메뉴 건너뛰기




Volumn 8, Issue , 2014, Pages

Inter- and intra-observer reliability of measurement of pedicle screw breach assessed by postoperative CT scans

Author keywords

CT imaging; Inter intra observer reliability; Pedicle screw breach

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 84974698848     PISSN: None     EISSN: 22114599     Source Type: Journal    
DOI: 10.14444/1011     Document Type: Article
Times cited : (9)

References (27)
  • 1
    • 13444291573 scopus 로고    scopus 로고
    • Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis
    • Kim YJ, Lenke LG, Cho SK, et al. Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis. Spine 2004;29:2040-2048.
    • (2004) Spine , vol.29 , pp. 2040-2048
    • Kim, Y.J.1    Lenke, L.G.2    Cho, S.K.3
  • 2
    • 0742269913 scopus 로고    scopus 로고
    • Direct vertebral rotation: a new technique of three dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis
    • Lee SM, Suk SI, Chung ER. Direct vertebral rotation: a new technique of three dimensional deformity correction with segmental pedicle screw fixation in adolescent idiopathic scoliosis. Spine 2004;29:343-349.
    • (2004) Spine , vol.29 , pp. 343-349
    • Lee, S.M.1    Suk, S.I.2    Chung, E.R.3
  • 3
    • 25444504048 scopus 로고    scopus 로고
    • Thoracic adolescent idiopathic scoliosis curves between 70 degrees and 100 degrees: Is anterior release necessary?
    • Luhmann SJ, Lenke LG, Kim YJ, et al. Thoracic adolescent idiopathic scoliosis curves between 70 degrees and 100 degrees: Is anterior release necessary? Spine 2005;30:2061-2067.
    • (2005) Spine , vol.30 , pp. 2061-2067
    • Luhmann, S.J.1    Lenke, L.G.2    Kim, Y.J.3
  • 4
    • 22544469440 scopus 로고    scopus 로고
    • Selective thoracic fusion with segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis: more than 5-year follow-up
    • Suk SI, Lee SM, Chung ER, et al. Selective thoracic fusion with segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis: more than 5-year follow-up. Spine 2005;30:1602-1609.
    • (2005) Spine , vol.30 , pp. 1602-1609
    • Suk, S.I.1    Lee, S.M.2    Chung, E.R.3
  • 5
    • 42749084832 scopus 로고    scopus 로고
    • Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature
    • Kakkos SK, Shepard AD. Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg 2008;47:1074-1082.
    • (2008) J Vasc Surg , vol.47 , pp. 1074-1082
    • Kakkos, S.K.1    Shepard, A.D.2
  • 6
    • 25444518981 scopus 로고    scopus 로고
    • Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography
    • Kim YJ, Lenke LG, Cheh G, et al. Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography. Spine 2005;30:2084-2088.
    • (2005) Spine , vol.30 , pp. 2084-2088
    • Kim, Y.J.1    Lenke, L.G.2    Cheh, G.3
  • 7
    • 0029893644 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in lumbar vertebrae
    • Castro WH, Halm H, Jerosch J, et al. Accuracy of pedicle screw placement in lumbar vertebrae. Spine 1996;21:1320-1324.
    • (1996) Spine , vol.21 , pp. 1320-1324
    • Castro, W.H.1    Halm, H.2    Jerosch, J.3
  • 8
    • 34547113301 scopus 로고    scopus 로고
    • Observer reliability in evaluating pedicle screw placement using computed tomography
    • Kosmopoulos V, Theumann N, Binaghi S, et al. Observer reliability in evaluating pedicle screw placement using computed tomography. Internat Orthop 2007;31:531-536.
    • (2007) Internat Orthop , vol.31 , pp. 531-536
    • Kosmopoulos, V.1    Theumann, N.2    Binaghi, S.3
  • 9
    • 1842564006 scopus 로고    scopus 로고
    • Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation
    • Learch TJ, Massie JB, Pathria MN, et al. Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine 2004;29:767-773.
    • (2004) Spine , vol.29 , pp. 767-773
    • Learch, T.J.1    Massie, J.B.2    Pathria, M.N.3
  • 10
    • 34248512369 scopus 로고    scopus 로고
    • Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe?
    • Schizas C, Theumann N, Kosmopoulos V. Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe? Eur Spine J 2007;16:625-629.
    • (2007) Eur Spine J , vol.16 , pp. 625-629
    • Schizas, C.1    Theumann, N.2    Kosmopoulos, V.3
  • 11
    • 0031431918 scopus 로고    scopus 로고
    • Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine
    • Yoo JU, Ghanayem AJ, Petersilge C, et al. Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine. Spine 1997;22:2668-2671.
    • (1997) Spine , vol.22 , pp. 2668-2671
    • Yoo, J.U.1    Ghanayem, A.J.2    Petersilge, C.3
  • 12
    • 33845487571 scopus 로고    scopus 로고
    • Stepwise methodology for plain radiographic assessment of pedicle screw placement: a comparison with computed tomography
    • Choma TJ, Denis F, Lonstein JE, et al. Stepwise methodology for plain radiographic assessment of pedicle screw placement: a comparison with computed tomography. J Spinal Disord Tech 2006;19:547-553.
