-
1
-
-
79954633778
-
Évolution des pratiques transfusionnelles en néonatalogie : recommandations actuelles
-
Plaisant F. Évolution des pratiques transfusionnelles en néonatalogie : recommandations actuelles. Transfus Clin Biol 2011, 18:262-268.
-
(2011)
Transfus Clin Biol
, vol.18
, pp. 262-268
-
-
Plaisant, F.1
-
2
-
-
0345794056
-
Transfusion de globules rouges homologues : produits, indications, alternatives.
-
[consulté ce jour le 22/12/2015].
-
Afssaps. Transfusion de globules rouges homologues : produits, indications, alternatives. ; [consulté ce jour le 22/12/2015]. http://www.hemovigilance-cncrh.fr/Indicat/cgr_hemato_onco.pdf.
-
-
-
-
3
-
-
58249128175
-
Current controversies in the management of the anemia of prematurity
-
Bishara N., Ohls R.K. Current controversies in the management of the anemia of prematurity. Sem Perinatol 2009, 33:29-34.
-
(2009)
Sem Perinatol
, vol.33
, pp. 29-34
-
-
Bishara, N.1
Ohls, R.K.2
-
4
-
-
3042797318
-
Pratique de la transfusion en période néonatale
-
Pichon C. Pratique de la transfusion en période néonatale. J Pediatr Puericult 2004, 17:213-219.
-
(2004)
J Pediatr Puericult
, vol.17
, pp. 213-219
-
-
Pichon, C.1
-
5
-
-
84905215924
-
The timing of cord clamping and oxidative stress in term newborns
-
Diaz-Castro J., Florido J., Kajarabille N., et al. The timing of cord clamping and oxidative stress in term newborns. Pediatrics 2014, 134:257-264.
-
(2014)
Pediatrics
, vol.134
, pp. 257-264
-
-
Diaz-Castro, J.1
Florido, J.2
Kajarabille, N.3
-
6
-
-
84903122038
-
Placental transfusion strategies in very preterm neonates: a systematic review and meta-analysis
-
Backes C.H., Rivera B.K., Haque U., et al. Placental transfusion strategies in very preterm neonates: a systematic review and meta-analysis. Obstet Gynecol 2014, 124:47-56.
-
(2014)
Obstet Gynecol
, vol.124
, pp. 47-56
-
-
Backes, C.H.1
Rivera, B.K.2
Haque, U.3
-
7
-
-
84873031393
-
Early erythropoietin for preventing red blood cell transfusion in preterm and/or low birth weight infants
-
Ohlsson A., Aher S.M. Early erythropoietin for preventing red blood cell transfusion in preterm and/or low birth weight infants. Cochrane Database Syst Rev 2012, 9:CD004863.
-
(2012)
Cochrane Database Syst Rev
, vol.9
, pp. CD004863
-
-
Ohlsson, A.1
Aher, S.M.2
-
8
-
-
84866329110
-
Benefits of iron supplementation for low birth weight infants: a systematic review
-
Long H., Yi J.M., Hu P.L., et al. Benefits of iron supplementation for low birth weight infants: a systematic review. BMC Pediatr 2012, 12:99.
-
(2012)
BMC Pediatr
, vol.12
, pp. 99
-
-
Long, H.1
Yi, J.M.2
Hu, P.L.3
-
9
-
-
77953967793
-
Evaluation of anemia in children
-
Janus J., Moerschel S.K. Evaluation of anemia in children. Am Fam Physician 2010, 81:1462-1471.
-
(2010)
Am Fam Physician
, vol.81
, pp. 1462-1471
-
-
Janus, J.1
Moerschel, S.K.2
-
10
-
-
0036831246
-
Guidelines for assessing appropriateness of pediatric transfusion
-
Roseff S.D., Luban N.L., Manno C.S. Guidelines for assessing appropriateness of pediatric transfusion. Transfusion 2002, 42:1398-1413.
-
(2002)
Transfusion
, vol.42
, pp. 1398-1413
-
-
Roseff, S.D.1
Luban, N.L.2
Manno, C.S.3
-
11
-
-
0035487589
-
Red blood cell transfusion practices in very low birth weight infants in 1990s postsurfactant era
-
Beeram M.R., Krauss D.R., Riggs M.W. Red blood cell transfusion practices in very low birth weight infants in 1990s postsurfactant era. J Natl Med Assoc 2001, 93:405-409.
