메뉴 건너뛰기




Volumn 74, Issue , 2015, Pages S30-S32

Reducing postoperative infections and red breast syndrome in patients with acellular dermalmatrix-based breast reconstruction: The relative roles of product sterility and lower body mass index

Author keywords

Acellular dermal matrix; Acellular dermis; AlloDerm; Red breast syndrome

Indexed keywords

COLLAGEN; SURGICAL MESH;

EID: 84955602129     PISSN: 01487043     EISSN: 15363708     Source Type: Journal    
DOI: 10.1097/SAP.0000000000000475     Document Type: Article
Times cited : (31)

References (18)
  • 1
    • 79958038180 scopus 로고    scopus 로고
    • Tissue expander breast reconstruction using prehydrated human acellular dermis
    • Rawlani V, Buck DW 2nd, Johnson SA, et al. Tissue expander breast reconstruction using prehydrated human acellular dermis. Ann Plast Surg. 2011;66: 593-597.
    • (2011) Ann Plast Surg , vol.66 , pp. 593-597
    • Rawlani, V.1    Buck, D.W.2    Johnson, S.A.3
  • 2
    • 84877845334 scopus 로고    scopus 로고
    • Resistance of acellular dermal matrix materials to microbial penetration
    • Fahrenbach EN, Qi C, Ibrahim O, et al. Resistance of acellular dermal matrix materials to microbial penetration. JAMA Dermatol. 2013;149:571-575.
    • (2013) JAMA Dermatol , vol.149 , pp. 571-575
    • Fahrenbach, E.N.1    Qi, C.2    Ibrahim, O.3
  • 3
    • 67749119909 scopus 로고    scopus 로고
    • Early results using sterilized acellular human dermis (Neoform) in postmastectomy tissue expander breast reconstruction
    • Losken A. Early results using sterilized acellular human dermis (Neoform) in postmastectomy tissue expander breast reconstruction. Plast Reconstr Surg. 2009;123:1654-1658.
    • (2009) Plast Reconstr Surg , vol.123 , pp. 1654-1658
    • Losken, A.1
  • 4
    • 84885474680 scopus 로고    scopus 로고
    • Sterile "ready-to-use" AlloDerm decreases postoperative infectious complications in patients undergoing immediate implant-based breast reconstruction with acellular dermal matrix
    • Weichman KE, Wilson SC, Saadeh PB, et al. Sterile "ready-to-use" AlloDerm decreases postoperative infectious complications in patients undergoing immediate implant-based breast reconstruction with acellular dermal matrix. Plast Reconstr Surg. 2013;132:725-736.
    • (2013) Plast Reconstr Surg , vol.132 , pp. 725-736
    • Weichman, K.E.1    Wilson, S.C.2    Saadeh, P.B.3
  • 5
    • 79952485599 scopus 로고    scopus 로고
    • The true incidence of near-term postoperative complications in prosthetic breast reconstruction utilizing human acellular dermal matrices: A meta-analysis
    • Newman MI, Swartz KA, Samson MC, et al. The true incidence of near-term postoperative complications in prosthetic breast reconstruction utilizing human acellular dermal matrices: a meta-analysis. Aesthet Plast Surg. 2011;35:100-106.
    • (2011) Aesthet Plast Surg , vol.35 , pp. 100-106
    • Newman, M.I.1    Swartz, K.A.2    Samson, M.C.3
  • 7
    • 64149113304 scopus 로고    scopus 로고
    • Hydrated vs. Freeze-dried human acellular dermal matrix for hernia repair: A comparison in a rabbit model
    • Roth JS, Dexter DD, Lumpkins K, et al. Hydrated vs. freeze-dried human acellular dermal matrix for hernia repair: a comparison in a rabbit model. Hernia. 2009;13:201-207.
    • (2009) Hernia , vol.13 , pp. 201-207
    • Roth, J.S.1    Dexter, D.D.2    Lumpkins, K.3
  • 8
    • 84872064852 scopus 로고    scopus 로고
    • Evaluating sterile human acellular dermal matrix in immediate expander-based breast reconstruction: A multicenter, prospective, cohort study
    • Venturi ML, Mesbahi AN, Boehmler JH IV, et al. Evaluating sterile human acellular dermal matrix in immediate expander-based breast reconstruction: A multicenter, prospective, cohort study. Plast Reconstr Surg. 2013;131:9e-18e.
    • (2013) Plast Reconstr Surg , vol.131 , pp. 9e-18e
    • Venturi, M.L.1    Mesbahi, A.N.2    Boehmler, J.H.I.V.3
  • 9
    • 85027923720 scopus 로고    scopus 로고
    • Delayed hypersensitivity reaction to acellular dermal matrix in breast reconstruction: The red breast syndrome?
