메뉴 건너뛰기




Volumn , Issue 5, 2014, Pages 806-815

Analysis of cross-sectional image filters for evaluating nonaveraged optical microangiography images

Author keywords

[No Author keywords available]

Indexed keywords

OPTICAL TOMOGRAPHY;

EID: 84964315888     PISSN: 1559128X     EISSN: 21553165     Source Type: Journal    
DOI: 10.1364/AO.53.000806     Document Type: Article
Times cited : (6)

References (33)
  • 1
    • 0033327503 scopus 로고    scopus 로고
    • Optical coherence tomography (OCT): A review
    • J. M. Schmitt, "Optical coherence tomography (OCT): a review," IEEE J. Sel. Top. Quantum Electron. 5, 1205-1215 (1999).
    • (1999) IEEE J. Sel. Top. Quantum Electron. , vol.5 , pp. 1205-1215
    • Schmitt, J.M.1
  • 2
    • 0242301675 scopus 로고    scopus 로고
    • Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    • J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, "Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography," Opt. Lett. 28, 2067-2069 (2003).
    • (2003) Opt. Lett. , vol.28 , pp. 2067-2069
    • De Boer, J.F.1    Cense, B.2    Park, B.H.3    Pierce, M.C.4    Tearney, G.J.5    Bouma, B.E.6
  • 3
    • 2942703878 scopus 로고    scopus 로고
    • Sensitivity advantage of swept source and fourier domain optical coherence tomography
    • M. Choma, M. Sarunic, C. Yang, and J. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography," Opt. Express 11, 2183-2189 (2003).
    • (2003) Opt. Express , vol.11 , pp. 2183-2189
    • Choma, M.1    Sarunic, M.2    Yang, C.3    Izatt, J.4
  • 5
    • 72449129943 scopus 로고    scopus 로고
    • Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique
    • J. Fingler, R. J. Zawadzki, J. S. Werner, D. Schwartz, and S. E. Fraser, "Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique," Opt. Express 17, 22190-22200 (2009).
    • (2009) Opt. Express , vol.17 , pp. 22190-22200
    • Fingler, J.1    Zawadzki, R.J.2    Werner, J.S.3    Schwartz, D.4    Fraser, S.E.5
  • 6
    • 77953152933 scopus 로고    scopus 로고
    • Doppler variance imaging for three-dimensional retina and choroid angiography
    • L. Yu and Z. Chen, "Doppler variance imaging for three-dimensional retina and choroid angiography," J. Biomed. Opt. 15, 016029 (2010).
    • (2010) J. Biomed. Opt. , vol.15 , pp. 016029
    • Yu, L.1    Chen, Z.2
  • 7
    • 0000926213 scopus 로고    scopus 로고
    • Doppler standard deviation imaging for clinical monitoring of in vivo human skin blood flow
    • Y Zhao, Z. Chen, C. Saxer, Q. Shen, S. Xiang, J. F. de Boer, and J. S. Nelson, "Doppler standard deviation imaging for clinical monitoring of in vivo human skin blood flow," Opt. Lett. 25, 1358-1360 (2000).
    • (2000) Opt. Lett. , vol.25 , pp. 1358-1360
    • Zhao, Y.1    Chen, Z.2    Saxer, C.3    Shen, Q.4    Xiang, S.5    De Boer, J.F.6    Nelson, J.S.7
  • 8
    • 78649279905 scopus 로고    scopus 로고
    • Autocorrelation optical coherence tomography for mapping transverse particle-flow velocity
    • Y Wang and R. Wang, "Autocorrelation optical coherence tomography for mapping transverse particle-flow velocity," Opt. Lett. 35, 3538-3540 (2010).
    • (2010) Opt. Lett. , vol.35 , pp. 3538-3540
    • Wang, Y.1    Wang, R.2
  • 9
    • 80052586689 scopus 로고    scopus 로고
    • In vivo imaging of the microcirculation of the volar forearm using correlation mapping optical coherence tomography (cmOCT)
