-
1
-
-
0042347783
-
Difficult tracheal intubation is more common in obese than in lean patients
-
Juvin P, Lavaut E, Dupont H, Lefevre P, Demetriou M, Dumoulin JL, Desmonts JM,. Difficult tracheal intubation is more common in obese than in lean patients. Anesth Analg 2003; 97: 595-600. (Pubitemid 36899772)
-
(2003)
Anesthesia and Analgesia
, vol.97
, Issue.2
, pp. 595-600
-
-
Juvin, P.1
Lavaut, E.2
Dupont, H.3
Lefevre, P.4
Demetriou, M.5
Dumoulin, J.-L.6
Desmonts, J.-M.7
-
2
-
-
41349096945
-
The importance of increased neck circumference to intubation difficulties in obese patients
-
DOI 10.1213/ane.0b013e3181679659, PII 0000053920080400000016
-
Gonzalez H, Minville V, Delanoue K, Mazerolles M, Concina D, Fourcade O,. The importance of increased neck circumference to intubation difficulties in obese patients. Anesth Analg 2008; 106: 1132-6. (Pubitemid 351450537)
-
(2008)
Anesthesia and Analgesia
, vol.106
, Issue.4
, pp. 1132-1136
-
-
Gonzalez, H.1
Minville, V.2
Delanoue, K.3
Mazerolles, M.4
Concina, D.5
Fourcade, O.6
-
3
-
-
61549133212
-
High body mass index is a weak predictor for difficult and failed tracheal intubation: A cohort study of 91,332 consecutive patients scheduled for direct laryngoscopy registered in the Danish Anesthesia Database
-
Lundstrøm LH, Møller AM, Rosenstock C, Astrup G, Wetterslev J,. High body mass index is a weak predictor for difficult and failed tracheal intubation: a cohort study of 91,332 consecutive patients scheduled for direct laryngoscopy registered in the Danish Anesthesia Database. Anesthesiology 2009; 110: 266-74.
-
(2009)
Anesthesiology
, vol.110
, pp. 266-274
-
-
Lundstrøm, L.H.1
Møller, A.M.2
Rosenstock, C.3
Astrup, G.4
Wetterslev, J.5
-
4
-
-
0028357626
-
The airway: Problems and predictions in 18,500 patients
-
Rose DK, Cohen MM,. The airway: problems and predictions in 18,500 patients. Can J Anaesth 1994; 41: 372-83. (Pubitemid 24164111)
-
(1994)
Canadian Journal of Anaesthesia
, vol.41
, Issue.5
, pp. 372-383
-
-
Rose, D.K.1
Cohen, M.M.2
-
5
-
-
0029977859
-
Preoperative airway assessment: Predictive value of a multivariate risk index
-
DOI 10.1097/00000539-199606000-00017
-
el-Ganzouri AR, McCarthy RJ, Tuman KJ, Tanck EN, Ivankovich AD,. Preoperative airway assessment: predictive value of a multivariate risk index. Anesth Analg 1996; 82: 1197-204. (Pubitemid 26158002)
-
(1996)
Anesthesia and Analgesia
, vol.82
, Issue.6
, pp. 1197-1204
-
-
El-Ganzouri, A.R.1
McCarthy, R.J.2
Tuman, K.J.3
Tanck, E.N.4
Ivankovich, A.D.5
-
6
-
-
33750459383
-
Incidence and predictors of difficult and impossible mask ventilation
-
DOI 10.1097/00000542-200611000-00007, PII 0000054220061100000007
-
Kheterpal S, Han R, Tremper KK, Shanks A, Tait AR, O'Reilly M, Ludwig TA,. Incidence and predictors of difficult and impossible mask ventilation. Anesthesiology 2006; 105: 885-91. (Pubitemid 44655497)
-
(2006)
Anesthesiology
, vol.105
, Issue.5
, pp. 885-891
-
-
Kheterpal, S.1
Han, R.2
Tremper, K.K.3
Shanks, A.4
Tait, A.R.5
O'Reilly, M.6
Ludwig, T.A.7
-
7
-
-
0025730155
-
Effect of obesity on safe duration of apnea in anesthetized humans
-
Jense HG, Dubin SA, Silverstein PI, O'Leary-Escolas U,. Effect of obesity on safe duration of apnea in anesthetized humans. Anesth Analg 1991; 72: 89-93.
