-
1
-
-
33750114162
-
Technological approaches to determining proper placement of enteral feeding tubes
-
[1559-7768]
-
Ackerman MH, Mick DJ. Technological approaches to determining proper placement of enteral feeding tubes. AACN Advanced Critical Care 2006;17(3):246-9. [: 1559-7768]
-
(2006)
AACN Advanced Critical Care
, vol.17
, Issue.3
, pp. 246-249
-
-
Ackerman, M.H.1
Mick, D.J.2
-
2
-
-
0037666990
-
Capnography application in acute and critical care
-
[PUBMED: 12819450]
-
Ahrens T, Sona C. Capnography application in acute and critical care. AACN Clinical Issues 2003;14(2):123-32. [PUBMED: 12819450]
-
(2003)
AACN Clinical Issues
, vol.14
, Issue.2
, pp. 123-132
-
-
Ahrens, T.1
Sona, C.2
-
4
-
-
0036799769
-
Use of capnometry to verify feeding tube placement
-
PUBMED: 12394953]
-
Araujo-Preza CE, Melhado ME, Gutierrez FJ, Maniatis T, Castallano MA. Use of capnometry to verify feeding tube placement. Critical Care Medicine 2002;30(10):2255-9. [PUBMED: 12394953]
-
(2002)
Critical Care Medicine
, vol.30
, Issue.10
, pp. 2255-2259
-
-
Araujo-Preza, C.E.1
Melhado, M.E.2
Gutierrez, F.J.3
Maniatis, T.4
Castallano, M.A.5
-
5
-
-
60849110307
-
Feeding tube placement in adults: safe verification method for blindly inserted tubes
-
[PUBMED: 19116408]
-
Bourgault AM, Halm MA. Feeding tube placement in adults: safe verification method for blindly inserted tubes. American Journal of Critical Care 2009;18(1):73-6. [PUBMED: 19116408]
-
(2009)
American Journal of Critical Care
, vol.18
, Issue.1
, pp. 73-76
-
-
Bourgault, A.M.1
Halm, M.A.2
-
6
-
-
0035004191
-
Report on the development of a procedure to prevent placement of feeding tubes into the lungs using end tidal CO2 measurements
-
PUBMED: 11378600]
-
Burns SM, Carpenter R, Truwit JD. Report on the development of a procedure to prevent placement of feeding tubes into the lungs using end tidal CO2 measurements. Critical Care Medicine 2001;29(5):936-9. [PUBMED: 11378600]
-
(2001)
Critical Care Medicine
, vol.29
, Issue.5
, pp. 936-939
-
-
Burns, S.M.1
Carpenter, R.2
Truwit, J.D.3
-
7
-
-
33745033079
-
Detection of inadvertent airway intubation during gastric tube insertion: capnography versus a colorimetric carbon dioxide detector
-
PUBMED: 16501138]
-
Burns SM, Carpenter R, Blevins C, Bragg S, Marshall M, Browne L, et al.Detection of inadvertent airway intubation during gastric tube insertion: capnography versus a colorimetric carbon dioxide detector. American Journal of Critical Care 2006;15(2):188-95. [PUBMED: 16501138]
-
(2006)
American Journal of Critical Care
, vol.15
, Issue.2
, pp. 188-195
-
-
Burns, S.M.1
Carpenter, R.2
Blevins, C.3
Bragg, S.4
Marshall, M.5
Browne, L.6
-
8
-
-
79953160839
-
Use of end tidal carbon dioxide to determine correct placement of nasogastric tube: a meta analysis
-
PUBMED: 21215969]
-
Chau JPC, Lo SHS, Thompson DR, Fernandez R, Griffiths R. Use of end tidal carbon dioxide to determine correct placement of nasogastric tube: a meta analysis. International Journal of Nursing Studies 2011;48(4):513-21. [PUBMED: 21215969]
-
(2011)
International Journal of Nursing Studies
, vol.48
, Issue.4
, pp. 513-521
-
-
Chau, J.P.C.1
Lo, S.H.S.2
Thompson, D.R.3
Fernandez, R.4
Griffiths, R.5
-
9
-
-
85159265139
-
Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy Version 1.0
-
editors
-
Deeks JJ, Bossuyt PM, Gatsonis C (editors). Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy Version 1.0. The Cochrane Collaboration, 2010. Available from: http://srdta.cochrane.org/.
