메뉴 건너뛰기




Volumn 271, Issue 1, 2014, Pages 291-300

C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: Clinical experience in 1108 patients

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ADVERSE OUTCOME; AGED; ARTICLE; BENIGN TUMOR; CHILD; CONE BEAM COMPUTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; FALSE NEGATIVE RESULT; FEMALE; HEMOPTYSIS; HUMAN; HUMAN TISSUE; LUNG BIOPSY; LUNG CANCER; LUNG NODULE; MAJOR CLINICAL STUDY; MALE; NEEDLE; PERCUTANEOUS BIOPSY; PNEUMOTHORAX; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; RETROSPECTIVE STUDY; RISK FACTOR; SCHOOL CHILD; SENSITIVITY AND SPECIFICITY; TRANSTHORACIC BIOPSY; TUMOR VOLUME; VERY ELDERLY; ADOLESCENT; DEVICES; INTERVENTIONAL RADIOLOGY; LUNG TUMOR; MIDDLE AGED; NEEDLE BIOPSY; PATHOLOGY; PROCEDURES; RADIOGRAPHY;

EID: 84896932247     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.13131265     Document Type: Article
Times cited : (179)

References (29)
  • 2
    • 0142241117 scopus 로고    scopus 로고
    • CT-guided Transthoracic Needle Aspiration Biopsy of Pulmonary Nodules: Needle Size and Pneumothorax Rate
    • DOI 10.1148/radiol.2291020499
    • Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003;229(2):475-481. (Pubitemid 37310835)
    • (2003) Radiology , vol.229 , Issue.2 , pp. 475-481
    • Geraghty, P.R.1    Kee, S.T.2    McFarlane, G.3    Razavi, M.K.4    Sze, D.Y.5    Dake, M.D.6
  • 3
    • 73149114866 scopus 로고    scopus 로고
    • CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: Diagnostic yield and risk factors for diagnostic failure
    • Hiraki T, Mimura H, Gobara H, et al. CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 2009;136(6):1612-1617.
    • (2009) Chest , vol.136 , Issue.6 , pp. 1612-1617
    • Hiraki, T.1    Mimura, H.2    Gobara, H.3
  • 4
    • 27144540098 scopus 로고    scopus 로고
    • CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: A prospective randomized controlled clinical trial
    • DOI 10.1148/radiol.2372041323
    • Carlson SK, Felmlee JP, Bender CE, et al. CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective ranpartial domized controlled clinical trial. Radiology 2005;237(2):701-708. (Pubitemid 41507915)
    • (2005) Radiology , vol.237 , Issue.2 , pp. 701-708
    • Carlson, S.K.1    Felmlee, J.P.2    Bender, C.E.3    Ehman, R.L.4    Classic, K.L.5    Hoskin, T.L.6    Harmsen, W.S.7    Hu, H.H.8
  • 6
    • 4544348258 scopus 로고    scopus 로고
    • Percutaneous needle biopsy for small lung nodules beneath the rib under CT scan fluoroscopic guidance with gantry tilt
    • DOI 10.1378/chest.126.3.744
    • Yamagami T, Kato T, Iida S, Hirota T, Nishimura T. Percutaneous needle biopsy for small lung nodules beneath the rib under CT scan fluoroscopic guidance with gantry tilt. Chest 2004;126(3):744-747. (Pubitemid 39258026)
    • (2004) Chest , vol.126 , Issue.3 , pp. 744-747
    • Yamagami, T.1    Kato, T.2    Iida, S.3    Hirota, T.4    Nishimura, T.5
  • 7
    • 84897005206 scopus 로고    scopus 로고
    • Interventions using C-arm computed tomography
    • Mahnken AH, Ricke J, eds. Heidelberg, Germany: Springer
    • Wacker FK, Meyer B. Interventions using C-arm computed tomography. In: Mahnken AH, Ricke J, eds. CT- and MR-guided interventions in radiology. Heidelberg, Germany: Springer, 2008; 370-381.
    • (2008) CT- and MR-guided Interventions in Radiology , pp. 370-381
    • Wacker, F.K.1    Meyer, B.2
  • 8
    • 79951954625 scopus 로고    scopus 로고
    • CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: A prospective controlled study to assess radiation doses and diagnostic performance
    • Kim GR, Hur J, Lee SM, et al. CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 2011;21(2):232-239.
    • (2011) Eur Radiol , vol.21 , Issue.2 , pp. 232-239
    • Kim, G.R.1    Hur, J.2    Lee, S.M.3
  • 9
    • 77957941551 scopus 로고    scopus 로고
    • Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems
    • Jin KN, Park CM, Goo JM, et al. Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems. Eur Radiol 2010;20(9):2108-2115.
    • (2010) Eur Radiol , vol.20 , Issue.9 , pp. 2108-2115
    • Jin, K.N.1    Park, C.M.2    Goo, J.M.3
