메뉴 건너뛰기




Volumn 62, Issue 2, 2016, Pages 123-128

Analysis of microcirculation measurements by novice users trained by a standardized interactive tutorial: An inter-observer variability study

Author keywords

analysis; education; Microcirculation; tutorial

Indexed keywords

CLINICAL ARTICLE; COMPUTER PROGRAM; HUMAN; HUMAN TISSUE; KAPPA STATISTICS; MICROCIRCULATION; SIMULATION TRAINING; VIDEORECORDING; VOLUNTEER; AUTOMATION; CANADA; CARDIOLOGY; CLINICAL TRIAL; EDUCATION; EUROPE; MOUTH; MULTICENTER STUDY; OBSERVER VARIATION; SOFTWARE; STATISTICAL MODEL; VASCULARIZATION;

EID: 84961833532     PISSN: 13860291     EISSN: 18758622     Source Type: Journal    
DOI: 10.3233/CH-151958     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 0035725780 scopus 로고    scopus 로고
    • Reproducibility of skin microcirculatory measurements in humans, with special emphasis on capillaroscopy
    • E.J. Abbink, H. Wollersheim, P.M. Netten and P. Smits, Reproducibility of skin microcirculatory measurements in humans, with special emphasis on capillaroscopy, Vasc Med 6 (2001), 203-210.
    • (2001) Vasc Med , vol.6 , pp. 203-210
    • Abbink, E.J.1    Wollersheim, H.2    Netten, P.M.3    Smits, P.4
  • 2
    • 85132475528 scopus 로고    scopus 로고
    • Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation
    • G. Aykut, G. Veenstra, C. Scorcella, C. Ince and C. Boerma, Cytocam-IDF (incident dark field illumination) imaging for bedside monitoring of the microcirculation, Intensive Care Med Exp 3 (2015), 4.
    • (2015) Intensive Care Med Exp , vol.3 , pp. 4
    • Aykut, G.1    Veenstra, G.2    Scorcella, C.3    Ince, C.4    Boerma, C.5
  • 3
    • 0035147476 scopus 로고    scopus 로고
    • Comparison of microcirculation patterns and MIB-1 immunoreactivity in iris and posterior uveal melanoma
    • I. Chowers, R. Folberg, N. Livni and J. Pe'er, Comparison of microcirculation patterns and MIB-1 immunoreactivity in iris and posterior uveal melanoma, Ophthalmology 108 (2001), 367-371.
    • (2001) Ophthalmology , vol.108 , pp. 367-371
    • Chowers, I.1    Folberg, R.2    Livni, N.3    Pe'Er, J.4
  • 5
    • 38349088317 scopus 로고    scopus 로고
    • Fast-track microcirculation analysis
    • P.W.G. Elbers, Fast-track microcirculation analysis, Crit Care 11 (2007), 426.
    • (2007) Crit Care , vol.11 , pp. 426
    • Elbers, P.W.G.1
  • 6
    • 84925666680 scopus 로고    scopus 로고
    • Microcirculation in the ICU: A small step for monitoring, a giant leap for tissue viability∗
    • R. Favory and D. Mathieu, Microcirculation in the ICU: A small step for monitoring, a giant leap for tissue viability∗, Crit Care Med 43 (2015), 233-234.
    • (2015) Crit Care Med , vol.43 , pp. 233-234
    • Favory, R.1    Mathieu, D.2
  • 7
    • 36248992450 scopus 로고    scopus 로고
    • Sidestream Dark Field (SDF) imaging: A novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation
    • P.T. Goedhart, M. Khalilzada, R. Bezemer, J. Merza and C. Ince, Sidestream Dark Field (SDF) imaging: A novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation, Opt Express 15 (2007), 15101-15114.
    • (2007) Opt Express , vol.15 , pp. 15101-15114
    • Goedhart, P.T.1    Khalilzada, M.2    Bezemer, R.3    Merza, J.4    Ince, C.5
  • 9
    • 84918568714 scopus 로고    scopus 로고
    • Excellent inter- and intra-observer reproducibility of microvascular tests using laser speckle contrast imaging
    • A. Humeau-Heurtier, P. Abraham, S. Durand and G. Mahé, Excellent inter- and intra-observer reproducibility of microvascular tests using laser speckle contrast imaging, Clin Hemorheol Microcirc 58(3) (2014), 439-446.
    • (2014) Clin Hemorheol Microcirc , vol.58 , Issue.3 , pp. 439-446
    • Humeau-Heurtier, A.1    Abraham, P.2    Durand, S.3    Mahé, G.4
  • 10
    • 84857235358 scopus 로고    scopus 로고
    • Evaluation of sublingual microcirculatory blood flow in the critically ill
    • M. Sallisalmi, N. Oksala, V. Pettilä and J. Tenhunen, Evaluation of sublingual microcirculatory blood flow in the critically ill, Acta Anaesthesiol Scand 56 (2012), 298-306.
    • (2012) Acta Anaesthesiol Scand , vol.56 , pp. 298-306
    • Sallisalmi, M.1    Oksala, N.2    Pettilä, V.3    Tenhunen, J.4
  • 11
    • 84942989868 scopus 로고    scopus 로고
    • Hemodynamic management of septic shock: Is it time for "individual Goal-Directed Hemodynamic Therapy" and for specifically targeting the microcirculation?
    • B. Saugel, C.J. Trepte, K. Heckel, J.Y. Wagner and D.A. Reuter, Hemodynamic management of septic shock: Is it time for "Individual Goal-Directed Hemodynamic Therapy" and for specifically targeting the microcirculation? Shock (2015).
    • (2015) Shock
    • Saugel, B.1    Trepte, C.J.2    Heckel, K.3    Wagner, J.Y.4    Reuter, D.A.5
  • 12
    • 84863927475 scopus 로고    scopus 로고
    • Differential effects of intravenous anesthetics on hepatosplanchnic microcirculation in rats: Sidestream dark-field imaging study
    • Z. Turek, C. Lehmann, R. Parizkova, J. Samek, M. Kaska and V. Cerny, Differential effects of intravenous anesthetics on hepatosplanchnic microcirculation in rats: Sidestream dark-field imaging study, Clin Hemorheol Microcirc 51 (2012), 213-223.
    • (2012) Clin Hemorheol Microcirc , vol.51 , pp. 213-223
    • Turek, Z.1    Lehmann, C.2    Parizkova, R.3    Samek, J.4    Kaska, M.5    Cerny, V.6
  • 13
    • 18544372466 scopus 로고    scopus 로고
    • Understanding interobserver agreement: The kappa statistic
    • A.J. Viera and J.M. Garrett, Understanding interobserver agreement: The kappa statistic, Fam Med 37 (2005), 360-363.
    • (2005) Fam Med , vol.37 , pp. 360-363
    • Viera, A.J.1    Garrett, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.