-
1
-
-
0032497292
-
Impact of atrial fibrillation on the risk of death: The Framingham Heart Study
-
Benjamin EJ, Wolf PA, D'Agostino RB, Silbershatz H, Kannel WB, Levy D,. Impact of atrial fibrillation on the risk of death: The Framingham Heart Study. Circulation 1998; 98: 946-952.
-
(1998)
Circulation
, vol.98
, pp. 946-952
-
-
Benjamin, E.J.1
Wolf, P.A.2
D'Agostino, R.B.3
Silbershatz, H.4
Kannel, W.B.5
Levy, D.6
-
2
-
-
0025779484
-
Atrial fibrillation as an independent risk factor for stroke: The Framingham Study
-
Wolf PA, Abbott RD, Kannel WB,. Atrial fibrillation as an independent risk factor for stroke: The Framingham Study. Stroke 1991; 22: 983-988.
-
(1991)
Stroke
, vol.22
, pp. 983-988
-
-
Wolf, P.A.1
Abbott, R.D.2
Kannel, W.B.3
-
3
-
-
84875508668
-
2012 focused update of the ESC guidelines for the management of atrial fibrillation: An update of the 2010 ESC guidelines for the management of atrial fibrillation - Developed with the special contribution of the European Heart Rhythm Association
-
Camm AJ, Lip GY, De Caterina R, Savelieva I, Atar D, Hohnloser SH, Hindricks G, et al., 2012 focused update of the ESC guidelines for the management of atrial fibrillation: An update of the 2010 ESC guidelines for the management of atrial fibrillation-developed with the special contribution of the European Heart Rhythm Association. Europace 2012; 14: 1385-1413.
-
(2012)
Europace
, vol.14
, pp. 1385-1413
-
-
Camm, A.J.1
Lip, G.Y.2
De Caterina, R.3
Savelieva, I.4
Atar, D.5
Hohnloser, S.H.6
Hindricks, G.7
-
4
-
-
74549189389
-
Characterization of conduction recovery after pulmonary vein isolation using the "single big cryoballoon" technique
-
Furnkranz A, Chun KR, Nuyens D, Metzner A, Koster I, Schmidt B, Ouyang F, et al., Characterization of conduction recovery after pulmonary vein isolation using the "single big cryoballoon" technique. Heart Rhythm 2010; 7: 184-190.
-
(2010)
Heart Rhythm
, vol.7
, pp. 184-190
-
-
Furnkranz, A.1
Chun, K.R.2
Nuyens, D.3
Metzner, A.4
Koster, I.5
Schmidt, B.6
Ouyang, F.7
-
5
-
-
84903377394
-
Quantitative assessment of a second-generation cryoballoon ablation catheter with new cooling technology-a perspective on potential implications on outcome
-
Knecht S, Kuehne M, Osswald S, Sticherling C,. Quantitative assessment of a second-generation cryoballoon ablation catheter with new cooling technology-a perspective on potential implications on outcome. J Interv Card Electr 2014; 40: 17-21.
-
(2014)
J Interv Card Electr
, vol.40
, pp. 17-21
-
-
Knecht, S.1
Kuehne, M.2
Osswald, S.3
Sticherling, C.4
-
6
-
-
84905859071
-
Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation
-
Furnkranz A, Bordignon S, Dugo D, Perotta L, Gunawardene M, Schulte-Hahn B, Nowak B, et al., Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 2014; 25: 840-844.
-
(2014)
J Cardiovasc Electrophysiol
, vol.25
, pp. 840-844
-
-
Furnkranz, A.1
Bordignon, S.2
Dugo, D.3
Perotta, L.4
Gunawardene, M.5
Schulte-Hahn, B.6
Nowak, B.7
-
7
-
-
84900452110
-
One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon
-
Metzner A, Reissmann B, Rausch P, Mathew S, Wohlmuth P, Tilz R, Rillig A, et al., One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circ Arrhythm Electrophysiol 2014; 7: 288-292.
