메뉴 건너뛰기




Volumn 44, Issue 2, 2016, Pages 233-235

Terminal decontamination of the Royal Free London's high-level isolation unit after a case of Ebola virus disease using hydrogen peroxide vapor

Author keywords

Contamination; Decontamination; Ebola; Hydrogen peroxide vapor

Indexed keywords

FORMALDEHYDE; HYDROGEN PEROXIDE;

EID: 84958850151     PISSN: 01966553     EISSN: 15273296     Source Type: Journal    
DOI: 10.1016/j.ajic.2015.08.025     Document Type: Article
Times cited : (22)

References (11)
  • 1
    • 84874247682 scopus 로고    scopus 로고
    • Viral haemorrhagic fevers in healthcare settings
    • L. Ftika, and H.C. Maltezou Viral haemorrhagic fevers in healthcare settings J Hosp Infect 83 2013 185 192
    • (2013) J Hosp Infect , vol.83 , pp. 185-192
    • Ftika, L.1    Maltezou, H.C.2
  • 2
    • 84937402293 scopus 로고    scopus 로고
    • Public Health England 21 August Accessed October 16, 2015
    • Public Health England. Ebola virus disease epidemiological update: 21 August 2015. Available from: https://www.gov.uk/government/publications/ebola-virus-disease-epidemiological-update#history. Accessed October 16, 2015.
    • (2015) Ebola Virus Disease Epidemiological Update
  • 3
    • 84958844565 scopus 로고    scopus 로고
    • Public Health England 20 October. Accessed October 16, 2015
    • Public Health England. Risk assessment of the Ebola outbreak in West Africa: UPDATED 20 October. Available from: https://www.gov.uk/government/publications/ebola-virus-disease-risk-assessment-of-outbreak-in-west-africa#history. Accessed October 16, 2015.
    • Risk Assessment of the Ebola Outbreak in West Africa: UPDATED
  • 4
    • 38449087271 scopus 로고    scopus 로고
    • Assessment of the risk of Ebola virus transmission from bodily fluids and fomites
    • D.G. Bausch, J.S. Towner, S.F. Dowell, F. Kaducu, M. Lukwiya, A. Sanchez, and et al. Assessment of the risk of Ebola virus transmission from bodily fluids and fomites J Infect Dis 196 Suppl 2007 S142 S147
    • (2007) J Infect Dis , vol.196 , pp. S142-S147
    • Bausch, D.G.1    Towner, J.S.2    Dowell, S.F.3    Kaducu, F.4    Lukwiya, M.5    Sanchez, A.6
  • 6
    • 78650440827 scopus 로고    scopus 로고
    • The survival of filoviruses in liquids, on solid substrates and in a dynamic aerosol
    • T.J. Piercy, S.J. Smither, J.A. Steward, L. Eastaugh, and M.S. Lever The survival of filoviruses in liquids, on solid substrates and in a dynamic aerosol J Appl Microbiol 109 2010 1531 1539
    • (2010) J Appl Microbiol , vol.109 , pp. 1531-1539
    • Piercy, T.J.1    Smither, S.J.2    Steward, J.A.3    Eastaugh, L.4    Lever, M.S.5
  • 8
    • 79958739691 scopus 로고    scopus 로고
    • The role played by contaminated surfaces in the transmission of nosocomial pathogens
    • J.A. Otter, S. Yezli, and G.L. French The role played by contaminated surfaces in the transmission of nosocomial pathogens Infect Control Hosp Epidemiol 32 2011 687 699
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 687-699
    • Otter, J.A.1    Yezli, S.2    French, G.L.3
  • 9
    • 84897563026 scopus 로고    scopus 로고
    • Evaluating the virucidal efficacy of hydrogen peroxide vapour
    • S.M. Goyal, Y. Chander, S. Yezli, and J.A. Otter Evaluating the virucidal efficacy of hydrogen peroxide vapour J Hosp Infect 86 2014 255 259
    • (2014) J Hosp Infect , vol.86 , pp. 255-259
    • Goyal, S.M.1    Chander, Y.2    Yezli, S.3    Otter, J.A.4
  • 10
    • 84871003763 scopus 로고    scopus 로고
    • Is there a role for "no-touch" automated room disinfection systems in infection prevention and control?
    • J.A. Otter, S. Yezli, T.M. Perl, F. Barbut, and G.L. French Is there a role for "no-touch" automated room disinfection systems in infection prevention and control? J Hosp Infect 83 2013 1 13
    • (2013) J Hosp Infect , vol.83 , pp. 1-13
    • Otter, J.A.1    Yezli, S.2    Perl, T.M.3    Barbut, F.4    French, G.L.5
  • 11
    • 77954536801 scopus 로고    scopus 로고
    • Hydrogen peroxide vapour decontamination of a critical care unit room used to treat a patient with Lassa fever
    • J.A. Otter, M. Barnicoat, J. Down, D. Smyth, S. Yezli, and A. Jeanes Hydrogen peroxide vapour decontamination of a critical care unit room used to treat a patient with Lassa fever J Hosp Infect 75 2010 335 337
    • (2010) J Hosp Infect , vol.75 , pp. 335-337
    • Otter, J.A.1    Barnicoat, M.2    Down, J.3    Smyth, D.4    Yezli, S.5    Jeanes, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.