메뉴 건너뛰기




Volumn 95, Issue 11, 2016, Pages

Reproducibility of kidney perfusion measurements with arterial spin labeling at 1.5 tesla MRI combined with semiautomatic segmentation for differential cortical and medullary assessment

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERIAL SPIN LABELING; ARTICLE; CLINICAL ARTICLE; FEMALE; HUMAN; IMAGE ANALYSIS; KIDNEY CORTEX; KIDNEY MEDULLA; KIDNEY PERFUSION; MALE; MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PILOT STUDY; PRIORITY JOURNAL; REPRODUCIBILITY; SPIN LABELING; CLINICAL TRIAL; KIDNEY CIRCULATION; MIDDLE AGED; PROCEDURES; VASCULARIZATION;

EID: 84962007714     PISSN: 00257974     EISSN: 15365964     Source Type: Journal    
DOI: 10.1097/MD.0000000000003083     Document Type: Article
Times cited : (20)

References (46)
  • 1
    • 34447619345 scopus 로고    scopus 로고
    • Evidence that renal arterial-venous oxygen shunting contributes to dynamic regulation of renal oxygenation
    • Leong CL, Anderson WP, O'Connor PM, et al. Evidence that renal arterial-venous oxygen shunting contributes to dynamic regulation of renal oxygenation. Am J Physiol Renal Physiol. 2007;292: 1726-1733.
    • (2007) Am J Physiol Renal Physiol , vol.292 , pp. 1726-1733
    • Leong, C.L.1    Anderson, W.P.2    O'Connor, P.M.3
  • 2
    • 0026773056 scopus 로고
    • Determinants of intrarenal oxygenation: Factors in acute renal failure
    • Rosen S, Epstein FH, Brezis M. Determinants of intrarenal oxygenation: factors in acute renal failure. Ren Fail. 1992;14:321-325.
    • (1992) Ren Fail , vol.14 , pp. 321-325
    • Rosen, S.1    Epstein, F.H.2    Brezis, M.3
  • 3
    • 37149022294 scopus 로고    scopus 로고
    • Monitoring renal function and limitations of renal function tests
    • Prigent A. Monitoring renal function and limitations of renal function tests. Semin Nucl Med. 2008;38:32-46.
    • (2008) Semin Nucl Med , vol.38 , pp. 32-46
    • Prigent, A.1
  • 4
    • 65649142017 scopus 로고    scopus 로고
    • A new equation to estimate glomerular filtration rate
    • Levey AS, Stevens LA, Schmid CH, et al. A new equation to estimate glomerular filtration rate. Ann Intern Med. 2009;150:604-612.
    • (2009) Ann Intern Med , vol.150 , pp. 604-612
    • Levey, A.S.1    Stevens, L.A.2    Schmid, C.H.3
  • 5
    • 0015530123 scopus 로고
    • Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-aminohippurate
    • Cole BR, Giangiacomo J, Ingelfinger JR, et al. Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-aminohippurate. N Engl J Med. 1972;287:1109-1114.
    • (1972) N Engl J Med , vol.287 , pp. 1109-1114
    • Cole, B.R.1    Giangiacomo, J.2    Ingelfinger, J.R.3
  • 6
    • 0033917482 scopus 로고    scopus 로고
    • Color Doppler sonographic appearance of renal perforating vessels in subjects with normal and impaired renal function
    • Bertolotto M, Quaia E, Galli G, et al. Color Doppler sonographic appearance of renal perforating vessels in subjects with normal and impaired renal function. J Clin Ultrasound. 2000;28:267-276.
    • (2000) J Clin Ultrasound , vol.28 , pp. 267-276
    • Bertolotto, M.1    Quaia, E.2    Galli, G.3
  • 7
    • 0028895220 scopus 로고
    • The pulsatility index and the resistive index in renal arteries in patients with hypertension and chronic renal failure
    • Petersen LJ, Petersen JR, Ladefoged SD, et al. The pulsatility index and the resistive index in renal arteries in patients with hypertension and chronic renal failure. Nephrol Dial Transplant. 1995;10:2060-2064.
