메뉴 건너뛰기




Volumn 42, Issue , 2015, Pages 273-276

The PhysioNet/Computing in Cardiology Challenge 2015: Reducing false arrhythmia alarms in the ICU

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOLOGY; DISEASES; ERRORS; INTENSIVE CARE UNITS; NOISE POLLUTION; OPEN SYSTEMS; POLLUTION CONTROL; SIGNAL PROCESSING; SOFTWARE TESTING;

EID: 84964053945     PISSN: 23258861     EISSN: 2325887X     Source Type: Conference Proceeding    
DOI: 10.1109/CIC.2015.7408639     Document Type: Conference Paper
Times cited : (125)

References (14)
  • 1
  • 3
    • 0018709229 scopus 로고
    • A single scan algorithm for QRS-detection and feature extraction
    • Engelse WAH, Zeelenberg C. A single scan algorithm for QRS-detection and feature extraction. Comput in Cardiol 1979;6:37-42.
    • (1979) Comput in Cardiol , vol.6 , pp. 37-42
    • Engelse, W.A.H.1    Zeelenberg, C.2
  • 4
    • 4143054931 scopus 로고    scopus 로고
    • A robust open-source algorithm to detect onset and duration of QRS complexes
    • Zong W, Moody GB, Jiang D. A robust open-source algorithm to detect onset and duration of QRS complexes. Comput in Cardiol 2003;30:737-740.
    • (2003) Comput in Cardiol , vol.30 , pp. 737-740
    • Zong, W.1    Moody, G.B.2    Jiang, D.3
  • 6
    • 0020816086 scopus 로고
    • Delineation of the QRS Complex using the Envelope of the ECG
    • Nygårds ME, Sörnmo L. Delineation of the QRS Complex using the Envelope of the ECG. Med and Biol Engin and Comput 1983;21 (5):538-547.
    • (1983) Med and Biol Engin and Comput , vol.21 , Issue.5 , pp. 538-547
    • Nygårds, M.E.1    Sörnmo, L.2
  • 7
    • 84894144623 scopus 로고    scopus 로고
    • Open source Java-based ECG analysis software and android app for atrial fibrillation screening
    • Oster J, Behar J, Colloca R, Li Q, Li Q, Clifford GD. Open source Java-based ECG Analysis Software and Android App for Atrial Fibrillation Screening. In Comput in Cardiol. 2013; 731-734.
    • (2013) Comput in Cardiol. , pp. 731-734
    • Oster, J.1    Behar, J.2    Colloca, R.3    Li, Q.4    Li, Q.5    Clifford, G.D.6
  • 8
    • 84905186312 scopus 로고    scopus 로고
    • Combining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data
    • Behar J, Oster J, Clifford GD. Combining and Benchmarking Methods of Foetal ECG Extraction without Maternal or Scalp Electrode Data. Phys Measur 2014;35 (8):1569.
    • (2014) Phys Measur , vol.35 , Issue.8 , pp. 1569
    • Behar, J.1    Oster, J.2    Clifford, G.D.3
  • 9
    • 4143146627 scopus 로고    scopus 로고
    • An open-source algorithm to detect onset of arterial blood pressure pulses
    • Zong W, Heldt T, Moody G, Mark R. An open-source algorithm to detect onset of arterial blood pressure pulses. In Comput in Cardiol. 2003; 259-262.
    • (2003) Comput in Cardiol. , pp. 259-262
    • Zong, W.1    Heldt, T.2    Moody, G.3    Mark, R.4
  • 10
    • 38049078513 scopus 로고    scopus 로고
    • A signal abnormality index for arterial blood pressure waveforms
    • Sun J, Reisner A, Mark R. A Signal Abnormality Index for Arterial Blood Pressure Waveforms. In Comput in Cardiol. 2006; 13-16.
    • (2006) Comput in Cardiol. , pp. 13-16
    • Sun, J.1    Reisner, A.2    Mark, R.3
  • 11
    • 84866315935 scopus 로고    scopus 로고
    • Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
    • Li Q, Clifford GD. Dynamic time warping and machine learning for signal quality assessment of pulsatile signals. Phys Meas 2012;33 (9):1491-1501.
    • (2012) Phys Meas , vol.33 , Issue.9 , pp. 1491-1501
    • Li, Q.1    Clifford, G.D.2
  • 12
    • 84931432696 scopus 로고    scopus 로고
    • An open-source toolbox for analysing and processing physionet databases in matlab and octave
    • Silva I, Moody G. An open-source toolbox for analysing and processing physionet databases in matlab and octave. Journal of Open Research Software 2014;2 (1):e27.
    • (2014) Journal of Open Research Software , vol.2 , Issue.1 , pp. e27
    • Silva, I.1    Moody, G.2
  • 13
    • 84877912344 scopus 로고    scopus 로고
    • ECG Signal Quality during Arrhythmia and its Application to False Alarm Reduction
    • Behar J, Oster J, Li Q, Clifford GD. ECG Signal Quality during Arrhythmia and its Application to False Alarm Reduction. IEEE Trans on Biomed Engin 2013;60:1660-1666.
    • (2013) IEEE Trans on Biomed Engin , vol.60 , pp. 1660-1666
    • Behar, J.1    Oster, J.2    Li, Q.3    Clifford, G.D.4
  • 14
    • 84901253139 scopus 로고    scopus 로고
    • Ventricular fibrillation and tachycardia classification using a machine learning approach
    • Li Q, Rajagopalan C, Clifford G. Ventricular fibrillation and tachycardia classification using a machine learning approach. IEEE Transactions on Biomedical Engineering 2014;61 (6):1607-1613.
    • (2014) IEEE Transactions on Biomedical Engineering , vol.61 , Issue.6 , pp. 1607-1613
    • Li, Q.1    Rajagopalan, C.2    Clifford, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.