메뉴 건너뛰기




Volumn 7, Issue , 2015, Pages S304-S316

Transthoracic needle biopsy of the lung

Author keywords

Computed tomography guided TTNA (CT guided TTNA); CT guided electromagnetic navigational TTNA; Image guided lung biopsy; Transthoracic needle aspiration (TTNA); Ultrasound guided TTNA (US guided TTNA)

Indexed keywords

ARTICLE; BLEEDING; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; ECHOGRAPHY; ELECTROMAGNETIC NAVIGATIONAL TRANSTHORACIC NEEDLE ASPIRATION; FLUOROSCOPY; HUMAN; LUNG BIOPSY; LUNG CANCER; LUNG LESION; PILOT STUDY; PNEUMOTHORAX; SAFETY; SENSITIVITY AND SPECIFICITY; THORAX DISEASE; TRANSTHORACIC BIOPSY;

EID: 84958656804     PISSN: 20721439     EISSN: 20776624     Source Type: Journal    
DOI: 10.3978/j.issn.2072-1439.2015.12.16     Document Type: Article
Times cited : (178)

References (92)
  • 1
    • 0000289384 scopus 로고
    • A new technique for transthoracic biopsy of lung changes
    • Nordenström B. A new technique for transthoracic biopsy of lung changes. Br J Radiol 1965;38:550-3.
    • (1965) Br J Radiol , vol.38 , pp. 550-553
    • Nordenström, B.1
  • 2
    • 0033050698 scopus 로고    scopus 로고
    • US guidance for thoracic biopsy: a valuable alternative to CT
    • Sheth S, Hamper UM, Stanley DB, et al. US guidance for thoracic biopsy: a valuable alternative to CT. Radiology 1999;210:721-6.
    • (1999) Radiology , vol.210 , pp. 721-726
    • Sheth, S.1    Hamper, U.M.2    Stanley, D.B.3
  • 3
  • 4
    • 0032845082 scopus 로고    scopus 로고
    • Transthoracic needle aspiration biopsy for the diagnosis of localised pulmonary lesions: a meta-analysis
    • Lacasse Y, Wong E, Guyatt GH, et al. Transthoracic needle aspiration biopsy for the diagnosis of localised pulmonary lesions: a meta-analysis. Thorax 1999;54:884-93.
    • (1999) Thorax , vol.54 , pp. 884-893
    • Lacasse, Y.1    Wong, E.2    Guyatt, G.H.3
  • 5
    • 84877665036 scopus 로고    scopus 로고
    • Establishing the diagnosis of lung cancer: Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines
    • Rivera MP, Mehta AC, Wahidi MM. Establishing the diagnosis of lung cancer: Diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest 2013;143:e142S-65S.
    • (2013) Chest , vol.143 , pp. e142S-e165S
    • Rivera, M.P.1    Mehta, A.C.2    Wahidi, M.M.3
  • 6
    • 0037246876 scopus 로고    scopus 로고
    • Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence
    • Schreiber G, McCrory DC. Performance characteristics of different modalities for diagnosis of suspected lung cancer: summary of published evidence. Chest 2003;123:115S-128S.
    • (2003) Chest , vol.123 , pp. 115S-128S
    • Schreiber, G.1    McCrory, D.C.2
  • 7
    • 34848874552 scopus 로고    scopus 로고
    • Initial diagnosis of lung cancer: ACCP evidence-based clinical practice guidelines (2nd ed)
    • Rivera MP, Mehta AC. Initial diagnosis of lung cancer: ACCP evidence-based clinical practice guidelines (2nd ed). Chest 2007;132:131S-148S.
    • (2007) Chest , vol.132 , pp. 131S-148S
    • Rivera, M.P.1    Mehta, A.C.2
  • 8
    • 84941253937 scopus 로고    scopus 로고
    • Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules
    • Arias S, Lee H, Semaan R, et al. Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules. J Vis Exp 2015;(99):e52723.
    • (2015) J Vis Exp , Issue.99
    • Arias, S.1    Lee, H.2    Semaan, R.3
  • 9
    • 84958596997 scopus 로고    scopus 로고
    • Thoracoscopic ultrasonography for localization of subcentimetre lung nodules
    • [Epub ahead of print]
    • Wada H, Anayama T, Hirohashi K, et al. Thoracoscopic ultrasonography for localization of subcentimetre lung nodules. Eur J Cardiothorac Surg 2015. [Epub ahead of print].
    • (2015) Eur J Cardiothorac Surg
    • Wada, H.1    Anayama, T.2    Hirohashi, K.3
  • 10
    • 84939884565 scopus 로고    scopus 로고
    • Diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy of solitary pulmonary nodules
    • Liu S, Li C, Yu X, et al. Diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy of solitary pulmonary nodules. Cardiovasc Intervent Radiol 2015;38:416-21.
    • (2015) Cardiovasc Intervent Radiol , vol.38 , pp. 416-421
    • Liu, S.1    Li, C.2    Yu, X.3
  • 11
    • 0031715084 scopus 로고    scopus 로고
    • Percutaneous transthoracic needle aspiration biopsy: a comprehensive review of its current role in the diagnosis and treatment of lung tumors
    • Larscheid RC, Thorpe PE, Scott WJ. Percutaneous transthoracic needle aspiration biopsy: a comprehensive review of its current role in the diagnosis and treatment of lung tumors. Chest 1998;114:704-9.
