메뉴 건너뛰기




Volumn 62, Issue 5, 2017, Pages 706-711

Managing coexistent cataract and glaucoma with iStent

Author keywords

iStent; microinvasive glaucoma surgery; Schlemm canal; trabecular microbypass

Indexed keywords

ARTICLE; BLURRED VISION; CATARACT; DEVICE SAFETY; EYE IRRITATION; GLAUCOMA; HUMAN; IN-STENT RESTENOSIS; INTRAOCULAR HEMORRHAGE; INTRAOCULAR PRESSURE; INTRAOCULAR PRESSURE ABNORMALITY; IRITIS; OPHTHALMOLOGICAL IMPLANT; POSTOPERATIVE CARE; PRIORITY JOURNAL; PROSTHESIS DESIGN; RANDOMIZED CONTROLLED TRIAL (TOPIC); VISUAL DISORDER; CATARACT EXTRACTION; COMPLICATION; DEVICES; EQUIPMENT DESIGN; FILTERING OPERATION; GLAUCOMA DRAINAGE IMPLANT; PROCEDURES; STENT; VISUAL ACUITY;

EID: 84977672445     PISSN: 00396257     EISSN: 18793304     Source Type: Journal    
DOI: 10.1016/j.survophthal.2016.01.006     Document Type: Article
Times cited : (13)