-
(2001)
J Natl Med Assoc
, vol.93
, pp. 405-409
-
-
Beeram, M.R.1
Krauss, D.R.2
Riggs, M.W.3
-
13
-
-
84887945134
-
Comparison of haemoglobin measurement methods in the operating theatre
-
Giraud B., Frasca D., Debaene B., et al. Comparison of haemoglobin measurement methods in the operating theatre. Br J Anaesth 2013, 111:946-954.
-
(2013)
Br J Anaesth
, vol.111
, pp. 946-954
-
-
Giraud, B.1
Frasca, D.2
Debaene, B.3
-
15
-
-
42149144890
-
Use of the HemoCue near patient testing device to measure the concentration of haemoglobin in suction fluid at elective caesarean section
-
Gupta A., Wrench I.J., Feast M.J., et al. Use of the HemoCue near patient testing device to measure the concentration of haemoglobin in suction fluid at elective caesarean section. Anaesthesia 2008, 63:531-534.
-
(2008)
Anaesthesia
, vol.63
, pp. 531-534
-
-
Gupta, A.1
Wrench, I.J.2
Feast, M.J.3
-
16
-
-
0024367057
-
Screening for anaemia: evaluation of a haemoglobinometer
-
Mills A.F., Meadows N. Screening for anaemia: evaluation of a haemoglobinometer. Arch Dis Child 1989, 64:1468-1471.
-
(1989)
Arch Dis Child
, vol.64
, pp. 1468-1471
-
-
Mills, A.F.1
Meadows, N.2
-
18
-
-
84155189164
-
Accuracy and precision of hemoglobin point-of-care testing during major pediatric surgery
-
Spielmann N., Mauch J., Madjdpour C., et al. Accuracy and precision of hemoglobin point-of-care testing during major pediatric surgery. Int J Lab Hematol 2012, 34:86-90.
-
(2012)
Int J Lab Hematol
, vol.34
, pp. 86-90
-
-
Spielmann, N.1
Mauch, J.2
Madjdpour, C.3
-
19
-
-
0023821099
-
HemoCue system for hemoglobin measurement. Evaluation in anemic and nonanemic children
-
Cohen A.R., Seidl-Friedman J. HemoCue system for hemoglobin measurement. Evaluation in anemic and nonanemic children. Am J Clin Pathol 1988, 90:302-305.
-
(1988)
Am J Clin Pathol
, vol.90
, pp. 302-305
-
-
Cohen, A.R.1
Seidl-Friedman, J.2
-
20
-
-
34247210183
-
Transfusion strategies for patients in pediatric intensive care units
-
Lacroix J., Hebert P.C., Hutchison J.S., et al. Transfusion strategies for patients in pediatric intensive care units. N Engl J Med 2007, 356:1609-1619.
-
(2007)
N Engl J Med
, vol.356
, pp. 1609-1619
-
-
Lacroix, J.1
Hebert, P.C.2
Hutchison, J.S.3
-
21
-
-
77954570493
-
Erythropoiesis, red cells, and the approach to anemia
-
Cambridge University Press
-
De Alarcon P., Cris Johnson M., Werner E. Erythropoiesis, red cells, and the approach to anemia. Neonatal hematology 2005, 40-57. Cambridge University Press.
-
(2005)
Neonatal hematology
, pp. 40-57
-
-
De Alarcon, P.1
Cris Johnson, M.2
Werner, E.3
-
22
-
-
78149469551
-
Anaemia of prematurity: pathophysiology and treatment
-
Strauss R.G. Anaemia of prematurity: pathophysiology and treatment. Blood Rev 2010, 24:221-225.
-
(2010)
Blood Rev
, vol.24
, pp. 221-225
-
-
Strauss, R.G.1
-
23
-
-
0036245366
-
Evaluation of the HemoCue compared with the Coulter STKS for measurement of neonatal haemoglobin
-
Rechner I.J., Twigg A., Davies A.F., et al. Evaluation of the HemoCue compared with the Coulter STKS for measurement of neonatal haemoglobin. Arch Dis Child Fetal Neonatal Ed 2002, 86:F188-F189.
