147-1153
    • Barrington, K.J.1    Finer, N.N.2    Ryan, C.A.3
  • 33
    • 0033496737 scopus 로고    scopus 로고
    • Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique
    • A. Johansson, P.A. Oberg, and G. Sedin Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique J Clin Monit Comput 15 1999 461 467
    • (1999) J Clin Monit Comput , vol.15 , pp. 461-467
    • Johansson, A.1    Oberg, P.A.2    Sedin, G.3
  • 34
    • 0026674358 scopus 로고
    • Monitoring of respiratory and heart rates using a fibre-optic sensor
    • L. Lindberg, H. Ugnell, and P. Öberg Monitoring of respiratory and heart rates using a fibre-optic sensor Med Biol Eng Comput 30 1992 533 537
    • (1992) Med Biol Eng Comput , vol.30 , pp. 533-537
    • Lindberg, L.1    Ugnell, H.2    Öberg, P.3
  • 35
    • 0030199595 scopus 로고    scopus 로고
    • Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique
    • K. Nakajima, T. Tamura, and H. Miike Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique Med Eng Phys 18 1996 365 372
    • (1996) Med Eng Phys , vol.18 , pp. 365-372
    • Nakajima, K.1    Tamura, T.2    Miike, H.3
  • 37
    • 33749264824 scopus 로고    scopus 로고
    • The application of surface plethysmography for heart rate variability analysis after GSM radiofrequency exposure
    • T. Atlasz, L. Kellenyi, and P. Kovacs The application of surface plethysmography for heart rate variability analysis after GSM radiofrequency exposure J Biochem Biophys Methods 69 2006 233 236
    • (2006) J Biochem Biophys Methods , vol.69 , pp. 233-236
    • Atlasz, T.1    Kellenyi, L.2    Kovacs, P.3
  • 39
    • 43549084348 scopus 로고    scopus 로고
    • Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room
    • C.O.F. Kamlin, J.A. Dawson, and C.P.F. O'Donnell Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room J Pediatr 152 2008 756 760
    • (2008) J Pediatr , vol.152 , pp. 756-760
    • Kamlin, C.O.F.1    Dawson, J.A.2    O'Donnell, C.P.F.3
  • 41
    • 0033856887 scopus 로고    scopus 로고
    • Photoplethysmography for simultaneous recording of heart and respiratory rates in newborn infants
    • E. Olsson, H. Ugnell, P. Öberg, and G. Sedin Photoplethysmography for simultaneous recording of heart and respiratory rates in newborn infants Acta Paediatr 89 2000 853 861
    • (2000) Acta Paediatr , vol.89 , pp. 853-861
    • Olsson, E.1    Ugnell, H.2    Öberg, P.3    Sedin, G.4
  • 42
    • 0032170663 scopus 로고    scopus 로고
    • Comparison of the heart rate variability parameters obtained from the electrocardiogram and the blood pressure wave
    • S. Carrasco, R. Gonzalez, J. Jimenez, R. Roman, V. Medina, and J. Azpiroz Comparison of the heart rate variability parameters obtained from the electrocardiogram and the blood pressure wave J Med Eng Technol 22 1998 195 205
    • (1998) J Med Eng Technol , vol.22 , pp. 195-205
    • Carrasco, S.1    Gonzalez, R.2    Jimenez, J.3    Roman, R.4    Medina, V.5    Azpiroz, J.6
  • 43
    • 0032828520 scopus 로고    scopus 로고
    • Pulse rate variability is not a surrogate for heart rate variability
    • I. Constant, D. Laude, I. Murat, and J.L. Elghozi Pulse rate variability is not a surrogate for heart rate variability Clin Sci (Lond) 97 1999 391 397
    • (1999) Clin Sci (Lond) , vol.97 , pp. 391-397
    • Constant, I.1    Laude, D.2    Murat, I.3    Elghozi, J.L.4
  • 44
    • 0032439232 scopus 로고    scopus 로고
    • Should one use electrocardiographic or Finapres-derived pulse intervals for calculation of cardiac baroreceptor sensitivity?
