메뉴 건너뛰기




Volumn , Issue , 2002, Pages 261-264

Assessing biocompatibility of materials for implantable microelectrodes using cytotoxicity and protein adsorption studies

Author keywords

biocompatibility; cytotoxicity; Microelectrodes; protein adsorption

Indexed keywords

ADSORPTION; ATOMIC FORCE MICROSCOPY; BIOCOMPATIBILITY; CELL CULTURE; CYTOTOXICITY; ELECTRODES; IRIDIUM; MICROELECTRODES; PLATINUM; PROSTHETICS; PROTEINS; TIN OXIDES; TITANIUM OXIDES;

EID: 84964649215     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MMB.2002.1002326     Document Type: Conference Paper
Times cited : (38)

References (8)
  • 1
    • 0032479596 scopus 로고    scopus 로고
    • Implantable bioelectronic interfaces for lost nerve functions
    • P. Heiduschka and S. Thanos, "Implantable bioelectronic interfaces for lost nerve functions," Prog. Neurobiol., vol. 55, pp. 433-461, 1998.
    • (1998) Prog. Neurobiol. , vol.55 , pp. 433-461
    • Heiduschka, P.1    Thanos, S.2
  • 2
    • 0034105070 scopus 로고    scopus 로고
    • Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers
    • G. Ensell, D. J. Banks, P. R. Richards, W. Balachandran, and D. J. Ewins, "Silicon-based microelectrodes for neurophysiology, micromachined from silicon-on-insulator wafers," Med. Biol. Eng. Comput., vol. 38, pp. 175-179, 2000.
    • (2000) Med. Biol. Eng. Comput. , vol.38 , pp. 175-179
    • Ensell, G.1    Banks, D.J.2    Richards, P.R.3    Balachandran, W.4    Ewins, D.J.5
  • 4
    • 0022559394 scopus 로고
    • A peripheral nerve information transducer for amputees: Long-term multichannel recordings from rabbit peripheral nerves
    • D. J. Edell, "A peripheral nerve information transducer for amputees: long-term multichannel recordings from rabbit peripheral nerves," IEEE Trans. Biomed. Eng., vol. 33, pp. 203-214, 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , pp. 203-214
    • Edell, D.J.1
  • 5
    • 0025435155 scopus 로고
    • Strength characterisation of silicon microprobes in neurophysiological tissues
    • K. Najafi and J. F. Hetke, "Strength characterisation of silicon microprobes in neurophysiological tissues," IEEE Trans. Biomed. Eng., vol. 37, pp.474-481, 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 474-481
    • Najafi, K.1    Hetke, J.F.2
  • 6
    • 0026882265 scopus 로고
    • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
    • D. J. Edell, V. Van Toi, V. M. McNeil, and L. D. Clark, "Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex," IEEE Trans. Biomed. Eng., vol. 39, pp. 635-643, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 635-643
    • Edell, D.J.1    Van Toi, V.2    McNeil, V.M.3    Clark, L.D.4
  • 7
    • 0022367558 scopus 로고
    • Transparent indium-tin oxide electrode patterns for extracellular, multisite recordings in neuronal cultures
    • G. W. Gross, W. Y. Wen, and J. W. Lin, "Transparent indium-tin oxide electrode patterns for extracellular, multisite recordings in neuronal cultures," J. Neurosci. Meth., vol. 15, pp. 243-252, 1985.
    • (1985) J. Neurosci. Meth. , vol.15 , pp. 243-252
    • Gross, G.W.1    Wen, W.Y.2    Lin, J.W.3
  • 8
    • 0021990499 scopus 로고
    • Toxicity determined in vitro by morphological alterations and neutral red absorption
    • E. Borenfreund and J. A. Puerner, "Toxicity determined in vitro by morphological alterations and neutral red absorption," Toxicol. Let., vol. 24, pp.119-124, 1985.
    • (1985) Toxicol. Let. , vol.24 , pp. 119-124
    • Borenfreund, E.1    Puerner, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.