-
(1991)
Anesth Analg
, vol.72
, pp. 89-93
-
-
Jense, H.G.1
Dubin, S.A.2
Silverstein, P.I.3
O'Leary-Escolas, U.4
-
9
-
-
0030886969
-
Prevalence of obesity in surgical patients: A comparative survey in the United States and Australia
-
Riley RH, Burke V,. Prevalence of obesity in surgical patients: a comparative survey in the United States and Australia. J Qual Clin Pract 1997; 17: 147-54. (Pubitemid 27407991)
-
(1997)
Journal of Quality in Clinical Practice
, vol.17
, Issue.3
, pp. 147-154
-
-
Riley, R.H.1
Burke, V.2
-
10
-
-
16344374081
-
Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients
-
Cooper RM, Pacey JA, Bishop MJ, McCluskey SA,. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anaesth 2005; 52: 191-8. (Pubitemid 40467979)
-
(2005)
Canadian Journal of Anesthesia
, vol.52
, Issue.2
, pp. 191-198
-
-
Cooper, R.M.1
Pacey, J.A.2
Bishop, M.J.3
McCluskey, S.A.4
-
11
-
-
14844339902
-
The GlideScope Video Laryngoscope: Randomized clinical trial in 200 patients
-
DOI 10.1093/bja/aei041
-
Sun DA, Warriner CB, Parsons DG, Klein R, Umedaly HS, Moult M,. The GlideScope video laryngoscope: randomized clinical trial in 200 patients. Br J Anaesth 2005; 94: 381-4. (Pubitemid 40352862)
-
(2005)
British Journal of Anaesthesia
, vol.94
, Issue.3
, pp. 381-384
-
-
Sun, D.A.1
Warriner, C.B.2
Parsons, D.G.3
Klein, R.4
Umedaly, H.S.5
Moult, M.6
-
12
-
-
78049491780
-
Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC, Glidescope vs. The Macintosh laryngoscope for tracheal intubation
-
Teoh WH, Saxena S, Shah MK, Sia AT,. Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC, Glidescope vs. the Macintosh laryngoscope for tracheal intubation. Anaesthesia 2010; 65: 1126-32.
-
(2010)
Anaesthesia
, vol.65
, pp. 1126-1132
-
-
Teoh, W.H.1
Saxena, S.2
Shah, M.K.3
Sia, A.T.4
-
13
-
-
54249167043
-
Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization
-
Malik MA, Maharaj CH, Harte BH, Laffey JG,. Comparison of Macintosh, Truview EVO2, Glidescope, and Airwayscope laryngoscope use in patients with cervical spine immobilization. Br J Anaesth 2008; 101: 723-30.
-
(2008)
Br J Anaesth
, vol.101
, pp. 723-730
-
-
Malik, M.A.1
Maharaj, C.H.2
Harte, B.H.3
Laffey, J.G.4
-
14
-
-
74949099834
-
Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation
-
Malik MA, Subramaniam R, Maharaj CH, Harte BH, Laffey JG,. Randomized controlled trial of the Pentax AWS, Glidescope, and Macintosh laryngoscopes in predicted difficult intubation. Br J Anaesth 2009; 103: 761-8.
-
(2009)
Br J Anaesth
, vol.103
, pp. 761-768
-
-
Malik, M.A.1
Subramaniam, R.2
Maharaj, C.H.3
Harte, B.H.4
Laffey, J.G.5
-
15
-
-
77449105751
-
Management of the predicted difficult airway: A comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope
-
Serocki G, Bein B, Scholz J, Dörges V,. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. Eur J Anaesthesiol 2010; 27: 24-30.
-
(2010)
Eur J Anaesthesiol
, vol.27
, pp. 24-30
-
-
Serocki, G.1
Bein, B.2
Scholz, J.3
Dörges, V.4
-
16
-
-
70350702956
-
A comparison of three videolaryngoscopes: The Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients
-
Maassen R, Lee R, Hermans B, Marcus M, van, Zundert A,. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients. Anesth Analg 2009; 109: 1560-5.