    • S.L. Dawson, R.B. Panerai, and J.F. Potter Should one use electrocardiographic or Finapres-derived pulse intervals for calculation of cardiac baroreceptor sensitivity? Blood Press Monit 3 1998 315 320
    • (1998) Blood Press Monit , vol.3 , pp. 315-320
    • Dawson, S.L.1    Panerai, R.B.2    Potter, J.F.3
  • 46
    • 0141567913 scopus 로고    scopus 로고
    • Deriving heart period variability from blood pressure waveforms
    • P.S. McKinley, P.A. Shapiro, and E. Bagiella Deriving heart period variability from blood pressure waveforms J Appl Physiol 95 2003 1431 1438
    • (2003) J Appl Physiol , vol.95 , pp. 1431-1438
    • McKinley, P.S.1    Shapiro, P.A.2    Bagiella, E.3
  • 47
    • 33747256249 scopus 로고    scopus 로고
    • Comparison of three methods for beat-to-beat-interval extraction from continuous blood pressure and electrocardiogram with respect to heart rate variability analysis
    • A. Suhrbier, R. Heringer, T. Walther, H. Malberg, and N. Wessel Comparison of three methods for beat-to-beat-interval extraction from continuous blood pressure and electrocardiogram with respect to heart rate variability analysis Biomed Tech (Berl) 51 2006 70 76
    • (2006) Biomed Tech (Berl) , vol.51 , pp. 70-76
    • Suhrbier, A.1    Heringer, R.2    Walther, T.3    Malberg, H.4    Wessel, N.5
  • 48
    • 27744500272 scopus 로고    scopus 로고
    • Design and evaluation of a handheld impedance plethysmograph for measuring heart rate variability
    • N.K. Kristiansen, J. Fleischer, M.S. Jensen, K.S. Andersen, and H. Nygaard Design and evaluation of a handheld impedance plethysmograph for measuring heart rate variability Med Biol Eng Comput 43 2005 516 521
    • (2005) Med Biol Eng Comput , vol.43 , pp. 516-521
    • Kristiansen, N.K.1    Fleischer, J.2    Jensen, M.S.3    Andersen, K.S.4    Nygaard, H.5
  • 49
    • 26844569769 scopus 로고    scopus 로고
    • Algorithm for identifying and separating beats from arterial pulse records
    • E.F. Treo, M.C. Herrera, and M.E. Valentinuzzi Algorithm for identifying and separating beats from arterial pulse records Biomed Eng Online 4 2005 48
    • (2005) Biomed Eng Online , vol.4 , pp. 48
    • Treo, E.F.1    Herrera, M.C.2    Valentinuzzi, M.E.3
  • 51
    • 0025323306 scopus 로고
    • Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability
    • M. Merri, D.C. Farden, J.G. Mottley, and E.L. Titlebaum Sampling frequency of the electrocardiogram for spectral analysis of the heart rate variability Biomed Eng IEEE Trans 37 1990 99 106
    • (1990) Biomed Eng IEEE Trans , vol.37 , pp. 99-106
    • Merri, M.1    Farden, D.C.2    Mottley, J.G.3    Titlebaum, E.L.4
  • 52
    • 0036201116 scopus 로고    scopus 로고
    • Comparison of finger plethysmograph to ECG in the measurement of heart rate variability
    • N.D. Giardino, P.M. Lehrer, and R. Edelberg Comparison of finger plethysmograph to ECG in the measurement of heart rate variability Psychophysiology 39 2002 246 253
    • (2002) Psychophysiology , vol.39 , pp. 246-253
    • Giardino, N.D.1    Lehrer, P.M.2    Edelberg, R.3
  • 53
    • 56249102489 scopus 로고    scopus 로고
    • Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography
    • N. Selvaraj, A. Jaryal, J. Santhosh, K.K. Deepak, and S. Anand Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography J Med Eng Technol 32 2008 479 484
    • (2008) J Med Eng Technol , vol.32 , pp. 479-484
    • Selvaraj, N.1    Jaryal, A.2    Santhosh, J.3    Deepak, K.K.4    Anand, S.5
  • 54
    • 60849133658 scopus 로고    scopus 로고
    • A preliminary attempt to understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability
    • P. Shi, S. Hu, and Y. Zhu A preliminary attempt to understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability J Med Biol Eng 28 2008 173 180
    • (2008) J Med Biol Eng , vol.28 , pp. 173-180
    • Shi, P.1    Hu, S.2    Zhu, Y.3
  • 55
    • 27744434850 scopus 로고    scopus 로고
    • Assessment of pulse rate variability by the method of pulse frequency demodulation
    • J. Hayano, A.K. Barros, A. Kamiya, N. Ohte, and F. Yasuma Assessment of pulse rate variability by the method of pulse frequency demodulation Biomed Eng Online 4 2005 62
    • (2005) Biomed Eng Online , vol.4 , pp. 62
    • Hayano, J.1    Barros, A.K.2    Kamiya, A.3    Ohte, N.4    Yasuma, F.5
  • 56
    • 78149330175 scopus 로고    scopus 로고
    • Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions
    • E. Gil Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions Physiol Meas 31 2010 1271
    • (2010) Physiol Meas , vol.31 , pp. 1271
    • Gil, E.1
  • 57
    • 39949085790 scopus 로고    scopus 로고
    • Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information?
