메뉴 건너뛰기




Volumn 35, Issue 3, 2016, Pages 839-844

Ultrashort Microwave-Pumped Real-Time Thermoacoustic Breast Tumor Imaging System

Author keywords

breast tumor; Thermoacoustic imaging; ultrashort microwave; ultrasound

Indexed keywords

DIAGNOSIS; ELECTROMAGNETIC FIELDS; IMAGING SYSTEMS; MICROWAVE ACOUSTICS; MICROWAVES; PULSE GENERATORS; THERMOACOUSTICS; TRANSDUCERS; TUMORS; ULTRASONICS;

EID: 84963770314     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.2015.2497901     Document Type: Article
Times cited : (66)

References (33)
  • 1
    • 56449100677 scopus 로고    scopus 로고
    • Guideline implementation for breast healthcare in low-income and middle-income countries
    • B. O. Anderson, C. H. Yip, R. A. Smith, "Guideline implementation for breast healthcare in low-income and middle-income countries, " Cancer, vol. 113, pp. 2221-2243, 2008.
    • (2008) Cancer , vol.113 , pp. 2221-2243
    • Anderson, B.O.1    Yip, C.H.2    Smith, R.A.3
  • 2
    • 84903761758 scopus 로고    scopus 로고
    • Development and application of a suite of 4-D virtual breast phantoms for optimization and evaluation of breast imaging systems
    • Jul.
    • N. Kiarashi et al., "Development and application of a suite of 4-D virtual breast phantoms for optimization and evaluation of breast imaging systems, " IEEE Trans. Med. Imag., vol. 33, no. 7, pp. 1401-1409, Jul. 2014.
    • (2014) IEEE Trans. Med. Imag , vol.33 , Issue.7 , pp. 1401-1409
    • Kiarashi, N.1
  • 3
    • 84868550056 scopus 로고    scopus 로고
    • High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers
    • Y. Zhao et al., "High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers, " in Proc. Nat. Acad. Sci., 2012, vol. 109, pp. 18290-18294.
    • (2012) Proc. Nat. Acad. Sci. , vol.109 , pp. 18290-18294
    • Zhao, Y.1
  • 4
    • 70349671204 scopus 로고    scopus 로고
    • Design and characterization of a spatially distributed multibeam field emission X-ray source for stationary digital breast tomosynthesis
    • X. Qian, "Design and characterization of a spatially distributed multibeam field emission X-ray source for stationary digital breast tomosynthesis, " Med. Phys., vol. 36, pp. 4389-4399, 2009.
    • (2009) Med. Phys , vol.36 , pp. 4389-4399
    • Qian, X.1
  • 5
    • 24744461194 scopus 로고    scopus 로고
    • Coregistered tomographic X-ray and optical breast imaging: Initial results
    • Q. Zhang et al., "Coregistered tomographic X-ray and optical breast imaging: Initial results, " J. Biomed. Opt., vol. 10, pp. 024033-0240339, 2005.
    • (2005) J. Biomed. Opt , vol.10 , pp. 024033-0240339
    • Zhang, Q.1
  • 6
    • 0028359255 scopus 로고
    • The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
    • W. T. Joines, Y. Zhang, C. Li, R. Jirtle, "The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz, " Med. Phys., vol. 21, pp. 547-550, 1994.
    • (1994) Med. Phys , vol.21 , pp. 547-550
    • Joines, W.T.1    Zhang, Y.2    Li, C.3    Jirtle, R.4
  • 7
    • 0021673203 scopus 로고
    • Dielectric properties of normal and malignant human breast tissues at radiowave and microwave frequencies
    • S. S. Chaudhary, R. K. Mishra, A. Swarup, J. Thomas, "Dielectric properties of normal and malignant human breast tissues at radiowave and microwave frequencies, " Indian J. Biochem. Biophys., vol. 21, pp. 76-79, 1984.
    • (1984) Indian J. Biochem. Biophys , vol.21 , pp. 76-79
    • Chaudhary, S.S.1    Mishra, R.K.2    Swarup, A.3    Thomas, J.4
  • 8
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and biological materials: A critical review
    • K. R. Foster and H. P. Schwan, "Dielectric properties of tissues and biological materials: A critical review, " Crit. Rev. Biomed. Eng., vol. 17, pp. 25-104, 1989.
