메뉴 건너뛰기




Volumn 134, Issue 4, 2016, Pages 367-373

Automated quantification of capillary nonperfusion using optical coherence tomography angiography in diabetic retinopathy

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; AUTOMATION; CAPILLARY DENSITY; CAPILLARY NONPERFUSION; CLINICAL ARTICLE; CLINICAL PRACTICE; CONTROLLED STUDY; DIABETIC RETINOPATHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FALSE POSITIVE RESULT; FEMALE; FLUORESCENCE ANGIOGRAPHY; FOLLOW UP; FOVEAL AVASCULAR ZONE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MACULAR ISCHEMIA; MALE; MEASUREMENT REPEATABILITY; OBSERVATIONAL STUDY; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL COHERENCE TOMOGRAPHY DEVICE; OPTICAL COHERENCETOMOGRAPHIC ANGIOGRAPHY; PARAFOVEAL VESSEL DENSITY; PERIFOVEAL VESSEL DENSITY; PILOT STUDY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RETINA DISEASE; SENSITIVITY AND SPECIFICITY; TERTIARY CARE CENTER; TOTAL AVASCULAR AREA; VISION; VISUAL ACUITY; VISUAL SYSTEM PARAMETERS; AGED; ALGORITHM; CASE CONTROL STUDY; DIAGNOSTIC IMAGING; ISCHEMIA; MACULAR DEGENERATION; MIDDLE AGED; PATHOPHYSIOLOGY; PROCEDURES; RADIOGRAPHY; RETINA BLOOD VESSEL; SEVERITY OF ILLNESS INDEX; STATISTICS AND NUMERICAL DATA;

EID: 84963507420     PISSN: 21686165     EISSN: None     Source Type: Journal    
DOI: 10.1001/jamaophthalmol.2015.5658     Document Type: Article
Times cited : (334)

References (33)
  • 1
    • 0025808946 scopus 로고
    • Fluorescein angiographic risk factors for progression of diabetic retinopathy: ETDRS report number 13
    • Early Treatment Diabetic Retinopathy Study Research Group. Fluorescein angiographic risk factors for progression of diabetic retinopathy: ETDRS report number 13. Ophthalmology. 1991;98 (5)(suppl):834-840.
    • (1991) Ophthalmology. , vol.98 , Issue.5 , pp. 834-840
  • 2
    • 33847130442 scopus 로고    scopus 로고
    • Relationship between optical coherence tomography-measured central retinal thickness and visual acuity in diabetic macular edema
    • Browning DJ, Glassman AR, Aiello LP, et al; Diabetic Retinopathy Clinical Research Network. Relationship between optical coherence tomography-measured central retinal thickness and visual acuity in diabetic macular edema. Ophthalmology. 2007;114(3):525-536.
    • (2007) Ophthalmology. , vol.114 , Issue.3 , pp. 525-536
    • Browning, D.J.1    Glassman, A.R.2    Aiello, L.P.3
  • 3
    • 84896727882 scopus 로고    scopus 로고
    • Quantitative analysis of diabetic macular ischemia using optical coherence tomography
    • Sim DA, Keane PA, Fung S, et al. Quantitative analysis of diabetic macular ischemia using optical coherence tomography. Invest Ophthalmol Vis Sci. 2014;55(1):417-423.
    • (2014) Invest Ophthalmol Vis Sci. , vol.55 , Issue.1 , pp. 417-423
    • Sim, D.A.1    Keane, P.A.2    Fung, S.3
  • 4
    • 33746321576 scopus 로고    scopus 로고
    • Relationship between macular microcirculation and progression of diabetic macular edema
    • Sakata K, Funatsu H, Harino S, Noma H, Hori S. Relationship between macular microcirculation and progression of diabetic macular edema. Ophthalmology. 2006;113(8):1385-1391.
    • (2006) Ophthalmology. , vol.113 , Issue.8 , pp. 1385-1391
    • Sakata, K.1    Funatsu, H.2    Harino, S.3    Noma, H.4    Hori, S.5
  • 5
    • 35548954701 scopus 로고    scopus 로고
    • Relationship of macular microcirculation and retinal thickness with visual acuity in diabetic macular edema
    • Sakata K, Funatsu H, Harino S, Noma H, Hori S. Relationship of macular microcirculation and retinal thickness with visual acuity in diabetic macular edema. Ophthalmology. 2007;114(11):2061-2069.
