-
1
-
-
26044479492
-
Defining the learning curve for paramedic student endotracheal intubation
-
[CrossRef]
-
Wang HE, Seitz SR, Hostler D, Yealy DM. Defining the learning curve for paramedic student endotracheal intubation. Prehosp Emerg Care 2005; 9: 156-62. [CrossRef]
-
(2005)
Prehosp Emerg Care
, vol.9
, pp. 156-162
-
-
Wang, H.E.1
Seitz, S.R.2
Hostler, D.3
Yealy, D.M.4
-
2
-
-
0142247275
-
Effect of paramedic experience on orotracheal intubation success rates
-
[CrossRef]
-
Garza AG, Gratton MC, Coontz D, Noble E, Ma OJ. Effect of paramedic experience on orotracheal intubation success rates. J Emerg Med 2003; 25: 251-6. [CrossRef]
-
(2003)
J Emerg Med
, vol.25
, pp. 251-256
-
-
Garza, A.G.1
Gratton, M.C.2
Coontz, D.3
Noble, E.4
Ma, O.J.5
-
3
-
-
84863727073
-
Prospective model-based comparison of different laryngoscopes for difficult intubation in infants
-
[CrossRef]
-
Kalbhenn J, Boelke AK, Steinmann D. Prospective model-based comparison of different laryngoscopes for difficult intubation in infants. Paediatr Anaesth 2012; 22: 776-80. [CrossRef]
-
(2012)
Paediatr Anaesth
, vol.22
, pp. 776-780
-
-
Kalbhenn, J.1
Boelke, A.K.2
Steinmann, D.3
-
4
-
-
78651308095
-
The difficult pediatric airway--a review of new devices for indirect laryngoscopy in children younger than two years of age
-
[CrossRef]
-
Holm-Knudsen R. The difficult pediatric airway--a review of new devices for indirect laryngoscopy in children younger than two years of age. Paediatr Anaesth 2011; 21: 98-103. [CrossRef]
-
(2011)
Paediatr Anaesth
, vol.21
, pp. 98-103
-
-
Holm-Knudsen, R.1
-
5
-
-
84873461467
-
Our preliminary experience with LMA C-Trach
-
Swadia VN, Patel MG. Our preliminary experience with LMA C-Trach. Indian J Anaesth 2009; 53: 312-7.
-
(2009)
Indian J Anaesth
, vol.53
, pp. 312-317
-
-
Swadia, V.N.1
Patel, M.G.2
-
6
-
-
33244497122
-
The LMA CTrach, a new laryngeal mask airway for Endotracheal intubation under vision: Evaluation in 100 patients
-
[CrossRef]
-
Liu EHC, Goy RWL, Chen FG. The LMA CTrach, a new laryngeal mask airway for Endotracheal intubation under vision: evaluation in 100 patients. Br J Anaesth 2006; 96: 396-400. [CrossRef]
-
(2006)
Br J Anaesth
, vol.96
, pp. 396-400
-
-
Liu, E.1
Goy, R.2
Chen, F.G.3
-
7
-
-
33645278331
-
Evaluation of the CTrachan intubating LMA with integrated fibreoptic system
-
[CrossRef]
-
Timmermann A, Russo S, Graf BM. Evaluation of the CTrachan intubating LMA with integrated fibreoptic system. Br J Anaesth 2006; 96: 516-21. [CrossRef]
-
(2006)
Br J Anaesth
, vol.96
, pp. 516-521
-
-
Timmermann, A.1
Russo, S.2
Graf, B.M.3
-
8
-
-
33645778801
-
Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy--a manikin study
-
[CrossRef]
-
Maharaj CH, Higgins BD, Harte BH, Laffey JG. Evaluation of intubation using the Airtraq or Macintosh laryngoscope by anaesthetists in easy and simulated difficult laryngoscopy--a manikin study. Anaesthesia 2006; 61: 469-77. [CrossRef]
-
(2006)
Anaesthesia
, vol.61
, pp. 469-477
-
-
Maharaj, C.H.1
Higgins, B.D.2
Harte, B.H.3
Laffey, J.G.4
-
9
-
-
81755161321
-
Use of Airtraq, C-Mac, and Glidescope laryngoscope is better than Macintosh in novice medical students’ hands: A manikin study
-
[CrossRef]
-
