메뉴 건너뛰기




Volumn 24, Issue 5, 2013, Pages 492-497

Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon

Author keywords

atrial fibrillation; catheter ablation; cryoballoon; pulmonary vein isolation

Indexed keywords

AGED; ARTICLE; BALLOON CATHETER; CARDIOVASCULAR EQUIPMENT; CATHETER ABLATION; CLINICAL ARTICLE; CONTROLLED STUDY; CRYOBALLOON; FEMALE; FLUOROSCOPY; HEART ATRIUM FIBRILLATION; HUMAN; MALE; PAROXYSMAL HEART ATRIUM FIBRILLATION; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PULMONARY VEIN ISOLATION; SHORT LASTING PERSISTENT ATRIAL FIBRILLATION;

EID: 84876943025     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12082     Document Type: Article
Times cited : (176)

References (23)
  • 1
    • 34548803112 scopus 로고    scopus 로고
    • Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: Feasibility, complications, and short-term outcome
    • Van Belle Y, Janse P, Rivero-Ayerza MJ, Thornton AS, Jessurun ER, Theuns D, Jordaens L,: Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: Feasibility, complications, and short-term outcome. Eur Heart J 2007; 28: 2231-2237.
    • (2007) Eur Heart J , vol.28 , pp. 2231-2237
    • Van Belle, Y.1    Janse, P.2    Rivero-Ayerza, M.J.3    Thornton, A.S.4    Jessurun, E.R.5    Theuns, D.6    Jordaens, L.7
  • 4
    • 84876926041 scopus 로고    scopus 로고
    • Anatomical predictors for acute and mid-term success of cryoballoon ablation of atrial fibrillation using the 28 mm balloon
    • DOI: 10.1111/j.1540-8167.2012.12003.x
    • Knecht S, Kühne M, Altmann D, Ammann P, Schaer B, Osswald S, Sticherling C,: Anatomical predictors for acute and mid-term success of cryoballoon ablation of atrial fibrillation using the 28 mm balloon. J Cardiovasc Electrophysiol, DOI: 10.1111/j.1540-8167.2012.12003.x
    • J Cardiovasc Electrophysiol
    • Knecht, S.1    Kühne, M.2    Altmann, D.3    Ammann, P.4    Schaer, B.5    Osswald, S.6    Sticherling, C.7
  • 7
    • 74549172073 scopus 로고    scopus 로고
    • Pulmonary vein reconnection after cryoballoon ablation: Back to the drawing board
    • Liu CF,: Pulmonary vein reconnection after cryoballoon ablation: Back to the drawing board. Heart Rhythm 2010; 7: 191-192.
    • (2010) Heart Rhythm , vol.7 , pp. 191-192
    • Liu, C.F.1
  • 15
    • 77956111336 scopus 로고    scopus 로고
    • Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation
    • Kojodjojo P, O'Neill MD, Lim PB, Malcolm-Lawes L, Whinnett ZI, Salukhe TV, Linton NW, Lefroy D, Mason A, Wright I, Peters NS, Kanagaratnam P, Davies DW,: Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart 2010; 96: 1379-1384.
    • (2010) Heart , vol.96 , pp. 1379-1384
    • Kojodjojo, P.1    O'Neill, M.D.2    Lim, P.B.3    Malcolm-Lawes, L.4    Whinnett, Z.I.5    Salukhe, T.V.6    Linton, N.W.7    Lefroy, D.8    Mason, A.9    Wright, I.10    Peters, N.S.11    Kanagaratnam, P.12    Davies, D.W.13


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.