    • (1989) Crit. Rev. Biomed. Eng , vol.17 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 9
    • 0033024852 scopus 로고    scopus 로고
    • Potentialities of passive thermoacoustic tomography in hyperthermia
    • V. I. Passechnik, A. A. Anosov, M. G. Isrefilov, "Potentialities of passive thermoacoustic tomography in hyperthermia, " Int. J. Hyperthermia., vol. 15, pp. 123-144, 1999.
    • (1999) Int. J. Hyperthermia., Vol. , Issue.15 , pp. 123-144
    • Passechnik, V.I.1    Anosov, A.A.2    Isrefilov, M.G.3
  • 10
    • 0034129105 scopus 로고    scopus 로고
    • Scanning thermoacoustic tomography in biological tissue
    • G. Ku and L. V. Wang, "Scanning thermoacoustic tomography in biological tissue, " Med. Phys., vol. 27, pp. 1195-1202, 2000.
    • (2000) Med. Phys , vol.27 , pp. 1195-1202
    • Ku, G.1    Wang, L.V.2
  • 11
    • 84868540408 scopus 로고    scopus 로고
    • Three-Dimensional thermoacoustic imaging for early breast cancer detection
    • Z. Ji, C. Lou, S. Yang, D. Xing, "Three-dimensional thermoacoustic imaging for early breast cancer detection, " Med. Phys., vol. 39, pp. 6738-6744, 2012.
    • (2012) Med. Phys , vol.39 , pp. 6738-6744
    • Ji, Z.1    Lou, C.2    Yang, S.3    Xing, D.4
  • 13
    • 84918828748 scopus 로고    scopus 로고
    • Iterative reconstruction method with optimal time-of-flights for imaging microwave absorption properties of tissues in acoustically heterogeneous environment in microwave-induced thermoacoustic tomography (MITAT)
    • J. Wang, Z. Zhao, J. Song, Z. Nie, "Iterative reconstruction method with optimal time-of-flights for imaging microwave absorption properties of tissues in acoustically heterogeneous environment in microwave-induced thermoacoustic tomography (MITAT), " J. Electromagn. Waves Appl., vol. 28, pp. 2350-2363, 2014.
    • (2014) J. Electromagn. Waves Appl , vol.28 , pp. 2350-2363
    • Wang, J.1    Zhao, Z.2    Song, J.3    Nie, Z.4
  • 14
    • 84902438626 scopus 로고    scopus 로고
    • Stepped-frequency continuous-wave microwave-induced thermoacoustic imaging
    • H. Nan and A. Arbabian, "Stepped-frequency continuous-wave microwave-induced thermoacoustic imaging, " Appl. Phys. Lett., vol. 104, p. 224104, 2014.
    • (2014) Appl. Phys. Lett , vol.104 , pp. 224104
    • Nan, H.1    Arbabian, A.2
  • 15
    • 84874246804 scopus 로고    scopus 로고
    • Thermoacoustic resonance effect and circuit modeling of biological tissue
    • F. Gao, Y. Zheng, X. Feng, C. D. Ohl, "Thermoacoustic resonance effect and circuit modeling of biological tissue, " Appl. Phys. Lett., vol. 102, p. 063702, 2013.
    • (2013) Appl. Phys. Lett , vol.102 , pp. 063702
    • Gao, F.1    Zheng, Y.2    Feng, X.3    Ohl, C.D.4
  • 16
    • 77956303154 scopus 로고    scopus 로고
    • Near-field radiofrequency thermoacoustic tomography with impulse excitation
    • D. Razansky, S. Kellnberger, V. Ntziachristos, "Near-field radiofrequency thermoacoustic tomography with impulse excitation, " Med. Phys., vol. 37, pp. 4602-4607, 2010.
    • (2010) Med. Phys , vol.37 , pp. 4602-4607
    • Razansky, D.1    Kellnberger, S.2    Ntziachristos, V.3
  • 17
    • 79960743244 scopus 로고    scopus 로고
    • Ex vivo thermoacoustic imaging over large fields of view with 108 MHz irradiation
    • Aug.
    • A. T. Eckhart, R. T. Balmer, W. A. See, S. K. Patch, "Ex vivo thermoacoustic imaging over large fields of view with 108 MHz irradiation, " IEEE Trans. Biomed. Eng., vol. 58, no. 8, pp. 2238-2246, Aug. 2011.
    • (2011) IEEE Trans. Biomed. Eng , vol.58 , Issue.8 , pp. 2238-2246
    • Eckhart, A.T.1    Balmer, R.T.2    See, W.A.3    Patch, S.K.4
  • 18
    • 0042819899 scopus 로고    scopus 로고
    • Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries
    • Sep.
    • M. Xu, Y. Xu, L. V. Wang, "Time-domain reconstruction algorithms and numerical simulations for thermoacoustic tomography in various geometries, " IEEE Trans. Biomed. Eng., vol. 50, no. 9, pp. 1086-1099, Sep. 2003.
    • (2003) IEEE Trans. Biomed. Eng , vol.50 , Issue.9 , pp. 1086-1099
    • Xu, M.1    Xu, Y.2    Wang, L.V.3
  • 19
    • 84871274845 scopus 로고    scopus 로고
    • Quantitative thermoacoustic tomography: Recovery of conductivity maps of heterogeneous media
    • L. Huang, L. Yao, L. Liu, J. Rong, H. Jiang, "Quantitative thermoacoustic tomography: Recovery of conductivity maps of heterogeneous media, " Appl. Phys. Lett., vol. 101, p. 244106, 2012.
    • (2012) Appl. Phys. Lett , vol.101 , pp. 244106
    • Huang, L.1    Yao, L.2    Liu, L.3    Rong, J.4    Jiang, H.5
  • 20
    • 33846594267 scopus 로고    scopus 로고
    • Three-dimensional finite-element-based photoacoustic tomography: Reconstruction algorithm and simulations
    • Z. Yuan and H. B. Jiang, "Three-dimensional finite-element-based photoacoustic tomography: Reconstruction algorithm and simulations, " Med. Phys., vol. 34, pp. 538-546, 2007.
    • (2007) Med. Phys , vol.34 , pp. 538-546
    • Yuan, Z.1    Jiang, H.B.2
  • 21
    • 34248529702 scopus 로고    scopus 로고
    • Detection of foreign body using fast thermoacoustic tomography with a multielement linear transducer array
    • L. Nie, D. Xing, D. Yang, L. Zeng, Q. Zhou, "Detection of foreign body using fast thermoacoustic tomography with a multielement linear transducer array, " Appl. Phys. Lett., vol. 90, p. 174109, 2007.
    • (2007) Appl. Phys. Lett , vol.90 , pp. 174109
    • Nie, L.1    Xing, D.2    Yang, D.3    Zeng, L.4    Zhou, Q.5
  • 22
    • 68149181733 scopus 로고    scopus 로고
    • In vivo detection and imaging of lowdensity foreign body with microwave-induced thermoacoustic tomography
    • L. Nie, D. Xing, S. Yang, "In vivo detection and imaging of lowdensity foreign body with microwave-induced thermoacoustic tomography, " Med. Phys., vol. 36, pp. 3429-3437, 2009.
    • (2009) Med. Phys , vol.36 , pp. 3429-3437
    • Nie, L.1    Xing, D.2    Yang, S.3
  • 23
    • 84870170312 scopus 로고    scopus 로고
    • Ultrashort microwaveinduced thermoacoustic imaging: A breakthrough in excitation efficiency and spatial resolution
    • C. Lou, S. Yang, Z. Ji, Q. Chen, D. Xing, "Ultrashort microwaveinduced thermoacoustic imaging: A breakthrough in excitation efficiency and spatial resolution, " Phys. Rev. Lett., vol. 109, p. 218101, 2012.
    • (2012) Phys. Rev. Lett , vol.109 , pp. 218101
    • Lou, C.1    Yang, S.2    Ji, Z.3    Chen, Q.4    Xing, D.5
  • 24
    • 84908190402 scopus 로고    scopus 로고
    • Thermoacoustic imaging over large field of view for three-dimensional breast tumor localization: A phantom study
    • Y. Fu, Z. Ji, W. Ding, F. Ye, C. Lou, "Thermoacoustic imaging over large field of view for three-dimensional breast tumor localization: A phantom study, " Med. Phys., vol. 41, p. 110701, 2014.
    • (2014) Med. Phys , vol.41 , pp. 110701
    • Fu, Y.1    Ji, Z.2    Ding, W.3    Ye, F.4    Lou, C.5
  • 25
    • 84940705649 scopus 로고    scopus 로고
    • Shape-adapting thermoacoustic imaging system based on flexible multi-element transducer
    • Z. Ji, W. Ding, F. Ye, C. Lou, D. Xing, "Shape-adapting thermoacoustic imaging system based on flexible multi-element transducer, " Appl. Phys. Lett., vol. 107, p. 094104, 2015.
    • (2015) Appl. Phys. Lett , vol.107 , pp. 094104
    • Ji, Z.1    Ding, W.2    Ye, F.3    Lou, C.4    Xing, D.5
  • 26
    • 84945370639 scopus 로고    scopus 로고
    • Near-field microwave distribution measurement with a point detector base on thermoacoustic effect