    • (1998) Chest , vol.114 , pp. 704-709
    • Larscheid, R.C.1    Thorpe, P.E.2    Scott, W.J.3
  • 12
    • 0035277521 scopus 로고    scopus 로고
    • CT-guided percutaneous core biopsies of pulmonary lesions. Diagnostic accuracy, complications and therapeutic impact
    • Lopez Hänninen E, Vogl TJ, Ricke J, et al. CT-guided percutaneous core biopsies of pulmonary lesions. Diagnostic accuracy, complications and therapeutic impact. Acta Radiol 2001;42:151-5.
    • (2001) Acta Radiol , vol.42 , pp. 151-155
    • Lopez Hänninen, E.1    Vogl, T.J.2    Ricke, J.3
  • 13
    • 0142241117 scopus 로고    scopus 로고
    • CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate
    • Geraghty PR, Kee ST, McFarlane G, et al. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003;229:475-81.
    • (2003) Radiology , vol.229 , pp. 475-481
    • Geraghty, P.R.1    Kee, S.T.2    McFarlane, G.3
  • 14
    • 0030937778 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy of small solitary pulmonary nodules
    • Yankelevitz DF, Henschke CI, Koizumi JH, et al. CT-guided transthoracic needle biopsy of small solitary pulmonary nodules. Clin Imaging 1997;21:107-10.
    • (1997) Clin Imaging , vol.21 , pp. 107-110
    • Yankelevitz, D.F.1    Henschke, C.I.2    Koizumi, J.H.3
  • 15
    • 0034522999 scopus 로고    scopus 로고
    • CT-guided cutting needle biopsy of lung lesions--safety and efficacy of an out-patient service
    • Charig MJ, Phillips AJ. CT-guided cutting needle biopsy of lung lesions--safety and efficacy of an out-patient service. Clin Radiol 2000;55:964-9.
    • (2000) Clin Radiol , vol.55 , pp. 964-969
    • Charig, M.J.1    Phillips, A.J.2
  • 16
    • 0033854427 scopus 로고    scopus 로고
    • Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules
    • Hirose T, Mori K, Machida S, et al. Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules. Jpn J Clin Oncol 2000;30:259-62.
    • (2000) Jpn J Clin Oncol , vol.30 , pp. 259-262
    • Hirose, T.1    Mori, K.2    Machida, S.3
  • 17
    • 0036328430 scopus 로고    scopus 로고
    • CT-guided transthoracic fine needle aspiration of pulmonary lesions: accuracy and complications in 294 patients
    • Arslan S, Yilmaz A, Bayramgürler B, et al. CT- guided transthoracic fine needle aspiration of pulmonary lesions: accuracy and complications in 294 patients. Med Sci Monit 2002;8:CR493-7.
    • (2002) Med Sci Monit , vol.8 , pp. CR493-CR497
    • Arslan, S.1    Yilmaz, A.2    Bayramgürler, B.3
  • 18
    • 0031866908 scopus 로고    scopus 로고
    • Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle
    • Lucidarme O, Howarth N, Finet JF, et al. Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle. Radiology 1998;207:759-65.
    • (1998) Radiology , vol.207 , pp. 759-765
    • Lucidarme, O.1    Howarth, N.2    Finet, J.F.3
  • 19
    • 0028504546 scopus 로고
    • Value of CT-guided fine needle aspiration in solitary pulmonary nodules with negative fiberoptic bronchoscopy
    • García Río F, Díaz Lobato S, Pino JM, et al. Value of CT-guided fine needle aspiration in solitary pulmonary nodules with negative fiberoptic bronchoscopy. Acta Radiol 1994;35:478-80.
    • (1994) Acta Radiol , vol.35 , pp. 478-480
    • García Río, F.1    Díaz Lobato, S.2    Pino, J.M.3
  • 20
    • 0036891927 scopus 로고    scopus 로고
    • CT-guided percutaneous fine-needle aspiration biopsy of small (< or =1-cm) pulmonary lesions
    • Wallace MJ, Krishnamurthy S, Broemeling LD, et al. CT-guided percutaneous fine-needle aspiration biopsy of small (< or =1-cm) pulmonary lesions. Radiology 2002;225:823-8.
    • (2002) Radiology , vol.225 , pp. 823-828
    • Wallace, M.J.1    Krishnamurthy, S.2    Broemeling, L.D.3
  • 21
    • 0034523283 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle
    • Laurent F, Latrabe V, Vergier B, et al. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 2000;55:281-7.
    • (2000) Clin Radiol , vol.55 , pp. 281-287
    • Laurent, F.1    Latrabe, V.2    Vergier, B.3
  • 22
    • 0038512071 scopus 로고    scopus 로고
    • CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules
    • Ohno Y, Hatabu H, Takenaka D, et al. CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 2003;180:1665-9.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 1665-1669
    • Ohno, Y.1    Hatabu, H.2    Takenaka, D.3
  • 23
    • 46849107727 scopus 로고    scopus 로고
    • Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates?