    • (1995) Nephrol Dial Transplant , vol.10 , pp. 2060-2064
    • Petersen, L.J.1    Petersen, J.R.2    Ladefoged, S.D.3
  • 9
    • 77953010635 scopus 로고    scopus 로고
    • Renal resistive index - A valid tool to assess renal endothelial function in humans?
    • Raff U, Schwarz TK, Schmidt BM, et al. Renal resistive index-a valid tool to assess renal endothelial function in humans? Nephrol Dial Transplant. 2010;25:1869-1874.
    • (2010) Nephrol Dial Transplant , vol.25 , pp. 1869-1874
    • Raff, U.1    Schwarz, T.K.2    Schmidt, B.M.3
  • 10
    • 84925847115 scopus 로고    scopus 로고
    • Pathophysiology of sepsis-induced acute kidney injury: The role of global renal blood flow and renal vascular resistance
    • Bougle A, Duranteau J. Pathophysiology of sepsis-induced acute kidney injury: the role of global renal blood flow and renal vascular resistance. Contrib Nephrol. 2011;174:89-97.
    • (2011) Contrib Nephrol , vol.174 , pp. 89-97
    • Bougle, A.1    Duranteau, J.2
  • 11
    • 0030116706 scopus 로고    scopus 로고
    • Measurement of renal function with technetium-99m-MAG3 in children and adults
    • Russell CD, Taylor AT, Dubovsky EV. Measurement of renal function with technetium-99m-MAG3 in children and adults. J Nucl Med. 1996;37:588-593.
    • (1996) J Nucl Med , vol.37 , pp. 588-593
    • Russell, C.D.1    Taylor, A.T.2    Dubovsky, E.V.3
  • 12
    • 33645004418 scopus 로고    scopus 로고
    • Nuclear medicine procedures for the diagnosis of acute and chronic renal failure
    • Haufe SE, Riedmuller K, Haberkorn U. Nuclear medicine procedures for the diagnosis of acute and chronic renal failure. Nephron Clin Pract. 2006;103:77-84.
    • (2006) Nephron Clin Pract , vol.103 , pp. 77-84
    • Haufe, S.E.1    Riedmuller, K.2    Haberkorn, U.3
  • 13
    • 34548671875 scopus 로고    scopus 로고
    • Gadolinium-enhanced MR imaging and nephrogenic systemic fibrosis: Retrospective study of a renal replacement therapy cohort
    • Collidge TA, Thomson PC, Mark PB, et al. Gadolinium-enhanced MR imaging and nephrogenic systemic fibrosis: retrospective study of a renal replacement therapy cohort. Radiology. 2007;245: 168-175.
    • (2007) Radiology , vol.245 , pp. 168-175
    • Collidge, T.A.1    Thomson, P.C.2    Mark, P.B.3
  • 14
    • 0033496776 scopus 로고    scopus 로고
    • Measuring cerebral blood flow using magnetic resonance imaging techniques
    • Calamante F, Thomas DL, Pell GS, et al. Measuring cerebral blood flow using magnetic resonance imaging techniques. J Cereb Blood Flow Metab. 1999;19:701-735.
    • (1999) J Cereb Blood Flow Metab , vol.19 , pp. 701-735
    • Calamante, F.1    Thomas, D.L.2    Pell, G.S.3
  • 16
    • 0842285725 scopus 로고    scopus 로고
    • FAIR true-FISP perfusion imaging of the kidneys
    • Martirosian P, Klose U, Mader I, et al. FAIR true-FISP perfusion imaging of the kidneys. Magn Reson Med. 2004;51: 353-361.
    • (2004) Magn Reson Med , vol.51 , pp. 353-361
    • Martirosian, P.1    Klose, U.2    Mader, I.3
  • 17
    • 33344460870 scopus 로고    scopus 로고
    • Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: Initial experience
    • Fenchel M, Martirosian P, Langanke J, et al. Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: initial experience. Radiology. 2006; 238:1013-1021.
    • (2006) Radiology , vol.238 , pp. 1013-1021
    • Fenchel, M.1    Martirosian, P.2    Langanke, J.3
  • 18
    • 77956268805 scopus 로고    scopus 로고
    • Magnetic resonance perfusion imaging without contrast media
    • Martirosian P, Boss A, Schraml C, et al. Magnetic resonance perfusion imaging without contrast media. Eur J Nucl Med Mol Imaging. 2010;37:52-64.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 52-64
    • Martirosian, P.1    Boss, A.2    Schraml, C.3
  • 19
    • 33747590330 scopus 로고    scopus 로고
    • Non-invasive measurement of perfusion: A critical review of arterial spin labelling techniques
    • Petersen ET, Zimine I, Ho YC, et al. Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques. Br J Radiol. 2006;79:688-701.