-
(2014)
Circ Arrhythm Electrophysiol
, vol.7
, pp. 288-292
-
-
Metzner, A.1
Reissmann, B.2
Rausch, P.3
Mathew, S.4
Wohlmuth, P.5
Tilz, R.6
Rillig, A.7
-
8
-
-
69149107727
-
The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration
-
W-65-W-94.
-
Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JP, Clarke M, et al., The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration. Ann Intern Med 2009; 151:W-65-W-94.
-
(2009)
Ann Intern Med
, vol.151
-
-
Liberati, A.1
Altman, D.G.2
Tetzlaff, J.3
Mulrow, C.4
Gøtzsche, P.C.5
Ioannidis, J.P.6
Clarke, M.7
-
9
-
-
84876943025
-
Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon
-
Furnkranz A, Bordignon S, Schmidt B, Gunawardene M, Schulte-Hahn B, Urban V, Bode F, et al., Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon. J Cardiovasc Electrophysiol 2013; 24: 492-497.
-
(2013)
J Cardiovasc Electrophysiol
, vol.24
, pp. 492-497
-
-
Furnkranz, A.1
Bordignon, S.2
Schmidt, B.3
Gunawardene, M.4
Schulte-Hahn, B.5
Urban, V.6
Bode, F.7
-
10
-
-
84941189583
-
Impact on clinical outcome of premature interruption of cryoenergy delivery due to phrenic nerve palsy during second generation cryoballoon ablation for paroxysmal atrial fibrillation
-
Chierchia GB, Mugnai G, Hunuk B, Stroker E, Velagic V, Saitoh Y, Irfan G, et al., Impact on clinical outcome of premature interruption of cryoenergy delivery due to phrenic nerve palsy during second generation cryoballoon ablation for paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 2015; 26: 950-955.
-
(2015)
J Cardiovasc Electrophysiol
, vol.26
, pp. 950-955
-
-
Chierchia, G.B.1
Mugnai, G.2
Hunuk, B.3
Stroker, E.4
Velagic, V.5
Saitoh, Y.6
Irfan, G.7
-
11
-
-
84934439372
-
The impact of left atrial surface area and the second generation cryoballoon on clinical outcome of atrial fibrillation cryoablation
-
Greiss H, Berkowitsch A, Wojcik M, Zaltsberg S, Pajitnev D, Deubner N, Akkaya E, et al., The impact of left atrial surface area and the second generation cryoballoon on clinical outcome of atrial fibrillation cryoablation. Pacing Clin Electrophysiol 2015; 38: 815-824.
-
(2015)
Pacing Clin Electrophysiol
, vol.38
, pp. 815-824
-
-
Greiss, H.1
Berkowitsch, A.2
Wojcik, M.3
Zaltsberg, S.4
Pajitnev, D.5
Deubner, N.6
Akkaya, E.7
-
12
-
-
84922453089
-
Contact-force guided radiofrequency vs. Second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation - A prospective evaluation
-
Jourda F, Providencia R, Marijon E, Bouzeman A, Hireche H, Khoueiry Z, Cardin C, et al., Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation. Europace 2015; 17: 225-231.
-
(2015)
Europace
, vol.17
, pp. 225-231
-
-
Jourda, F.1
Providencia, R.2
Marijon, E.3
Bouzeman, A.4
Hireche, H.5
Khoueiry, Z.6
Cardin, C.7
-
13
-
-
84929235313
-
Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: A multicentre European evaluation
-
Squara F, Zhao A, Marijon E, Latcu DG, Providencia R, Di Giovanni G, Jauvert G, et al., Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: A multicentre European evaluation. Europace 2015; 17: 718-724.
-
(2015)
Europace
, vol.17
, pp. 718-724
-
-
Squara, F.1
Zhao, A.2
Marijon, E.3
Latcu, D.G.4
Providencia, R.5
Di Giovanni, G.6
Jauvert, G.7
-
14
-
-
84920649364
-
Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoon
-
Ciconte G, Ottaviano L, de Asmundis C, Baltogiannis G, Conte G, Sieira J, Di Giovanni G, et al., Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoon. Heart Rhythm 2015; 12: 60-66.