    • Heyer CM, Reichelt S, Peters SA, et al. Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates? Acad Radiol 2008;15:1017-26.
    • (2008) Acad Radiol , vol.15 , pp. 1017-1026
    • Heyer, C.M.1    Reichelt, S.2    Peters, S.A.3
  • 24
    • 3242763913 scopus 로고    scopus 로고
    • Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions
    • Montaudon M, Latrabe V, Pariente A, et al. Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions. Eur Radiol 2004;14:1234-40.
    • (2004) Eur Radiol , vol.14 , pp. 1234-1240
    • Montaudon, M.1    Latrabe, V.2    Pariente, A.3
  • 25
    • 0038476397 scopus 로고    scopus 로고
    • Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures
    • Yeow KM, Tsay PK, Cheung YC, et al. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol 2003;14:581-8.
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 581-588
    • Yeow, K.M.1    Tsay, P.K.2    Cheung, Y.C.3
  • 26
    • 38349048509 scopus 로고    scopus 로고
    • Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield
    • Priola AM, Priola SM, Cataldi A, et al. Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield. Radiol Med 2007;112:1142-59.
    • (2007) Radiol Med , vol.112 , pp. 1142-1159
    • Priola, A.M.1    Priola, S.M.2    Cataldi, A.3
  • 27
    • 33845987714 scopus 로고    scopus 로고
    • Additional value of CTfluoroscopic biopsy of pulmonary lesions: a retrospective study of 69 patients
    • Bladt O, De Wever W. Additional value of CTfluoroscopic biopsy of pulmonary lesions: a retrospective study of 69 patients. JBR-BTR 2006;89:298-302.
    • (2006) JBR-BTR , vol.89 , pp. 298-302
    • Bladt, O.1    De Wever, W.2
  • 28
    • 73149114866 scopus 로고    scopus 로고
    • CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure
    • Hiraki T, Mimura H, Gobara H, et al. CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 2009;136:1612-7.
    • (2009) Chest , vol.136 , pp. 1612-1617
    • Hiraki, T.1    Mimura, H.2    Gobara, H.3
  • 29
    • 84855567303 scopus 로고    scopus 로고
    • CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: diagnostic yield in 83 lesions
    • Inoue D, Gobara H, Hiraki T, et al. CT fluoroscopy-guided cutting needle biopsy of focal pure ground-glass opacity lung lesions: diagnostic yield in 83 lesions. Eur J Radiol 2012;81:354-9.
    • (2012) Eur J Radiol , vol.81 , pp. 354-359
    • Inoue, D.1    Gobara, H.2    Hiraki, T.3
  • 30
    • 63049105337 scopus 로고    scopus 로고
    • Diagnostic accuracy of CT fluoroscopy-guided needle aspiration biopsy of groundglass opacity pulmonary lesions
    • Hur J, Lee HJ, Nam JE, et al. Diagnostic accuracy of CT fluoroscopy-guided needle aspiration biopsy of groundglass opacity pulmonary lesions. AJR Am J Roentgenol 2009;192:629-34.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 629-634
    • Hur, J.1    Lee, H.J.2    Nam, J.E.3
  • 31
    • 80052172269 scopus 로고    scopus 로고
    • Diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity pulmonary lesions
    • Yamauchi Y, Izumi Y, Nakatsuka S, et al. Diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity pulmonary lesions. Eur J Radiol 2011;79:e85-9.
    • (2011) Eur J Radiol , vol.79 , pp. e85-e89
    • Yamauchi, Y.1    Izumi, Y.2    Nakatsuka, S.3
  • 32
    • 84873620946 scopus 로고    scopus 로고
    • Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions
    • 20120447
    • Yamagami T, Yoshimatsu R, Miura H, et al. Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions. Br J Radiol 2013;86:20120447.
    • (2013) Br J Radiol , vol.86
    • Yamagami, T.1    Yoshimatsu, R.2    Miura, H.3
  • 33
    • 4544348258 scopus 로고    scopus 로고
    • Percutaneous needle biopsy for small lung nodules beneath the rib under CT scan fluoroscopic guidance with gantry tilt
    • Yamagami T, Kato T, Iida S, et al. Percutaneous needle biopsy for small lung nodules beneath the rib under CT scan fluoroscopic guidance with gantry tilt. Chest 2004;126:744-7.
    • (2004) Chest , vol.126 , pp. 744-747
    • Yamagami, T.1    Kato, T.2    Iida, S.3
  • 34
    • 84938396439 scopus 로고    scopus 로고
    • Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules
    • Yang W, Sun W, Li Q, et al. Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules. PLoS One 2015;10:e0131373.
    • (2015) PLoS One , vol.10
    • Yang, W.1    Sun, W.2    Li, Q.3
  • 35
    • 84888007265 scopus 로고    scopus 로고
    • Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules
    • De Filippo M, Saba L, Concari G, et al. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules. Radiol Med 2013;118:1071-81.