    • (2006) Br J Radiol , vol.79 , pp. 688-701
    • Petersen, E.T.1    Zimine, I.2    Ho, Y.C.3
  • 20
    • 0042829381 scopus 로고    scopus 로고
    • Non-invasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging
    • Montet X, Ivancevic MK, Belenger J, et al. Non-invasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging. Invest Radiol. 2003;38:584-592.
    • (2003) Invest Radiol , vol.38 , pp. 584-592
    • Montet, X.1    Ivancevic, M.K.2    Belenger, J.3
  • 21
    • 7044263028 scopus 로고    scopus 로고
    • Renal disease: Value of functional magnetic resonance imaging with flow and perfusion measurements
    • Michaely HJ, Schoenberg SO, Ittrich C, et al. Renal disease: value of functional magnetic resonance imaging with flow and perfusion measurements. Invest Radiol. 2004;39:698-705.
    • (2004) Invest Radiol , vol.39 , pp. 698-705
    • Michaely, H.J.1    Schoenberg, S.O.2    Ittrich, C.3
  • 22
    • 77950465247 scopus 로고    scopus 로고
    • Preserved oxygenation despite reduced blood flow in poststenotic kidneys in human atherosclerotic renal artery stenosis
    • Gloviczki ML, Glockner JF, Lerman LO, et al. Preserved oxygenation despite reduced blood flow in poststenotic kidneys in human atherosclerotic renal artery stenosis. Hypertension. 2010;55:961-966.
    • (2010) Hypertension , vol.55 , pp. 961-966
    • Gloviczki, M.L.1    Glockner, J.F.2    Lerman, L.O.3
  • 23
    • 75749157786 scopus 로고    scopus 로고
    • Measuring perfusion and permeability in renal cell carcinoma with dynamic contrast-enhanced MRI: A pilot study
    • Notohamiprodjo M, Sourbron S, Staehler M, et al. Measuring perfusion and permeability in renal cell carcinoma with dynamic contrast-enhanced MRI: a pilot study. J Magn Reson Imaging. 2010;31:490-501.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 490-501
    • Notohamiprodjo, M.1    Sourbron, S.2    Staehler, M.3
  • 24
    • 0034161989 scopus 로고    scopus 로고
    • Heterogeneity of angiogen-esis and blood vessel maturation in human tumors: Implications for antiangiogenic tumor therapies
    • Eberhard A, Kahlert S, Goede V, et al. Heterogeneity of angiogen-esis and blood vessel maturation in human tumors: implications for antiangiogenic tumor therapies. Cancer Res. 2000;60:1388-1393.
    • (2000) Cancer Res , vol.60 , pp. 1388-1393
    • Eberhard, A.1    Kahlert, S.2    Goede, V.3
  • 25
    • 77952089937 scopus 로고    scopus 로고
    • Quantification of renal allograft perfusion using arterial spin labeling MRI: Initial results
    • Lanzman RS, Wittsack HJ, Martirosian P, et al. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results. Eur Radiol. 2010;20:1485-1491.
    • (2010) Eur Radiol , vol.20 , pp. 1485-1491
    • Lanzman, R.S.1    Wittsack, H.J.2    Martirosian, P.3
  • 26
    • 84863393460 scopus 로고    scopus 로고
    • Repeatability of renal arterial spin labelling MRI in healthy subjects
    • Cutajar M, Thomas DL, Banks T, et al. Repeatability of renal arterial spin labelling MRI in healthy subjects. MAGMA. 2012;25:145-153.
    • (2012) MAGMA , vol.25 , pp. 145-153
    • Cutajar, M.1    Thomas, D.L.2    Banks, T.3
  • 27
    • 78649927683 scopus 로고    scopus 로고
    • Arterial spin labeling MRI for assessment of perfusion in native and transplanted kidneys
    • Artz NS, Sadowski EA, Wentland AL, et al. Arterial spin labeling MRI for assessment of perfusion in native and transplanted kidneys. Magn Reson Imaging. 2011;29:74-82.