    • (2006) J Spinal Disord Tech , vol.19 , pp. 547-553
    • Choma, T.J.1    Denis, F.2    Lonstein, J.E.3
  • 13
    • 33644877691 scopus 로고    scopus 로고
    • Clinical accuracy of fluoroscopic computer assisted pedicle screw fixation: a CT analysis
    • Rampersaud YR, Pik JH, Salonen D, et al. Clinical accuracy of fluoroscopic computer assisted pedicle screw fixation: a CT analysis. Spine 2005;30:E183-E190.
    • (2005) Spine , vol.30 , pp. E183-E190
    • Rampersaud, Y.R.1    Pik, J.H.2    Salonen, D.3
  • 14
    • 0035500223 scopus 로고    scopus 로고
    • In vivo accuracy of thoracic pedicle screws
    • Nov 1
    • Belmont PK Jr, Klemme WR, Dhawan A, et al. In vivo accuracy of thoracic pedicle screws. Spine 2001 Nov 1; 26(21):2340-2346.
    • (2001) Spine , vol.26 , Issue.21 , pp. 2340-2346
    • Belmont, P.K.1    Klemme, W.R.2    Dhawan, A.3
  • 15
    • 0022340141 scopus 로고
    • Quantitative anatomy of the thoracolumbarepidural space
    • Dec
    • Reynolds AF, Roberts A, Pollay M, et al. Quantitative anatomy of the thoracolumbarepidural space. Neurosurgery 1985 Dec;17 (6):905-7.
    • (1985) Neurosurgery , vol.17 , Issue.6 , pp. 905-907
    • Reynolds, A.F.1    Roberts, A.2    Pollay, M.3
  • 16
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Jan
    • Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine 1990 Jan;15 (1):11-4.
    • (1990) Spine , vol.15 , Issue.1 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 17
    • 84944661914 scopus 로고
    • Rank transformations as a bridge between parametric and nonparametric statistics
    • Conover WJ, Iman RL. Rank transformations as a bridge between parametric and nonparametric statistics. America Statistics 1981;35:124-129.
    • (1981) America Statistics , vol.35 , pp. 124-129
    • Conover, W.J.1    Iman, R.L.2
  • 18
    • 0001131777 scopus 로고
    • Expected values of normal order statistics
    • Harter HL. Expected values of normal order statistics. Biometrika 1961;48:151-165.
    • (1961) Biometrika , vol.48 , pp. 151-165
    • Harter, H.L.1
  • 19
    • 48249153186 scopus 로고
    • Intraclass correlations: uses in assessing rater reliability
    • Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psych Bull 1979;86:420-428.
    • (1979) Psych Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 21
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy. A meta-analysis
    • Kosmopoulos V, Schizas C. Pedicle screw placement accuracy. A meta-analysis. Spine 2007;32:E111-E120.
    • (2007) Spine , vol.32 , pp. E111-E120
    • Kosmopoulos, V.1    Schizas, C.2
  • 22
    • 0036726784 scopus 로고    scopus 로고
    • Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement
    • Rao G, Brodke DS, Rondina M, et al. Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurg 2002;97:223-226.
    • (2002) J Neurosurg , vol.97 , pp. 223-226
    • Rao, G.1    Brodke, D.S.2    Rondina, M.3
  • 23
    • 12744268540 scopus 로고    scopus 로고
    • Accuracy of computed tomography in assessing thoracic pedicle screw malposition
    • Fayyazi AH, Hugate RR, Pennypacker J, et al. Accuracy of computed tomography in assessing thoracic pedicle screw malposition. J Spinal Disord Tech 2004;17:367-371.
    • (2004) J Spinal Disord Tech , vol.17 , pp. 367-371
    • Fayyazi, A.H.1    Hugate, R.R.2    Pennypacker, J.3
  • 24
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography
    • Farber GL, Place HM, Mazur RA, et al. Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 1995;20:1494-1499.
    • (1995) Spine , vol.20 , pp. 1494-1499
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3
  • 25
    • 0037099509 scopus 로고    scopus 로고
    • Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities
    • Belmont Jr PJ, Klemme WR, Robinson M, et al. Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities. Spine 2002;27:1558-1566.
    • (2002) Spine , vol.27 , pp. 1558-1566
    • Belmont, P.J.1    Klemme, W.R.2    Robinson, M.3
  • 26
    • 36248940132 scopus 로고    scopus 로고
    • Computed tomography evaluation of pedicle screws placed in the pediatric deformed spine over an 8-year period
    • Lehman Jr RA, Lenke LG, Keeler KA, et al. Computed tomography evaluation of pedicle screws placed in the pediatric deformed spine over an 8-year period. Spine 2007;32:2679-2684.
    • (2007) Spine , vol.32 , pp. 2679-2684
    • Lehman, R.A.1    Lenke, L.G.2    Keeler, K.A.3
  • 27
    • 0346155980 scopus 로고    scopus 로고
    • Volumetric spinal canal intrusion: a comparison between thoracic pedicle screws and thoracic hooks
    • Polly Jr DW, Potter BK, Kuklo T, et al. Volumetric spinal canal intrusion: a comparison between thoracic pedicle screws and thoracic hooks. Spine 2004;29:63-69.
    • (2004) Spine , vol.29 , pp. 63-69
    • Polly, D.W.1    Potter, B.K.2    Kuklo, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.