-
1
-
-
3042656957
-
Patient safety: effects of institutional protocols on adverse events related to feeding tube placement in the critically ill
-
Marderstein EL, Simmons RL, Ochoa JB. Patient safety: effects of institutional protocols on adverse events related to feeding tube placement in the critically ill. J Am Coll Surg. 2004;199(1):39-50.
-
(2004)
J Am Coll Surg
, vol.199
, Issue.1
, pp. 39-50
-
-
Marderstein, E.L.1
Simmons, R.L.2
Ochoa, J.B.3
-
2
-
-
33745033079
-
Detection of inadvertent airway intubation during gastric tube insertion: capnography versus a colorimetric carbon dioxide detector
-
Burns SM, Carpenter R, Blevins C, et al. Detection of inadvertent airway intubation during gastric tube insertion: capnography versus a colorimetric carbon dioxide detector. Am J Crit Care. 2006;15(2):188-195.
-
(2006)
Am J Crit Care
, vol.15
, Issue.2
, pp. 188-195
-
-
Burns, S.M.1
Carpenter, R.2
Blevins, C.3
-
4
-
-
14744277229
-
What is known about methods of correctly placing gastric tubes in adults and children
-
Ellett ML. What is known about methods of correctly placing gastric tubes in adults and children. Gastroenterol Nurs. 2004;27(6):253-259.
-
(2004)
Gastroenterol Nurs
, vol.27
, Issue.6
, pp. 253-259
-
-
Ellett, M.L.1
-
5
-
-
0028524621
-
Effectiveness of pH measurements in predicting feeding tube placement: an update
-
Metheny NA, Reed L, Wiersema L, et al. Effectiveness of pH measurements in predicting feeding tube placement: an update. Nutr Clin Prac. 1994;9:185-190.
-
(1994)
Nutr Clin Prac
, vol.9
, pp. 185-190
-
-
Metheny, N.A.1
Reed, L.2
Wiersema, L.3
-
6
-
-
0028046492
-
Pulmonary complications of feeding tubes: a new technique of insertion and monitoring malposition
-
D'Souza CR, Kilam SA, D'Souza U, Janzen EP, Sipos RA. Pulmonary complications of feeding tubes: a new technique of insertion and monitoring malposition. Can J Surg. 1994;37(5):404-408.
-
(1994)
Can J Surg
, vol.37
, Issue.5
, pp. 404-408
-
-
D'Souza, C.R.1
Kilam, S.A.2
D'Souza, U.3
Janzen, E.P.4
Sipos, R.A.5
-
7
-
-
0034826908
-
Capnography confirms correct feeding tube placement in intensive care patients
-
Kindopp AS, Drover JW, Heyland DK. Capnography confirms correct feeding tube placement in intensive care patients. Can J Anaesth. 2001;48(7):705-710.
-
(2001)
Can J Anaesth
, vol.48
, Issue.7
, pp. 705-710
-
-
Kindopp, A.S.1
Drover, J.W.2
Heyland, D.K.3
-
8
-
-
0035004191
-
2 measurements
-
Burns SM, Carpenter R, Truwit JD. Report on the development of a procedure to prevent placement of feeding tubes into the lungs using end-tidal CO2 measurements. Crit Care Med. 2001;29:936-939.
-
(2001)
Crit Care Med
, vol.29
, pp. 936-939
-
-
Burns, S.M.1
Carpenter, R.2
Truwit, J.D.3
-
9
-
-
0031898618
-
Confirmation of nasogastric tube placement by colorimetric detection of carbon dioxide: a preliminary report
-
Thomas BW, Falcone RE. Confirmation of nasogastric tube placement by colorimetric detection of carbon dioxide: a preliminary report. J Am Coll Nutr. 2001;17:195-197.
-
(2001)
J Am Coll Nutr
, vol.17
, pp. 195-197
-
-
Thomas, B.W.1
Falcone, R.E.2
-
10
-
-
0036799769
-
Use of capnometry to verify feeding tube position
-
Araujo-Preza CE, Melhado ME, Gutierrez FJ, Maniatis T, Castellano MA. Use of capnometry to verify feeding tube position. Crit Care Med. 2002;30:2255-2259.
-
(2002)
Crit Care Med
, vol.30
, pp. 2255-2259
-
-
Araujo-Preza, C.E.1
Melhado, M.E.2
Gutierrez, F.J.3
Maniatis, T.4
Castellano, M.A.5
-
11
-
-
58149476298
-
-
American Association of Critical-Care Nurses. Practice alert: verification of feeding tube placement. http://www.aacn.org/AACN/practiceAlert.nsf/vwdoc/pa2. Published May 2005. Accessed August 5
-
American Association of Critical-Care Nurses. Practice alert: verification of feeding tube placement. http://www.aacn.org/AACN/practiceAlert.nsf/vwdoc/pa2. Published May 2005. Accessed August 5, 2007.
-
(2007)
-
-
-
12
-
-
58149477800
-
-
Easy Cap II [package insert]. Pleasanton, CA: Nellcor Puritan Bennett Inc
-
Easy Cap II [package insert]. Pleasanton, CA: Nellcor Puritan Bennett Inc; 2002.
-
(2002)
-
-
-
13
-
-
0036237721
-
Rapid detection of oesophageal intubation: take care when using colorimetric capnometry
-
Puntervoll SA, Soreide E, Jacewicz W, Bjelland E. Rapid detection of oesophageal intubation: take care when using colorimetric capnometry. Acta Anaesthesiol Scand. 2002;46:455-457.
-
(2002)
Acta Anaesthesiol Scand
, vol.46
, pp. 455-457
-
-
Puntervoll, S.A.1
Soreide, E.2
Jacewicz, W.3
Bjelland, E.4
-
14
-
-
12344335708
-
The effect of vinegar on colorimetric end-tidal carbon dioxide determination after esophageal intubation
-
Leong MT, Ghebrial J, Sturmann K, Hsu CK. The effect of vinegar on colorimetric end-tidal carbon dioxide determination after esophageal intubation. J Emerg Med. 2005;28(1):5-11.
-
(2005)
J Emerg Med
, vol.28
, Issue.1
, pp. 5-11
-
-
Leong, M.T.1
Ghebrial, J.2
Sturmann, K.3
Hsu, C.K.4
-
15
-
-
13444272134
-
Malpositioning of fine bore feeding tube: a serious complication
-
Kawati R, Rubertsson S. Malpositioning of fine bore feeding tube: a serious complication. Acta Anaesthesiol Scand. 2005;49(1):58-61.
-
(2005)
Acta Anaesthesiol Scand
, vol.49
, Issue.1
, pp. 58-61
-
-
Kawati, R.1
Rubertsson, S.2
-
16
-
-
0040027137
-
Assessing placement of feeding tubes
-
Metheny NA, Titler MG. Assessing placement of feeding tubes. Am J Nurs. 2001;101(5):36-45.
-
(2001)
Am J Nurs
, vol.101
, Issue.5
, pp. 36-45
-
-
Metheny, N.A.1
Titler, M.G.2
|