    • (2011) Magn Reson Imaging , vol.29 , pp. 74-82
    • Artz, N.S.1    Sadowski, E.A.2    Wentland, A.L.3
  • 28
    • 77950190399 scopus 로고    scopus 로고
    • Measurement of kidney perfusion by magnetic resonance imaging: Comparison of MRI with arterial spin labeling to para-aminohippuric acid plasma clearance in male subjects with metabolic syndrome
    • Ritt M, Janka R, Schneider MP, et al. Measurement of kidney perfusion by magnetic resonance imaging: comparison of MRI with arterial spin labeling to para-aminohippuric acid plasma clearance in male subjects with metabolic syndrome. Nephrol Dial Transplant. 2010;25:1126-1133.
    • (2010) Nephrol Dial Transplant , vol.25 , pp. 1126-1133
    • Ritt, M.1    Janka, R.2    Schneider, M.P.3
  • 29
    • 84893171318 scopus 로고    scopus 로고
    • Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla
    • Gillis KA, McComb C, Foster JE, et al. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla. BMC Nephrol. 2014;15:23.
    • (2014) BMC Nephrol , vol.15 , pp. 23
    • Gillis, K.A.1    McComb, C.2    Foster, J.E.3
  • 31
  • 32
    • 0020102027 scopus 로고
    • Least squares quantization in PCM
    • Lloyd SP. Least squares quantization in PCM. IEEE Trans Inform Theory. 1982;28:129-137.
    • (1982) IEEE Trans Inform Theory , vol.28 , pp. 129-137
    • Lloyd, S.P.1
  • 33
    • 79958266556 scopus 로고    scopus 로고
    • Reproducibility of renal perfusion MR imaging in native and transplanted kidneys using non-contrast arterial spin labeling
    • Artz NS, Sadowski EA, Wentland AL, et al. Reproducibility of renal perfusion MR imaging in native and transplanted kidneys using non-contrast arterial spin labeling. J Magn Reson Imaging. 2011;33:1414-1421.
    • (2011) J Magn Reson Imaging , vol.33 , pp. 1414-1421
    • Artz, N.S.1    Sadowski, E.A.2    Wentland, A.L.3
  • 34
    • 81555212314 scopus 로고    scopus 로고
    • Renal perfusion 3-T MR imaging: A comparative study of arterial spin labeling and dynamic contrast-enhanced techniques
    • Wu WC, Su MY, Chang CC, et al. Renal perfusion 3-T MR imaging: a comparative study of arterial spin labeling and dynamic contrast-enhanced techniques. Radiology. 2011;261: 845-853.
    • (2011) Radiology , vol.261 , pp. 845-853
    • Wu, W.C.1    Su, M.Y.2    Chang, C.C.3
  • 35
    • 29144434140 scopus 로고    scopus 로고
    • High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media
    • Boss A, Martirosian P, Graf H, et al. High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media. Rofo. 2005;177:1625-1630.
    • (2005) Rofo , vol.177 , pp. 1625-1630
    • Boss, A.1    Martirosian, P.2    Graf, H.3
  • 36
    • 0015530123 scopus 로고
    • Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-aminohippurate
    • Cole BR, Giangiacomo J, Ingelfinger JR, et al. Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-aminohippurate. N Engl J Med. 1972;287:1109-1114.
    • (1972) N Engl J Med , vol.287 , pp. 1109-1114
    • Cole, B.R.1    Giangiacomo, J.2    Ingelfinger, J.R.3
  • 37
    • 0018832394 scopus 로고
    • Measurement of renal clearance of inulin and PAH in the steady state without urine collection
    • Schnurr E, Lahme W, Kuppers H. Measurement of renal clearance of inulin and PAH in the steady state without urine collection. Clin Nephrol. 1980;13:26-29.
    • (1980) Clin Nephrol , vol.13 , pp. 26-29
    • Schnurr, E.1    Lahme, W.2    Kuppers, H.3
  • 38
    • 65249115842 scopus 로고    scopus 로고
    • Arterial spin-labeled MR perfusion imaging: Clinical applications
    • Pollock JM, Tan H, Kraft RA, et al. Arterial spin-labeled MR perfusion imaging: clinical applications. Magn Reson Imaging Clin N Am. 2009;17:315-338.
