메뉴 건너뛰기




Volumn 11, Issue 11, 2016, Pages e1314-e1320

Real-world multicentre experience with the Direct Flow medical® repositionable and retrievable transcatheter aortic valve implantation system for the treatment of high-risk patients with severe aortic stenosis

Author keywords

Repositionability; Retrievability; Severe aortic stenosis; Transcatheter aortic valve implantation

Indexed keywords

ACUTE KIDNEY FAILURE; AGED; AORTA STENOSIS; ARTICLE; ATRIOVENTRICULAR BLOCK; BELGIUM; CARDIOVASCULAR DISEASE; CAUSE OF DEATH; CEREBROVASCULAR ACCIDENT; FEMALE; FOLLOW UP; GERMANY; HIGH RISK PATIENT; HUMAN; ITALY; LUXEMBOURG; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; NETHERLANDS; OBSERVATIONAL STUDY; PATIENT SAFETY; PERCUTANEOUS AORTIC VALVE; POSTOPERATIVE HEMORRHAGE; TRANSCATHETER AORTIC VALVE IMPLANTATION; ADVERSE EFFECTS; AORTIC VALVE; AORTIC VALVE STENOSIS; CLINICAL TRIAL; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; PROCEDURES; RISK FACTOR; SURGERY; TREATMENT OUTCOME; VERY ELDERLY;

EID: 84962385233     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV11I11A254     Document Type: Article
Times cited : (7)

References (28)
  • 4
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, Laborde JC, de Jaegere P, Serruys PW. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008;4:242-9.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    De Jaegere, P.12    Serruys, P.W.13
  • 5
    • 78651468809 scopus 로고    scopus 로고
    • Percutaneous transarterial aortic valve implantation: What do we know?
    • Webb J, Cribier A. Percutaneous transarterial aortic valve implantation: what do we know? Eur Heart J. 2011;32:140-7.
    • (2011) Eur Heart J. , vol.32 , pp. 140-147
    • Webb, J.1    Cribier, A.2
  • 7
  • 11
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    • Abdel-Wahab M, Zahn R, Horack M, Gerckens U, Schuler G, Sievert H, Eggebrecht H, Senges J, Richardt G; German transcatheter aortic valve interventions registry investigators. Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart. 2011;97:899-906.
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3    Gerckens, U.4    Schuler, G.5    Sievert, H.6    Eggebrecht, H.7    Senges, J.8    Richardt, G.9
  • 13
    • 84862533949 scopus 로고    scopus 로고
    • From pressure overload to volume overload: Aortic regurgitation after transcatheter aortic valve implantation
    • Gotzmann M, Lindstaedt M, Mügge A. From pressure overload to volume overload: aortic regurgitation after transcatheter aortic valve implantation. Am Heart J. 2012;163:903-11.
    • (2012) Am Heart J. , vol.163 , pp. 903-911
    • Gotzmann, M.1    Lindstaedt, M.2    Mügge, A.3
  • 15
    • 84867782594 scopus 로고    scopus 로고
    • Ventricular embolization of Edwards SAPIEN prosthesis following transcatheter aortic valve implantation
    • Gul M, Erkanli K, Erol MK, Bakir I. Ventricular embolization of Edwards SAPIEN prosthesis following transcatheter aortic valve implantation. J Invasive Cardiol. 2012;24:537-8.
    • (2012) J Invasive Cardiol. , vol.24 , pp. 537-538
    • Gul, M.1    Erkanli, K.2    Erol, M.K.3    Bakir, I.4
  • 17
    • 58149234535 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement malposition and embolization: Innovation brings solutions also new challenges
    • Tuzcu EM. Transcatheter aortic valve replacement malposition and embolization: innovation brings solutions also new challenges. Catheter Cardiovasc Interv. 2008;72:579-80.
    • (2008) Catheter Cardiovasc Interv. , vol.72 , pp. 579-580
    • Tuzcu, E.M.1
  • 24
    • 84862181480 scopus 로고    scopus 로고
    • Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3, 519 patients from 16 studies
    • Généreux P, Head SJ, Van Mieghem NM, Kodali S, Kirtane AJ, Xu K, Smith C, Serruys PW, Kappetein AP, Leon MB. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3, 519 patients from 16 studies. J Am Coll Cardiol. 2012;59:2317-26.
    • (2012) J Am Coll Cardiol. , vol.59 , pp. 2317-2326
    • Généreux, P.1    Head, S.J.2    Van Mieghem, N.M.3    Kodali, S.4    Kirtane, A.J.5    Xu, K.6    Smith, C.7    Serruys, P.W.8    Kappetein, A.P.9    Leon, M.B.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.