References (27)
  • 1
    • 84905451886 scopus 로고    scopus 로고
    • Prospective evaluation of microinvasive glaucoma surgery with trabecular microbypass stents and prostaglandin in open-angle glaucoma
    • Ahmed, I.I.K., Katz, L.J., Chang, D.F., et al. Prospective evaluation of microinvasive glaucoma surgery with trabecular microbypass stents and prostaglandin in open-angle glaucoma. J Cataract Refract Surg 40 (2014), 1295–1300.
    • (2014) J Cataract Refract Surg , vol.40 , pp. 1295-1300
    • Ahmed, I.I.K.1    Katz, L.J.2    Chang, D.F.3
  • 3
    • 84884675029 scopus 로고    scopus 로고
    • Mid-term evaluation of the new Glaukos iStent with phacoemulsification in coexistent open-angle glaucoma or ocular hypertension and cataract
    • Arriola-Villalobos, P., Martinez-de-la-Casa, J.M., Diaz-Valle, D., et al. Mid-term evaluation of the new Glaukos iStent with phacoemulsification in coexistent open-angle glaucoma or ocular hypertension and cataract. Br J Ophthalmol 97:10 (2013), 1250–1255.
    • (2013) Br J Ophthalmol , vol.97 , Issue.10 , pp. 1250-1255
    • Arriola-Villalobos, P.1    Martinez-de-la-Casa, J.M.2    Diaz-Valle, D.3
  • 4
    • 84867413198 scopus 로고    scopus 로고
    • The effect of phacoemulsification and combined phaco/glaucoma procedures on the intraocular pressure in open-angle glaucoma. A review of the literature
    • Augustinus, C.J., Zeyen, T., The effect of phacoemulsification and combined phaco/glaucoma procedures on the intraocular pressure in open-angle glaucoma. A review of the literature. Bull Soc Belge Ophtalmol 320 (2012), 51–66.
    • (2012) Bull Soc Belge Ophtalmol , vol.320 , pp. 51-66
    • Augustinus, C.J.1    Zeyen, T.2
  • 5
    • 84861194914 scopus 로고    scopus 로고
    • Second-generation trabecular meshwork bypass stent (iStent inject) increases outflow facility in cultured human anterior segments
    • Bahler, C.K., Hann, C.R., Fjield, T., Haffner, D., Heitzmann, H., Fautsch, M.P., Second-generation trabecular meshwork bypass stent (iStent inject) increases outflow facility in cultured human anterior segments. Am J Ophthalmol 153 (2012), 1206–1213.
    • (2012) Am J Ophthalmol , vol.153 , pp. 1206-1213
    • Bahler, C.K.1    Hann, C.R.2    Fjield, T.3    Haffner, D.4    Heitzmann, H.5    Fautsch, M.P.6
  • 6
    • 11144301154 scopus 로고    scopus 로고
    • Trabecular bypass stents decrease intraocular pressure in cultured human anterior segments
    • Bahler, C.K., Smedley, G.T., Zhou, J., Johnson, D.H., Trabecular bypass stents decrease intraocular pressure in cultured human anterior segments. Am J Ophthalmol 138 (2004), 988–994.
    • (2004) Am J Ophthalmol , vol.138 , pp. 988-994
    • Bahler, C.K.1    Smedley, G.T.2    Zhou, J.3    Johnson, D.H.4
  • 7
    • 85027951920 scopus 로고    scopus 로고
    • Using multiple trabecular micro-bypass stents in cataract patients to treat open-angle glaucoma
    • Belovay, G.W., Naqi, A., Chan, B.J., Rateb, M., Ahmed, I.I., Using multiple trabecular micro-bypass stents in cataract patients to treat open-angle glaucoma. J Cataract Refract Surg 38 (2012), 1911–1917.
    • (2012) J Cataract Refract Surg , vol.38 , pp. 1911-1917
    • Belovay, G.W.1    Naqi, A.2    Chan, B.J.3    Rateb, M.4    Ahmed, I.I.5
  • 8
    • 79952831233 scopus 로고    scopus 로고
    • One-year analysis of the iStent trabecular microbypass in secondary glaucoma
    • Buchacra, O., Duch, S., Milla, E., Stirbu, O., One-year analysis of the iStent trabecular microbypass in secondary glaucoma. Clin Ophthalmol 5 (2011), 321–326.
    • (2011) Clin Ophthalmol , vol.5 , pp. 321-326
    • Buchacra, O.1    Duch, S.2    Milla, E.3    Stirbu, O.4
  • 9
    • 84864122246 scopus 로고    scopus 로고
    • Cataract surgery with trabecular micro-bypass stent implantation in patients with mild-to-moderate open-angle glaucoma and cataract: two-year follow-up