Kaki AM, Almarakbi WA, Fawzi HM, Boker AM. Use of Airtraq, C-Mac, and Glidescope laryngoscope is better than Macintosh in novice medical students’ hands: A manikin study. Saudi J Anaesth 2011; 5: 376-81. [CrossRef]
-
(2011)
Saudi J Anaesth
, vol.5
, pp. 376-381
-
-
Kaki, A.M.1
Almarakbi, W.A.2
Fawzi, H.M.3
Boker, A.M.4
-
11
-
-
84863717268
-
Fujita. A comparison of the Pentax Airway Scope™ with the Airtraq™ in an infant manikin
-
[CrossRef]
-
Tampo A, Suzuki A, Sako S, Kunisawa T, Iwasaki H, Fujita. A comparison of the Pentax Airway Scope™ with the Airtraq™ in an infant manikin. Anaesthesia 2012; 67: 881-4. [CrossRef]
-
(2012)
Anaesthesia
, vol.67
, pp. 881-884
-
-
Tampo, A.1
Suzuki, A.2
Sako, S.3
Kunisawa, T.4
Iwasaki, H.5
-
12
-
-
84355166691
-
Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: A manikin study
-
[CrossRef]
-
Komasawa N, Ueki R, Kohama H, Nishi S, Kaminoh Y. Comparison of Pentax-AWS Airwayscope video laryngoscope, Airtraq optic laryngoscope, and Macintosh laryngoscope during cardiopulmonary resuscitation under cervical stabilization: a manikin study. J Anesth 2011; 25: 898-903. [CrossRef]
-
(2011)
J Anesth
, vol.25
, pp. 898-903
-
-
Komasawa, N.1
Ueki, R.2
Kohama, H.3
Nishi, S.4
Kaminoh, Y.5
-
13
-
-
77956159162
-
Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope andAirtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins
-
[CrossRef]
-
Maassen R, van Zundert A. Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope andAirtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins. Anaesthesia 2010; 65: 955-956. [CrossRef]
-
(2010)
Anaesthesia
, vol.65
, pp. 955-956
-
-
Maassen, R.1
Van Zundert, A.2
-
14
-
-
68849129139
-
Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: A manikin study
-
[CrossRef]
-
Savoldelli GL, Schiffer E, Abegg C, Baeriswyl V, Clergue F, Waeber JL. Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: a manikin study. Eur J Anaesthesiol 2009; 26: 554-8. [CrossRef]
-
(2009)
Eur J Anaesthesiol
, vol.26
, pp. 554-558
-
-
Savoldelli, G.L.1
Schiffer, E.2
Abegg, C.3
Baeriswyl, V.4
Clergue, F.5
Waeber, J.L.6
-
15
-
-
34748852519
-
Novices ventilate and intubate quicker and safer via intubating laryngeal mask than by conventional bagmask ventilation and laryngoscopy
-
[CrossRef]
-
Timmermann A, Russo SG, Crozier TA, Eich C, Mundt B, Albrecht B, et al. Novices ventilate and intubate quicker and safer via intubating laryngeal mask than by conventional bagmask ventilation and laryngoscopy. Anesthesiology 2007; 107: 570-6. [CrossRef]
-
(2007)
Anesthesiology
, vol.107
, pp. 570-576
-
-
Timmermann, A.1
Russo, S.G.2
Crozier, T.A.3
Eich, C.4
Mundt, B.5
Albrecht, B.6
-
16
-
-
33746484022
-
Guided insertion of the ProSeal laryngeal mask airway is superior to conventional tracheal intubation by first-month anesthesia residents after brief manikin-only training
-
[CrossRef]
-
Hohlrieder M, Brimacombe J, von Goedecke A, Keller C. Guided insertion of the ProSeal laryngeal mask airway is superior to conventional tracheal intubation by first-month anesthesia residents after brief manikin-only training. Anesth Analg 2006; 103: 458-62. [CrossRef]
-
(2006)
Anesth Analg
, vol.103
, pp. 458-462
-
-
Hohlrieder, M.1
Brimacombe, J.2
Von Goedecke, A.3
Keller, C.4
-
17
-
-
36849046763
-