-
(2009)
Anesth Analg
, vol.109
, pp. 1560-1565
-
-
Maassen, R.1
Lee, R.2
Hermans, B.3
Van, M.M.4
Zundert, A.5
-
17
-
-
35948977295
-
Videolaryngoscopy improves intubation condition in morbidly obese patients
-
DOI 10.1017/S0265021507000889, PII S0265021507000889
-
Marrel J, Blanc C, Frascarolo P, Magnusson L,. Videolaryngoscopy improves intubation condition in morbidly obese patients. Eur J Anaesthesiol 2007; 24: 1045-9. (Pubitemid 350073497)
-
(2007)
European Journal of Anaesthesiology
, vol.24
, Issue.12
, pp. 1045-1049
-
-
Marrel, J.1
Blanc, C.2
Frascarolo, P.3
Magnusson, L.4
-
18
-
-
67650941346
-
Video-assisted versus conventional tracheal intubation in morbidly obese patients
-
Dhonneur G, Abdi W, Ndoko SK, Amathieu R, Risk N, El Housseini L, Polliand C, Champault G, Combes X, Tual L,. Video-assisted versus conventional tracheal intubation in morbidly obese patients. Obes Surg 2009; 19: 1096-101.
-
(2009)
Obes Surg
, vol.19
, pp. 1096-1101
-
-
Dhonneur, G.1
Abdi, W.2
Ndoko, S.K.3
Amathieu, R.4
Risk, N.5
El Housseini, L.6
Polliand, C.7
Champault, G.8
Combes, X.9
Tual, L.10
-
19
-
-
38949159274
-
Tracheal intubation of morbidly obese patients: A randomized trial comparing performance of Macintosh and Airtraq laryngoscopes
-
DOI 10.1093/bja/aem346
-
Ndoko SK, Amathieu R, Tual L, Polliand C, Kamoun W, El Housseini L, Champault G, Dhonneur G,. Tracheal intubation of morbidly obese patients: a randomized trial comparing performance of Macintosh and Airtraq laryngoscopes. Br J Anaesth 2008; 100: 263-8. (Pubitemid 351773670)
-
(2008)
British Journal of Anaesthesia
, vol.100
, Issue.2
, pp. 263-268
-
-
Ndoko, S.K.1
Amathieu, R.2
Tual, L.3
Polliand, C.4
Kamoun, W.5
El Housseini, L.6
Champault, G.7
Dhonneur, G.8
-
20
-
-
0031469105
-
The intubation difficulty scale (IDS): Proposal and evaluation of a new score characterizing the complexity of endotracheal intubation
-
DOI 10.1097/00000542-199712000-00005
-
Adnet F, Borron SW, Racine SX, Clemessy JL, Fournier JL, Plaisance P, Lapandry C,. The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology 1997; 87: 1290-7. (Pubitemid 28007322)
-
(1997)
Anesthesiology
, vol.87
, Issue.6
, pp. 1290-1297
-
-
Adnet, F.1
Borron, S.W.2
Racine, S.X.3
Clemessy, J.-L.4
Fournier, J.-L.5
Plaisance, P.6
Lapandry, C.7
-
21
-
-
0023238545
-
Difficult tracheal intubation: A retrospective study
-
DOI 10.1111/j.1365-2044.1987.tb04039.x
-
Samsoon GL, Young JR,. Difficult tracheal intubation: a retrospective study. Anaesthesia 1987; 42: 487-90. (Pubitemid 17074035)
-
(1987)
Anaesthesia
, vol.42
, Issue.5
, pp. 487-490
-
-
Samsoon, G.L.T.1
Young, J.R.B.2
-
22
-
-
7644233191
-
Laryngoscopy and morbid obesity: A comparison of the "sniff" and "ramped" positions
-
DOI 10.1381/0960892042386869
-
Collins JS, Lemmens HJ, Brodsky JB, Brock-Utne JG, Levitan RM,. Laryngoscopy and morbid obesity: a comparison of the 'sniff' and 'ramped' positions. Obes Surg 2004; 14: 1171-5. (Pubitemid 39458589)
-
(2004)
Obesity Surgery
, vol.14
, Issue.9
, pp. 1171-1175
-
-
Collins, J.S.1
Lemmens, H.J.M.2