    • Craven, E.R., Katz, L.J., Wells, J.M., Giamporcaro, J.E., Cataract surgery with trabecular micro-bypass stent implantation in patients with mild-to-moderate open-angle glaucoma and cataract: two-year follow-up. J Cataract Refract Surg 38 (2012), 1339–1345.
    • (2012) J Cataract Refract Surg , vol.38 , pp. 1339-1345
    • Craven, E.R.1    Katz, L.J.2    Wells, J.M.3    Giamporcaro, J.E.4
  • 10
    • 77349119622 scopus 로고    scopus 로고
    • Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma: randomized double-masked clinical trial
    • Fea, A.M., Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma: randomized double-masked clinical trial. J Cataract Refract Surg 36:3 (2010), 407–412.
    • (2010) J Cataract Refract Surg , vol.36 , Issue.3 , pp. 407-412
    • Fea, A.M.1
  • 11
    • 84900411462 scopus 로고    scopus 로고
    • Prospective unmasked randomized evaluation of the iStent inject versus two ocular hypotensive agents in patients with primary open-angle glaucoma
    • Fea, A.M., Belda, J.I., Rekas, M., et al. Prospective unmasked randomized evaluation of the iStent inject versus two ocular hypotensive agents in patients with primary open-angle glaucoma. Clin Ophthalmol 8 (2014), 875–882.
    • (2014) Clin Ophthalmol , vol.8 , pp. 875-882
    • Fea, A.M.1    Belda, J.I.2    Rekas, M.3
  • 13
    • 79959952093 scopus 로고    scopus 로고
    • Novel glaucoma procedures: a report by the American academy of ophthalmology
    • Francis, B.A., Singh, K., Lin, S.C., et al. Novel glaucoma procedures: a report by the American academy of ophthalmology. Ophthalmology 118 (2011), 1466–1480.
    • (2011) Ophthalmology , vol.118 , pp. 1466-1480
    • Francis, B.A.1    Singh, K.2    Lin, S.C.3
  • 14
    • 85027480569 scopus 로고    scopus 로고
    • Glaucoma treatment paradigm driven by new interventions
    • EyeNet Magazine, American Academy of Ophthalmology San Francisco, CA
    • Karmel, M., Glaucoma treatment paradigm driven by new interventions. 2011, EyeNet Magazine, American Academy of Ophthalmology, San Francisco, CA, 41–45.
    • (2011) , pp. 41-45
    • Karmel, M.1
  • 15
    • 85027481209 scopus 로고    scopus 로고
    • Two approaches to MIGS: iStent and trabectome
    • EyeNet Magazine, American Academy of Ophthalmology San Francisco, CA
    • Karmel, M., Two approaches to MIGS: iStent and trabectome. 2014, EyeNet Magazine, American Academy of Ophthalmology, San Francisco, CA, 36–41.
    • (2014) , pp. 36-41
    • Karmel, M.1
  • 16
    • 84907709590 scopus 로고    scopus 로고
    • iStent trabecular micro-bypass stent for open-angle glaucoma
    • Le, K., Saheb, H., iStent trabecular micro-bypass stent for open-angle glaucoma. Clin Ophthalmol 8 (2014), 1937–1945.
    • (2014) Clin Ophthalmol , vol.8 , pp. 1937-1945
    • Le, K.1    Saheb, H.2
  • 17
    • 58849131406 scopus 로고    scopus 로고
    • Adherence with topical glaucoma medication monitored electronically the Travatan Dosing Aid study
    • Okeke, C.O., Quigley, H.A., Jampel, H.D., et al. Adherence with topical glaucoma medication monitored electronically the Travatan Dosing Aid study. Ophthalmology 116 (2009), 191–199.
    • (2009) Ophthalmology , vol.116 , pp. 191-199
    • Okeke, C.O.1    Quigley, H.A.2    Jampel, H.D.3
  • 18
    • 84884987161 scopus 로고    scopus 로고
    • Manchester iStent study: early results from a prospective UK case series
    • Patel, I., de Klerk, T.A., Au, L., Manchester iStent study: early results from a prospective UK case series. Clin Experiment Ophthalmol 41:7 (2013), 648–652.
    • (2013) Clin Experiment Ophthalmol , vol.41 , Issue.7 , pp. 648-652
    • Patel, I.1    de Klerk, T.A.2    Au, L.3
  • 19
    • 84905484545 scopus 로고    scopus 로고
    • Implantation of 2 trabecular microbypass stents in a patient with primary open-angle glaucoma refractory to previous glaucoma-filtering surgeries
