메뉴 건너뛰기




Volumn 26, Issue 4, 2016, Pages 245-249

Routine use of glidescope and macintosh laryngoscope by trainee anesthetists

Author keywords

Airway management; Endotracheal intubation; Glidescope; Glottic view; Laryngoscopy; Macintosh laryngoscope

Indexed keywords

ADULT; ANESTHESIST; ARTICLE; BODY HEIGHT; BODY MASS; BODY WEIGHT; CONTROLLED STUDY; ELECTIVE SURGERY; END TIDAL CARBON DIOXIDE TENSION; ENDOTRACHEAL INTUBATION; FEMALE; GENERAL ANESTHESIA; GLIDESCOPE VIDEOLARYNGOSCOPE; GLOTTIS; HUMAN; INTERMITTENT POSITIVE PRESSURE VENTILATION; MACINTOSH LARYNGOSCOPE; MALE; MEDICAL DEVICE COMPLICATION; OUTCOME ASSESSMENT; PREOPERATIVE EVALUATION; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; RESIDENCY EDUCATION; SAUDI ARABIA; UNIVERSITY HOSPITAL; VIDEOLARYNGOSCOPE; ANESTHESIOLOGY; CLINICAL COMPETENCE; COMPARATIVE STUDY; DEVICES; EDUCATION; LARYNGOSCOPE; LARYNGOSCOPY; MEDICAL EDUCATION; MIDDLE AGED; POSTOPERATIVE COMPLICATIONS; PROCEDURES; STANDARDS; STATISTICS AND NUMERICAL DATA; TREATMENT OUTCOME;