-
(2010)
The Cochrane Collaboration
-
-
Deeks, J.J.1
Bossuyt, P.M.2
Gatsonis, C.3
-
10
-
-
80053068842
-
Nasogastric tube insertion in difficult cases with the aid of a flexible nasendoscope
-
PUBMED: 21729448 ]
-
Der Kureghian J, Kumar S, Jani P. Nasogastric tube insertion in difficult cases with the aid of a flexible nasendoscope. The Journal of Laryngology & Otology 2011;125(9):962-4. [PUBMED: 21729448 ]
-
(2011)
The Journal of Laryngology & Otology
, vol.125
, Issue.9
, pp. 962-964
-
-
Der Kureghian, J.1
Kumar, S.2
Jani, P.3
-
11
-
-
67449102226
-
Nasogastric tubes 1: Insertion technique and confirming position
-
PUBMED: 19480158]
-
Durai R, Venkatran R, Ng PHC. Nasogastric tubes 1: Insertion technique and confirming position. Nursing Times 2009;105(6):12-3. [PUBMED: 19480158]
-
(2009)
Nursing Times
, vol.105
, Issue.6
, pp. 12-13
-
-
Durai, R.1
Venkatran, R.2
Ng, P.H.C.3
-
12
-
-
40449108616
-
Capnometry and air insufflation for assessing initial placement of gastric tubes
-
PUBMED: 17962498]
-
Elpern EH, Killeen K, Talla E, Perez G, Gurka D. Capnometry and air insufflation for assessing initial placement of gastric tubes. American Journal of Critical Care 2007;16(6):544-9. [PUBMED: 17962498]
-
(2007)
American Journal of Critical Care
, vol.16
, Issue.6
, pp. 544-549
-
-
Elpern, E.H.1
Killeen, K.2
Talla, E.3
Perez, G.4
Gurka, D.5
-
13
-
-
80054986501
-
Nutrition: safe practice in adult enteral tube feeding
-
[PUBMED: 22067835]
-
Fletcher J. Nutrition: safe practice in adult enteral tube feeding. British Journal of Nursing 2011;20(19):234-9. [PUBMED: 22067835]
-
(2011)
British Journal of Nursing
, vol.20
, Issue.19
, pp. 234-239
-
-
Fletcher, J.1
-
14
-
-
19244374452
-
Measuring end tidal carbon dioxide: clinical implications and usefulness
-
[PUBMED: 11855600]
-
Frakes MA. Measuring end tidal carbon dioxide: clinical implications and usefulness. Critical Care Nurse 2001;21(5):23-6. [PUBMED: 11855600]
-
(2001)
Critical Care Nurse
, vol.21
, Issue.5
, pp. 23-26
-
-
Frakes, M.A.1
-
15
-
-
84908201413
-
Improving the safety of nasogastric feeding tube insertion: A Report for the NHS Patient Safety Research Portfolio
-
July 2010
-
Hanna G, Phillips L, Priest O, Ni Z. Improving the safety of nasogastric feeding tube insertion: A Report for the NHS Patient Safety Research Portfolio. Available from http://www.birmingham.ac.uk/Documents/college-mds/haps/projects/cfhep/psrp/finalreports/PS048ImprovingthesafetyofnasogastricfeedingtubeinsertionREVISEDHannaetal.pdf July 2010.
-
-
-
Hanna, G.1
Phillips, L.2
Priest, O.3
Ni, Z.4
-
16
-
-
63849105841
-
Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]
-
editors
-
Higgins JPT, Green S (editors). Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 [updated March 2011]. The Cochrane Collaboration, 2011. Available from www.cochrane-handbook.org.