    • W. Ding, Z. Ji, F. Ye, C. Lou, D. Xing, "Near-field microwave distribution measurement with a point detector base on thermoacoustic effect, " IEEE Trans. Microw. Theory Techn., vol. 99, pp. 1-5, 2015.
    • (2015) IEEE Trans. Microw. Theory Techn , vol.99 , pp. 1-5
    • Ding, W.1    Ji, Z.2    Ye, F.3    Lou, C.4    Xing, D.5
  • 27
    • 36049041394 scopus 로고    scopus 로고
    • A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries
    • M. Lazebnik et al., "A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries, " Phys. Med. Biol., vol. 52, pp. 6093-6115, 2007.
    • (2007) Phys. Med. Biol , vol.52 , pp. 6093-6115
    • Lazebnik, M.1
  • 28
    • 72649088986 scopus 로고    scopus 로고
    • Comparison of planar and circular antenna configurations for breast cancer detection using microwave imaging
    • R. C. Conceicao, M. O. Halloran, M. Glavin, E. Jones, "Comparison of planar and circular antenna configurations for breast cancer detection using microwave imaging, " Progr. Electromagn. Res., vol. 99, pp. 1-20, 2009.
    • (2009) Progr. Electromagn. Res , vol.99 , pp. 1-20
    • Conceicao, R.C.1    Halloran, M.O.2    Glavin, M.3    Jones, E.4
  • 29
    • 84875302178 scopus 로고    scopus 로고
    • Beamspace time-reversal microwave imaging for breast cancer detection
    • M. D. Hossain, A. S. Mohan, M. J. Abedin, "Beamspace time-reversal microwave imaging for breast cancer detection, " IEEE Antennas Wireless Propagat. Lett., vol. 12, pp. 241-244, 2013.
    • (2013) IEEE Antennas Wireless Propagat. Lett , vol.12 , pp. 241-244
    • Hossain, M.D.1    Mohan, A.S.2    Abedin, M.J.3
  • 30
    • 85027957695 scopus 로고    scopus 로고
    • Computational feasibility study of contrast-enhanced thermoacoustic imaging for breast cancer detection using realistic numerical breast phantoms
    • May
    • X. Wang, T. Qin, R. S. Witte, H. Xin, "Computational feasibility study of contrast-enhanced thermoacoustic imaging for breast cancer detection using realistic numerical breast phantoms, " IEEE Trans. Microw. Theory Tech., vol. 63, no. 5, pp. 1489-1501, May 2015.
    • (2015) IEEE Trans. Microw. Theory Tech , vol.63 , Issue.5 , pp. 1489-1501
    • Wang, X.1    Qin, T.2    Witte, R.S.3    Xin, H.4
  • 31
    • 79960743244 scopus 로고    scopus 로고
    • Ex vivo thermoacoustic imaging over large fields of view with 108 MHz irradiation
    • Aug.
    • A. T. Eckhart, R. T. Balmer, W. A. See, S. K. Patch, "Ex vivo thermoacoustic imaging over large fields of view with 108 MHz irradiation, " IEEE Trans. Biomed. Eng., vol. 58, no. 8, pp. 2238-2246, Aug. 2011.
    • (2011) IEEE Trans. Biomed. Eng , vol.58 , Issue.8 , pp. 2238-2246
    • Eckhart, A.T.1    Balmer, R.T.2    See, W.A.3    Patch, S.K.4
  • 32
    • 84945383085 scopus 로고    scopus 로고
    • A microwave detection way by electromagnetic and elastic resonance: Breaking the bottleneck of spatial resolution in microwave imaging
    • Z. Ji et al., "A microwave detection way by electromagnetic and elastic resonance: Breaking the bottleneck of spatial resolution in microwave imaging, " Appl. Phys. Lett., vol. 107, p. 164103, 2015.
    • (2015) Appl. Phys. Lett , vol.107 , pp. 164103
    • Ji, Z.1
  • 33
    • 84863082580 scopus 로고    scopus 로고
    • Microwave-induced thermoacoustic computed tomography with a clinical contrast agent of NMG2 [Gd (DTPA)]
    • H. Qin, S. Yang, D. Xing, "Microwave-induced thermoacoustic computed tomography with a clinical contrast agent of NMG2 [Gd (DTPA)], " Appl. Phys. Lett., vol. 100, p. 033701, 2012.
    • (2012) Appl. Phys. Lett , vol.100 , pp. 033701
    • Qin, H.1    Yang, S.2    Xing, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.