EID: 84977527690     PISSN: 1022386X     EISSN: 16817168     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (26)
  • 1
    • 54249167043 scopus 로고    scopus 로고
    • Comparison of Macintosh, Truview EVO2, Glidescope, and airwayscope laryngoscope use in patients with cervical spine immobilization
    • Malik MA, Maharaj CH, Harte BH, Laffey JG. Comparison of Macintosh, Truview EVO2, Glidescope, and airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 2008; 101:723-30.
    • (2008) Br J Anaesth , vol.101 , pp. 723-730
    • Malik, M.A.1    Maharaj, C.H.2    Harte, B.H.3    Laffey, J.G.4
  • 2
    • 73449125448 scopus 로고    scopus 로고
    • Is it time for a Glidescope letter?
    • Stanley GD. Is it time for a Glidescope letter? Anesthesiology 2009; 111:1391.
    • (2009) Anesthesiology , vol.111 , pp. 1391
    • Stanley, G.D.1
  • 3
    • 78650708929 scopus 로고    scopus 로고
    • Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2, 004 Glidescope intubations, complications, and failures from two institutions
    • Aziz MF, Healy D, Kheterpal S, Fu RF, Dillman D, Brambrink AM. Routine clinical practice effectiveness of the Glidescope in difficult airway management: an analysis of 2, 004 Glidescope intubations, complications, and failures from two institutions. Anesthesiology 2011; 114:34-41.
    • (2011) Anesthesiology , vol.114 , pp. 34-41
    • Aziz, M.F.1    Healy, D.2    Kheterpal, S.3    Fu, R.F.4    Dillman, D.5    Brambrink, A.M.6
  • 4
    • 77954156989 scopus 로고    scopus 로고
    • Is Glidescope the best way to intubate?
    • Sharma D. Is Glidescope the best way to intubate? Anesthesiology 2010; 113:258-9.
    • (2010) Anesthesiology , vol.113 , pp. 258-259
    • Sharma, D.1
  • 5
    • 79958697695 scopus 로고    scopus 로고
    • A comparative study on the usefulness of the Glidescope or Macintosh laryngoscope when intubating normal airways
    • Choi GS, Lee EH, Lim CS, Yoon SH. A comparative study on the usefulness of the Glidescope or Macintosh laryngoscope when intubating normal airways. Korean J Anesthesiol 2011; 60:339-43.
    • (2011) Korean J Anesthesiol , vol.60 , pp. 339-343
    • Choi, G.S.1    Lee, E.H.2    Lim, C.S.3    Yoon, S.H.4
  • 6
    • 84920818814 scopus 로고    scopus 로고
    • Glidescope Use improves intubation success rates: an observational study using propensity score matching
    • Ibinson JW, Ezaru CS, Cormican DS, Mangione MP. Glidescope Use improves intubation success rates: an observational study using propensity score matching. BMC Anesthesiol 2014; 14:101.
    • (2014) BMC Anesthesiol , vol.14 , pp. 101
    • Ibinson, J.W.1    Ezaru, C.S.2    Cormican, D.S.3    Mangione, M.P.4
  • 7
    • 58749099150 scopus 로고    scopus 로고
    • Laryngoscopy via Macintosh blade versus Glidescope: success rate and time for endotracheal intubation in untrained medical personnel
    • Nouruzi-Sedeh P, Schumann M, Groeben H. Laryngoscopy via Macintosh blade versus Glidescope: success rate and time for endotracheal intubation in untrained medical personnel. Anesthesiology 2009; 110:32-7.
    • (2009) Anesthesiology , vol.110 , pp. 32-37
    • Nouruzi-Sedeh, P.1    Schumann, M.2    Groeben, H.3
  • 8
    • 84896695631 scopus 로고    scopus 로고
    • Comparison of the Glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study
    • Langley A, Mar Fan G. Comparison of the Glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study. BMC Anesthesiol 2014; 14:10.
    • (2014) BMC Anesthesiol , vol.14 , pp. 10
    • Langley, A.1    Mar Fan, G.2
  • 9
    • 3242884152 scopus 로고    scopus 로고
    • Difficult Airway Society guidelines for management of the unanticipated difficult intubation
    • Henderson JJ, Popat MT, Latto IP, Pearce AC. Difficult Airway Society guidelines for management of the unanticipated difficult intubation. Anaesthesia 2004; 59:675-94.
    • (2004) Anaesthesia , vol.59 , pp. 675-694
    • Henderson, J.J.1    Popat, M.T.2    Latto, I.P.3    Pearce, A.C.4
  • 10
    • 84890570718 scopus 로고    scopus 로고
    • A comparison of the Glidescope with the Macintosh laryngoscope for nasotracheal intubation in patients with ankylosing spondylitis
    • Lili X, Zhiyong H, Jianjun S. A comparison of the Glidescope with the Macintosh laryngoscope for nasotracheal intubation in patients with ankylosing spondylitis. J Neurosurg Anesthesiol 2014; 26:27-31.
    • (2014) J Neurosurg Anesthesiol , vol.26 , pp. 27-31
    • Lili, X.1    Zhiyong, H.2    Jianjun, S.3
  • 11
    • 34250891900 scopus 로고    scopus 로고
    • Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes
    • Maharaj CH, Buckley E, Harte BH, Laffey JG. Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes. Anesthesiology 2007; 107:53-9.
    • (2007) Anesthesiology , vol.107 , pp. 53-59
    • Maharaj, C.H.1    Buckley, E.2    Harte, B.H.3    Laffey, J.G.4
  • 12
    • 84922593441 scopus 로고    scopus 로고
    • Defining and developing expertise in tracheal intubation using a Glidescope® for anaesthetists with expertise in Macintosh direct laryngoscopy: an in-vivo longitudinal study