-
(2002)
Arch Dis Child Fetal Neonatal Ed
, vol.86
, pp. F188-F189
-
-
Rechner, I.J.1
Twigg, A.2
Davies, A.F.3
-
24
-
-
0027409329
-
Fetal hemoglobin quantitations using the HemoCue system are rapid and accurate
-
Berry S.M., Dombrowski M.P., Blessed W.B., et al. Fetal hemoglobin quantitations using the HemoCue system are rapid and accurate. Obstet Gynecol 1993, 81:417-420.
-
(1993)
Obstet Gynecol
, vol.81
, pp. 417-420
-
-
Berry, S.M.1
Dombrowski, M.P.2
Blessed, W.B.3
-
25
-
-
0031595797
-
Evaluation of the HemoCue for measuring intra-operative haemoglobin concentrations: a comparison with the Coulter Max-M
-
Lardi A.M., Hirst C., Mortimer A.J., et al. Evaluation of the HemoCue for measuring intra-operative haemoglobin concentrations: a comparison with the Coulter Max-M. Anaesthesia 1998, 53:349-352.
-
(1998)
Anaesthesia
, vol.53
, pp. 349-352
-
-
Lardi, A.M.1
Hirst, C.2
Mortimer, A.J.3
-
26
-
-
80052966840
-
® hemoglobinometer in critically ill patients: a prospective observational study
-
® hemoglobinometer in critically ill patients: a prospective observational study. Minerva Anestesiol 2011, 77:979-985.
-
(2011)
Minerva Anestesiol
, vol.77
, pp. 979-985
-
-
Mimoz, O.1
Frasca, D.2
Medard, A.3
-
27
-
-
71849097489
-
Estimation of blood haemoglobin concentration using the HemoCue during caesarean section: the effect of sampling site
-
Richards N.A., Boyce H., Yentis S.M. Estimation of blood haemoglobin concentration using the HemoCue during caesarean section: the effect of sampling site. Int J Obstet Anesth 2010, 19:67-70.
-
(2010)
Int J Obstet Anesth
, vol.19
, pp. 67-70
-
-
Richards, N.A.1
Boyce, H.2
Yentis, S.M.3
-
28
-
-
79953174576
-
A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery
-
Miller R.D., Ward T.A., Shiboski S.C., et al. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg 2011, 112:858-863.
-
(2011)
Anesth Analg
, vol.112
, pp. 858-863
-
-
Miller, R.D.1
Ward, T.A.2
Shiboski, S.C.3
-
29
-
-
34249830113
-
Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening
-
Morris L.D., Osei-Bimpong A., McKeown D., et al. Evaluation of the utility of the HemoCue 301 haemoglobinometer for blood donor screening. Vox Sang 2007, 93:64-69.
-
(2007)
Vox Sang
, vol.93
, pp. 64-69
-
-
Morris, L.D.1
Osei-Bimpong, A.2
McKeown, D.3
-
30
-
-
33846852614
-
Reliability of HemoCue in patients with gastrointestinal bleeding
-
Van de Louw A., Lasserre N., Drouhin F., et al. Reliability of HemoCue in patients with gastrointestinal bleeding. Intensive Care Med 2007, 33:355-358.
-
(2007)
Intensive Care Med
, vol.33
, pp. 355-358
-
-
Van de Louw, A.1
Lasserre, N.2
Drouhin, F.3
-
31
-
-
79960699992
-
Determination of capillary hemoglobin levels using the HemoCue system in intensive care patients
-
Seguin P., Kleiber A., Chanavaz C., et al. Determination of capillary hemoglobin levels using the HemoCue system in intensive care patients. J Crit Care 2011, 26:423-427.
-
(2011)
J Crit Care
, vol.26
, pp. 423-427
-
-
Seguin, P.1
Kleiber, A.2
Chanavaz, C.3
-
32
-
-
0025143118
-
Rapid assessment of fetal hemoglobin concentration with the HemoCue system
-
Laifer S.A., Kuller J.A., Hill L.M. Rapid assessment of fetal hemoglobin concentration with the HemoCue system. Obstet Gynecol 1990, 76:723-724.
-
(1990)
Obstet Gynecol
, vol.76
, pp. 723-724
-
-
Laifer, S.A.1
Kuller, J.A.2
Hill, L.M.3
|