Airtraq vs standard laryngoscopy by student paramedics and experienced prehospital laryngoscopists managing a model of difficult intubation
-
[CrossRef]
-
Woollard M, Lighton D, Mannion W, Watt J, McCrea C, Johns I, et al. Airtraq vs standard laryngoscopy by student paramedics and experienced prehospital laryngoscopists managing a model of difficult intubation. Anaesthesia 2008; 63: 26-31. [CrossRef]
-
(2008)
Anaesthesia
, vol.63
, pp. 26-31
-
-
Woollard, M.1
Lighton, D.2
Mannion, W.3
Watt, J.4
McCrea, C.5
Johns, I.6
-
18
-
-
61549087534
-
Airway management at floor level: A comparison of tracheal intubation using the Macintosh and Airtraq laryngoscopes
-
[CrossRef]
-
Tong JL, Gait AJ, Woollard M, Nightingale PG, Sharma MR. Airway management at floor level: a comparison of tracheal intubation using the Macintosh and Airtraq laryngoscopes. J R Army Med Corps 2008; 154: 21-5. [CrossRef]
-
(2008)
J R Army Med Corps
, vol.154
, pp. 21-25
-
-
Tong, J.L.1
Gait, A.J.2
Woollard, M.3
Nightingale, P.G.4
Sharma, M.R.5
-
19
-
-
84988361365
-
A Comparison of Macintosh and Airtraq Laryngoscopes for Endotracheal Intubation in Adult Patients With Cervical Spine Immobilization Using Manual In Line Axial Stabilization: A Prospective Randomized Study
-
Aug 28. [Epub ahead of print]
-
Vijayakumar V, Rao S, Shetty N. A Comparison of Macintosh and Airtraq Laryngoscopes for Endotracheal Intubation in Adult Patients With Cervical Spine Immobilization Using Manual In Line Axial Stabilization: A Prospective Randomized Study. J Neurosurg Anesthesiol 2015 Aug 28. [Epub ahead of print].
-
(2015)
J Neurosurg Anesthesiol
-
-
Vijayakumar, V.1
Rao, S.2
Shetty, N.3
-
20
-
-
84959885235
-
Alternative intubation techniques vs Macintosh laryngoscopy in patients with cervical spine immobilization: Systematic review and meta-analysis of randomized controlled trials
-
[CrossRef]
-
Suppan L, Tramèr MR, Niquille M, Grosgurin O, Marti C. Alternative intubation techniques vs Macintosh laryngoscopy in patients with cervical spine immobilization: systematic review and meta-analysis of randomized controlled trials. Br J Anaesth 2016; 116: 27-36. [CrossRef]
-
(2016)
Br J Anaesth
, vol.116
, pp. 27-36
-
-
Suppan, L.1
Tramèr, M.R.2
Niquille, M.3
Grosgurin, O.4
Marti, C.5
-
21
-
-
84873668408
-
Airtraq™ versus Macintoch laryngoscope in intubation performance in the pediatric population
-
[CrossRef]
-
Riad W, Moussa A, Wong DT. Airtraq™ versus Macintoch laryngoscope in intubation performance in the pediatric population. Saudi J Anaesth 2012; 6: 332-5. [CrossRef]
-
(2012)
Saudi J Anaesth
, vol.6
, pp. 332-335
-
-
Riad, W.1
Moussa, A.2
Wong, D.T.3
-
22
-
-
66149093148
-
Tracheal intubation in patients with cervical spine immobilization: A comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes
-
[CrossRef]
-
Malik MA, Subramaniam R, Churasia S, Maharaj CH, Harte BH, Laffey JG. Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope, LMA CTrach, and the Macintosh laryngoscopes. Br J Anaesth 2009; 102: 654-61. [CrossRef]
-
(2009)
Br J Anaesth
, vol.102
, pp. 654-661
-
-
Malik, M.A.1
Subramaniam, R.2
Churasia, S.3
Maharaj, C.H.4
Harte, B.H.5
Laffey, J.G.6
-
23
-
-
67650941346
-
Video-assisted versus conventional tracheal intubation in morbidly obese patients
-
[CrossRef]
-