    • J. Enfield, E. Jonathan, and M. Leahy, "In vivo imaging of the microcirculation of the volar forearm using correlation mapping optical coherence tomography (cmOCT)," Biomed. Opt. Express 2, 1184-1193 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1184-1193
    • Enfield, J.1    Jonathan, E.2    Leahy, M.3
  • 10
    • 79958186834 scopus 로고    scopus 로고
    • Correlation mapping method for generating microcirculation morphology from optical coherence tomography (OCT) intensity images
    • E. Jonathan, J. Enfield, and M. J. Leahy, "Correlation mapping method for generating microcirculation morphology from optical coherence tomography (OCT) intensity images," J. Biophotonics 4, 583-587 (2011).
    • (2011) J. Biophotonics , vol.4 , pp. 583-587
    • Jonathan, E.1    Enfield, J.2    Leahy, M.J.3
  • 12
    • 84867276637 scopus 로고    scopus 로고
    • A comparison of doppler optical coherence tomography methods
    • G. Liu, A. J. Lin, B. J. Tromberg, and Z. Chen, "A comparison of Doppler optical coherence tomography methods," Biomed. Opt. Express 3, 2669-2680 (2012).
    • (2012) Biomed. Opt. Express , vol.3 , pp. 2669-2680
    • Liu, G.1    Lin, A.J.2    Tromberg, B.J.3    Chen, Z.4
  • 15
    • 43049093773 scopus 로고    scopus 로고
    • Flow velocity estimation using joint spectral and time domain optical coherence tomography
    • M. Szkulmowski, A. Szkulmowska, T. Bajraszewski, A. Kowalczyk, and M. Wojtkowski, "Flow velocity estimation using joint spectral and time domain optical coherence tomography," Opt. Express 16, 6008-6025 (2008).
    • (2008) Opt. Express , vol.16 , pp. 6008-6025
    • Szkulmowski, M.1    Szkulmowska, A.2    Bajraszewski, T.3    Kowalczyk, A.4    Wojtkowski, M.5
  • 16
    • 68349158792 scopus 로고    scopus 로고
    • Flow velocity estimation by complex ambiguity free joint spectral and time domain optical coherence tomography
    • M. Szkulmowski, I. Grulkowski, D. Szlag, A. Szkulmowska, A. Kowalczyk, and M. Wojtkowski, "Flow velocity estimation by complex ambiguity free joint spectral and time domain optical coherence tomography," Opt. Express 17, 14281-14297 (2009).
    • (2009) Opt. Express , vol.17 , pp. 14281-14297
    • Szkulmowski, M.1    Grulkowski, I.2    Szlag, D.3    Szkulmowska, A.4    Kowalczyk, A.5    Wojtkowski, M.6
  • 17
    • 84864951150 scopus 로고    scopus 로고
    • Quantifying optical microangiography images obtained from a spectral domain optical coherence tomography system
    • R. Reif, J. Qin, L. An, Z. Zhi, S. Dziennis, and R. K Wang, "Quantifying optical microangiography images obtained from a spectral domain optical coherence tomography system," Int. J. Biomed. Imag. 2012, 509783 (2012).
    • (2012) Int. J. Biomed. Imag. , vol.2012 , pp. 509783
    • Reif, R.1    Qin, J.2    An, L.3    Zhi, Z.4    Dziennis, S.5    Wang, R.K.6
  • 18
    • 84855422667 scopus 로고    scopus 로고
    • In vivo microstructural and microvascular imaging of the human corneo-scleral limbus using optical coherence tomography
    • P. Li, L. An, R. Reif, T. T. Shen, M. Johnstone, and R. K. Wang, "In vivo microstructural and microvascular imaging of the human corneo-scleral limbus using optical coherence tomography," Biomed. Opt. Express 2, 3109-3118 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , pp. 3109-3118
    • Li, P.1    An, L.2    Reif, R.3    Shen, T.T.4    Johnstone, M.5    Wang, R.K.6
  • 19
