메뉴 건너뛰기




Volumn 85, Issue 1, 2016, Pages 131-135

Effect of Gd-DOTA on fat quantification in skeletal muscle using two-point Dixon technique - Preliminary data

Author keywords

Chemical shift imaging; Fat signal fraction; Gadolinium; Magnetic resonance imaging; Skeletal muscle

Indexed keywords

GADOTERIC ACID; CONTRAST MEDIUM; GADOLINIUM 1,4,7,10-TETRAAZACYCLODODECANE-N,N',N'',N'''-TETRAACETATE; HETEROCYCLIC COMPOUND; ORGANOMETALLIC COMPOUND;

EID: 84955449052     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2015.11.007     Document Type: Article
Times cited : (2)

References (36)
  • 1
    • 84901650695 scopus 로고    scopus 로고
    • Dixon-based MRI for assessment of muscle-fat content in phantoms, healthy volunteers and patients with achillodynia: Comparison to visual assessment of calf muscle quality
    • M.A. Fischer, C.W. Pfirrmann, N. Espinosa, D.A. Raptis, and F.M. Buck Dixon-based MRI for assessment of muscle-fat content in phantoms, healthy volunteers and patients with achillodynia: comparison to visual assessment of calf muscle quality Eur. Radiol. 24 2014 1366 1375
    • (2014) Eur. Radiol. , vol.24 , pp. 1366-1375
    • Fischer, M.A.1    Pfirrmann, C.W.2    Espinosa, N.3    Raptis, D.A.4    Buck, F.M.5
  • 3
    • 84907494629 scopus 로고    scopus 로고
    • In vitro and in vivo comparison of two-, three- and four-point Dixon techniques for clinical intramuscular fat quantification at 3 T
    • J.J. Noble, S.F. Keevil, J. Totman, and G.D. Charles-Edwards In vitro and in vivo comparison of two-, three- and four-point Dixon techniques for clinical intramuscular fat quantification at 3 T Br. J. Radiol. 87 2014 20130761
    • (2014) Br. J. Radiol. , vol.87 , pp. 20130761
    • Noble, J.J.1    Keevil, S.F.2    Totman, J.3    Charles-Edwards, G.D.4
  • 4
    • 84873404384 scopus 로고    scopus 로고
    • Quantification of muscle fat in patients with low back pain: Comparison of multi-echo MR imaging with single-voxel MR spectroscopy
    • M.A. Fischer, D. Nanz, A. Shimakawa, T. Schirmer, R. Guggenberger, A. Chhabra, and et al. Quantification of muscle fat in patients with low back pain: comparison of multi-echo MR imaging with single-voxel MR spectroscopy Radiology 266 2013 555 563
    • (2013) Radiology , vol.266 , pp. 555-563
    • Fischer, M.A.1    Nanz, D.2    Shimakawa, A.3    Schirmer, T.4    Guggenberger, R.5    Chhabra, A.6
  • 5
    • 84867333250 scopus 로고    scopus 로고
    • Quantitative MRI can detect subclinical disease progression in muscular dystrophy
    • A. Fischmann, P. Hafner, S. Fasler, M. Gloor, O. Bieri, U. Studler, and et al. Quantitative MRI can detect subclinical disease progression in muscular dystrophy J. Neurol. 259 2012 1648 1654
    • (2012) J. Neurol. , vol.259 , pp. 1648-1654
    • Fischmann, A.1    Hafner, P.2    Fasler, S.3    Gloor, M.4    Bieri, O.5    Studler, U.6
  • 7
    • 84863591434 scopus 로고    scopus 로고
    • MRI findings, patterns of disease distribution, and muscle fat fraction calculation in five patients with Charcot-Marie-Tooth type 2 F disease
    • M. Gaeta, A. Mileto, A. Mazzeo, F. Minutoli, R. Di Leoi, N. Settineri, and et al. MRI findings, patterns of disease distribution, and muscle fat fraction calculation in five patients with Charcot-Marie-Tooth type 2 F disease Skelet. Radiol. 41 2012 515 524
    • (2012) Skelet. Radiol. , vol.41 , pp. 515-524
    • Gaeta, M.1    Mileto, A.2    Mazzeo, A.3    Minutoli, F.4    Di Leoi, R.5    Settineri, N.6
  • 8
    • 80054815132 scopus 로고    scopus 로고
    • T (1)-corrected fat quantification using chemical shift-based water/fat separation: Application to skeletal muscle
    • D.C. Karampinos, H. Yu, A. Shimakawa, T.M. Link, and S. Majumdar T (1)-corrected fat quantification using chemical shift-based water/fat separation: application to skeletal muscle Magn. Reson. Med. 66 2011 1312 1326