Dhonneur G, Abdi W, Ndoko SK, Amathieu R, Risk N, El Housseini L, et al. Video-assisted versus conventional tracheal intubation in morbidly obese patients. Obes Surg 2009; 19: 1096-101. [CrossRef]
-
(2009)
Obes Surg
, vol.19
, pp. 1096-1101
-
-
Dhonneur, G.1
Abdi, W.2
Ndoko, S.K.3
Amathieu, R.4
Risk, N.5
El Housseini, L.6
-
24
-
-
84856874121
-
Tracheal intubation in morbidly obese patients: A comparison of the Intubating Laryngeal Mask Airway™ and Laryngeal Mask Airway CTrach™
-
[CrossRef]
-
Arslan ZI, Özdamar D, Yildiz TS, Solak ZM, Toker K. Tracheal intubation in morbidly obese patients: a comparison of the Intubating Laryngeal Mask Airway™ and Laryngeal Mask Airway CTrach™. Anaesthesia 2012; 67: 261-5. [CrossRef]
-
(2012)
Anaesthesia
, vol.67
, pp. 261-265
-
-
Arslan, Z.I.1
Özdamar, D.2
Yildiz, T.S.3
Solak, Z.M.4
Toker, K.5
-
25
-
-
84995624449
-
Orotracheal intubation of morbidly obese patients, comparison of GlideScope® video laryngoscope and the LMA CTrachTM with direct laryngoscopy
-
[CrossRef]
-
Yousef GT, Abdalgalil DA, Ibrahim TH. Orotracheal intubation of morbidly obese patients, comparison of GlideScope® video laryngoscope and the LMA CTrachTM with direct laryngoscopy. Anesth Essays Res 2012; 6: 174-9. [CrossRef]
-
(2012)
Anesth Essays Res
, vol.6
, pp. 174-179
-
-
Yousef, G.T.1
Abdalgalil, D.A.2
Ibrahim, T.H.3
-
26
-
-
84903372972
-
The use of Airtraq laryngoscope versus Macintosh laryngoscope and fiberoptic bronchoscope by experienced anesthesiologists
-
Saracoglu KT, Acarel M, Umuroglu T, Gogus FY. The use of Airtraq laryngoscope versus Macintosh laryngoscope and fiberoptic bronchoscope by experienced anesthesiologists. Middle East J Anaesthesiol 2014; 22: 503-9.
-
(2014)
Middle East J Anaesthesiol
, vol.22
, pp. 503-509
-
-
Saracoglu, K.T.1
Acarel, M.2
Umuroglu, T.3
Gogus, F.Y.4
-
27
-
-
70449633238
-
Tracheal intubation in patients with rigid collar immobilisation of the cervical spine: A comparison of Airtraq and LMA CTrach devices
-
[CrossRef]
-
Arslan ZI, Yildiz T, Baykara ZN, Solak M, Toker K. Tracheal intubation in patients with rigid collar immobilisation of the cervical spine: a comparison of Airtraq and LMA CTrach devices. Anaesthesia 2009; 64: 1332-6. [CrossRef]
-
(2009)
Anaesthesia
, vol.64
, pp. 1332-1336
-
-
Arslan, Z.I.1
Yildiz, T.2
Baykara, Z.N.3
Solak, M.4
Toker, K.5
-
28
-
-
80955146123
-
Airtraq laryngoscope versus conventional Macintosh laryngoscope: A systematic review and meta-analysis
-
[CrossRef]
-
Lu Y, Jiang H, Zhu YS. Airtraq laryngoscope versus conventional Macintosh laryngoscope: a systematic review and meta-analysis. Anaesthesia 2011; 66: 1160-7. [CrossRef]
-
(2011)
Anaesthesia
, vol.66
, pp. 1160-1167
-
-
Lu, Y.1
Jiang, H.2
Zhu, Y.S.3
-
29
-
-
38949159274
-
Tracheal intubation of morbidly obese patients: A randomized trial comparing performance of Macintosh and Airtraq laryngoscopes
-
[CrossRef]
-
Ndoko SK, Amathieu R, Tual L, Polliand C, Kamoun W, El Housseini L, et al. Tracheal intubation of morbidly obese patients: a randomized trial comparing performance of Macintosh and Airtraq laryngoscopes. Br J Anaesth. 2008; 100: 263-8. [CrossRef]
-
(2008)
Br J Anaesth
, vol.100
, pp. 263-268
-
-
Ndoko, S.K.1
Amathieu, R.2
Tual, L.3
Polliand, C.4
Kamoun, W.5
El Housseini, L.6
|