-
(2011)
The Cochrane Collaboration
-
-
Higgins, J.P.T.1
Green, S.2
-
17
-
-
0034971884
-
A controlled comparison of traditional feeding tube verification methods to a bedside, electromagnetic technique
-
PUBMED: 11434652]
-
Kearns, PJ, DOnna, C. A controlled comparison of traditional feeding tube verification methods to a bedside, electromagnetic technique. Journal of Parenteral and Enteral Nutrition 2001;25(4):210-5. [PUBMED: 11434652]
-
(2001)
Journal of Parenteral and Enteral Nutrition
, vol.25
, Issue.4
, pp. 210-215
-
-
Kearns, P.J.1
Onna, C.2
-
18
-
-
0034826908
-
Capnography confirms correct feeding tube placement in intensive care unit patients
-
PUBMED: 11495882]
-
Kindopp AS, Drover JW, Heyland DK. Capnography confirms correct feeding tube placement in intensive care unit patients. Canadian Journal of Anaesthesia 2001;48(7):705-10. [PUBMED: 11495882]
-
(2001)
Canadian Journal of Anaesthesia
, vol.48
, Issue.7
, pp. 705-710
-
-
Kindopp, A.S.1
Drover, J.W.2
Heyland, D.K.3
-
19
-
-
79955955096
-
Checking placement of nasogastric feeding tubes in adults (interpretation of x-ray images): summary of a patient safety report from the National Patient Safety Agency
-
PUBMED: 21546422
-
Lamont T, Beaumont C, Fayaz A, Healey F, Huehns T, Law R, et al.Checking placement of nasogastric feeding tubes in adults (interpretation of x-ray images): summary of a patient safety report from the National Patient Safety Agency. BMJ 2011;342:d2586. [DOI: 10.1136/bmj.d2586; PUBMED: 21546422]
-
(2011)
BMJ
, vol.342
-
-
Lamont, T.1
Beaumont, C.2
Fayaz, A.3
Healey, F.4
Huehns, T.5
Law, R.6
-
20
-
-
0003518673
-
Determining NG tube position (letter)
-
Mercurio P, Leven P. Determining NG tube position (letter). Respiratory Care 1985;30:999.
-
(1985)
Respiratory Care
, vol.30
, pp. 999
-
-
Mercurio, P.1
Leven, P.2
-
21
-
-
0030955368
-
pH concentrations of pepsin and trypsin in feeding tube aspirates as predictors of tube placement
-
PUBMED: 9323690]
-
Metheny NA, Stewart BJ, Smith L, Yan H, Diebold M, Clouse RE. pH concentrations of pepsin and trypsin in feeding tube aspirates as predictors of tube placement. Journal of Parenteral and Enteral Nutrition 1997;21(5):279-85. [PUBMED: 9323690]
-
(1997)
Journal of Parenteral and Enteral Nutrition
, vol.21
, Issue.5
, pp. 279-285
-
-
Metheny, N.A.1
Stewart, B.J.2
Smith, L.3
Yan, H.4
Diebold, M.5
Clouse, R.E.6
-
22
-
-
0040027137
-
Assessing placement of feeding tubes
-
[PUBMED: 11355494]
-
Metheny NA, Titler G. Assessing placement of feeding tubes. American Journal of Nursing 2001;101(5):36-45. [PUBMED: 11355494]
-
(2001)
American Journal of Nursing
, vol.101
, Issue.5
, pp. 36-45
-
-
Metheny, N.A.1
Titler, G.2
-
23
-
-
67349216361
-
Colorimetric capnography to ensure correct nasogastric tube position
-
PUBMED: 19327299]
-
Meyer P, Henry M, Maury E, Baudel J, Guidet B, Offenstadt G. Colorimetric capnography to ensure correct nasogastric tube position. Journal of Critical Care 2009;24(2):231-5. [PUBMED: 19327299]
-
(2009)
Journal of Critical Care
, vol.24
, Issue.2
, pp. 231-235
-
-
Meyer, P.1
Henry, M.2
Maury, E.3
Baudel, J.4
Guidet, B.5
Offenstadt, G.6
-
24
-
-
79952839878
-
Capnometry vs. pH testing in nasogastric tube placement
-
[1479-5248]
-
Miller SL. Capnometry vs. pH testing in nasogastric tube placement. Gastrointestinal Nursing 2011;9(2):30-3. [: 1479-5248]