-
(2015)
Heart Rhythm
, vol.12
, pp. 60-66
-
-
Ciconte, G.1
Ottaviano, L.2
De Asmundis, C.3
Baltogiannis, G.4
Conte, G.5
Sieira, J.6
Di Giovanni, G.7
-
15
-
-
84960444279
-
One-year clinical outcome after pulmonary vein isolation in persistent atrial fibrillation using the second-generation 28 mm cryoballoon: A retrospective analysis
-
(in press; [Epub ahead of print]).
-
Lemes C, Wissner E, Lin T, Mathew S, Deiss S, Rillig A, Heeger C, et al., One-year clinical outcome after pulmonary vein isolation in persistent atrial fibrillation using the second-generation 28 mm cryoballoon: A retrospective analysis. Europace 2015 (in press; doi: 10.1093/europace/euv092 [Epub ahead of print]).
-
(2015)
Europace
-
-
Lemes, C.1
Wissner, E.2
Lin, T.3
Mathew, S.4
Deiss, S.5
Rillig, A.6
Heeger, C.7
-
16
-
-
84938089233
-
Acute and long-term outcomes of catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: A multicenter experience
-
Aryana A, Singh SM, Kowalski M, Pujara DK, Cohen AI, Singh SK, Aleong RG, et al., Acute and long-term outcomes of catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: A multicenter experience. J Cardiovasc Electrophysiol 2015; 26: 832-839.
-
(2015)
J Cardiovasc Electrophysiol
, vol.26
, pp. 832-839
-
-
Aryana, A.1
Singh, S.M.2
Kowalski, M.3
Pujara, D.K.4
Cohen, A.I.5
Singh, S.K.6
Aleong, R.G.7
-
17
-
-
84924352457
-
Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoondagger
-
Aytemir K, Gurses KM, Yalcin MU, Kocyigit D, Dural M, Evranos B, Yorgun H, et al., Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoondagger. Europace 2015; 17: 379-387.
-
(2015)
Europace
, vol.17
, pp. 379-387
-
-
Aytemir, K.1
Gurses, K.M.2
Yalcin, M.U.3
Kocyigit, D.4
Dural, M.5
Evranos, B.6
Yorgun, H.7
-
18
-
-
84925348374
-
Single 3-minute freeze for second-generation cryoballoon ablation: One-year follow-up after pulmonary vein isolation
-
Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, Saitoh Y, et al., Single 3-minute freeze for second-generation cryoballoon ablation: One-year follow-up after pulmonary vein isolation. Heart Rhythm 2015; 12: 673-680.
-
(2015)
Heart Rhythm
, vol.12
, pp. 673-680
-
-
Ciconte, G.1
De Asmundis, C.2
Sieira, J.3
Conte, G.4
Di Giovanni, G.5
Mugnai, G.6
Saitoh, Y.7
-
19
-
-
84937485639
-
Adenosine testing after second-generation cryoballoon ablation (ATSCA) study improves clinical success rate for atrial fibrillation
-
Kumar N, Dinh T, Phan K, Timmermans C, Philippens S, Dassen W, Vranken N, et al., Adenosine testing after second-generation cryoballoon ablation (ATSCA) study improves clinical success rate for atrial fibrillation. Europace 2015; 17: 871-876.
-
(2015)
Europace
, vol.17
, pp. 871-876
-
-
Kumar, N.1
Dinh, T.2
Phan, K.3
Timmermans, C.4
Philippens, S.5
Dassen, W.6
Vranken, N.7
-
20
-
-
84920926464
-
Second generation of cryoballoons can improve efficiency of cryoablation for atrial fibrillation
-
Liu J, Kaufmann J, Kriatselis C, Fleck E, Gerds-Li JH,. Second generation of cryoballoons can improve efficiency of cryoablation for atrial fibrillation. Pacing Clin Electrophysiol 2015; 38: 129-135.
-
(2015)
Pacing Clin Electrophysiol
, vol.38
, pp. 129-135
-
-
Liu, J.1
Kaufmann, J.2
Kriatselis, C.3
Fleck, E.4
Gerds-Li, J.H.5
-
21
-
-
84960405691
-
Shortening of freezing cycles provides equal outcome to standard ablation procedure using second-generation 28 mm cryoballoon after 15-month follow-up
-
(in press; [Epub ahead of print]).