    • S. Lu, H. Zhao, and K. Ju Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? J Clin Monit Comput 22 2008 23 29
    • (2008) J Clin Monit Comput , vol.22 , pp. 23-29
    • Lu, S.1    Zhao, H.2    Ju, K.3
  • 58
    • 70350439728 scopus 로고    scopus 로고
    • A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects
    • G. Lu, F. Yang, J.A. Taylor, and J.F. Stein A comparison of photoplethysmography and ECG recording to analyse heart rate variability in healthy subjects J Med Eng Technol 33 2009 634 641
    • (2009) J Med Eng Technol , vol.33 , pp. 634-641
    • Lu, G.1    Yang, F.2    Taylor, J.A.3    Stein, J.F.4
  • 59
    • 76249091685 scopus 로고    scopus 로고
    • Interchangeability between heart rate and photoplethysmography variabilities during sympathetic stimulations
    • K. Charlot Interchangeability between heart rate and photoplethysmography variabilities during sympathetic stimulations Physiol Meas 30 2009 1357
    • (2009) Physiol Meas , vol.30 , pp. 1357
    • Charlot, K.1
  • 60
    • 79951728836 scopus 로고    scopus 로고
    • Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea
    • A.H. Khandoker, C.K. Karmakar, and M. Palaniswami Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea Med Eng Phys 33 2011 204 209
    • (2011) Med Eng Phys , vol.33 , pp. 204-209
    • Khandoker, A.H.1    Karmakar, C.K.2    Palaniswami, M.3
  • 61
    • 0033613141 scopus 로고    scopus 로고
    • Screening of obstructive sleep apnea syndrome by heart rate variability analysis
    • F. Roche, J.-M. Gaspoz, and I. Court-Fortune Screening of obstructive sleep apnea syndrome by heart rate variability analysis Circulation 100 1999 1411 1415
    • (1999) Circulation , vol.100 , pp. 1411-1415
    • Roche, F.1    Gaspoz, J.-M.2    Court-Fortune, I.3
  • 62
    • 25144444183 scopus 로고    scopus 로고
    • Obstructive sleep apnea syndrome: Effect of respiratory events and arousal on pulse wave amplitude measured by photoplethysmography in NREM sleep
    • J. Haba-Rubio, G. Darbellay, and F.R. Herrmann Obstructive sleep apnea syndrome: effect of respiratory events and arousal on pulse wave amplitude measured by photoplethysmography in NREM sleep Sleep Breath 9 2005 73 81
    • (2005) Sleep Breath , vol.9 , pp. 73-81
    • Haba-Rubio, J.1    Darbellay, G.2    Herrmann, F.R.3
  • 64
    • 23844526783 scopus 로고    scopus 로고
    • Contactless multiple wavelength photoplethysmographic imaging: A first step toward "spO2 camera" technology
    • F. Wieringa, F. Mastik, and A. Steen Contactless multiple wavelength photoplethysmographic imaging: a first step toward "SpO2 camera" technology Ann Biomed Eng 33 2005 1034 1041
    • (2005) Ann Biomed Eng , vol.33 , pp. 1034-1041
    • Wieringa, F.1    Mastik, F.2    Steen, A.3
  • 65
    • 77954110075 scopus 로고    scopus 로고
    • Contactless and continuous monitoring of heart rate based on photoplethysmography on a mattress
    • M.Y.M. Wong Contactless and continuous monitoring of heart rate based on photoplethysmography on a mattress Physiol Meas 31 2010 1065
    • (2010) Physiol Meas , vol.31 , pp. 1065
    • Wong, M.Y.M.1
  • 67
    • 34548550924 scopus 로고    scopus 로고
    • Combined photoplethysmographic monitoring of respiration rate and pulse: A comparison between different measurement sites in spontaneously breathing subjects