    • (2007) Ophthalmology. , vol.114 , Issue.11 , pp. 2061-2069
    • Sakata, K.1    Funatsu, H.2    Harino, S.3    Noma, H.4    Hori, S.5
  • 6
    • 0025886899 scopus 로고
    • Retinal microcirculation in patients with diabetes mellitus: Dynamic and morphological analysis of perifoveal capillary network
    • Arend O, Wolf S, Jung F, et al. Retinal microcirculation in patients with diabetes mellitus: dynamic and morphological analysis of perifoveal capillary network. Br J Ophthalmol. 1991;75(9): 514-518.
    • (1991) Br J Ophthalmol. , vol.75 , Issue.9 , pp. 514-518
    • Arend, O.1    Wolf, S.2    Jung, F.3
  • 8
    • 0025808944 scopus 로고
    • Classification of diabetic retinopathy from fluorescein angiograms: ETDRS report number 11
    • Early Treatment Diabetic Retinopathy Study Research Group. Classification of diabetic retinopathy from fluorescein angiograms: ETDRS report number 11. Ophthalmology. 1991;98(5) (suppl):807-822.
    • (1991) Ophthalmology. , vol.98 , Issue.5 , pp. 807-822
  • 9
    • 16844384965 scopus 로고    scopus 로고
    • Foveal avascular zone in diabetic retinopathy: Quantitative vs qualitative assessment
    • Conrath J, Giorgi R, Raccah D, Ridings B. Foveal avascular zone in diabetic retinopathy: quantitative vs qualitative assessment. Eye (Lond). 2005;19(3): 322-326.
    • (2005) Eye (Lond). , vol.19 , Issue.3 , pp. 322-326
    • Conrath, J.1    Giorgi, R.2    Raccah, D.3    Ridings, B.4
  • 10
    • 84930752756 scopus 로고    scopus 로고
    • Optical coherence tomography angiography in diabetic retinopathy: A prospective pilot study
    • Ishibazawa A, Nagaoka T, Takahashi A, et al. Optical coherence tomography angiography in diabetic retinopathy: a prospective pilot study. Am J Ophthalmol. 2015;160(1):35-44.e1.
    • (2015) Am J Ophthalmol. , vol.160 , Issue.1 , pp. 35-35e1
    • Ishibazawa, A.1    Nagaoka, T.2    Takahashi, A.3
  • 11
    • 84922657937 scopus 로고    scopus 로고
    • Three-dimensional vascular imaging of proliferative diabetic retinopathy by Doppler optical coherence tomography
    • Miura M, Hong YJ, Yasuno Y, Muramatsu D, Iwasaki T, Goto H. Three-dimensional vascular imaging of proliferative diabetic retinopathy by Doppler optical coherence tomography. Am J Ophthalmol. 2015;159(3):528-38.e3.
    • (2015) Am J Ophthalmol. , vol.159 , Issue.3 , pp. 528-528e3
    • Miura, M.1    Hong, Y.J.2    Yasuno, Y.3    Muramatsu, D.4    Iwasaki, T.5    Goto, H.6
  • 12
    • 84928891618 scopus 로고    scopus 로고
    • Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye
    • Jia Y, Bailey ST, Hwang TS, et al. Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye. Proc Natl Acad Sci USA. 2015;112(18):E2395-E2402.
    • (2015) Proc Natl Acad Sci USA. , vol.112 , Issue.18 , pp. E2395-E2402
    • Jia, Y.1    Bailey, S.T.2    Hwang, T.S.3
  • 13
    • 84891627112 scopus 로고    scopus 로고
    • Phase-variance optical coherence tomography: A technique for noninvasive angiography
    • Schwartz DM, Fingler J, Kim DY, et al. Phase-variance optical coherence tomography: a technique for noninvasive angiography. Ophthalmology. 2014;121(1):180-187.
    • (2014) Ophthalmology. , vol.121 , Issue.1 , pp. 180-187
    • Schwartz, D.M.1    Fingler, J.2    Kim, D.Y.3
  • 14
    • 84888610885 scopus 로고    scopus 로고
    • World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects
    • World Medical Association. World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. JAMA. 2013;310(20):2191-2194.
    • (2013) JAMA. , vol.310 , Issue.20 , pp. 2191-2194
  • 15
    • 0042932653 scopus 로고    scopus 로고
    • Proposed international clinical diabetic retinopathy and diabetic macular edema disease severity scales
    • Wilkinson CP, Ferris FL III, Klein RE, et al; Global Diabetic Retinopathy Project Group. Proposed international clinical diabetic retinopathy and diabetic macular edema disease severity scales. Ophthalmology. 2003;110(9):1677-1682.
