메뉴 건너뛰기




Volumn 21, Issue 2, 2011, Pages 98-103

The difficult pediatric airway - A review of new devices for indirect laryngoscopy in children younger than two years of age

Author keywords

airway device; children; difficult airway; indirect laryngoscopy; infant

Indexed keywords

CAMERA; CHILD; COST; ENDOTRACHEAL INTUBATION; FIBER OPTICS; GLOTTIS; GROUPS BY AGE; HUMAN; IMAGE DISPLAY; INFANT; LARYNGOSCOPE; LARYNGOSCOPY; MEDICAL DECISION MAKING; MOUTH; PRESCHOOL CHILD; PRIORITY JOURNAL; REVIEW; TECHNIQUE;

EID: 78651308095     PISSN: 11555645     EISSN: 14609592     Source Type: Journal    
DOI: 10.1111/j.1460-9592.2010.03487.x     Document Type: Review
Times cited : (90)

References (16)
  • 1
    • 67149123641 scopus 로고    scopus 로고
    • Airtraq optical laryngoscope intubation in a 5-month-old infant with a difficult airway because of Robin Sequence
    • Vlatten A, Soder C,. Airtraq optical laryngoscope intubation in a 5-month-old infant with a difficult airway because of Robin Sequence. Pediatr Anesth 2009; 19: 699-700.
    • (2009) Pediatr Anesth , vol.19 , pp. 699-700
    • Vlatten, A.1    Soder, C.2
  • 2
    • 77949293999 scopus 로고    scopus 로고
    • The Airtraq may not be the solution for infants with difficult airways
    • Holm-Knudsen RJ, White J,. The Airtraq may not be the solution for infants with difficult airways. Pediatr Anesth 2010; 20: 374-375.
    • (2010) Pediatr Anesth , vol.20 , pp. 374-375
    • Holm-Knudsen, R.J.1    White, J.2
  • 3
    • 68849092484 scopus 로고    scopus 로고
    • More maneuvers to facilitate endotracheal intubation using the Airtraq laryngoscope in children with difficult airways
    • Xue FS, He N, Liu JH, et al. More maneuvers to facilitate endotracheal intubation using the Airtraq laryngoscope in children with difficult airways. Pediatr Anesth 2009; 19: 916-918.
    • (2009) Pediatr Anesth , vol.19 , pp. 916-918
    • Xue, F.S.1    He, N.2    Liu, J.H.3
  • 4
    • 51849124729 scopus 로고    scopus 로고
    • GlideScopew video laryngoscope: A randomized clinical trial in 203 paediatric patients
    • Kim J-T, Na H-S, Bae J-Y, et al. GlideScopew video laryngoscope: a randomized clinical trial in 203 paediatric patients. Br J Anaesth 2008; 101: 531-534.
    • (2008) Br J Anaesth , vol.101 , pp. 531-534
    • Kim, J.-T.1    Na, H.-S.2    Bae, J.-Y.3
  • 5
    • 67149116779 scopus 로고    scopus 로고
    • Validation of the glidescope video laryngoscope in pediatric patients
    • Redel A, Karademir F, Schlitterlau A, et al. Validation of the glidescope video laryngoscope in pediatric patients. Pediatr Anesth 2009; 19: 667-671.
    • (2009) Pediatr Anesth , vol.19 , pp. 667-671
    • Redel, A.1    Karademir, F.2    Schlitterlau, A.3
  • 7
    • 67651219263 scopus 로고    scopus 로고
    • Early clinical experience with Glide-Scope video laryngoscope in 20 infants
    • Hirabayashi Y, Otsuka Y,. Early clinical experience with Glide-Scope video laryngoscope in 20 infants. Pediatr Anesth 2009; 19: 800-814.
    • (2009) Pediatr Anesth , vol.19 , pp. 800-814
    • Hirabayashi, Y.1    Otsuka, Y.2
  • 8
    • 67749084288 scopus 로고    scopus 로고
    • A videolaryngoscopy technique for the intubation of the newborn
    • Vanderhal AL, Berci G, Simmons CF, et al. A videolaryngoscopy technique for the intubation of the newborn. Pediatrics 2009; 124: e339-e346.