-
(2011)
Gastrointestinal Nursing
, vol.9
, Issue.2
, pp. 30-33
-
-
Miller, S.L.1
-
28
-
-
24944498883
-
Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews
-
PUBMED: 16168343]
-
Reitsma JB, Glas AS, Rutjes AWS, Scholten RJPM, Bossuyt PM, Zwinderman AH. Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. Journal of Clinical Epidemiology 2005;58(10):982-90. [PUBMED: 16168343]
-
(2005)
Journal of Clinical Epidemiology
, vol.58
, Issue.10
, pp. 982-990
-
-
Reitsma, J.B.1
Glas, A.S.2
Rutjes, A.W.S.3
Scholten, R.J.P.M.4
Bossuyt, P.M.5
Zwinderman, A.H.6
-
29
-
-
34948863413
-
Devices and techniques for bedside enteral feeding tube placement
-
MEDLINE: 17644695]
-
Roberts S, Echeverria P, Gabriel SA. Devices and techniques for bedside enteral feeding tube placement. Nutrition in Clinical Practice 2007;22(4):412-20. [MEDLINE: 17644695]
-
(2007)
Nutrition in Clinical Practice
, vol.22
, Issue.4
, pp. 412-420
-
-
Roberts, S.1
Echeverria, P.2
Gabriel, S.A.3
-
30
-
-
84856610363
-
Bedside assessment of enteral tube placement: aligning practice with evidence
-
[PUBMED: 22261653]
-
Simons SR, Abdallah LM. Bedside assessment of enteral tube placement: aligning practice with evidence. American Journal of Nursing 2012;112(2):40-6. [PUBMED: 22261653]
-
(2012)
American Journal of Nursing
, vol.112
, Issue.2
, pp. 40-46
-
-
Simons, S.R.1
Abdallah, L.M.2
-
31
-
-
80052832607
-
-
London: The Intensive Care Society
-
The Intensive Care Society. Standards for Capnography in Critical Care. London: The Intensive Care Society, 2009.
-
(2009)
Standards for Capnography in Critical Care
-
-
-
32
-
-
0031898618
-
Confirmation of nasogastric tube placement by colorimetric indicator detection of carbon dioxide: a preliminary report
-
[PUBMED: 9550464]
-
Thomas BW, Falcone RE. Confirmation of nasogastric tube placement by colorimetric indicator detection of carbon dioxide: a preliminary report. Journal of the America College of Nutrition 1998;7(2):195-7. [PUBMED: 9550464]
-
(1998)
Journal of the America College of Nutrition
, vol.7
, Issue.2
, pp. 195-197
-
-
Thomas, B.W.1
Falcone, R.E.2
-
33
-
-
80055071671
-
The latest ASA mandate:CO2 monitoring for moderate and deep sedation
-
[PMC3167153]
-
Weaver J. The latest ASA mandate:CO2 monitoring for moderate and deep sedation. Anesthesia Progress 2011;58(3):111-2. [: PMC3167153]
-
(2011)
Anesthesia Progress
, vol.58
, Issue.3
, pp. 111-112
-
-
Weaver, J.1
-
34
-
-
80054740636
-
QUADAS-2: A revised tool for the Quality Assessment of Diagnostic Accuracy Studies
-
PUBMED: 22007046]
-
Whiting PF, Rutjes AWS, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al.QUADAS-2: A revised tool for the Quality Assessment of Diagnostic Accuracy Studies. Annals of Internal Medicine 2011;155(8):529-36. [PUBMED: 22007046]
-
(2011)
Annals of Internal Medicine
, vol.155
, Issue.8
, pp. 529-536
-
-
Whiting, P.F.1
Rutjes, A.W.S.2
Westwood, M.E.3
Mallett, S.4
Deeks, J.J.5
Reitsma, J.B.6
-
35
-
-
85040442133
-
Quality assessment in DTA reviews - February 2012 update
-
14th February 2012
-
Wisniewski S. Quality assessment in DTA reviews - February 2012 update. Available from http://srdta.cochrane.org/news/quality-assessment-dta-reviews-%E2%80%93-february-2012-update 14th February 2012.
-
-
-
Wisniewski, S.1
|