    • (2011) Magn. Reson. Med. , vol.66 , pp. 1312-1326
    • Karampinos, D.C.1    Yu, H.2    Shimakawa, A.3    Link, T.M.4    Majumdar, S.5
  • 9
    • 84858736612 scopus 로고    scopus 로고
    • Characterization of the regional distribution of skeletal muscle adipose tissue in type 2 diabetes using chemical shift-based water/fat separation
    • D.C. Karampinos, T. Baum, L. Nardo, H. Alizai, H. Yu, J. Carballido-Gamio, and et al. Characterization of the regional distribution of skeletal muscle adipose tissue in type 2 diabetes using chemical shift-based water/fat separation J. Magn. Reson. Imaging 35 2012 899 907
    • (2012) J. Magn. Reson. Imaging , vol.35 , pp. 899-907
    • Karampinos, D.C.1    Baum, T.2    Nardo, L.3    Alizai, H.4    Yu, H.5    Carballido-Gamio, J.6
  • 10
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • W.T. Dixon Simple proton spectroscopic imaging Radiology 153 1984 189 194
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.T.1
  • 11
    • 79955040189 scopus 로고    scopus 로고
    • Muscle fat fraction in neuromuscular disorders: Dual-echo dual-flip-angle spoiled gradient-recalled MR imaging technique for quantification - A feasibility study
    • M. Gaeta, E. Scribano, A. Mileto, S. Mazziotti, C. Rodolico, A. Toscano, and et al. Muscle fat fraction in neuromuscular disorders: dual-echo dual-flip-angle spoiled gradient-recalled MR imaging technique for quantification - a feasibility study Radiology 259 2011 487 494
    • (2011) Radiology , vol.259 , pp. 487-494
    • Gaeta, M.1    Scribano, E.2    Mileto, A.3    Mazziotti, S.4    Rodolico, C.5    Toscano, A.6
  • 12
    • 84867834721 scopus 로고    scopus 로고
    • Proton density fat-fraction: A standardized MR-based biomarker of tissue fat concentration
    • S.B. Reeder, H.H. Hu, and C.B. Sirlin Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration J. Magn. Reson. Imaging 36 2012 1011 1014
    • (2012) J. Magn. Reson. Imaging , vol.36 , pp. 1011-1014
    • Reeder, S.B.1    Hu, H.H.2    Sirlin, C.B.3
  • 13
    • 78549235752 scopus 로고    scopus 로고
    • Using chemical-shift MR imaging to quantify fatty degeneration within supraspinatus muscle due to supraspinatus tendon injuries
    • G. Gokalp, N. Yildirim, Z. Yazici, and I. Ercan Using chemical-shift MR imaging to quantify fatty degeneration within supraspinatus muscle due to supraspinatus tendon injuries Skelet. Radiol. 39 2010 1211 1217
    • (2010) Skelet. Radiol. , vol.39 , pp. 1211-1217
    • Gokalp, G.1    Yildirim, N.2    Yazici, Z.3    Ercan, I.4
  • 14
    • 0030043691 scopus 로고    scopus 로고
    • Fatty tissue on opposed-phase MR images: Paradoxical suppression of signal intensity by paramagnetic contrast agents
    • D.G. Mitchell, A.H. Stolpen, E.S. Siegelman, L. Bolinger, and E.K. Outwater Fatty tissue on opposed-phase MR images: paradoxical suppression of signal intensity by paramagnetic contrast agents Radiology 198 1996 351 357
    • (1996) Radiology , vol.198 , pp. 351-357
    • Mitchell, D.G.1    Stolpen, A.H.2    Siegelman, E.S.3    Bolinger, L.4    Outwater, E.K.5
  • 15
    • 84904049838 scopus 로고    scopus 로고
    • Effect of Gd-EOB-DTPA on hepatic fat quantification using high-speed T2-corrected multi-echo acquisition in (1)H MR spectroscopy
    • Y.S. Park, C.H. Lee, J.H. Kim, B.H. Kim, J.H. Kim, K.A. Kim, and et al. Effect of Gd-EOB-DTPA on hepatic fat quantification using high-speed T2-corrected multi-echo acquisition in (1)H MR spectroscopy Magn. Reson. Imaging 32 2014 886 890
    • (2014) Magn. Reson. Imaging , vol.32 , pp. 886-890
    • Park, Y.S.1    Lee, C.H.2    Kim, J.H.3    Kim, B.H.4    Kim, J.H.5    Kim, K.A.6
  • 16
    • 46849101443 scopus 로고    scopus 로고
    • Effects of intravenous gadolinium administration and flip angle on the assessment of liver fat signal fraction with opposed-phase and in-phase imaging