    • L. Nilsson, T. Goscinski, S. Kalman, L.G. Lindberg, and A. Johansson Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjects Acta Anaesthesiol Scand 51 2007 1250 1257
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 1250-1257
    • Nilsson, L.1    Goscinski, T.2    Kalman, S.3    Lindberg, L.G.4    Johansson, A.5
  • 68
    • 7044223006 scopus 로고    scopus 로고
    • The effect of contacting force on photoplethysmographic signals
    • X.F. Teng, and Y.T. Zhang The effect of contacting force on photoplethysmographic signals Physiol Meas 25 2004 1323
    • (2004) Physiol Meas , vol.25 , pp. 1323
    • Teng, X.F.1    Zhang, Y.T.2
  • 69
    • 33745120147 scopus 로고    scopus 로고
    • The effect of applied sensor contact force on pulse transit time
    • X.F. Teng, and Y.T. Zhang The effect of applied sensor contact force on pulse transit time Physiol Meas 27 2006 675
    • (2006) Physiol Meas , vol.27 , pp. 675
    • Teng, X.F.1    Zhang, Y.T.2
  • 70
    • 0027670432 scopus 로고
    • The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph
    • K.H. Shelley, M. Dickstein, and S.M. Shulman The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph J Clin Monit 9 1993 283 287
    • (1993) J Clin Monit , vol.9 , pp. 283-287
    • Shelley, K.H.1    Dickstein, M.2    Shulman, S.M.3
  • 71
    • 14544301424 scopus 로고    scopus 로고
    • The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation
    • table of contents
    • K.H. Shelley, D. Tamai, D. Jablonka, M. Gesquiere, R.G. Stout, and D.G. Silverman The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation Anesth Analg 100 2005 743 747 table of contents
    • (2005) Anesth Analg , vol.100 , pp. 743-747
    • Shelley, K.H.1    Tamai, D.2    Jablonka, D.3    Gesquiere, M.4    Stout, R.G.5    Silverman, D.G.6
  • 73
    • 4143146627 scopus 로고    scopus 로고
    • An open-source algorithm to detect onset of arterial blood pressure pulses
    • W. Zong, T. Heldt, G. Moody, and R. Mark An open-source algorithm to detect onset of arterial blood pressure pulses Comput Cardiol 30 2003 259 262
    • (2003) Comput Cardiol , vol.30 , pp. 259-262
    • Zong, W.1    Heldt, T.2    Moody, G.3    Mark, R.4
  • 74
    • 77952961634 scopus 로고    scopus 로고
    • Stationarity of the heart rate variability by acceleration plethysmography: Short-term measurements of healthy young males in daily life
    • M. Takada, T. Ebara, Y. Sakai, and Y. Kuwano Stationarity of the heart rate variability by acceleration plethysmography: short-term measurements of healthy young males in daily life J Hum Ergol (Tokyo) 38 2009 41 50
    • (2009) J Hum Ergol (Tokyo) , vol.38 , pp. 41-50
    • Takada, M.1    Ebara, T.2    Sakai, Y.3    Kuwano, Y.4
  • 76
    • 60849106384 scopus 로고    scopus 로고
    • Heart rate extraction from photoplethysmogram waveform using wavelet multi-resolution analysis
    • T.-H. Fu, S.-H. Liu, and K.-T. Tang Heart rate extraction from photoplethysmogram waveform using wavelet multi-resolution analysis J Med Biol Eng 28 2008 229 232
    • (2008) J Med Biol Eng , vol.28 , pp. 229-232
    • Fu, T.-H.1    Liu, S.-H.2    Tang, K.-T.3
  • 77
    • 60749117508 scopus 로고    scopus 로고
    • Pulse onset detection using neighbor pulse-based signal enhancement
    • P. Xu, M. Bergsneider, and X. Hu Pulse onset detection using neighbor pulse-based signal enhancement Med Eng Phys 31 2009 337 345