    • Cortellazzi P, Caldiroli D, Byrne A, Sommariva A, Orena EF, Tramacere I. Defining and developing expertise in tracheal intubation using a Glidescope® for anaesthetists with expertise in Macintosh direct laryngoscopy: an in-vivo longitudinal study. Anaesthesia 2015; 70:290-5.
    • (2015) Anaesthesia , vol.70 , pp. 290-295
    • Cortellazzi, P.1    Caldiroli, D.2    Byrne, A.3    Sommariva, A.4    Orena, E.F.5    Tramacere, I.6
  • 14
    • 43149089854 scopus 로고    scopus 로고
    • Comparison of the Glidescope video laryngoscope and Macintosh laryngoscope in simulated tracheal intubation scenarios
    • Kim HJ, Chung SP, Park IC, Cho J, Lee HS, Park YS. Comparison of the Glidescope video laryngoscope and Macintosh laryngoscope in simulated tracheal intubation scenarios. Emerg Med J 2008; 25:279-82.
    • (2008) Emerg Med J , vol.25 , pp. 279-282
    • Kim, H.J.1    Chung, S.P.2    Park, I.C.3    Cho, J.4    Lee, H.S.5    Park, Y.S.6
  • 15
    • 26944432273 scopus 로고    scopus 로고
    • Does a new videolaryngoscope (Glidescope) provide better glottic exposure?
    • Hsiao WT, Lin YH, Wu HS, Chen CL. Does a new videolaryngoscope (Glidescope) provide better glottic exposure? Acta Anaesthesiol Taiwan 2005; 43:147-51.
    • (2005) Acta Anaesthesiol Taiwan , vol.43 , pp. 147-151
    • Hsiao, W.T.1    Lin, Y.H.2    Wu, H.S.3    Chen, C.L.4
  • 16
    • 35148891635 scopus 로고    scopus 로고
    • The clinical assessment of Glidescope in orotracheal intubation under general anesthesia
    • Xue FS, Zhang GH, Liu J, Li XY, Yang QY, Xu YC, et al. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia. Minerva Anestesiol 2007; 73:451-7.
    • (2007) Minerva Anestesiol , vol.73 , pp. 451-457
    • Xue, F.S.1    Zhang, G.H.2    Liu, J.3    Li, X.Y.4    Yang, Q.Y.5    Xu, Y.C.6
  • 17
    • 77449105751 scopus 로고    scopus 로고
    • Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the Glidescope
    • Serocki G, Bein B, Scholz J, Dörges V. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the Glidescope. Eur J Anaesthesiol 2010; 27:24-30.
    • (2010) Eur J Anaesthesiol , vol.27 , pp. 24-30
    • Serocki, G.1    Bein, B.2    Scholz, J.3    Dörges, V.4
  • 18
    • 84892716479 scopus 로고    scopus 로고
    • Tracheal intubation in patients with odentogenous abscesses and reduced mouth opening
    • Schumann M, Biesler, Börgers A, Pförtner R, Mohr C, Groeben H. Tracheal intubation in patients with odentogenous abscesses and reduced mouth opening. Br J Anaesth 2014; 112:348-54.
    • (2014) Br J Anaesth , vol.112 , pp. 348-354
    • Schumann, M.1    Biesler2    Börgers, A.3    Pförtner, R.4    Mohr, C.5    Groeben, H.6
  • 19
    • 80053208447 scopus 로고    scopus 로고
    • Glidescope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial
    • Andersen LH, Rovsing L, Olsen KS. Glidescope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial. Acta Anaesthesiol Scand 2011; 55:1090-7.
    • (2011) Acta Anaesthesiol Scand , vol.55 , pp. 1090-1097
    • Andersen, L.H.1    Rovsing, L.2    Olsen, K.S.3
  • 20
    • 84873656955 scopus 로고    scopus 로고
    • Comparison of 3 video laryngoscopes with the Macintosh in a manikin with easy and difficult simulated airways
    • Wang PK, Huang CC, Lee Y, Chen TY, Lai HY. Comparison of 3 video laryngoscopes with the Macintosh in a manikin with easy and difficult simulated airways. Am J Emerg Med 2013; 31:330-8.
    • (2013) Am J Emerg Med , vol.31 , pp. 330-338
    • Wang, P.K.1    Huang, C.C.2    Lee, Y.3    Chen, T.Y.4    Lai, H.Y.5
  • 22
    • 84904640687 scopus 로고    scopus 로고
    • A study of stress response to endotracheal intubation comparing Glidescope and flexible fiberoptic bronchoscope
    • Mansoor Aqil. A study of stress response to endotracheal intubation comparing Glidescope and flexible fiberoptic bronchoscope. Pak J Med Sci 2014; 30:1001-6.
    • (2014) Pak J Med Sci , vol.30 , pp. 1001-1006
    • Aqil, M.1
  • 24
    • 15944397631 scopus 로고    scopus 로고
    • The Glidescope video laryngoscope
    • Doyle DA. The Glidescope video laryngoscope. Anaesthesia 2005; 60:414-5.
    • (2005) Anaesthesia , vol.60 , pp. 414-415
    • Doyle, D.A.1
  • 25
    • 51849124729 scopus 로고    scopus 로고
    • Glidescope video laryngoscope: a randomized clinical trial in 203 paediatric patients
    • Kim JT, Na HS, Bae JY, Kim DW, Kim HS, Kim CS, et al. Glidescope video laryngoscope: a randomized clinical trial in 203 paediatric patients. Br J Anaesth 2008; 101:531-4.
    • (2008) Br J Anaesth , vol.101 , pp. 531-534
    • Kim, J.T.1    Na, H.S.2    Bae, J.Y.3    Kim, D.W.4    Kim, H.S.5    Kim, C.S.6
  • 26
    • 84880570193 scopus 로고    scopus 로고
    • A comparative trial of the Glidescope(R) video laryngoscope to direct laryngoscope in children with difficult direct laryngoscopy and an evaluation of the effect of blade size
    • Lee JH, Park YH, Byon HJ, Han WK, Kim HS, Kim CS, et al. A comparative trial of the Glidescope(R) video laryngoscope to direct laryngoscope in children with difficult direct laryngoscopy and an evaluation of the effect of blade size. Anesth Analg 2013; 117:176-81.
    • (2013) Anesth Analg , vol.117 , pp. 176-181
    • Lee, J.H.1    Park, Y.H.2    Byon, H.J.3    Han, W.K.4    Kim, H.S.5    Kim, C.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.