    • T. Yokoo, J.M. Collins, R.F. Hanna, M. Bydder, M.S. Middleton, and C.B. Sirlin Effects of intravenous gadolinium administration and flip angle on the assessment of liver fat signal fraction with opposed-phase and in-phase imaging J. Magn. Reson. Imaging 28 2008 246 251
    • (2008) J. Magn. Reson. Imaging , vol.28 , pp. 246-251
    • Yokoo, T.1    Collins, J.M.2    Hanna, R.F.3    Bydder, M.4    Middleton, M.S.5    Sirlin, C.B.6
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 0041842496 scopus 로고    scopus 로고
    • Measurement of observer agreement
    • H.L. Kundel, and M. Polansky Measurement of observer agreement Radiology 228 2003 303 308
    • (2003) Radiology , vol.228 , pp. 303-308
    • Kundel, H.L.1    Polansky, M.2
  • 19
    • 80052996528 scopus 로고    scopus 로고
    • Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
    • spcone
    • S.B. Reeder, I. Cruite, G. Hamilton, and C.B. Sirlin Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy J. Magn. Reson. Imaging 34 2011 spcone
    • (2011) J. Magn. Reson. Imaging , vol.34
    • Reeder, S.B.1    Cruite, I.2    Hamilton, G.3    Sirlin, C.B.4
  • 20
    • 84876907610 scopus 로고    scopus 로고
    • Nonalcoholic fatty liver disease: MR imaging of liver proton density fat fraction to assess hepatic steatosis
    • A. Tang, J. Tan, M. Sun, G. Hamilton, M. Bydder, T. Wolfson, and et al. Nonalcoholic fatty liver disease: MR imaging of liver proton density fat fraction to assess hepatic steatosis Radiology 267 2013 422 431
    • (2013) Radiology , vol.267 , pp. 422-431
    • Tang, A.1    Tan, J.2    Sun, M.3    Hamilton, G.4    Bydder, M.5    Wolfson, T.6
  • 22
    • 4143101246 scopus 로고    scopus 로고
    • Assessment of fat content in supraspinatus muscle with proton MR spectroscopy in asymptomatic volunteers and patients with supraspinatus tendon lesions
    • C.W. Pfirrmann, M.R. Schmid, M. Zanetti, B. Jost, C. Gerber, and J. Hodler Assessment of fat content in supraspinatus muscle with proton MR spectroscopy in asymptomatic volunteers and patients with supraspinatus tendon lesions Radiology 232 2004 709 715
    • (2004) Radiology , vol.232 , pp. 709-715
    • Pfirrmann, C.W.1    Schmid, M.R.2    Zanetti, M.3    Jost, B.4    Gerber, C.5    Hodler, J.6
  • 23
    • 0030946601 scopus 로고    scopus 로고
    • In vivo determination of intra-myocellular lipids in human muscle by means of localized 1H-MR-spectroscopy
    • C. Boesch, J. Slotboom, H. Hoppeler, and R. Kreis In vivo determination of intra-myocellular lipids in human muscle by means of localized 1H-MR-spectroscopy Magn. Reson. Med. 37 1997 484 493
    • (1997) Magn. Reson. Med. , vol.37 , pp. 484-493
    • Boesch, C.1    Slotboom, J.2    Hoppeler, H.3    Kreis, R.4
  • 24
    • 0033218531 scopus 로고    scopus 로고
    • Fatty degeneration of the muscles of the rotator cuff: Assessment by computed tomography versus magnetic resonance imaging
    • B. Fuchs, D. Weishaupt, M. Zanetti, J. Hodler, and C. Gerber Fatty degeneration of the muscles of the rotator cuff: assessment by computed tomography versus magnetic resonance imaging J. Shoulder Elb. Surg. 8 1999 599 605
    • (1999) J. Shoulder Elb. Surg. , vol.8 , pp. 599-605
    • Fuchs, B.1    Weishaupt, D.2    Zanetti, M.3    Hodler, J.4    Gerber, C.5
  • 25
    • 34547934476 scopus 로고    scopus 로고
    • Fat quantification with IDEAL gradient echo imaging: Correction of bias from T(1) and noise
    • C.Y. Liu, C.A. McKenzie, H. Yu, J.H. Brittain, and S.B. Reeder Fat quantification with IDEAL gradient echo imaging: correction of bias from T(1) and noise Magn. Reson. Med. 58 2007 354 364
    • (2007) Magn. Reson. Med. , vol.58 , pp. 354-364
    • Liu, C.Y.1    McKenzie, C.A.2    Yu, H.3    Brittain, J.H.4    Reeder, S.B.5
  • 28
    • 84905816956 scopus 로고    scopus 로고