    • (2013) Radiol Med , vol.118 , pp. 1071-1081
    • De Filippo, M.1    Saba, L.2    Concari, G.3
  • 36
    • 38949124072 scopus 로고    scopus 로고
    • CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less
    • Ng YL, Patsios D, Roberts H, et al. CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less. Clin Radiol 2008;63:272-7.
    • (2008) Clin Radiol , vol.63 , pp. 272-277
    • Ng, Y.L.1    Patsios, D.2    Roberts, H.3
  • 37
    • 84871716153 scopus 로고    scopus 로고
    • Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions
    • Zhuang YP, Wang HY, Zhang J, et al. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions. Eur J Radiol 2013;82:182-6.
    • (2013) Eur J Radiol , vol.82 , pp. 182-186
    • Zhuang, Y.P.1    Wang, H.Y.2    Zhang, J.3
  • 38
    • 37549057389 scopus 로고    scopus 로고
    • Diagnostic accuracy of CT-guided core biopsy of ground-glass opacity pulmonary lesions
    • Kim TJ, Lee JH, Lee CT, et al. Diagnostic accuracy of CT-guided core biopsy of ground-glass opacity pulmonary lesions. AJR Am J Roentgenol 2008;190:234-9.
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 234-239
    • Kim, T.J.1    Lee, J.H.2    Lee, C.T.3
  • 39
    • 84886478770 scopus 로고    scopus 로고
    • Percutaneous CT-guided aspiration and core biopsy of pulmonary nodules smaller than 1 cm: analysis of outcomes of 305 procedures from a tertiary referral center
    • Choi SH, Chae EJ, Kim JE, et al. Percutaneous CT-guided aspiration and core biopsy of pulmonary nodules smaller than 1 cm: analysis of outcomes of 305 procedures from a tertiary referral center. AJR Am J Roentgenol 2013;201:964-70.
    • (2013) AJR Am J Roentgenol , vol.201 , pp. 964-970
    • Choi, S.H.1    Chae, E.J.2    Kim, J.E.3
  • 40
    • 0031881698 scopus 로고    scopus 로고
    • CT-guided biopsy of pulmonary nodules less than 3 cm: usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis
    • Hayashi N, Sakai T, Kitagawa M, et al. CT-guided biopsy of pulmonary nodules less than 3 cm: usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis. AJR Am J Roentgenol 1998;170:329-31.
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 329-331
    • Hayashi, N.1    Sakai, T.2    Kitagawa, M.3
  • 41
    • 84871333095 scopus 로고    scopus 로고
    • CT-guided percutaneous core needle biopsy for small (=20 mm) pulmonary lesions
    • Li Y, Du Y, Yang HF, et al. CT-guided percutaneous core needle biopsy for small (=20 mm) pulmonary lesions. Clin Radiol 2013;68:e43-8.
    • (2013) Clin Radiol , vol.68 , pp. e43-e48
    • Li, Y.1    Du, Y.2    Yang, H.F.3
  • 42
    • 84896932247 scopus 로고    scopus 로고
    • C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients
    • Lee SM, Park CM, Lee KH, et al. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology 2014;271:291-300.
    • (2014) Radiology , vol.271 , pp. 291-300
    • Lee, S.M.1    Park, C.M.2    Lee, K.H.3
  • 43
    • 84865593706 scopus 로고    scopus 로고
    • C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (= 20 mm) lung nodules: diagnostic accuracy and complications in 161 patients
    • Choi JW, Park CM, Goo JM, et al. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (= 20 mm) lung nodules: diagnostic accuracy and complications in 161 patients. AJR Am J Roentgenol 2012;199:W322-30.
    • (2012) AJR Am J Roentgenol , vol.199 , pp. W322-W330
    • Choi, J.W.1    Park, C.M.2    Goo, J.M.3
  • 44
    • 84878586758 scopus 로고    scopus 로고
    • Percutaneous transthoracic needle biopsy of small (= 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance
    • Choo JY, Park CM, Lee NK, et al. Percutaneous transthoracic needle biopsy of small (= 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol 2013;23:712-9.
    • (2013) Eur Radiol , vol.23 , pp. 712-719
    • Choo, J.Y.1    Park, C.M.2    Lee, N.K.3
  • 45
    • 79955732499 scopus 로고    scopus 로고
    • Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions
    • Lima CD, Nunes RA, Saito EH, et al. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions. J Bras Pneumol 2011;37:209-16.
    • (2011) J Bras Pneumol , vol.37 , pp. 209-216
    • Lima, C.D.1    Nunes, R.A.2    Saito, E.H.3
  • 46
    • 0142157645 scopus 로고    scopus 로고
    • Head and neck cancer patients with pulmonary nodules: value and role of CT-guided transthoracic needle aspiration biopsies
    • Mesurolle B, Mignon F, Meingan P, et al. Head and neck cancer patients with pulmonary nodules: value and role of CT-guided transthoracic needle aspiration biopsies. Head Neck 2003;25:889-94.
    • (2003) Head Neck , vol.25 , pp. 889-894
    • Mesurolle, B.1    Mignon, F.2    Meingan, P.3
  • 47
    • 0031962493 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy following indeterminate fiberoptic bronchoscopy in solitary pulmonary nodules
    • Yankelevitz DF, Henschke CI, Koizumi J, et al. CT-guided transthoracic needle biopsy following indeterminate fiberoptic bronchoscopy in solitary pulmonary nodules. Clin Imaging 1998;22:7-10.
