Volumn , Issue , 2016, Pages 232-235

False arrhythmia alarm reduction in the intensive care unit using data fusion and machine learning

Author keywords

[No Author keywords available]

Indexed keywords

ALARM SYSTEMS; ALGORITHMS; ARTIFICIAL INTELLIGENCE; BLOOD PRESSURE; DATA FUSION; DISEASES; ELECTROCARDIOGRAPHY; GENETIC ALGORITHMS; INFORMATION SCIENCE; INTENSIVE CARE UNITS; LEARNING ALGORITHMS; LEARNING SYSTEMS; SPECTRUM ANALYSIS; SUPPORT VECTOR MACHINES;

EID: 84968611277     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BHI.2016.7455877     Document Type: Conference Paper
Times cited : (9)

References (11)
  • 1
    • 0028300877 scopus 로고
    • Crying Wolf: False alarms in a pediatric intensive care unit
    • Lawless, Stephen T. "Crying wolf: false alarms in a pediatric intensive care unit. " Critical care medicine 22. 6 (1994): 981-985.
    • (1994) Critical Care Medicine , vol.22 , Issue.6 , pp. 981-985
    • Lawless, S.T.1
  • 2
    • 0036667403 scopus 로고    scopus 로고
    • The hostile environment of the intensive care unit
    • Donchin, Yoel, and F. Jacob Seagull. "The hostile environment of the intensive care unit. " Current opinion in critical care 8. 4 (2002): 316-320.
    • (2002) Current Opinion in Critical Care , vol.8 , Issue.4 , pp. 316-320
    • Donchin, Y.1    Jacob Seagull, F.2
  • 3
    • 84875371266 scopus 로고    scopus 로고
    • Patient monitoring alarms in the ICU and in the operating room
    • Schmid, Felix, Matthias S. Goepfert, and Daniel A. Reuter. "Patient monitoring alarms in the ICU and in the operating room. " Crit Care 17. 2 (2013): 216.
    • (2013) Crit Care , vol.17 , Issue.2 , pp. 216
    • Schmid, F.1    Goepfert, M.S.2    Reuter, D.A.3
  • 4
    • 44549086481 scopus 로고    scopus 로고
    • Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform
    • Aboukhalil, Anton, et al. "Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform. " Journal of biomedical informatics 41. 3 (2008): 442-451.
    • (2008) Journal of Biomedical Informatics , vol.41 , Issue.3 , pp. 442-451
    • Aboukhalil, A.1
  • 6
    • 80053213729 scopus 로고    scopus 로고
    • Life-threatening arrhythmia verification in ICU patients using the joint cardiovascular dynamical model and a Bayesian filter
    • Sayadi, Omid, and Mohammad BagherShamsollahi. "Life-threatening arrhythmia verification in ICU patients using the joint cardiovascular dynamical model and a Bayesian filter. " Biomedical Engineering, IEEE Transactions on 58. 10 (2011): 2748-2757.
    • (2011) Biomedical Engineering, IEEE Transactions on , vol.58 , Issue.10 , pp. 2748-2757
    • Sayadi, O.1    BagherShamsollahi, M.2
  • 7
    • 84867842919 scopus 로고    scopus 로고
    • Signal quality and data fusion for false alarm reduction in the intensive care unit
    • Li, Qiao, and Gari D. Clifford. "Signal quality and data fusion for false alarm reduction in the intensive care unit. " Journal of electrocardiology 45. 6 (2012): 596-603.
    • (2012) Journal of Electrocardiology , vol.45 , Issue.6 , pp. 596-603
    • Li, Q.1    Clifford, G.D.2
  • 9
    • 84938081520 scopus 로고    scopus 로고
    • Multimodal heart beat detection using signal quality indices
    • Johnson, Alistair EW, et al. "Multimodal heart beat detection using signal quality indices. " Physiological measurement 36. 8 (2015): 1665.
    • (2015) Physiological Measurement , vol.36 , Issue.8 , pp. 1665
    • Johnson, A.E.W.1