  • 10
    • 35349003753 scopus 로고    scopus 로고
    • Flat-detector computed tomography (FD-CT)
    • DOI 10.1007/s00330-007-0651-9
    • Kalender WA, Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol 2007;17(11):2767-2779. (Pubitemid 47603972)
    • (2007) European Radiology , vol.17 , Issue.11 , pp. 2767-2779
    • Kalender, W.A.1    Kyriakou, Y.2
  • 11
    • 58149396296 scopus 로고    scopus 로고
    • Flat-panel volume CT: Fundamental principles, technology, and applications
    • Gupta R, Cheung AC, Bartling SH, et al. Flat-panel volume CT: fundamental principles, technology, and applications. Radio-Graphics 2008;28(7):2009-2022.
    • (2008) Radio-Graphics , vol.28 , Issue.7 , pp. 2009-2022
    • Gupta, R.1    Cheung, A.C.2    Bartling, S.H.3
  • 12
    • 67649990840 scopus 로고    scopus 로고
    • Three-dimensional C-arm cone-beam CT: Applications in the interventional suite
    • Wallace MJ, Kuo MD, Glaiberman C, et al. Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol 2009;20(7 Suppl):S523-S537.
    • (2009) J Vasc Interv Radiol , vol.20 , Issue.7 SUPPL.
    • Wallace, M.J.1    Kuo, M.D.2    Glaiberman, C.3
  • 13
    • 78649742498 scopus 로고    scopus 로고
    • C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: Usefulness in evaluation of small pulmonary nodules
    • Hwang HS, Chung MJ, Lee JW, Shin SW, Lee KS. C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules. AJR Am J Roentgenol 2010;195(6):W400-W407.
    • (2010) AJR Am J Roentgenol , vol.195 , Issue.6
    • Hwang, H.S.1    Chung, M.J.2    Lee, J.W.3    Shin, S.W.4    Lee, K.S.5
  • 14
    • 84865593706 scopus 로고    scopus 로고
    • C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤ 20 mm) lung nodules: Diagnostic accuracy and complications in 161 patients
    • Choi JW, Park CM, Goo JM, et al. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤ 20 mm) lung nodules: diagnostic accuracy and complications in 161 patients. AJR Am J Roentgenol 2012;199(3):W322-W330.
    • (2012) AJR Am J Roentgenol , vol.199 , Issue.3
    • Choi, J.W.1    Park, C.M.2    Goo, J.M.3
  • 15
    • 84878586758 scopus 로고    scopus 로고
    • Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance
    • Choo JY, Park CM, Lee NK, Lee SM, Lee HJ, Goo JM. Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance. Eur Radiol 2013;23(3):712-719.
    • (2013) Eur Radiol , vol.23 , Issue.3 , pp. 712-719
    • Choo, J.Y.1    Park, C.M.2    Lee, N.K.3    Lee, S.M.4    Lee, H.J.5    Goo, J.M.6
  • 16
    • 84861849316 scopus 로고    scopus 로고
    • Transthoracic needle biopsy using a C-arm cone-beam CT system: Diagnostic accuracy and safety
    • Choi MJ, Kim Y, Hong YS, Shim SS, Lim SM, Lee JK. Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety. Br J Radiol 2012;85(1014):e182-e187.
    • (2012) Br J Radiol , vol.85 , Issue.1014
    • Choi, M.J.1    Kim, Y.2    Hong, Y.S.3    Shim, S.S.4    Lim, S.M.5    Lee, J.K.6
  • 17
    • 84878115250 scopus 로고    scopus 로고
    • Pulmonary masses: Initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy
    • Braak SJ, Herder GJ, van Heesewijk JP, van Strijen MJ. Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol 2012;35(6):1414-1421.
    • (2012) Cardiovasc Intervent Radiol , vol.35 , Issue.6 , pp. 1414-1421
    • Braak, S.J.1    Herder, G.J.2    Van Heesewijk, J.P.3    Van Strijen, M.J.4
  • 18
    • 84861874380 scopus 로고    scopus 로고
    • Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: Diagnostic accuracy and postprocedural complications
    • Lee WJ, Chong S, Seo JS, Shim HJ. Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and postprocedural complications. Br J Radiol 2012;85(1014):e217-e222.
    • (2012) Br J Radiol , vol.85 , Issue.1014
    • Lee, W.J.1    Chong, S.2    Seo, J.S.3    Shim, H.J.4
  • 19
    • 84455206462 scopus 로고    scopus 로고
    • Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: Effect on pneumothorax rate
    • O'Neill AC, McCarthy C, Ridge CA, et al. Rapid needle-out patient-rollover time after percutaneous CT-guided transthoracic biopsy of lung nodules: effect on pneumothorax rate. Radiology 2012;262(1):314-319.