    • 84863753268 scopus 로고    scopus 로고
    • High speed spectral domain optical coherence tomography for retinal imaging at 500, 000 A-lines per second
    • L. An, P. Li, T. T. Shen, and R. Wang, "High speed spectral domain optical coherence tomography for retinal imaging at 500, 000 A-lines per second," Biomed. Opt. Express 2, 2770-2783 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , pp. 2770-2783
    • An, L.1    Li, P.2    Shen, T.T.3    Wang, R.4
  • 20
    • 73349090287 scopus 로고    scopus 로고
    • Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo
    • Y Jia, N. Alkayed, and R. K Wang, "Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo," J. Biomed. Opt. 14, 040505 (2009).
    • (2009) J. Biomed. Opt. , vol.14 , pp. 040505
    • Jia, N.1    Alkayed, Y.2    Wang, R.K.3
  • 21
    • 80051732911 scopus 로고    scopus 로고
    • Highly sensitive imaging of renal microcirculation in vivo using ultrahigh sensitive optical microangiography
    • Z. Zhi, Y Jung, Y Jia, L. An, and R. K. Wang, "Highly sensitive imaging of renal microcirculation in vivo using ultrahigh sensitive optical microangiography," Biomed. Opt. Express 2, 1059-1068 (2011).
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1059-1068
    • Zhi, Z.1    Jung, Y.2    Jia, Y.3    An, L.4    Wang, R.K.5
  • 22
    • 79952382868 scopus 로고    scopus 로고
    • In vivo volumetric imaging of microcirculation within human skin under psoriatic conditions using optical microangiography
    • J. Qin, J. Jiang, L. An, D. Gareau, and R. K. Wang, "In vivo volumetric imaging of microcirculation within human skin under psoriatic conditions using optical microangiography," Lasers Surg. Med. 43, 122-129 (2011).
    • (2011) Lasers Surg. Med. , vol.43 , pp. 122-129
    • Qin, J.1    Jiang, J.2    An, L.3    Gareau, D.4    Wang, R.K.5
  • 23
    • 84863898685 scopus 로고    scopus 로고
    • Hemodynamic and morphological vasculature response to a burn monitored using a combined dual-wavelength laser speckle and optical microangiography imaging system
    • J. Qin, R. Reif, Z. Zhi, S. Dziennis, and R. Wang, "Hemodynamic and morphological vasculature response to a burn monitored using a combined dual-wavelength laser speckle and optical microangiography imaging system," Biomed. Opt. Express 3, 455-466 (2012).
    • (2012) Biomed. Opt. Express , vol.3 , pp. 455-466
    • Qin, J.1    Reif, R.2    Zhi, Z.3    Dziennis, S.4    Wang, R.5
  • 24
    • 84876572264 scopus 로고    scopus 로고
    • Effects of hypoxia on cochlear blood flow in mice using doppler optical microangiography
    • S. Dziennis, R. Reif, Z. Zhi, A. L. Nuttall, and R. K. Wang, "Effects of hypoxia on cochlear blood flow in mice using Doppler optical microangiography," J. Biomed. Opt. 17, 106003 (2012).
    • (2012) J. Biomed. Opt. , vol.17 , pp. 106003
    • Dziennis, S.1    Reif, R.2    Zhi, Z.3    Nuttall, A.L.4    Wang, R.K.5
  • 25
    • 84871280158 scopus 로고    scopus 로고
    • Monitoring hypoxia induced changes in cochlear blood flow and hemoglobin concentration using a combined dual-wavelength laser speckle contrast imaging and doppler optical microangiography system
    • R. Reif, J. Qin, L. Shi, S. Dziennis, Z. Zhi, A. L. Nuttall, and R. K. Wang, "Monitoring hypoxia induced changes in cochlear blood flow and hemoglobin concentration using a combined dual-wavelength laser speckle contrast imaging and Doppler optical microangiography system," PLoS One 7, e52041 (2012).
