메뉴 건너뛰기




Volumn 32, Issue 2, 2016, Pages 27-34

Challenges in calibration of the measurement of partial discharges at ultrahigh frequencies in power transformers

Author keywords

partial discharge measurement; Power transformer; Ultrahigh frequency partial discharge detection

Indexed keywords

DISCHARGE (FLUID MECHANICS); ELECTRIC SWITCHGEAR; POWER TRANSFORMERS;

EID: 84963812099     PISSN: 08837554     EISSN: None     Source Type: Journal    
DOI: 10.1109/MEI.2016.7414228     Document Type: Article
Times cited : (33)

References (13)
  • 1
    • 17644409075 scopus 로고    scopus 로고
    • Partial discharge monitoring for power transformers using UHF sensors part 1: Sensors and signal interpretation
    • M. D. Judd, Y. Li, and I. B. B. Hunter, "Partial discharge monitoring for power transformers using UHF sensors Part 1: Sensors and signal interpretation," IEEE Electr. Insul. Mag., vol. 21, no. 2, pp. 5-14, 2005.
    • (2005) IEEE Electr. Insul. Mag. , vol.21 , Issue.2 , pp. 5-14
    • Judd, M.D.1    Li, Y.2    Hunter, I.B.B.3
  • 2
    • 0032131431 scopus 로고    scopus 로고
    • A pulsed GTEM system for UHF sensor calibration
    • Aug.
    • M. D. Judd and O. Farish, "A pulsed GTEM system for UHF sensor calibration," IEEE Trans. Instrum. Meas., vol. 47, no. 4, pp. 875-880, Aug. 1998.
    • (1998) IEEE Trans. Instrum. Meas. , vol.47 , Issue.4 , pp. 875-880
    • Judd, M.D.1    Farish, O.2
  • 5
    • 84874240871 scopus 로고    scopus 로고
    • Investigating the partial discharge electromagnetic wave propagation in power transformers considering active part characteristics
    • Sep.
    • H. R. Mirzaei, A. Akbari, M. Zanjani, E. Gockenbach, and H. Borsi, "Investigating the partial discharge electromagnetic wave propagation in power transformers considering active part characteristics," in Proc. Int. Conf. Cond. Monit. Diag., Sep. 2012, pp. 442-445.
    • (2012) Proc. Int. Conf. Cond. Monit. Diag , pp. 442-445
    • Mirzaei, H.R.1    Akbari, A.2    Zanjani, M.3    Gockenbach, E.4    Borsi, H.5
  • 6
    • 0036760224 scopus 로고    scopus 로고
    • Transfer functionbased partial discharge localization in power transformers: A feasibility study
    • A. Akbari, P. Werle, H. Borsi, and E. Gockenbach, "Transfer functionbased partial discharge localization in power transformers: A feasibility study," IEEE Electr. Insul. Mag., vol. 18, no. 5, pp. 22-32, 2002.
    • (2002) IEEE Electr. Insul. Mag. , vol.18 , Issue.5 , pp. 22-32
    • Akbari, A.1    Werle, P.2    Borsi, H.3    Gockenbach, E.4
  • 7
    • 84923082633 scopus 로고    scopus 로고
    • Advancing new techniques for UHF PD detection and localization in the power transformers in the factory tests
    • H. R. Mirzaei, A. Akbari, E. Gockenbach, and K. Miralikhani, "Advancing new techniques for UHF PD detection and localization in the power transformers in the factory tests," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 1, pp. 448-455, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul. , vol.22 , Issue.1 , pp. 448-455
    • Mirzaei, H.R.1    Akbari, A.2    Gockenbach, E.3    Miralikhani, K.4
  • 8
    • 84865657378 scopus 로고    scopus 로고
    • Z. Chen, "EMC antenna fundamentals." Available: http://download.lenze.com/TD/Conformity%202004-108-EC-p500-v2294966-01-DE-EN-FR-ES-IT-PT.pdf.
    • EMC Antenna Fundamentals
    • Chen, Z.1
  • 9
    • 80052724797 scopus 로고    scopus 로고
    • Experience with UHF partial discharge detection and location in power transformers
    • Annapolis, MD
    • M. D. Judd, "Experience with UHF partial discharge detection and location in power transformers," presented at the Electr. Insul. Conf., Annapolis, MD, 2011.
    • (2011) Presented at the Electr. Insul. Conf.
    • Judd, M.D.1
  • 10
    • 85015762615 scopus 로고    scopus 로고
    • Suitability of ultra high frequency partial discharge measurement for quality assurance and testing of power transformers
    • Zurich, Switzerland
    • S. Tenbolen, M. Siegel, M. Beltle, and M. Reuter, "Suitability of ultra high frequency partial discharge measurement for quality assurance and testing of power transformers," presented at the Cigre SC A2 & C4 Joint Colloquium, Zurich, Switzerland, 2013.
    • (2013) Presented at the Cigre SC A2 & C4 Joint Colloquium
    • Tenbolen, S.1    Siegel, M.2    Beltle, M.3    Reuter, M.4
  • 11
    • 0003231417 scopus 로고    scopus 로고
    • Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method
    • CIGRE TF 15/33.03.05
    • CIGRE TF 15/33.03.05, "Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method," Electra, no. 183, pp. 74-87, 1999.
    • (1999) Electra , vol.183 , pp. 74-87
  • 12
    • 84873665661 scopus 로고    scopus 로고
    • A novel method for UHF partial discharge localization in power transformers using PSO algorithm
    • H. R. Mirzaei, A. Akbari, E. Gockenbach, M. Zanjani, and K. Miralikhani, "A novel method for UHF partial discharge localization in power transformers using PSO algorithm," IEEE Electr. Insul. Mag., vol. 29, no. 2, pp. 26-29, 2013.
    • (2013) IEEE Electr. Insul. Mag. , vol.29 , Issue.2 , pp. 26-29
    • Mirzaei, H.R.1    Akbari, A.2    Gockenbach, E.3    Zanjani, M.4    Miralikhani, K.5
  • 13
    • 23044481608 scopus 로고    scopus 로고
    • A compact antenna for ultrawide-band applications
    • Jul.
    • N. Behdad and K. Sarabandi, "A compact antenna for ultrawide-band applications," IEEE Trans. Antennas Propag., vol. 53, no. 7, pp. 2185-2192, Jul. 2005.
    • (2005) IEEE Trans. Antennas Propag. , vol.53 , Issue.7 , pp. 2185-2192
    • Behdad, N.1    Sarabandi, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.