    • (2012) Radiology , vol.262 , Issue.1 , pp. 314-319
    • O'Neill, A.C.1    McCarthy, C.2    Ridge, C.A.3
  • 20
    • 77950433461 scopus 로고    scopus 로고
    • Transient part-solid nodules detected at screening thin-section CT for lung cancer: Comparison with persistent part-solid nodules
    • Lee SM, Park CM, Goo JM, et al. Transient part-solid nodules detected at screening thin-section CT for lung cancer: comparison with persistent part-solid nodules. Radiology 2010;255(1):242-251.
    • (2010) Radiology , vol.255 , Issue.1 , pp. 242-251
    • Lee, S.M.1    Park, C.M.2    Goo, J.M.3
  • 21
    • 0000117315 scopus 로고    scopus 로고
    • Assessing the fit of the model
    • 2nd ed. New York, NY: Wiley
    • Hosmer DW, Lemeshow S. Assessing the fit of the model. In: Applied logistic regression. 2nd ed. New York, NY: Wiley, 2000;143-202.
    • (2000) Applied Logistic Regression , pp. 143-202
    • Hosmer, D.W.1    Lemeshow, S.2
  • 22
    • 33744804307 scopus 로고    scopus 로고
    • Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses
    • DOI 10.1007/s00330-006-0152-2
    • Heck SL, Blom P, Berstad A. Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses. Eur Radiol 2006;16(6):1387-1392. (Pubitemid 43834727)
    • (2006) European Radiology , vol.16 , Issue.6 , pp. 1387-1392
    • Heck, S.L.1    Blom, P.2    Berstad, A.3
  • 23
    • 77749298656 scopus 로고    scopus 로고
    • Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: Retrospective analysis of the procedures conducted over a 9-year period
    • Hiraki T, Mimura H, Gobara H, et al. Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period. AJR Am J Roentgenol 2010;194(3):809-814.
    • (2010) AJR Am J Roentgenol , vol.194 , Issue.3 , pp. 809-814
    • Hiraki, T.1    Mimura, H.2    Gobara, H.3
  • 24
    • 4544366568 scopus 로고    scopus 로고
    • Risk factors of pneumothorax and bleeding: Multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies
    • Yeow KM, Su IH, Pan KT, et al. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 2004;126(3):748-754.
    • (2004) Chest , vol.126 , Issue.3 , pp. 748-754
    • Yeow, K.M.1    Su, I.H.2    Pan, K.T.3
  • 25
    • 0030063957 scopus 로고    scopus 로고
    • Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung
    • Kazerooni EA, Lim FT, Mikhail A, Martinez FJ. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung. Radiology 1996;198(2):371-375. (Pubitemid 26036839)
    • (1996) Radiology , vol.198 , Issue.2 , pp. 371-375
    • Kazerooni, E.A.1    Lim, F.T.2    Mikhail, A.3    Martinez, F.J.4
  • 26
    • 0035167576 scopus 로고    scopus 로고
    • Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions
    • Yeow KM, See LC, Lui KW, et al. Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions. J Vasc Interv Radiol 2001;12(11):1305-1312.
    • (2001) J Vasc Interv Radiol , vol.12 , Issue.11 , pp. 1305-1312
    • Yeow, K.M.1    See, L.C.2    Lui, K.W.3
  • 27
    • 0033041451 scopus 로고    scopus 로고
    • Transthoracic needle aspiration biopsy: Variables that affect risk of pneumothorax
    • Cox JE, Chiles C, McManus CM, Aquino SL, Choplin RH. Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax. Radiology 1999;212(1):165-168. (Pubitemid 29302530)
    • (1999) Radiology , vol.212 , Issue.1 , pp. 165-168
    • Cox, J.E.1    Chiles, C.2    McManus, C.M.3    Aquino, S.L.4    Choplin, R.H.5
  • 28
    • 0036247314 scopus 로고    scopus 로고
    • The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: The angle of the needle trajectory is a novel predictor
    • DOI 10.1378/chest.121.5.1521
    • Saji H, Nakamura H, Tsuchida T, et al. The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor. Chest 2002;121(5):1521-1526. (Pubitemid 34499665)
    • (2002) Chest , vol.121 , Issue.5 , pp. 1521-1526
    • Saji, H.1    Nakamura, H.2    Tsuchida, T.3    Tsuboi, M.4    Kawate, N.5    Konaka, C.6    Kato, H.7
  • 29
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: A catalog
    • Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 2008;248(1):254-263.
    • (2008) Radiology , vol.248 , Issue.1 , pp. 254-263
    • Mettler Jr., F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.