    • (1998) Clin Imaging , vol.22 , pp. 7-10
    • Yankelevitz, D.F.1    Henschke, C.I.2    Koizumi, J.3
  • 48
    • 0036369536 scopus 로고    scopus 로고
    • Computed tomography-guided cutting needle biopsy of pulmonary lesions
    • Yu LS, Deheinzelin D, Younes RN, et al. Computed tomography-guided cutting needle biopsy of pulmonary lesions. Rev Hosp Clin Fac Med Sao Paulo 2002;57:15-8.
    • (2002) Rev Hosp Clin Fac Med Sao Paulo , vol.57 , pp. 15-18
    • Yu, L.S.1    Deheinzelin, D.2    Younes, R.N.3
  • 49
    • 84922480482 scopus 로고    scopus 로고
    • C-arm conebeam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    • Floridi C, Muollo A, Fontana F, et al. C-arm conebeam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules. Radiol Med 2014;119:820-7.
    • (2014) Radiol Med , vol.119 , pp. 820-827
    • Floridi, C.1    Muollo, A.2    Fontana, F.3
  • 50
    • 84655162718 scopus 로고    scopus 로고
    • Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation
    • Lu CH, Hsiao CH, Chang YC, et al. Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation. J Thorac Oncol 2012;7:143-50.
    • (2012) J Thorac Oncol , vol.7 , pp. 143-150
    • Lu, C.H.1    Hsiao, C.H.2    Chang, Y.C.3
  • 51
    • 55649115272 scopus 로고    scopus 로고
    • Percutaneous CT-guided fine-needle aspiration of pulmonary lesions: Results and complications in 409 patients
    • Laspas F, Roussakis A, Efthimiadou R, et al. Percutaneous CT-guided fine-needle aspiration of pulmonary lesions: Results and complications in 409 patients. J Med Imaging Radiat Oncol 2008;52:458-62.
    • (2008) J Med Imaging Radiat Oncol , vol.52 , pp. 458-462
    • Laspas, F.1    Roussakis, A.2    Efthimiadou, R.3
  • 52
    • 84924930887 scopus 로고    scopus 로고
    • CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: a single-center experience with 750 biopsies in Japan
    • Takeshita J, Masago K, Kato R, et al. CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: a single-center experience with 750 biopsies in Japan. AJR Am J Roentgenol 2015;204:29-34.
    • (2015) AJR Am J Roentgenol , vol.204 , pp. 29-34
    • Takeshita, J.1    Masago, K.2    Kato, R.3
  • 53
    • 68249160786 scopus 로고    scopus 로고
    • CT-guided transthoracic fine needle aspiration of pulmonary lesions: accuracy and complications in 134 cases
    • Uskül BT, Türker H, Gökçe M, et al. CT-guided transthoracic fine needle aspiration of pulmonary lesions: accuracy and complications in 134 cases. Tuberk Toraks 2009;57:177-85.
    • (2009) Tuberk Toraks , vol.57 , pp. 177-185
    • Uskül, B.T.1    Türker, H.2    Gökçe, M.3
  • 54
    • 84921725779 scopus 로고    scopus 로고
    • CT-guided core needle biopsy of pleural lesions: evaluating diagnostic yield and associated complications
    • Niu XK, Bhetuwal A, Yang HF. CT-guided core needle biopsy of pleural lesions: evaluating diagnostic yield and associated complications. Korean J Radiol 2015;16:206-12.
    • (2015) Korean J Radiol , vol.16 , pp. 206-212
    • Niu, X.K.1    Bhetuwal, A.2    Yang, H.F.3
  • 55
    • 84879669197 scopus 로고    scopus 로고
    • CT-guided thoracic biopsy: evaluating diagnostic yield and complications
    • Loh SE, Wu DD, Venkatesh SK, et al. CT-guided thoracic biopsy: evaluating diagnostic yield and complications. Ann Acad Med Singapore 2013;42:285-90.
    • (2013) Ann Acad Med Singapore , vol.42 , pp. 285-290
    • Loh, S.E.1    Wu, D.D.2    Venkatesh, S.K.3
  • 56
    • 84861874380 scopus 로고    scopus 로고
    • Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications
    • Lee WJ, Chong S, Seo JS, et al. Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications. Br J Radiol 2012;85:e217-22.
    • (2012) Br J Radiol , vol.85 , pp. e217-e222
    • Lee, W.J.1    Chong, S.2    Seo, J.S.3
  • 57
    • 84943351906 scopus 로고    scopus 로고
    • A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety
    • Yaffe D, Koslow M, Haskiya H, et al. A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety. Eur Radiol 2015;25:3354-60.
    • (2015) Eur Radiol , vol.25 , pp. 3354-3360
    • Yaffe, D.1    Koslow, M.2    Haskiya, H.3
  • 58
    • 84908363004 scopus 로고    scopus 로고
    • Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions
    • Jiao de C, Li TF, Han XW, et al. Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions. Diagn Interv Radiol 2014;20:470-4.