    • (2009) Magn Reson Imaging Clin N Am , vol.17 , pp. 315-338
    • Pollock, J.M.1    Tan, H.2    Kraft, R.A.3
  • 39
    • 84857186227 scopus 로고    scopus 로고
    • Reversibility of the effects of aliskiren in the renal versus systemic circulation
    • Schneider MP, Janka R, Ziegler T, et al. Reversibility of the effects of aliskiren in the renal versus systemic circulation. Clin J Am Soc Nephrol. 2012;7:258-264.
    • (2012) Clin J Am Soc Nephrol , vol.7 , pp. 258-264
    • Schneider, M.P.1    Janka, R.2    Ziegler, T.3
  • 40
    • 84879947581 scopus 로고    scopus 로고
    • Vascular and renal hemodynamic changes after renal denervation
    • Ott C, Janka R, Schmid A, et al. Vascular and renal hemodynamic changes after renal denervation. Clin J Am Soc Nephrol. 2013;8:1195-1201.
    • (2013) Clin J Am Soc Nephrol , vol.8 , pp. 1195-1201
    • Ott, C.1    Janka, R.2    Schmid, A.3
  • 41
    • 84870250946 scopus 로고    scopus 로고
    • Renal blood flow, fractional excretion of sodium and acute kidney injury: Time for a new paradigm?
    • Prowle J, Bagshaw SM, Bellomo R. Renal blood flow, fractional excretion of sodium and acute kidney injury: time for a new paradigm? Curr Opin Crit Care. 2012;18:585-592.
    • (2012) Curr Opin Crit Care , vol.18 , pp. 585-592
    • Prowle, J.1    Bagshaw, S.M.2    Bellomo, R.3
  • 42
    • 84866124993 scopus 로고    scopus 로고
    • The role of the kidney in heart failure
    • Metra M, Cotter G, Gheorghiade M, et al. The role of the kidney in heart failure. Eur Heart J. 2012;33:2135-2142.
    • (2012) Eur Heart J , vol.33 , pp. 2135-2142
    • Metra, M.1    Cotter, G.2    Gheorghiade, M.3
  • 43
    • 77958101209 scopus 로고    scopus 로고
    • Renovascular hypertension and ischemic nephropathy
    • Textor SC, Lerman L. Renovascular hypertension and ischemic nephropathy. Am J Hypertens. 2010;23:1159-1169.
    • (2010) Am J Hypertens , vol.23 , pp. 1159-1169
    • Textor, S.C.1    Lerman, L.2
  • 44
    • 84870031653 scopus 로고    scopus 로고
    • Arterial spin-labeling MR imaging of renal masses: Correlation with histopathologic findings
    • Lanzman RS, Robson PM, Sun MR, et al. Arterial spin-labeling MR imaging of renal masses: correlation with histopathologic findings. Radiology. 2012;265:799-808.
    • (2012) Radiology , vol.265 , pp. 799-808
    • Lanzman, R.S.1    Robson, P.M.2    Sun, M.R.3
  • 45
    • 84863703744 scopus 로고    scopus 로고
    • Histogram analysis of renal arterial spin labeling perfusion data reveals differences between volunteers and patients with mild chronic kidney disease
    • Rossi C, Artunc F, Martirosian P, et al. Histogram analysis of renal arterial spin labeling perfusion data reveals differences between volunteers and patients with mild chronic kidney disease. Invest Radiol. 2012;47:490-496.
    • (2012) Invest Radiol , vol.47 , pp. 490-496
    • Rossi, C.1    Artunc, F.2    Martirosian, P.3
  • 46
    • 77952709881 scopus 로고    scopus 로고
    • Multislice perfusion of the kidneys using parallel imaging: Image acquisition and analysis strategies
    • Gardener AG, Francis ST. Multislice perfusion of the kidneys using parallel imaging: image acquisition and analysis strategies. Magn Reson Med. 2010;63:1627-1636.
    • (2010) Magn Reson Med , vol.63 , pp. 1627-1636
    • Gardener, A.G.1    Francis, S.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.