    • (2003) Ophthalmology. , vol.110 , Issue.9 , pp. 1677-1682
    • Wilkinson, C.P.1    Ferris, F.L.2    Klein, R.E.3
  • 16
    • 84863179386 scopus 로고    scopus 로고
    • Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
    • Jia Y, Tan O, Tokayer J, et al. Split-spectrum amplitude-decorrelation angiography with optical coherence tomography. Opt Express. 2012;20(4): 4710-4725.
    • (2012) Opt Express. , vol.20 , Issue.4 , pp. 4710-4725
    • Jia, Y.1    Tan, O.2    Tokayer, J.3
  • 17
    • 84903821646 scopus 로고    scopus 로고
    • Quantitative optical coherence tomography angiography of choroidal neovascularization in age-related macular degeneration
    • Jia Y, Bailey ST, Wilson DJ, et al. Quantitative optical coherence tomography angiography of choroidal neovascularization in age-related macular degeneration. Ophthalmology. 2014;121(7): 1435-1444.
    • (2014) Ophthalmology. , vol.121 , Issue.7 , pp. 1435-1444
    • Jia, Y.1    Bailey, S.T.2    Wilson, D.J.3
  • 18
    • 84903814394 scopus 로고    scopus 로고
    • Optical coherence tomography angiography of optic disc perfusion in glaucoma
    • Jia Y, Wei E, Wang X, et al. Optical coherence tomography angiography of optic disc perfusion in glaucoma. Ophthalmology. 2014;121(7):1322-1332.
    • (2014) Ophthalmology. , vol.121 , Issue.7 , pp. 1322-1332
    • Jia, Y.1    Wei, E.2    Wang, X.3
  • 19
    • 84981332536 scopus 로고    scopus 로고
    • Optimization of the split-spectrum amplitude-decorrelation angiography algorithm on a spectral optical coherence tomography system
    • Gao SS, Liu G, Huang D, Jia Y. Optimization of the split-spectrum amplitude-decorrelation angiography algorithm on a spectral optical coherence tomography system. Opt Lett. 2015;40 (10):2305-2308.
    • (2015) Opt Lett. , vol.40 , Issue.10 , pp. 2305-2308
    • Gao, S.S.1    Liu, G.2    Huang, D.3    Jia, Y.4
  • 20
    • 84904681428 scopus 로고    scopus 로고
    • Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization
    • Kraus MF, Liu JJ, Schottenhamml J, et al. Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization. Biomed Opt Express. 2014;5(8):2591-2613.
    • (2014) Biomed Opt Express. , vol.5 , Issue.8 , pp. 2591-2613
    • Kraus, M.F.1    Liu, J.J.2    Schottenhamml, J.3
  • 21
    • 84867372679 scopus 로고    scopus 로고
    • Does optic nerve head size variation affect circumpapillary retinal nerve fiber layer thickness measurement by optical coherence tomography?
    • Huang D, Chopra V, Lu AT, Tan O, Francis B, Varma R; Advanced Imaging for Glaucoma Study-AIGS Group. Does optic nerve head size variation affect circumpapillary retinal nerve fiber layer thickness measurement by optical coherence tomography? Invest Ophthalmol Vis Sci. 2012;53(8): 4990-4997.
    • (2012) Invest Ophthalmol Vis Sci. , vol.53 , Issue.8 , pp. 4990-4997
    • Huang, D.1    Chopra, V.2    Lu, A.T.3    Tan, O.4    Francis, B.5    Varma, R.6
  • 22
    • 0027457620 scopus 로고
    • Receiver-operating characteristic (ROC) plots: A fundamental evaluation tool in clinical medicine
    • Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clin Chem. 1993;39(4):561-577.
    • (1993) Clin Chem. , vol.39 , Issue.4 , pp. 561-577
    • Zweig, M.H.1    Campbell, G.2
  • 23
    • 84921518376 scopus 로고    scopus 로고
    • Long-term effects of therapy with ranibizumab on diabetic retinopathy severity and baseline risk factors for worsening retinopathy
    • Ip MS, Domalpally A, Sun JK, Ehrlich JS. Long-term effects of therapy with ranibizumab on diabetic retinopathy severity and baseline risk factors for worsening retinopathy. Ophthalmology. 2015;122(2):367-374.
