Retinal status analysis method based on feature extraction and quantitative grading in OCT images

Author keywords

Feature quantification; Grade evaluation; Image processing; Morphological characterization; Retinal OCT images

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; COMPUTER AIDED ANALYSIS; DECISION MAKING; DIAGNOSIS; EXTRACTION; FEATURE EXTRACTION; GRADING; IMAGE ANALYSIS; IMAGE PROCESSING; OPHTHALMOLOGY; OPTICAL DATA PROCESSING; OPTICAL TOMOGRAPHY;

EID: 84979010836     PISSN: None     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/s12938-016-0206-x     Document Type: Article
Times cited : (27)

References (36)
  • 2
    • 79961012019 scopus 로고    scopus 로고
    • Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy
    • Virgili G, Menchini F, Murro V, Peluso E, Rosa F, Casazza G. Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy. Cochrane Database Syst Rev. 2011;7:CD008081.
    • (2011) Cochrane Database Syst Rev , vol.7
    • Virgili, G.1    Menchini, F.2    Murro, V.3    Peluso, E.4    Rosa, F.5    Casazza, G.6
  • 3
    • 84888003203 scopus 로고    scopus 로고
    • Optical coherence tomography-based observation of the natural history of drusenoid lesion in eyes with dry age-related macular degeneration
    • Ouyang Y, Heussen FM, Hariri A, Keane PA, Sadda SR. Optical coherence tomography-based observation of the natural history of drusenoid lesion in eyes with dry age-related macular degeneration. Ophthalmology. 2013;120(12):2656-65.
    • (2013) Ophthalmology , vol.120 , Issue.12 , pp. 2656-2665
    • Ouyang, Y.1    Heussen, F.M.2    Hariri, A.3    Keane, P.A.4    Sadda, S.R.5
  • 4
    • 84908363564 scopus 로고    scopus 로고
    • Optical coherence tomography retinal thickness and volume measurements in X-linked retinoschisis
    • Andreoli MT, Lim JI. Optical coherence tomography retinal thickness and volume measurements in X-linked retinoschisis. Am J Ophthalmol. 2014;158(3):567-73.
    • (2014) Am J Ophthalmol , vol.158 , Issue.3 , pp. 567-573
    • Andreoli, M.T.1    Lim, J.I.2
  • 5
    • 84896143213 scopus 로고    scopus 로고
    • Foveal thickness between stratus and spectralis optical coherence tomography in retinal diseases
    • Roh YR, Park KH, Woo SJ. Foveal thickness between stratus and spectralis optical coherence tomography in retinal diseases. Korean J Ophthalmol. 2013;27(4):268-75.
    • (2013) Korean J Ophthalmol , vol.27 , Issue.4 , pp. 268-275
    • Roh, Y.R.1    Park, K.H.2    Woo, S.J.3
  • 7
    • 77953142151 scopus 로고    scopus 로고
    • Three-dimensional analysis of retinal layer texture: identification of fluid-filled regions in SD-OCT of the macula
    • Quellec G, Lee K, Dolejsi M, Garvin MK, Abramoff MD, Sonka M. Three-dimensional analysis of retinal layer texture: identification of fluid-filled regions in SD-OCT of the macula. IEEE Trans Med Imaging. 2010;29(6):1321-30.
    • (2010) IEEE Trans Med Imaging , vol.29 , Issue.6 , pp. 1321-1330
    • Quellec, G.1    Lee, K.2    Dolejsi, M.3    Garvin, M.K.4    Abramoff, M.D.5    Sonka, M.6
  • 11
    • 80052138068 scopus 로고    scopus 로고
    • Automated macular pathology diagnosis in retinal OCT images using multi-scale spatial pyramid and local binary patterns in texture and shape encoding
    • Liu YY, Chen M, Ishikawa H, Wollstein G, Schuman JS, Rehg JM. Automated macular pathology diagnosis in retinal OCT images using multi-scale spatial pyramid and local binary patterns in texture and shape encoding. Med Image Anal. 2011;15(5):748-59.
    • (2011) Med Image Anal , vol.15 , Issue.5 , pp. 748-759
    • Liu, Y.Y.1    Chen, M.2    Ishikawa, H.3    Wollstein, G.4    Schuman, J.S.5    Rehg, J.M.6
  • 12
    • 84862833603 scopus 로고    scopus 로고
    • Computerized macular pathology diagnosis in spectral domain optical coherence tomography scans based on multiscale texture and shape features