    • Roelofs, K., Arora, S., Dorey, M.W., Implantation of 2 trabecular microbypass stents in a patient with primary open-angle glaucoma refractory to previous glaucoma-filtering surgeries. J Cataract Refract Surg 40 (2014), 1322–1324.
    • (2014) J Cataract Refract Surg , vol.40 , pp. 1322-1324
    • Roelofs, K.1    Arora, S.2    Dorey, M.W.3
  • 20
    • 0024952760 scopus 로고
    • Outflow resistance of enucleated human eyes at two different perfusion pressures and different extents of trabeculotomy
    • Rosenquist, R., Epstein, D., Melamed, S., Johnson, M., Grant, W.M., Outflow resistance of enucleated human eyes at two different perfusion pressures and different extents of trabeculotomy. Curr Eye Res 8:12 (1989), 1233–1240.
    • (1989) Curr Eye Res , vol.8 , Issue.12 , pp. 1233-1240
    • Rosenquist, R.1    Epstein, D.2    Melamed, S.3    Johnson, M.4    Grant, W.M.5
  • 21
    • 79952279829 scopus 로고    scopus 로고
    • Randomized evaluation of the trabecular micro-bypass stent with phacoemulsification in patients with glaucoma and cataract
    • Samuelson, T.W., Katz, L.J., Wells, J.M., Duh, Y., Giamporcaro, J.E., Randomized evaluation of the trabecular micro-bypass stent with phacoemulsification in patients with glaucoma and cataract. Ophthalmology 118 (2011), 459–467.
    • (2011) Ophthalmology , vol.118 , pp. 459-467
    • Samuelson, T.W.1    Katz, L.J.2    Wells, J.M.3    Duh, Y.4    Giamporcaro, J.E.5
  • 22
    • 34247895558 scopus 로고    scopus 로고
    • Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma
    • Spiegel, D., Wetzel, W., Haffner, D.S., Hill, R.A., Initial clinical experience with the trabecular micro-bypass stent in patients with glaucoma. Adv Ther 24:1 (2007), 161–170.
    • (2007) Adv Ther , vol.24 , Issue.1 , pp. 161-170
    • Spiegel, D.1    Wetzel, W.2    Haffner, D.S.3    Hill, R.A.4
  • 23
    • 66149147026 scopus 로고    scopus 로고
    • Coexistent primary open-angle glaucoma and cataract: interim analysis of a trabecular micro-bypass stent and concurrent cataract surgery
    • Spiegel, D., Wetzel, W., Neuhann, T., et al. Coexistent primary open-angle glaucoma and cataract: interim analysis of a trabecular micro-bypass stent and concurrent cataract surgery. Eur J Ophthalmol 19:3 (2009), 393–399.
    • (2009) Eur J Ophthalmol , vol.19 , Issue.3 , pp. 393-399
    • Spiegel, D.1    Wetzel, W.2    Neuhann, T.3
  • 24
    • 67651160811 scopus 로고    scopus 로고
    • The iStent trabecular micro-bypass stent: a case series
    • Vandewalle, E., Zeyen, T., Stalmans, I., The iStent trabecular micro-bypass stent: a case series. Bull Soc Belge Ophtalmol 1:311 (2009), 23–29.
    • (2009) Bull Soc Belge Ophtalmol , vol.1 , Issue.311 , pp. 23-29
    • Vandewalle, E.1    Zeyen, T.2    Stalmans, I.3
  • 25
    • 84899119165 scopus 로고    scopus 로고
    • Prospective, unmasked evaluation of the iStent inject system for open-angle glaucoma: synergy trial
    • Voskanyan, L., Garcia-Feijoo, J., Belda, J.I., Fea, A., Junemann, A., Baudouin, C., Synergy Study Group. Prospective, unmasked evaluation of the iStent inject system for open-angle glaucoma: synergy trial. Adv Ther 31:2 (2014), 189–201.
    • (2014) Adv Ther , vol.31 , Issue.2 , pp. 189-201
    • Voskanyan, L.1    Garcia-Feijoo, J.2    Belda, J.I.3    Fea, A.4    Junemann, A.5    Baudouin, C.6
  • 26
    • 84929580194 scopus 로고    scopus 로고
    • A review of the iStent trabecular micro-bypass stent: safety and efficacy
    • Wellik, S.R., Dale, E.A., A review of the iStent trabecular micro-bypass stent: safety and efficacy. Clin Ophthalmol 9 (2015), 677–684.
    • (2015) Clin Ophthalmol , vol.9 , pp. 677-684
    • Wellik, S.R.1    Dale, E.A.2
  • 27
    • 12844257372 scopus 로고    scopus 로고
    • A trabecular bypass flow hypothesis
    • Zhou, J., Smedley, G.T., A trabecular bypass flow hypothesis. J Glaucoma 14 (2005), 74–83.
    • (2005) J Glaucoma , vol.14 , pp. 74-83
    • Zhou, J.1    Smedley, G.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.