    • (2015) Ophthalmology. , vol.122 , Issue.2 , pp. 367-374
    • Ip, M.S.1    Domalpally, A.2    Sun, J.K.3    Ehrlich, J.S.4
  • 24
    • 84906796586 scopus 로고    scopus 로고
    • Fluorescein angiography: Basic principles and interpretation
    • Sadda SR, ed New York, NY: Elsevier
    • Johnson RN, Fu AD, McDonald R, et al. Fluorescein angiography: basic principles and interpretation. In: Sadda SR, ed. Retina. Vol 1. New York, NY: Elsevier; 2013:2-50.
    • (2013) Retina. , vol.1 , pp. 2-50
    • Johnson, R.N.1    Fu, A.D.2    McDonald, R.3
  • 25
    • 0028331302 scopus 로고
    • Perifoveal microcirculation with non-insulin-dependent diabetes mellitus
    • Arend O, Wolf S, Remky A, et al. Perifoveal microcirculation with non-insulin-dependent diabetes mellitus. Graefes Arch Clin Exp Ophthalmol. 1994;232(4):225-231.
    • (1994) Graefes Arch Clin Exp Ophthalmol. , vol.232 , Issue.4 , pp. 225-231
    • Arend, O.1    Wolf, S.2    Remky, A.3
  • 28
    • 0016205942 scopus 로고
    • On the retinal vasculature of the human fovea
    • Bird AC, Weale RA. On the retinal vasculature of the human fovea. Exp Eye Res. 1974;19(5):409-417.
    • (1974) Exp Eye Res. , vol.19 , Issue.5 , pp. 409-417
    • Bird, A.C.1    Weale, R.A.2
  • 29
    • 79952603807 scopus 로고    scopus 로고
    • Imaging retinal capillaries using ultrahigh-resolution optical coherence tomography and adaptive optics
    • Wang Q, Kocaoglu OP, Cense B, et al. Imaging retinal capillaries using ultrahigh-resolution optical coherence tomography and adaptive optics. Invest Ophthalmol Vis Sci. 2011;52(9):6292-6299.
    • (2011) Invest Ophthalmol Vis Sci. , vol.52 , Issue.9 , pp. 6292-6299
    • Wang, Q.1    Kocaoglu, O.P.2    Cense, B.3
  • 30
    • 0028293306 scopus 로고
    • Quantification of retinal capillary density and flow velocity in patients with essential hypertension
    • Wolf S, Arend O, Schulte K, Ittel TH, Reim M. Quantification of retinal capillary density and flow velocity in patients with essential hypertension. Hypertension. 1994;23(4):464-467.
    • (1994) Hypertension. , vol.23 , Issue.4 , pp. 464-467
    • Wolf, S.1    Arend, O.2    Schulte, K.3    Ittel, T.H.4    Reim, M.5
  • 31
    • 84908583879 scopus 로고    scopus 로고
    • Simultaneous estimation of bidirectional particle flow and relative flux using MUSIC-OCT: Phantom studies
    • Yousefi S, Wang RK. Simultaneous estimation of bidirectional particle flow and relative flux using MUSIC-OCT: phantom studies. Phys Med Biol. 2014; 59(22):6693-6708.
    • (2014) Phys Med Biol. , vol.59 , Issue.22 , pp. 6693-6708
    • Yousefi, S.1    Wang, R.K.2
  • 32
    • 84857962348 scopus 로고    scopus 로고
    • Noninvasive imaging of the foveal avascular zone with high-speed, phase-variance optical coherence tomography
    • Kim DY, Fingler J, Zawadzki RJ, et al. Noninvasive imaging of the foveal avascular zone with high-speed, phase-variance optical coherence tomography. Invest Ophthalmol Vis Sci. 2012;53(1): 85-92.
    • (2012) Invest Ophthalmol Vis Sci. , vol.53 , Issue.1 , pp. 85-92
    • Kim, D.Y.1    Fingler, J.2    Zawadzki, R.J.3
  • 33
    • 0028001627 scopus 로고
    • Absence of foveal avascular zone demonstrated by laser scanning fluorescein angiography
    • Sander B, Larsen M, Engler C, Lund-Andersen H. Absence of foveal avascular zone demonstrated by laser scanning fluorescein angiography. Acta Ophthalmol (Copenh). 1994;72(5):550-552.
    • (1994) Acta Ophthalmol (Copenh). , vol.72 , Issue.5 , pp. 550-552
    • Sander, B.1    Larsen, M.2    Engler, C.3    Lund-Andersen, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.