    • (2009) Med Eng Phys , vol.31 , pp. 337-345
    • Xu, P.1    Bergsneider, M.2    Hu, X.3
  • 78
    • 0035073348 scopus 로고    scopus 로고
    • A new method for pulse oximetry possessing inherent insensitivity to artifact
    • M. Hayes, and P. Smith A new method for pulse oximetry possessing inherent insensitivity to artifact IEEE Trans Biomed Eng 48 2001 452 461
    • (2001) IEEE Trans Biomed Eng , vol.48 , pp. 452-461
    • Hayes, M.1    Smith, P.2
  • 79
    • 33344472354 scopus 로고    scopus 로고
    • Motion artifact reduction in photoplethysmography using independent component analysis
    • B. Kim, and S. Yoo Motion artifact reduction in photoplethysmography using independent component analysis IEEE Trans Biomed Eng 53 2006 566 568
    • (2006) IEEE Trans Biomed Eng , vol.53 , pp. 566-568
    • Kim, B.1    Yoo, S.2
  • 80
    • 33646529849 scopus 로고    scopus 로고
    • A method for automatic identification of reliable heart rates calculated from ECG and PPG waveforms
    • C. Yu, Z. Liu, T. McKenna, A.T. Reisner, and J. Reifman A method for automatic identification of reliable heart rates calculated from ECG and PPG waveforms J Am Med Inform Assoc 13 2006 309 320
    • (2006) J Am Med Inform Assoc , vol.13 , pp. 309-320
    • Yu, C.1    Liu, Z.2    McKenna, T.3    Reisner, A.T.4    Reifman, J.5
  • 83
    • 84928893608 scopus 로고    scopus 로고
    • Feasibility of photoplethymographic signal for assessment of autonomic response using heart rate variability analysis
    • F. Ibrahim, N.A.A. Osman, J. Usman, N.A. Kadri, Springer Berlin Heidelberg
    • N. Selvaraj, J. Santhosh, and S. Anand Feasibility of photoplethymographic signal for assessment of autonomic response using heart rate variability analysis F. Ibrahim, N.A.A. Osman, J. Usman, N.A. Kadri, 3rd Kuala Lumpur International Conference on Biomedical Engineering 2006 2007 Springer Berlin Heidelberg 391 395
    • (2007) 3rd Kuala Lumpur International Conference on Biomedical Engineering 2006 , pp. 391-395
    • Selvaraj, N.1    Santhosh, J.2    Anand, S.3
  • 84
    • 84928889729 scopus 로고    scopus 로고
    • Estimation of heart rate variability from peripheral pulse wave using PPG sensor
    • F. Ibrahim, N.A.A. Osman, J. Usman, N.A. Kadri, Springer Berlin Heidelberg
    • K. Srinivas, L.R.G. Reddy, and R. Srinivas Estimation of heart rate variability from peripheral pulse wave using PPG sensor F. Ibrahim, N.A.A. Osman, J. Usman, N.A. Kadri, 3rd Kuala Lumpur International Conference on Biomedical Engineering 2006 2007 Springer Berlin Heidelberg 325 328
    • (2007) 3rd Kuala Lumpur International Conference on Biomedical Engineering 2006 , pp. 325-328
    • Srinivas, K.1    Reddy, L.R.G.2    Srinivas, R.3
  • 85
    • 84945952672 scopus 로고    scopus 로고
    • Study on the peak interval variability of photoplethysmogtaphic signals
    • Biomedical Engineering
    • X.F. Teng, and Y.T. Zhang Study on the peak interval variability of photoplethysmogtaphic signals IEEE EMBS Asian-Pacific Conference on2003 Biomedical Engineering 2003 140 141
    • (2003) IEEE EMBS Asian-Pacific Conference on2003 , pp. 140-141
    • Teng, X.F.1    Zhang, Y.T.2
  • 86
    • 0029001432 scopus 로고
    • Spectral analysis of systolic blood pressure and heart rate oscillations related to respiration