Brodsky, J.B.3
Brock-Utne, J.G.4
Levitan, R.M.5
-
23
-
-
31444432286
-
The dose of succinylcholine in morbid obesity
-
DOI 10.1213/01.ane.0000194876.00551.0e
-
Lemmens HJM, Brodsky JB,. The dose of succinylcholine in morbid obesity. Anesth Analg 2006; 102: 438-42. (Pubitemid 43152592)
-
(2006)
Anesthesia and Analgesia
, vol.102
, Issue.2
, pp. 438-442
-
-
Lemmens, H.J.M.1
Brodsky, J.B.2
-
24
-
-
33846644972
-
Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope
-
Jones PM, Turkstra TP, Armstrong KP, Armstrong PM, Cherry RA, Hoogstra J, Harle CC,. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope. Can J Anaesth 2007; 54: 21-7. (Pubitemid 46178782)
-
(2007)
Canadian Journal of Anesthesia
, vol.54
, Issue.1
, pp. 21-27
-
-
Jones, P.M.1
Turkstra, T.P.2
Armstrong, K.P.3
Armstrong, P.M.4
Cherry, R.A.5
Hoogstra, J.6
Harle, C.C.7
-
25
-
-
77956391576
-
Clinical comparison of two styletangles for orotracheal intubation with the GlideScope video laryngoscope
-
Dupanović M, Isaacson SA, Borovcanin Z, Jain S, Korten S, Karan S, Messing SP,. Clinical comparison of two styletangles for orotracheal intubation with the GlideScope video laryngoscope. J Clin Anesth 2010; 22: 352-9.
-
(2010)
J Clin Anesth
, vol.22
, pp. 352-359
-
-
Dupanović, M.1
Isaacson, S.A.2
Borovcanin, Z.3
Jain, S.4
Korten, S.5
Karan, S.6
Messing, S.P.7
-
26
-
-
0021701206
-
Difficult tracheal intubation in obstetrics
-
DOI 10.1111/j.1365-2044.1983.tb08932.x
-
Cormack RS, Lehane J,. Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 1105-11. (Pubitemid 15103964)
-
(1984)
Anaesthesia
, vol.39
, Issue.11
, pp. 1105-1111
-
-
Cormack, R.S.1
Lehane, J.2
-
27
-
-
75749110160
-
Patient- and operator-related factors associated with successful Glidescope intubations: A prospective observational study in 742 patients
-
Siu LW, Mathieson E, Naik VN, Chandra D, Joo HS,. Patient- and operator-related factors associated with successful Glidescope intubations: a prospective observational study in 742 patients. Anaesth Intensive Care 2010; 38: 70-5.
-
(2010)
Anaesth Intensive Care
, vol.38
, pp. 70-75
-
-
Siu, L.W.1
Mathieson, E.2
Naik, V.N.3
Chandra, D.4
Joo, H.S.5
-
28
-
-
11444255353
-
The Glidescope system: A clinical assessment of performance
-
DOI 10.1111/j.1365-2044.2004.04013.x
-
Rai MR, Dering A, Verghese C,. The Glidescope system: a clinical assessment of performance. Anaesthesia 2005; 60: 60-4. (Pubitemid 40081241)
-
(2005)
Anaesthesia
, vol.60
, Issue.1
, pp. 60-64
-
-
Rai, M.R.1
Dering, A.2
Verghese, C.3
-
29
-
-
44949109993
-
A quantitative review and meta-analysis of performance of non-standard laryngoscopes and rigid fibreoptic intubation aids
-
DOI 10.1111/j.1365-2044.2008.05489.x
-
Mihai R, Blair E, Kay H, Cook TM,. A quantitative review and meta-analysis of performance of non-standard laryngoscopes and rigid fibreoptic intubation aids. Anaesthesia 2008; 63: 745-60. (Pubitemid 351814237)
-
(2008)
Anaesthesia
, vol.63
, Issue.7
, pp. 745-760
-
-
Mihai, R.1
Blair, E.2
Kay, H.3
Cook, T.M.4
-
30
-
-
34250202186
-