    • Liu YY, Ishikawa H, Chen M, Wollstein G, Duker JS, Fujimoto JG, Schuman JS, Rehg JM. Computerized macular pathology diagnosis in spectral domain optical coherence tomography scans based on multiscale texture and shape features. Invest Ophthalmol Vis Sci. 2011;52(11):8316-22.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , Issue.11 , pp. 8316-8322
    • Liu, Y.Y.1    Ishikawa, H.2    Chen, M.3    Wollstein, G.4    Duker, J.S.5    Fujimoto, J.G.6    Schuman, J.S.7    Rehg, J.M.8
  • 13
    • 84888052810 scopus 로고    scopus 로고
    • Automatic analysis of selected choroidal diseases in OCT images of the eye fundus
    • Koprowski R, Teper S, Wrobel Z, Wylegala E. Automatic analysis of selected choroidal diseases in OCT images of the eye fundus. Biomed Eng Online. 2013;12:117.
    • (2013) Biomed Eng Online , vol.12 , pp. 117
    • Koprowski, R.1    Teper, S.2    Wrobel, Z.3    Wylegala, E.4
  • 14
    • 84894044914 scopus 로고    scopus 로고
    • Automatic method of analysis of OCT images in assessing the severity degree of glaucoma and the visual field loss
    • Koprowski R, Rzendkowski M, Wrobel Z. Automatic method of analysis of OCT images in assessing the severity degree of glaucoma and the visual field loss. BioMed Eng OnLine. 2014;13:16.
    • (2014) BioMed Eng OnLine , vol.13 , pp. 16
    • Koprowski, R.1    Rzendkowski, M.2    Wrobel, Z.3
  • 16
    • 75449091368 scopus 로고    scopus 로고
    • Speckle noise reduction in optical coherence tomography of paint layers
    • Hughes M, Spring M, Podoleanu A. Speckle noise reduction in optical coherence tomography of paint layers. Appl Opt. 2010;49(1):99-107.
    • (2010) Appl Opt , vol.49 , Issue.1 , pp. 99-107
    • Hughes, M.1    Spring, M.2    Podoleanu, A.3
  • 17
    • 35948991132 scopus 로고    scopus 로고
    • Enhancing the signal-to-noise ratio in ophthalmic optical coherence tomography by image registration-method and clinical examples
    • Jorgensen TM, Thomadsen J, Christensen U, Soliman W, Sander B. Enhancing the signal-to-noise ratio in ophthalmic optical coherence tomography by image registration-method and clinical examples. J Biomed Opt. 2007;12(4):041208-10.
    • (2007) J Biomed Opt , vol.12 , Issue.4 , pp. 041208-041210
    • Jorgensen, T.M.1    Thomadsen, J.2    Christensen, U.3    Soliman, W.4    Sander, B.5
  • 19
    • 33645653318 scopus 로고    scopus 로고
    • A review of image denoising algorithms, with a new one
    • Buades A, Coll B, Morel JM. A review of image denoising algorithms, with a new one. Siam J Multiscale Model Simul. 2005;4(2):490-530.
    • (2005) Siam J Multiscale Model Simul , vol.4 , Issue.2 , pp. 490-530
    • Buades, A.1    Coll, B.2    Morel, J.M.3
  • 21
    • 34547760736 scopus 로고    scopus 로고
    • Image denoising by sparse 3D transform-domain collaborative filtering
    • Dabov K, Foi A, Katkovnik V, Egiazarian K. Image denoising by sparse 3D transform-domain collaborative filtering. IEEE Trans Image Process. 2007;16(8):2080-95.
    • (2007) IEEE Trans Image Process , vol.16 , Issue.8 , pp. 2080-2095
    • Dabov, K.1    Foi, A.2    Katkovnik, V.3    Egiazarian, K.4
  • 22
    • 84946606472 scopus 로고    scopus 로고
    • Denoising optical coherence tomography using second order total generalized variation decomposition
    • Duan J, Lu W, Tench C, et al. Denoising optical coherence tomography using second order total generalized variation decomposition. Biomed Signal Process Control. 2016;24:120-7.
    • (2016) Biomed Signal Process Control , vol.24 , pp. 120-127
    • Duan, J.1    Lu, W.2    Tench, C.3
  • 23
    • 77950913679 scopus 로고    scopus 로고
    • General Bayesian estimation for speckle noise reduction in optical coherence tomography retinal imagery
    • Wong A, Mishra A, Bizheva K, Clausi DA. General Bayesian estimation for speckle noise reduction in optical coherence tomography retinal imagery. Opt Express. 2010;18(8):8338-52.
    • (2010) Opt Express , vol.18 , Issue.8 , pp. 8338-8352
    • Wong, A.1    Mishra, A.2    Bizheva, K.3    Clausi, D.A.4
  • 24