    • D. Laude, F. Weise, A. Girard, and J. Elghozi Spectral analysis of systolic blood pressure and heart rate oscillations related to respiration Clin Exp Pharmacol Physiol 22 1995 352 357
    • (1995) Clin Exp Pharmacol Physiol , vol.22 , pp. 352-357
    • Laude, D.1    Weise, F.2    Girard, A.3    Elghozi, J.4
  • 87
    • 0036428523 scopus 로고    scopus 로고
    • Effects of olanzapine and clozapine upon pulse rate variability
    • M. Mueck-Weymann, T. Rechlin, and F. Ehrengut Effects of olanzapine and clozapine upon pulse rate variability Depress Anxiety 16 2002 93 99
    • (2002) Depress Anxiety , vol.16 , pp. 93-99
    • Mueck-Weymann, M.1    Rechlin, T.2    Ehrengut, F.3
  • 89
    • 33846929394 scopus 로고    scopus 로고
    • Poincaré Plot analysis for pulse interval extracted from non-contact photoplethysmography
    • IEEE-EMBS 2005 27th Annual International Conference of the2005
    • Q. Yihong, H. Sijung, and P.Y.S. Cheang Poincaré plot analysis for pulse interval extracted from non-contact photoplethysmography Engineering in Medicine and Biology Society IEEE-EMBS 2005 27th Annual International Conference of the2005 2005 1964 1967
    • (2005) Engineering in Medicine and Biology Society , pp. 1964-1967
    • Yihong, Q.1    Sijung, H.2    Cheang, P.Y.S.3
  • 90
    • 9244262208 scopus 로고
    • Methods in heart rate variability analysis: May the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm?
    • M. Janssen, C. Swenne, J. de Bie, H. ter Heide, J. van Bemmel, and O. Rompelman Methods in heart rate variability analysis: may the ventricular or the pulse rhythm be used as a substitute for the atrial rhythm? High Blood Pressure 3 1994 23 29
    • (1994) High Blood Pressure , vol.3 , pp. 23-29
    • Janssen, M.1    Swenne, C.2    De Bie, J.3    Ter Heide, H.4    Van Bemmel, J.5    Rompelman, O.6
  • 91
    • 34047151850 scopus 로고    scopus 로고
    • Spectral analysis of pulse transit time variability and its coherence with other cardiovascular variabilities
    • H. Ma, and Y. Zhang Spectral analysis of pulse transit time variability and its coherence with other cardiovascular variabilities Conf Proc IEEE Eng Med Biol Soc 2006 6442 6445
    • (2006) Conf Proc IEEE Eng Med Biol Soc , pp. 6442-6445
    • Ma, H.1    Zhang, Y.2
  • 92
    • 33646751684 scopus 로고    scopus 로고
    • Pulse transit time as an indirect marker for variations in cardiovascular related reactivity
    • J. Foo, and C. Lim Pulse transit time as an indirect marker for variations in cardiovascular related reactivity Technol Health Care 14 2006 97 108
    • (2006) Technol Health Care , vol.14 , pp. 97-108
    • Foo, J.1    Lim, C.2
  • 93
    • 0029874537 scopus 로고    scopus 로고
    • Autonomic control of skin microvessels: Assessment by power spectrum of photoplethysmographic waves
    • L. Bernardi, A. Radaelli, and P.L. Solda Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves Clin Sci 90 1996 345 355
    • (1996) Clin Sci , vol.90 , pp. 345-355
    • Bernardi, L.1    Radaelli, A.2    Solda, P.L.3
  • 94
    • 0030756718 scopus 로고    scopus 로고
    • Spectral analysis of AC and DC components of the pulse photoplethysmograph at rest and during induction of anaesthesia
    • P. Larsen, M. Harty, and M. Thiruchelvam Spectral analysis of AC and DC components of the pulse photoplethysmograph at rest and during induction of anaesthesia Int J Clin Monit Comput 14 1997 89 95
    • (1997) Int J Clin Monit Comput , vol.14 , pp. 89-95