    • (2014) Diagn Interv Radiol , vol.20 , pp. 470-474
    • Jiao de, C.1    Li, T.F.2    Han, X.W.3
  • 59
    • 79961037018 scopus 로고    scopus 로고
    • Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records
    • Wiener RS, Schwartz LM, Woloshin S, et al. Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records. Ann Intern Med 2011;155:137-44.
    • (2011) Ann Intern Med , vol.155 , pp. 137-144
    • Wiener, R.S.1    Schwartz, L.M.2    Woloshin, S.3
  • 60
    • 0030063957 scopus 로고    scopus 로고
    • Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    • Kazerooni EA, Lim FT, Mikhail A, et al. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 1996;198:371-5.
    • (1996) Radiology , vol.198 , pp. 371-375
    • Kazerooni, E.A.1    Lim, F.T.2    Mikhail, A.3
  • 61
    • 80054866470 scopus 로고    scopus 로고
    • Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung
    • Nakamura M, Yoshizako T, Koyama S, et al. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung. J Med Imaging Radiat Oncol 2011;55:474-8.
    • (2011) J Med Imaging Radiat Oncol , vol.55 , pp. 474-478
    • Nakamura, M.1    Yoshizako, T.2    Koyama, S.3
  • 62
    • 0032721261 scopus 로고    scopus 로고
    • Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors
    • Laurent F, Michel P, Latrabe V, et al. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors. AJR Am J Roentgenol 1999;172:1049-53.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 1049-1053
    • Laurent, F.1    Michel, P.2    Latrabe, V.3
  • 63
    • 0036247314 scopus 로고    scopus 로고
    • The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor
    • Saji H, Nakamura H, Tsuchida T, et al. The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor. Chest 2002;121:1521-6.
    • (2002) Chest , vol.121 , pp. 1521-1526
    • Saji, H.1    Nakamura, H.2    Tsuchida, T.3
  • 64
    • 0036212166 scopus 로고    scopus 로고
    • Management of pneumothorax after percutaneous CT-guided lung biopsy
    • Yamagami T, Nakamura T, Iida S, et al. Management of pneumothorax after percutaneous CT-guided lung biopsy. Chest 2002;121:1159-64.
    • (2002) Chest , vol.121 , pp. 1159-1164
    • Yamagami, T.1    Nakamura, T.2    Iida, S.3
  • 65
    • 0035167576 scopus 로고    scopus 로고
    • Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions
    • Yeow KM, See LC, Lui KW, et al. Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol 2001;12:1305-12.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1305-1312
    • Yeow, K.M.1    See, L.C.2    Lui, K.W.3
  • 66
    • 4544366568 scopus 로고    scopus 로고
    • Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies
    • Yeow KM, Su IH, Pan KT, et al. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 2004;126:748-54.
    • (2004) Chest , vol.126 , pp. 748-754
    • Yeow, K.M.1    Su, I.H.2    Pan, K.T.3
  • 67
    • 63649145063 scopus 로고    scopus 로고
    • CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications
    • Yildirim E, Kirbas I, Harman A, et al. CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications. Eur J Radiol 2009;70:57-60.
    • (2009) Eur J Radiol , vol.70 , pp. 57-60
    • Yildirim, E.1    Kirbas, I.2    Harman, A.3
  • 68
    • 45849132404 scopus 로고    scopus 로고
    • Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
    • Khan MF, Straub R, Moghaddam SR, et al. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy. Eur Radiol 2008;18:1356-63.
    • (2008) Eur Radiol , vol.18 , pp. 1356-1363
    • Khan, M.F.1    Straub, R.2    Moghaddam, S.R.3
  • 69
    • 84947472092 scopus 로고    scopus 로고
    • Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients
    • [Epub ahead of print]
    • Nour-Eldin NA, Alsubhi M, Emam A, et al. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients. Cardiovasc Intervent Radiol 2015. [Epub ahead of print].
    • (2015) Cardiovasc Intervent Radiol
    • Nour-Eldin, N.A.1    Alsubhi, M.2    Emam, A.3
  • 70
    • 0035086249 scopus 로고    scopus 로고
    • Transthoracic needle biopsy of the lung: results of early discharge in 506 outpatients
    • Dennie CJ, Matzinger FR, Marriner JR, et al. Transthoracic needle biopsy of the lung: results of early discharge in 506 outpatients. Radiology 2001;219:247-51.
    • (2001) Radiology , vol.219 , pp. 247-251
    • Dennie, C.J.1    Matzinger, F.R.2    Marriner, J.R.3
  • 71
    • 0026320314 scopus 로고
    • Complications after CT-guided needle biopsy through aerated versus nonaerated lung
    • Haramati LB, Austin JH. Complications after CT-guided needle biopsy through aerated versus nonaerated lung. Radiology 1991;181:778.
    • (1991) Radiology , vol.181 , pp. 778
    • Haramati, L.B.1    Austin, J.H.2
  • 72
    • 84947490491 scopus 로고    scopus 로고
    • The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy
    • Kuban JD, Tam AL, Huang SY, et al. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy. Cardiovasc Intervent Radiol 2015;38:1595-602.