    • (2009) Pediatrics , vol.124
    • Vanderhal, A.L.1    Berci, G.2    Simmons, C.F.3
  • 9
    • 70350540440 scopus 로고    scopus 로고
    • A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway
    • Vlatten A, Aucoin S, Litz S, et al. A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway. Pediatr Anesth 2009; 19: 1102-1107.
    • (2009) Pediatr Anesth , vol.19 , pp. 1102-1107
    • Vlatten, A.1    Aucoin, S.2    Litz, S.3
  • 10
    • 70149089046 scopus 로고    scopus 로고
    • Management of the difficult infant airway with the STORZ video laryngoscope: A case series
    • Hackell RS, Held LD, Stricker PA, et al. Management of the difficult infant airway with the STORZ video laryngoscope: a case series. Anesth Analg 2009; 109: 763-766.
    • (2009) Anesth Analg , vol.109 , pp. 763-766
    • Hackell, R.S.1    Held, L.D.2    Stricker, P.A.3
  • 11
    • 47349083367 scopus 로고    scopus 로고
    • Pediatric video laryngoscope rescue for a difficult neonatal intubation
    • Wald SH, Keyes M, Brown A,. Pediatric video laryngoscope rescue for a difficult neonatal intubation. Pediatr Anesth 2008; 18: 790-792.
    • (2008) Pediatr Anesth , vol.18 , pp. 790-792
    • Wald, S.H.1    Keyes, M.2    Brown, A.3
  • 12
    • 67149099421 scopus 로고    scopus 로고
    • Difficult airway management with the STORZ video laryngoscope in a child with Robin Sequence
    • Vlatten A, Aucoin S, Gray A, et al. Difficult airway management with the STORZ video laryngoscope in a child with Robin Sequence. Pediatr Anesth 2009; 19: 700-701.
    • (2009) Pediatr Anesth , vol.19 , pp. 700-701
    • Vlatten, A.1    Aucoin, S.2    Gray, A.3
  • 13
    • 62449325074 scopus 로고    scopus 로고
    • A comparison of Truview infant EVO2 laryngoscope with the Miller blade in neonates and infants
    • Singh R, Singh H, Vajifdar H,. A comparison of Truview infant EVO2 laryngoscope with the Miller blade in neonates and infants. Pediatr Anesth 2009; 19: 338-342.
    • (2009) Pediatr Anesth , vol.19 , pp. 338-342
    • Singh, R.1    Singh, H.2    Vajifdar, H.3
  • 14
    • 33846605602 scopus 로고    scopus 로고
    • Complications associated with the use of the GlideScope videolaryngoscope
    • Cooper RM,. Complications associated with the use of the GlideScope videolaryngoscope. Can J Anaesth 2007; 54: 154-157.
    • (2007) Can J Anaesth , vol.54 , pp. 154-157
    • Cooper, R.M.1
  • 15
    • 56649083451 scopus 로고    scopus 로고
    • Palatopharyngeal wall perforation during Glidescope intubation
    • Leong WL, Lim Y, Sia AT,. Palatopharyngeal wall perforation during Glidescope intubation. Anaesth Intensive Care 2008; 36: 870-874.
    • (2008) Anaesth Intensive Care , vol.36 , pp. 870-874
    • Leong, W.L.1    Lim, Y.2    Sia, A.T.3
  • 16
    • 68849098376 scopus 로고    scopus 로고
    • Facilitating endotracheal intubation using the GlideScope video laryngoscope in children with difficult airways
    • Xue FS, Liu HP, Liu JH, et al. Facilitating endotracheal intubation using the GlideScope video laryngoscope in children with difficult airways. Pediatr Anesth 2009; 19: 918-919.
    • (2009) Pediatr Anesth , vol.19 , pp. 918-919
    • Xue, F.S.1    Liu, H.P.2    Liu, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.