메뉴 건너뛰기




Volumn 67, Issue 6, 2016, Pages 656-658

Shedding more light on valve thrombosis after transcatheter aortic valve replacement

Author keywords

aortic stenosis; structural valve deterioration; transcatheter aortic valve replacement

Indexed keywords

ANTICOAGULANT THERAPY; CARDIOVASCULAR RISK; DISEASE SURVEILLANCE; FOLLOW UP; FOUR DIMENSIONAL COMPUTED TOMOGRAPHY; HEART HEMODYNAMICS; HEART VALVE PROSTHESIS; HEMODYNAMIC PARAMETERS; HUMAN; MEDICAL DEVICE COMPLICATION; MEDICAL LITERATURE; NOTE; OUTCOME ASSESSMENT; PATIENT MONITORING; PRIORITY JOURNAL; PROSTHETIC VALVE THROMBOSIS; RISK ASSESSMENT; TIME SERIES ANALYSIS; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSVALVULAR MEAN GRADIENT; VALVE HEMODYNAMIC DETERIORATION; ADVERSE EFFECTS; AORTA VALVE; FEMALE; HEMODYNAMICS; MALE; PATHOPHYSIOLOGY; PHYSIOLOGY; POSTOPERATIVE COMPLICATIONS; REGISTER;

EID: 84958743383     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2015.11.046     Document Type: Editorial
Times cited : (6)

References (10)
  • 1
    • 84931566497 scopus 로고    scopus 로고
    • 5 year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): Randomized controlled trial
    • M.J. Mack, M.B. Leon, C.R. Smith, and et al. 5 year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): randomized controlled trial Lancet 385 2015 2477 2484
    • (2015) Lancet , vol.385 , pp. 2477-2484
    • Mack, M.J.1    Leon, M.B.2    Smith, C.R.3
  • 2
    • 84942409908 scopus 로고    scopus 로고
    • 2-year outcomes in patients undergoing surgical or self-expanding transcatheter aortic valve replacement
    • M.J. Reardon, D.H. Adams, and N.S. Kleiman 2-year outcomes in patients undergoing surgical or self-expanding transcatheter aortic valve replacement J Am Coll Cardiol 66 2015 113 121
    • (2015) J Am Coll Cardiol , vol.66 , pp. 113-121
    • Reardon, M.J.1    Adams, D.H.2    Kleiman, N.S.3
  • 3
    • 84947786845 scopus 로고    scopus 로고
    • Possible subclinical leaflet thrombosis in bioprosthetic aortic valves
    • R.R. Makkar, G. Fontana, H. Jilahawi, and et al. Possible subclinical leaflet thrombosis in bioprosthetic aortic valves N Engl J Med 373 2015 2015 2024
    • (2015) N Engl J Med , vol.373 , pp. 2015-2024
    • Makkar, R.R.1    Fontana, G.2    Jilahawi, H.3
  • 4
    • 84929145059 scopus 로고    scopus 로고
    • Thrombus formation following transcatheter aortic valve replacement
    • E. De Marchena, J. Mesa, S. Pomenti, and et al. Thrombus formation following transcatheter aortic valve replacement J Am Coll Cardiol Intv 8 2015 728 739
    • (2015) J Am Coll Cardiol Intv , vol.8 , pp. 728-739
    • De Marchena, E.1    Mesa, J.2    Pomenti, S.3
  • 5
    • 84937469143 scopus 로고    scopus 로고
    • Early aortic transcatheter heart valve thrombosis: Diagnostic value of contrast-enhanced multidetector computed tomography
    • T. Leetmaa, N.C. Hansson, J. Leipsic, and et al. Early aortic transcatheter heart valve thrombosis: diagnostic value of contrast-enhanced multidetector computed tomography Circ Cardiovasc Interv 8 2015 e001596
    • (2015) Circ Cardiovasc Interv , vol.8 , pp. e001596
    • Leetmaa, T.1    Hansson, N.C.2    Leipsic, J.3
  • 6
    • 84951116358 scopus 로고    scopus 로고
    • Bioprosthetic valve thrombosis versus structural failure: Clinical and echocardiographic predictors
    • A.C. Egbe, S.V. Pislaru, P.A. Pellikka, and et al. Bioprosthetic valve thrombosis versus structural failure: clinical and echocardiographic predictors J Am Coll Cardiol 66 2015 2285 2294
    • (2015) J Am Coll Cardiol , vol.66 , pp. 2285-2294
    • Egbe, A.C.1    Pislaru, S.V.2    Pellikka, P.A.3
  • 7
    • 84947790221 scopus 로고    scopus 로고
    • Reduced leaflet motion in bioprosthetic aortic valves: The FDA perspective
    • J.C. Laschinger, C. Wu, N.G. Ibrahim, and J.E. Shuren Reduced leaflet motion in bioprosthetic aortic valves: the FDA perspective N Engl J Med 373 2015 1996 1998
    • (2015) N Engl J Med , vol.373 , pp. 1996-1998
    • Laschinger, J.C.1    Wu, C.2    Ibrahim, N.G.3    Shuren, J.E.4
  • 8
    • 84947755849 scopus 로고    scopus 로고
    • Uncertainty and possible subclinical valve leaflet thrombosis
    • D.R. Holmes, and M.J. Mack Uncertainty and possible subclinical valve leaflet thrombosis N Engl J Med 373 2015 2080 2082
    • (2015) N Engl J Med , vol.373 , pp. 2080-2082
    • Holmes, D.R.1    Mack, M.J.2
  • 9
    • 84958182658 scopus 로고    scopus 로고
    • Echocardiographic evaluation of prosthetic heart valves
    • H. Mahjoub, P. Pibarot, and J.G. Dumesnil Echocardiographic evaluation of prosthetic heart valves Curr Cardiol Rep 17 2015 48
    • (2015) Curr Cardiol Rep , vol.17 , pp. 48
    • Mahjoub, H.1    Pibarot, P.2    Dumesnil, J.G.3
  • 10
    • 84958787293 scopus 로고    scopus 로고
    • Incidence, timing, and predictors of valve hemodynamic deterioration after transcatheter aortic valve replacement: Multicenter registry
    • M. Del Trigo, A.J. Muñoz-Garcia, H.C. Wijeysundera, and et al. Incidence, timing, and predictors of valve hemodynamic deterioration after transcatheter aortic valve replacement: multicenter registry J Am Coll Cardiol 67 2016 644 655
    • (2016) J Am Coll Cardiol , vol.67 , pp. 644-655
    • Del Trigo, M.1    Muñoz-Garcia, A.J.2    Wijeysundera, H.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.