    • (2015) Cardiovasc Intervent Radiol , vol.38 , pp. 1595-1602
    • Kuban, J.D.1    Tam, A.L.2    Huang, S.Y.3
  • 73
    • 84960469994 scopus 로고    scopus 로고
    • Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT
    • Chami HA, Faraj W, Yehia ZA, et al. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT. Clin Radiol 2015;70:1382-7.
    • (2015) Clin Radiol , vol.70 , pp. 1382-1387
    • Chami, H.A.1    Faraj, W.2    Yehia, Z.A.3
  • 74
    • 84938200552 scopus 로고    scopus 로고
    • Complications in CT-Guided, Semi-Automatic Coaxial Core Biopsy of Potentially Malignant Pulmonary Lesions
    • Schulze R, Seebacher G, Enderes B, et al. Complications in CT-Guided, Semi-Automatic Coaxial Core Biopsy of Potentially Malignant Pulmonary Lesions. Rofo 2015;187:697-702.
    • (2015) Rofo , vol.187 , pp. 697-702
    • Schulze, R.1    Seebacher, G.2    Enderes, B.3
  • 75
    • 84930477054 scopus 로고    scopus 로고
    • Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients
    • Kim JI, Park CM, Lee SM, et al. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients. Eur Radiol 2015;25:1845-53.
    • (2015) Eur Radiol , vol.25 , pp. 1845-1853
    • Kim, J.I.1    Park, C.M.2    Lee, S.M.3
  • 76
    • 33745223023 scopus 로고    scopus 로고
    • CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan
    • Tomiyama N, Yasuhara Y, Nakajima Y, et al. CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol 2006;59:60-4.
    • (2006) Eur J Radiol , vol.59 , pp. 60-64
    • Tomiyama, N.1    Yasuhara, Y.2    Nakajima, Y.3
  • 77
    • 0026632779 scopus 로고
    • Implantation metastasis of carcinoma after percutaneous fine-needle aspiration biopsy
    • Voravud N, Shin DM, Dekmezian RH, et al. Implantation metastasis of carcinoma after percutaneous fine-needle aspiration biopsy. Chest 1992;102:313-5.
    • (1992) Chest , vol.102 , pp. 313-315
    • Voravud, N.1    Shin, D.M.2    Dekmezian, R.H.3
  • 78
    • 0022884824 scopus 로고
    • Seeding of malignant cells into the needle track after lung and pleural biopsy
    • Müller NL, Bergin CJ, Miller RR, et al. Seeding of malignant cells into the needle track after lung and pleural biopsy. Can Assoc Radiol J 1986;37:192-4.
    • (1986) Can Assoc Radiol J , vol.37 , pp. 192-194
    • Müller, N.L.1    Bergin, C.J.2    Miller, R.R.3
  • 79
    • 79959364448 scopus 로고    scopus 로고
    • Systemic air embolism after transthoracic lung biopsy: A case report and review of literature
    • Bou-Assaly W, Pernicano P, Hoeffner E. Systemic air embolism after transthoracic lung biopsy: A case report and review of literature. World J Radiol 2010;2:193-6.
    • (2010) World J Radiol , vol.2 , pp. 193-196
    • Bou-Assaly, W.1    Pernicano, P.2    Hoeffner, E.3
  • 80
    • 0030137983 scopus 로고    scopus 로고
    • Ultrasonographically guided fine-needle aspiration biopsy of intrathoracic tumors
    • Knudsen DU, Nielsen SM, Hariri J, et al. Ultrasonographically guided fine-needle aspiration biopsy of intrathoracic tumors. Acta Radiol 1996;37:327-31.
    • (1996) Acta Radiol , vol.37 , pp. 327-331
    • Knudsen, D.U.1    Nielsen, S.M.2    Hariri, J.3
  • 81
    • 0027245965 scopus 로고
    • Peripheral pulmonary lesions: ultrasonic features and ultrasonically guided fine needle aspiration biopsy
    • Targhetta R, Bourgeois JM, Marty-Double C, et al. Peripheral pulmonary lesions: ultrasonic features and ultrasonically guided fine needle aspiration biopsy. J Ultrasound Med 1993;12:369-74.
    • (1993) J Ultrasound Med , vol.12 , pp. 369-374
    • Targhetta, R.1    Bourgeois, J.M.2    Marty-Double, C.3
  • 82
    • 0026548572 scopus 로고
    • Ultrasound-guided aspiration biopsy of small peripheral pulmonary nodules
    • Yuan A, Yang PC, Chang DB, et al. Ultrasound-guided aspiration biopsy of small peripheral pulmonary nodules. Chest 1992;101:926-30.
    • (1992) Chest , vol.101 , pp. 926-930
    • Yuan, A.1    Yang, P.C.2    Chang, D.B.3
  • 83
    • 0021835805 scopus 로고
    • Peripheral pulmonary lesions: ultrasonography and ultrasonically guided aspiration biopsy
    • Yang PC, Luh KT, Sheu JC, et al. Peripheral pulmonary lesions: ultrasonography and ultrasonically guided aspiration biopsy. Radiology 1985;155:451-6.