    • 84929458566 scopus 로고    scopus 로고
    • Three dimensional data-driven multi scale atomic representation of optical coherence tomography
    • Kafieh R, Rabbani H, Selesnick I. Three dimensional data-driven multi scale atomic representation of optical coherence tomography. IEEE Trans Med Imaging. 2015;34(5):1042-62.
    • (2015) IEEE Trans Med Imaging , vol.34 , Issue.5 , pp. 1042-1062
    • Kafieh, R.1    Rabbani, H.2    Selesnick, I.3
  • 26
    • 84876494218 scopus 로고    scopus 로고
    • Curvature correction of retinal OCTs using graph-based geometry detection
    • Kafieh R, Rabbani H, Abramoff MD, Sonka M. Curvature correction of retinal OCTs using graph-based geometry detection. Phys Med Biol. 2013;58(9):2925-38.
    • (2013) Phys Med Biol , vol.58 , Issue.9 , pp. 2925-2938
    • Kafieh, R.1    Rabbani, H.2    Abramoff, M.D.3    Sonka, M.4
  • 27
    • 65349170290 scopus 로고    scopus 로고
    • Multiresolution denoising for optical coherence tomography: a review and evaluation
    • Pizurica A, Jovanov L, Huysmans B, et al. Multiresolution denoising for optical coherence tomography: a review and evaluation. Curr Med Imaging Rev. 2008;4(4):270-84.
    • (2008) Curr Med Imaging Rev , vol.4 , Issue.4 , pp. 270-284
    • Pizurica, A.1    Jovanov, L.2    Huysmans, B.3
  • 28
    • 77956360101 scopus 로고    scopus 로고
    • Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation
    • Chiu SJ, Li XT, Nicholas P, Toth CA, Izatt JA, Farsiu S. Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation. Opt Express. 2010;18(18):19413-28.
    • (2010) Opt Express , vol.18 , Issue.18 , pp. 19413-19428
    • Chiu, S.J.1    Li, X.T.2    Nicholas, P.3    Toth, C.A.4    Izatt, J.A.5    Farsiu, S.6
  • 29
    • 84908432729 scopus 로고    scopus 로고
    • Automated retinal layers segmentation in SD-OCT images using dual-gradient and spatial correlation smoothness constraint
    • Niu S, Chen Q, de Sisternes L, Rubin DL, Zhang W, Liu Q. Automated retinal layers segmentation in SD-OCT images using dual-gradient and spatial correlation smoothness constraint. Comput Biol Med. 2014;54:116-28.
    • (2014) Comput Biol Med , vol.54 , pp. 116-128
    • Niu, S.1    Chen, Q.2    Sisternes, L.3    Rubin, D.L.4    Zhang, W.5    Liu, Q.6
  • 30
    • 79551600760 scopus 로고    scopus 로고
    • Segmentation of intra-retinal layers from optical coherence tomography images using an active contour approach
    • Yazdanpanah A, Hamarneh G, Smith BR, Sarunic MV. Segmentation of intra-retinal layers from optical coherence tomography images using an active contour approach. IEEE Trans Med Imaging. 2011;30(2):484-96.
    • (2011) IEEE Trans Med Imaging , vol.30 , Issue.2 , pp. 484-496
    • Yazdanpanah, A.1    Hamarneh, G.2    Smith, B.R.3    Sarunic, M.V.4
  • 32
    • 84887415523 scopus 로고    scopus 로고
    • High-accuracy retinal layer segmentation for optical coherence tomography using tracking kernels based on Gaussian mixture model
    • Han JH, Cha YM. High-accuracy retinal layer segmentation for optical coherence tomography using tracking kernels based on Gaussian mixture model. IEEE J Sel Topics Quantum Electron. 2013;20(2):1-10.
    • (2013) IEEE J Sel Topics Quantum Electron , vol.20 , Issue.2 , pp. 1-10
    • Han, J.H.1    Cha, Y.M.2
  • 35
    • 77955470855 scopus 로고    scopus 로고
    • Normal macular thickness measurements using optical coherence tomography in healthy eyes of adult Chinese persons: the Handan Eye Study
    • Duan XR, Liang YB, Friedman DS, Sun LP, Wong TY, Tao QS, Bao L, Wang NL, Wang JJ. Normal macular thickness measurements using optical coherence tomography in healthy eyes of adult Chinese persons: the Handan Eye Study. Ophthalmology. 2010;117(8):1585-94.
    • (2010) Ophthalmology , vol.117 , Issue.8 , pp. 1585-1594
    • Duan, X.R.1    Liang, Y.B.2    Friedman, D.S.3    Sun, L.P.4    Wong, T.Y.5    Tao, Q.S.6    Bao, L.7    Wang, N.L.8    Wang, J.J.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.