    • The protein and contrast agent-specific influence of pathological plasma-protein concentration levels on contrast-enhanced magnetic resonance imaging
    • S. Goetschi, J.M. Froehlich, N.C. Chuck, R. Curcio, V.M. Runge, G. Andreisek, and et al. The protein and contrast agent-specific influence of pathological plasma-protein concentration levels on contrast-enhanced magnetic resonance imaging Investig. Radiol. 49 2014 608 619
    • (2014) Investig. Radiol. , vol.49 , pp. 608-619
    • Goetschi, S.1    Froehlich, J.M.2    Chuck, N.C.3    Curcio, R.4    Runge, V.M.5    Andreisek, G.6
  • 29
    • 84902360840 scopus 로고    scopus 로고
    • Reproducibility, and age, body-weight and gender dependency of candidate skeletal muscle MRI outcome measures in healthy volunteers
    • J.M. Morrow, C.D. Sinclair, A. Fischmann, M.M. Reilly, M.G. Hanna, T.A. Yousry, and et al. Reproducibility, and age, body-weight and gender dependency of candidate skeletal muscle MRI outcome measures in healthy volunteers Eur. Radiol. 24 2014 1610 1620
    • (2014) Eur. Radiol. , vol.24 , pp. 1610-1620
    • Morrow, J.M.1    Sinclair, C.D.2    Fischmann, A.3    Reilly, M.M.4    Hanna, M.G.5    Yousry, T.A.6
  • 30
    • 27144532730 scopus 로고    scopus 로고
    • Accuracy of liver fat quantification at MR imaging: Comparison of out-of-phase gradient-echo and fat-saturated fast spin-echo techniques - Initial experience
    • A. Qayyum, J.S. Goh, S. Kakar, B.M. Yeh, R.B. Merriman, and F.V. Coakley Accuracy of liver fat quantification at MR imaging: comparison of out-of-phase gradient-echo and fat-saturated fast spin-echo techniques - initial experience Radiology 237 2005 507 511
    • (2005) Radiology , vol.237 , pp. 507-511
    • Qayyum, A.1    Goh, J.S.2    Kakar, S.3    Yeh, B.M.4    Merriman, R.B.5    Coakley, F.V.6
  • 31
    • 27544442176 scopus 로고    scopus 로고
    • Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    • M. Rohrer, H. Bauer, J. Mintorovitch, M. Requardt, and H.J. Weinmann Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths Invest. Radiol. 40 2005 715 724
    • (2005) Invest. Radiol. , vol.40 , pp. 715-724
    • Rohrer, M.1    Bauer, H.2    Mintorovitch, J.3    Requardt, M.4    Weinmann, H.J.5
  • 32
    • 33847213864 scopus 로고    scopus 로고
    • Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements: A phase i trial
    • A. Boss, P. Martirosian, M. Gehrmann, F. Artunc, T. Risler, N. Oesingmann, and et al. Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements: a phase I trial Radiology 242 2007 783 790
    • (2007) Radiology , vol.242 , pp. 783-790
    • Boss, A.1    Martirosian, P.2    Gehrmann, M.3    Artunc, F.4    Risler, T.5    Oesingmann, N.6
  • 33
    • 70350469122 scopus 로고    scopus 로고
    • MR imaging in Duchenne muscular dystrophy: Quantification of T1-weighted signal, contrast uptake, and the effects of exercise
    • P. Garrood, K.G. Hollingsworth, M. Eagle, B.S. Aribisala, D. Birchall, K. Bushby, and et al. MR imaging in Duchenne muscular dystrophy: quantification of T1-weighted signal, contrast uptake, and the effects of exercise J. Magn. Reson. Imaging 30 2009 1130 1138
    • (2009) J. Magn. Reson. Imaging , vol.30 , pp. 1130-1138
    • Garrood, P.1    Hollingsworth, K.G.2    Eagle, M.3    Aribisala, B.S.4    Birchall, D.5    Bushby, K.6
  • 35
    • 0032735622 scopus 로고    scopus 로고
    • Signal modulation in (1)H magnetic resonance spectroscopy using contrast agents: Proton relaxivities of choline, creatine, and N-acetylaspartate
    • P.S. Murphy, M.O. Leach, and I.J. Rowland Signal modulation in (1)H magnetic resonance spectroscopy using contrast agents: proton relaxivities of choline, creatine, and N-acetylaspartate Magn. Reson. Med. 42 1999 1155 1158
    • (1999) Magn. Reson. Med. , vol.42 , pp. 1155-1158
    • Murphy, P.S.1    Leach, M.O.2    Rowland, I.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.