    • (1985) Radiology , vol.155 , pp. 451-456
    • Yang, P.C.1    Luh, K.T.2    Sheu, J.C.3
  • 84
    • 0028808786 scopus 로고
    • Ultrasound-guided fine-needle aspiration biopsy of solitary pulmonary nodules
    • Chen CC, Hsu WH, Huang CM, et al. Ultrasound-guided fine-needle aspiration biopsy of solitary pulmonary nodules. J Clin Ultrasound 1995;23:531-6.
    • (1995) J Clin Ultrasound , vol.23 , pp. 531-536
    • Chen, C.C.1    Hsu, W.H.2    Huang, C.M.3
  • 85
    • 28144435905 scopus 로고    scopus 로고
    • Ultrasound-guided fine needle aspiration biopsy of small pulmonary nodules abutting to the chest wall
    • Chen CC, Hsu WH, Huang CM, et al. Ultrasound-guided fine needle aspiration biopsy of small pulmonary nodules abutting to the chest wall. Zhonghua Yi Xue Za Zhi (Taipei) 1996;57:106-11.
    • (1996) Zhonghua Yi Xue Za Zhi (Taipei) , vol.57 , pp. 106-111
    • Chen, C.C.1    Hsu, W.H.2    Huang, C.M.3
  • 86
    • 0032916969 scopus 로고    scopus 로고
    • Ultrasound-guided percutaneous needle aspiration biopsy of peripheral pulmonary lesions
    • Dallari R, Gollini C, Barozzi G, et al. Ultrasound-guided percutaneous needle aspiration biopsy of peripheral pulmonary lesions. Monaldi Arch Chest Dis 1999;54:7-10.
    • (1999) Monaldi Arch Chest Dis , vol.54 , pp. 7-10
    • Dallari, R.1    Gollini, C.2    Barozzi, G.3
  • 87
    • 68049100299 scopus 로고    scopus 로고
    • Ultrasound-guided fine needle aspiration biopsy of pleural-based intrathoracic lesions
    • Khosla R, Rohatgi PK, Seam N. Ultrasound-guided fine needle aspiration biopsy of pleural-based intrathoracic lesions. J Bronchology Interv Pulmonol 2009;16:87-90.
    • (2009) J Bronchology Interv Pulmonol , vol.16 , pp. 87-90
    • Khosla, R.1    Rohatgi, P.K.2    Seam, N.3
  • 88
    • 0027700243 scopus 로고
    • Apical malignancies diagnosed by ultrasound-guided fine needle aspiration biopsy
    • Hsu WH, Chiang CD, Wang RC, et al. Apical malignancies diagnosed by ultrasound-guided fine needle aspiration biopsy. J Formos Med Assoc 1993;92:983-7.
    • (1993) J Formos Med Assoc , vol.92 , pp. 983-987
    • Hsu, W.H.1    Chiang, C.D.2    Wang, R.C.3
  • 89
    • 84937807062 scopus 로고    scopus 로고
    • Ultrasound-guided percutaneous needle aspiration by pulmonologists: a study of factors with impact on procedural yield and complications
    • Meena N, Bartter T. Ultrasound-guided percutaneous needle aspiration by pulmonologists: a study of factors with impact on procedural yield and complications. J Bronchology Interv Pulmonol 2015;22:204-8.
    • (2015) J Bronchology Interv Pulmonol , vol.22 , pp. 204-208
    • Meena, N.1    Bartter, T.2
  • 90
    • 84874327053 scopus 로고    scopus 로고
    • Pleural and peripheral lung lesions: comparison of US- and CT-guided biopsy
    • Sconfienza LM, Mauri G, Grossi F, et al. Pleural and peripheral lung lesions: comparison of US- and CT-guided biopsy. Radiology 2013;266:930-5.
    • (2013) Radiology , vol.266 , pp. 930-935
    • Sconfienza, L.M.1    Mauri, G.2    Grossi, F.3
  • 91
    • 84958622893 scopus 로고    scopus 로고
    • Combined Navigational Transthoracic Needle Aspiration and Bronchoscopy for the Diagnosis of Peripheral Pulmonary Nodule: A prospective Human Study
    • Montreal, QC
    • Yarmus L, Semaan R, Arias S, et al. Combined Navigational Transthoracic Needle Aspiration and Bronchoscopy for the Diagnosis of Peripheral Pulmonary Nodule: A prospective Human Study. CHEST, Interventional Pulmonary Posters. 2015, Montreal, QC. Available online: http://journal.publications.chestnet.org/article.aspx?articleid=2456700&resultClick=3
    • (2015) CHEST, Interventional Pulmonary Posters
    • Yarmus, L.1    Semaan, R.2    Arias, S.3
  • 92
    • 84988813534 scopus 로고    scopus 로고
    • Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions: Results of the AQuIRE Registry
    • [Epub ahead of print]
    • Ost DE, Ernst A, Lei X, et al. Diagnostic Yield and Complications of Bronchoscopy for Peripheral Lung Lesions: Results of the AQuIRE Registry. Am J Respir Crit Care Med 2015. [Epub ahead of print].
    • (2015) Am J Respir Crit Care Med
    • Ost, D.E.1    Ernst, A.2    Lei, X.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.