    • Ganske I, Hoyler M, Fox SE, et al. Delayed hypersensitivity reaction to acellular dermal matrix in breast reconstruction: the red breast syndrome? Ann Plast Surg. 2014;73:S139-S143.
    • (2014) Ann Plast Surg , vol.73 , pp. S139-S143
    • Ganske, I.1    Hoyler, M.2    Fox, S.E.3
  • 10
    • 77956472807 scopus 로고    scopus 로고
    • AlloDerm performance in the setting of prosthetic breast surgery, infection, and irradiation
    • author reply 1120-1121
    • Newman MI, Hanabergh E, Samson MC. AlloDerm performance in the setting of prosthetic breast surgery, infection, and irradiation. Plast Reconstr Surg. 2010;126:1120 author reply 1120-1121.
    • (2010) Plast Reconstr Surg , vol.126 , pp. 1120
    • Newman, M.I.1    Hanabergh, E.2    Samson, M.C.3
  • 11
    • 76949095910 scopus 로고    scopus 로고
    • Reversed acellular dermis: Failure of graft incorporation in primary tissue expander breast reconstruction resulting in recurrent breast cellulitis
    • Heyer K, Buck DW 2nd, Kato C, et al. Reversed acellular dermis: failure of graft incorporation in primary tissue expander breast reconstruction resulting in recurrent breast cellulitis. Plast Reconstr Surg. 2010;125:66e-68e.
    • (2010) Plast Reconstr Surg , vol.125 , pp. 66e-68e
    • Heyer, K.1    Buck, D.W.2    Kato, C.3
  • 12
    • 0038651141 scopus 로고    scopus 로고
    • Delayed breast cellulitis following breast conserving operation
    • Zippel D, Siegelmann-Danieli N, Ayalon S, et al. Delayed breast cellulitis following breast conserving operation. Eur J Surg Oncol. 2003;29:327-330.
    • (2003) Eur J Surg Oncol , vol.29 , pp. 327-330
    • Zippel, D.1    Siegelmann-Danieli, N.2    Ayalon, S.3
  • 13
    • 84859350221 scopus 로고    scopus 로고
    • Comparison of different ADM materials in breast surgery
    • Cheng A, Saint-Cyr M. Comparison of different ADM materials in breast surgery. Clin Plast Surg. 2012;39:167-75.
    • (2012) Clin Plast Surg , vol.39 , pp. 167-175
    • Cheng, A.1    Saint-Cyr, M.2
  • 14
    • 84876385555 scopus 로고    scopus 로고
    • The evidence base for the acellular dermal matrix AlloDerm: A systematic review
    • Jansen LA, De Caigny P, Guay NA, et al. The evidence base for the acellular dermal matrix AlloDerm: a systematic review. Ann Plast Surg. 2013;70:587-594.
    • (2013) Ann Plast Surg , vol.70 , pp. 587-594
    • Jansen, L.A.1    De Caigny, P.2    Guay, N.A.3
  • 15
    • 84876365403 scopus 로고    scopus 로고
    • Comparison of sterile versus nonsterile acellular dermalmatrices for breast reconstruction
    • Buseman J,Wong L, Kemper P, et al. Comparison of sterile versus nonsterile acellular dermalmatrices for breast reconstruction. Ann Plast Surg. 2013;70:497-499.
    • (2013) Ann Plast Surg , vol.70 , pp. 497-499
    • Buseman, J.1    Wong, L.2    Kemper, P.3
  • 16
    • 84895916485 scopus 로고    scopus 로고
    • Comparison between freeze-dried and readyto-use AlloDerm in alloplastic breast reconstruction
    • Yuen J, Yue C, Erickson S, et al. Comparison between freeze-dried and readyto-use AlloDerm in alloplastic breast reconstruction. Plast Reconstr Surg Glob Open. 2014;2:e119.
    • (2014) Plast Reconstr Surg Glob Open , vol.2 , pp. e119
    • Yuen, J.1    Yue, C.2    Erickson, S.3
  • 17
    • 67651165046 scopus 로고    scopus 로고
    • Freeze-dried acellular dermal matrix graft: Effects of rehydration on physical, chemical, and mechanical properties
    • Bottino MC, Jose MV, Thomas V, et al. Freeze-dried acellular dermal matrix graft: effects of rehydration on physical, chemical, and mechanical properties. Dent Mater. 2009;25:1109-1115.
    • (2009) Dent Mater , vol.25 , pp. 1109-1115
    • Bottino, M.C.1    Jose, M.V.2    Thomas, V.3
  • 18
    • 84988704522 scopus 로고    scopus 로고
    • AlloDerm ready to use; Instructions for use
    • AlloDerm ready to use; instructions for use. LifeCell Corporation. 2012.
    • (2012) LifeCell Corporation


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.