-
Tebbenjohanns J, Hofer C, Bergmann L, Dedroogh M, Gaudin D, von Werder A, Ruhmkorf K, Shortening of freezing cycles provides equal outcome to standard ablation procedure using second-generation 28 mm cryoballoon after 15-month follow-up. Europace 2015 (in press; doi: 10.1093/europace/euv189 [Epub ahead of print]).
-
(2015)
Europace
-
-
Tebbenjohanns, J.1
Hofer, C.2
Bergmann, L.3
Dedroogh, M.4
Gaudin, D.5
Von Werder, A.6
Ruhmkorf, K.7
-
22
-
-
84939493165
-
One-year clinical success of a 'no-bonus' freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation
-
Wissner E, Heeger CH, Grahn H, Reissmann B, Wohlmuth P, Lemes C, Rausch P, et al., One-year clinical success of a 'no-bonus' freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation. Europace 2015; 17: 1236-1240.
-
(2015)
Europace
, vol.17
, pp. 1236-1240
-
-
Wissner, E.1
Heeger, C.H.2
Grahn, H.3
Reissmann, B.4
Wohlmuth, P.5
Lemes, C.6
Rausch, P.7
-
23
-
-
84884403178
-
Long-term outcomes of catheter ablation of atrial fibrillation: A systematic review and meta-analysis
-
Ganesan AN, Shipp NJ, Brooks AG, Kuklik P, Lau DH, Lim HS, Sullivan T, et al., Long-term outcomes of catheter ablation of atrial fibrillation: A systematic review and meta-analysis. J Am Heart Assoc 2013; 2: e4549 (doi: 10.1161/JAHA.112.004549).
-
(2013)
J Am Heart Assoc
, vol.2
, pp. e4549
-
-
Ganesan, A.N.1
Shipp, N.J.2
Brooks, A.G.3
Kuklik, P.4
Lau, D.H.5
Lim, H.S.6
Sullivan, T.7
-
24
-
-
84926654736
-
Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: A comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation
-
Ciconte G, Baltogiannis G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Saitoh Y, et al., Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: A comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation. Europace 2015; 17: 559-565.
-
(2015)
Europace
, vol.17
, pp. 559-565
-
-
Ciconte, G.1
Baltogiannis, G.2
De Asmundis, C.3
Sieira, J.4
Conte, G.5
Di Giovanni, G.6
Saitoh, Y.7
-
25
-
-
84876283750
-
Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: First results of the North American Arctic Front (STOP AF) pivotal trial
-
Packer DL, Kowal RC, Wheelan KR, Irwin JM, Champagne J, Guerra PG, Dubuc M, et al., Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: First results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol 2013; 61: 1713-1723.
-
(2013)
J Am Coll Cardiol
, vol.61
, pp. 1713-1723
-
-
Packer, D.L.1
Kowal, R.C.2
Wheelan, K.R.3
Irwin, J.M.4
Champagne, J.5
Guerra, P.G.6
Dubuc, M.7
-
26
-
-
84879907362
-
Medium-term results of cryoballoon ablation of the pulmonary veins in patients with paroxysmal and persistent atrial fibrillation. First experience of a Spanish center
-
Ferrero-de LA, Izquierdo-de FM, Martinez-Brotons A, Sanchez-Gomez JM, Mascarell-Gregori B, Ruiz-Ros V, Cuenca-Romero I, et al., Medium-term results of cryoballoon ablation of the pulmonary veins in patients with paroxysmal and persistent atrial fibrillation. First experience of a Spanish center. J Interv Card Electrophysiol 2013; 37: 189-196.
-
(2013)
J Interv Card Electrophysiol
, vol.37
, pp. 189-196
-
-
Ferrero-De, L.A.1
Izquierdo-De, F.M.2
Martinez-Brotons, A.3
Sanchez-Gomez, J.M.4
Mascarell-Gregori, B.5
Ruiz-Ros, V.6
Cuenca-Romero, I.7
|