    • (2012) PLoS One , vol.7 , pp. e52041
    • Reif, R.1    Qin, J.2    Shi, L.3    Dziennis, S.4    Zhi, Z.5    Nuttall, A.L.6    Wang, R.K.7
  • 26
    • 84896915282 scopus 로고    scopus 로고
    • Super-resolution spectral estimation of optical micro-angiography for quantifying blood flow within microcirculatory tissue beds in vivo
    • S. Yousefi, J. Qin, and R. K. Wang, "Super-resolution spectral estimation of optical micro-angiography for quantifying blood flow within microcirculatory tissue beds in vivo," Biomed. Opt. Express 4, 1214-1228 (2013).
    • (2013) Biomed. Opt. Express , vol.4 , pp. 1214-1228
    • Yousefi, S.1    Qin, J.2    Wang, R.K.3
  • 27
    • 77950879651 scopus 로고    scopus 로고
    • Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds
    • L. An, J. Qin, and R. K. Wang, "Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds," Opt. Express 18, 8220-8228 (2010).
    • (2010) Opt. Express , vol.18 , pp. 8220-8228
    • An, L.1    Qin, J.2    Wang, R.K.3
  • 28
    • 84887055482 scopus 로고    scopus 로고
    • Label-free imaging of blood vessel morphology with capillary resolution using optical microangiography
    • R. Reif and R. K. Wang, "Label-free imaging of blood vessel morphology with capillary resolution using optical microangiography," Quant. Imaging Med. Surg. 2, 207-212 (2012).
    • (2012) Quant. Imaging Med. Surg. , vol.2 , pp. 207-212
    • Reif, R.1    Wang, R.K.2
  • 29
    • 66449137548 scopus 로고    scopus 로고
    • Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
    • R. K Wang and L. An, "Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo," Opt. Express 17, 8926-8940 (2009).
    • (2009) Opt. Express , vol.17 , pp. 8926-8940
    • Wang, R.K.1    An, L.2
  • 30
    • 34548359117 scopus 로고    scopus 로고
    • Speckle reduction in optical coherence tomography images using digital filtering
    • A. Ozcan, A. Bilenca, A. E. Desjardins, B. E. Bouma, and G. J. Tearney "Speckle reduction in optical coherence tomography images using digital filtering," J. Opt. Soc. Am. A 24, 1901-1910 (2007).
    • (2007) J. Opt. Soc. Am. A , vol.24 , pp. 1901-1910
    • Ozcan, A.1    Bilenca, A.2    Desjardins, A.E.3    Bouma, B.E.4    Tearney, G.J.5
  • 32
    • 84874558900 scopus 로고    scopus 로고
    • Tracking dynamic microvascular changes during healing after complete biopsy punch on the mouse pinna using optical microangiography
    • Y Jung, S. Dziennis, Z. Zhi, R. Reif, Y Zheng, and R. K. Wang, "Tracking dynamic microvascular changes during healing after complete biopsy punch on the mouse pinna using optical microangiography," PLoS One 8, e57976 (2013).
    • (2013) PLoS One , vol.8 , pp. e57976
    • Jung, Y.1    Dziennis, S.2    Zhi, Z.3    Reif, R.4    Zheng, Y.5    Wang, R.K.6
  • 33
    • 84897517256 scopus 로고    scopus 로고
    • Uniform enhancement of optical micro-angiography images using rayleigh contrast-limited adaptive histogram equalization
    • S. Yousefi, J. Qin, Z. Zhi, and R. K. Wang, "Uniform enhancement of optical micro-angiography images using Rayleigh contrast-limited adaptive histogram equalization," Quant. Imaging Med. Surg. 3, 5-17 (2013).
    • (2013) Quant. Imaging Med. Surg. , vol.3 , pp. 5-17
    • Yousefi, S.1    Qin, J.2    Zhi, Z.3    Wang, R.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.