Comparison of hemodynamic responses to orotracheal intubation with the GlideScope videolaryngoscope and the Macintosh direct laryngoscope
-
DOI 10.1016/j.jclinane.2006.11.004, PII S0952818007000803
-
Xue FS, Zhang GH, Li XY, Sun HT, Li P, Li CW, Liu KP,. Comparison of hemodynamic responses to orotracheal intubation with the GlideScope videolaryngoscope and the Macintosh direct laryngoscope. J Clin Anesth 2007; 19: 245-50. (Pubitemid 46899486)
-
(2007)
Journal of Clinical Anesthesia
, vol.19
, Issue.4
, pp. 245-250
-
-
Xue, F.S.1
Zhang, G.H.2
Li, X.Y.3
Sun, H.T.4
Li, P.5
Li, C.W.6
Liu, K.P.7
-
31
-
-
17144365474
-
A comparison of the GlideScope with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway
-
Lim Y, Yeo SW,. A comparison of the GlideScope with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway. Anaesth Intensive Care 2005; 33: 243-7. (Pubitemid 40521027)
-
(2005)
Anaesthesia and Intensive Care
, vol.33
, Issue.2
, pp. 243-247
-
-
Lim, Y.1
Yeo, S.W.2
-
32
-
-
0031867393
-
Value of oropharyngeal Mallampati classification in predicting difficult laryngoscopy among obese patients
-
Voyagis GS, Kyriakis KP, Dimitriou V, Vrettou I,. Value of oropharyngeal Mallampati classification in predicting difficult laryngoscopy among obese patients. Eur J Anaesthesiol 1998; 15: 330-4. (Pubitemid 28389009)
-
(1998)
European Journal of Anaesthesiology
, vol.15
, Issue.3
, pp. 330-334
-
-
Voyagis, G.S.1
Kyriakis, K.P.2
Dimitriou, V.3
Vrettou, I.4
-
33
-
-
33847397053
-
Ultrasound quantification of anterior soft tissue thickness fails to predict difficult laryngoscopy in obese patients
-
Komatsu R, Sengupta P, Wadhwa A, Akça O, Sessler DI, Ezri T, Lenhardt R,. Ultrasound quantification of anterior soft tissue thickness fails to predict difficult laryngoscopy in obese patients. Anaesth Intensive Care 2007; 35: 32-7. (Pubitemid 46344282)
-
(2007)
Anaesthesia and Intensive Care
, vol.35
, Issue.1
, pp. 32-37
-
-
Komatsu, R.1
Sengupta, P.2
Wadhwa, A.3
Akca, O.4
Sessler, D.I.5
Ezri, T.6
Lenhardt, R.7
-
34
-
-
67349149661
-
Predicting difficult airways using the intubation difficulty scale: A study comparing obese and non-obese patients
-
Lavi R, Segal D, Ziser A,. Predicting difficult airways using the intubation difficulty scale: a study comparing obese and non-obese patients. J Clin Anesth 2009; 21: 264-7.
-
(2009)
J Clin Anesth
, vol.21
, pp. 264-267
-
-
Lavi, R.1
Segal, D.2
Ziser, A.3
-
35
-
-
76749170225
-
Difficult tracheal intubation [letter]
-
Combes X, Dhonneur G,. Difficult tracheal intubation [letter]. Br J Anaesth 2010; 104: 260-1.
-
(2010)
Br J Anaesth
, vol.104
, pp. 260-261
-
-
Combes, X.1
Dhonneur, G.2
-
36
-
-
29644439239
-
Evaluation of the airway and preparation for difficulty
-
DOI 10.1016/j.bpa.2005.07.004, PII S1521689605000479, Difficult Airway Management
-
Pearce A,. Evaluation of the airway and preparation for difficulty. Best Pract Res Clin Anaesthesiol 2005; 19: 559-79. (Pubitemid 43019583)
-
(2005)
Best Practice and Research: Clinical Anaesthesiology
, vol.19
, Issue.4
, pp. 559-579
-
-
Pearce, A.1
|