메뉴 건너뛰기




Volumn 54, Issue 3, 2005, Pages 586-593

Homodyne reconstruction and IDEAL water-fat decomposition

Author keywords

Homodyne reconstruction; Magnetic resonance imaging; Partial K space; Water fat separation

Indexed keywords

ITERATIVE METHODS; LEAST SQUARES APPROXIMATIONS; MAGNETIC RESONANCE IMAGING; SEPARATION;

EID: 23244468400     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20586     Document Type: Article
Times cited : (71)

References (27)
  • 1
    • 0021132985 scopus 로고
    • Simple proton spectroscopic imaging
    • Dixon W. Simple proton spectroscopic imaging. Radiology 1984;153: 189-194.
    • (1984) Radiology , vol.153 , pp. 189-194
    • Dixon, W.1
  • 2
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • Glover G. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991;1:521-530.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 521-530
    • Glover, G.1
  • 3
    • 0031401552 scopus 로고    scopus 로고
    • Water-fat imaging with direct phase encoding
    • Xiang Q, An L. Water-fat imaging with direct phase encoding. J Magn Reson Imaging 1997;7:1002-1015.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 1002-1015
    • Xiang, Q.1    An, L.2
  • 4
    • 0034782672 scopus 로고    scopus 로고
    • Fast three-point Dixon MR imaging of the retrobulbar space with low-resolution images for phase correction: Comparison with fast spin-echo inversion recovery imaging
    • Rybicki FJ, Mulkern RV, Robertson RL, Robson CD, Chung T, Ma J. Fast three-point Dixon MR imaging of the retrobulbar space with low-resolution images for phase correction: comparison with fast spin-echo inversion recovery imaging. Am J Neuroradiol 2001;22:1798-1802.
    • (2001) Am J Neuroradiol , vol.22 , pp. 1798-1802
    • Rybicki, F.J.1    Mulkern, R.V.2    Robertson, R.L.3    Robson, C.D.4    Chung, T.5    Ma, J.6
  • 7
    • 0347634473 scopus 로고    scopus 로고
    • Multicoil Dixon chemical species separation with an iterative least-squares estimation method
    • Reeder SB, Wen Z, Yu H, Pineda AR, Gold GE, Markl M, Pelc NJ. Multicoil Dixon chemical species separation with an iterative least-squares estimation method. Magn Reson Med 2004;51:35-45.
    • (2004) Magn Reson Med , vol.51 , pp. 35-45
    • Reeder, S.B.1    Wen, Z.2    Yu, H.3    Pineda, A.R.4    Gold, G.E.5    Markl, M.6    Pelc, N.J.7
  • 8
    • 0002842278 scopus 로고
    • FISP. A new fast MRI sequence
    • Oppelt A. FISP. A new fast MRI sequence. Electromedia 1986;3:15-18.
    • (1986) Electromedia , vol.3 , pp. 15-18
    • Oppelt, A.1
  • 9
    • 0023367344 scopus 로고
    • Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals
    • Sekihara K. Steady-state magnetizations in rapid NMR imaging using small flip angles and short repetition intervals. IEEE Trans Med Imaging 1987;6:157-164.
    • (1987) IEEE Trans Med Imaging , vol.6 , pp. 157-164
    • Sekihara, K.1
  • 10
    • 0037306841 scopus 로고    scopus 로고
    • Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation
    • Reeder SB, Pelc NJ, Alley MT, Gold GE. Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation. Am J Roentgenol 2003;180:357-362.
    • (2003) Am J Roentgenol , vol.180 , pp. 357-362
    • Reeder, S.B.1    Pelc, N.J.2    Alley, M.T.3    Gold, G.E.4
  • 12
    • 0027216325 scopus 로고
    • Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI
    • McGibney G, Smith MR, Nichols ST, Crawley A. Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn Reson Med 1993;30:51-59.
    • (1993) Magn Reson Med , vol.30 , pp. 51-59
    • McGibney, G.1    Smith, M.R.2    Nichols, S.T.3    Crawley, A.4
  • 14
    • 0023037011 scopus 로고
    • Halving MR imaging time by conjugation: Demonstration at 3.5 kG
    • Feinberg DA, Hale JD, Watts JC, Kaufman L, Mark A. Halving MR imaging time by conjugation: demonstration at 3.5 kG. Radiology 1986; 161:527-531.
    • (1986) Radiology , vol.161 , pp. 527-531
    • Feinberg, D.A.1    Hale, J.D.2    Watts, J.C.3    Kaufman, L.4    Mark, A.5
  • 15
    • 0001423478 scopus 로고
    • Reducing MR imaging time by one-sided reconstruction
    • Cuppen J, van Est A. Reducing MR imaging time by one-sided reconstruction. Magn Reson Imaging 1987;5:526-527.
    • (1987) Magn Reson Imaging , vol.5 , pp. 526-527
    • Cuppen, J.1    Van Est, A.2
  • 22
    • 0035009703 scopus 로고    scopus 로고
    • Magnetization preparation during the steady state: Fat-saturated 3D TrueFISP
    • Scheffler K, Heid O, Hennig J. Magnetization preparation during the steady state: fat-saturated 3D TrueFISP. Magn Reson Med 2001;45: 1075-1080.
    • (2001) Magn Reson Med , vol.45 , pp. 1075-1080
    • Scheffler, K.1    Heid, O.2    Hennig, J.3
  • 23
    • 0031850853 scopus 로고    scopus 로고
    • Partial Fourier reconstruction for three-dimensional gradient echo functional MRI: Comparison of phase correction methods
    • Stenger A, Noll D, Boada F. Partial Fourier reconstruction for three-dimensional gradient echo functional MRI: comparison of phase correction methods. Magn Reson Med 1998;40:481-490.
    • (1998) Magn Reson Med , vol.40 , pp. 481-490
    • Stenger, A.1    Noll, D.2    Boada, F.3
  • 24
    • 0025298010 scopus 로고
    • Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging
    • Farzaneh F, Riederer SJ, Pelc NJ. Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging. Magn Reson Med 1990;14:123-139.
    • (1990) Magn Reson Med , vol.14 , pp. 123-139
    • Farzaneh, F.1    Riederer, S.J.2    Pelc, N.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.