    • Larsen, P.1    Harty, M.2    Thiruchelvam, M.3
  • 96
    • 0031710038 scopus 로고    scopus 로고
    • Stradling. Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome
    • D. Pitson Stradling. Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome Eur Respir J 12 1998 685 692
    • (1998) Eur Respir J , vol.12 , pp. 685-692
    • Pitson, D.1
  • 97
    • 0030691175 scopus 로고    scopus 로고
    • Synchronous and baroceptor-sensitive oscillations in skin microcirculation: Evidence for central autonomic control
    • L. Bernardi, D. Hayoz, and R. Wenzel Synchronous and baroceptor-sensitive oscillations in skin microcirculation: evidence for central autonomic control Am J Physiol Heart Circ Physiol 273 1997 H1867 H1878
    • (1997) Am J Physiol Heart Circ Physiol , vol.273
    • Bernardi, L.1    Hayoz, D.2    Wenzel, R.3
  • 99
    • 42449101828 scopus 로고    scopus 로고
    • Changes of central haemodynamic parameters during mental stress and acute bouts of static and dynamic exercise
    • C. Lydakis, A. Momen, and C. Blaha Changes of central haemodynamic parameters during mental stress and acute bouts of static and dynamic exercise J Hum Hypertens 22 2008 320 328
    • (2008) J Hum Hypertens , vol.22 , pp. 320-328
    • Lydakis, C.1    Momen, A.2    Blaha, C.3
  • 100
    • 27644553808 scopus 로고    scopus 로고
    • Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms
    • L. Xu, D. Zhang, and K. Wang Wavelet-based cascaded adaptive filter for removing baseline drift in pulse waveforms IEEE Trans Biomed Eng 52 2005 1973 1975
    • (2005) IEEE Trans Biomed Eng , vol.52 , pp. 1973-1975
    • Xu, L.1    Zhang, D.2    Wang, K.3
  • 101
    • 58149202537 scopus 로고    scopus 로고
    • Comparison of time-domain short-term heart interval variability analysis using a wrist-worn heart rate monitor and the conventional electrocardiogram
    • L.G.G. Porto, and L.F. Junqueira Jr. Comparison of time-domain short-term heart interval variability analysis using a wrist-worn heart rate monitor and the conventional electrocardiogram Pacing Clin Electrophysiol 32 2009 43 51
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 43-51
    • Porto, L.G.G.1    Junqueira, Jr.L.F.2
  • 103
    • 39149121476 scopus 로고    scopus 로고
    • Estimation of breathing rate from respiratory sinus arrhythmia: Comparison of various methods
    • A. Schäfer, and K. Kratky Estimation of breathing rate from respiratory sinus arrhythmia: comparison of various methods Ann Biomed Eng 36 2008 476 485
    • (2008) Ann Biomed Eng , vol.36 , pp. 476-485
    • Schäfer, A.1    Kratky, K.2
  • 104
    • 63149119225 scopus 로고    scopus 로고
    • Variations of HRV analysis in different approaches
    • F. Chang, C. Chang, C. Chiu, S. Hsu, and Y. Lin Variations of HRV analysis in different approaches Comput Cardiol 34 2007 17 20
    • (2007) Comput Cardiol , vol.34 , pp. 17-20
    • Chang, F.1    Chang, C.2    Chiu, C.3    Hsu, S.4    Lin, Y.5
  • 105
    • 79951728836 scopus 로고    scopus 로고
    • Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea
    • A.H. Khandoker, C.K. Karmakar, and M. Palaniswami Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea Med Eng Phys 33 2011 204 209
    • (2011) Med Eng Phys , vol.33 , pp. 204-209
    • Khandoker, A.H.1    Karmakar, C.K.2    Palaniswami, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.