메뉴 건너뛰기




Volumn 74, Issue 6, 2015, Pages 1726-1732

Pulmonary hyperpolarized 129Xe morphometry for mapping xenon gas concentrations and alveolar oxygen partial pressure: Proof-of-concept demonstration in healthy and COPD subjects

Author keywords

diffusion; hyperpolarized; lung, morphometry; pAO2; xenon concentration

Indexed keywords

BIOLOGICAL ORGANS; DIFFUSION; MAGNETIC RESONANCE IMAGING; OXYGEN; PARTIAL PRESSURE; PHANTOMS; PULMONARY DISEASES; XENON;

EID: 84955171059     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.25550     Document Type: Article
Times cited : (20)

References (22)
  • 2
    • 79952785642 scopus 로고    scopus 로고
    • Diffusion weighted hyperpolarized (129)Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease
    • Kaushik SS, Cleveland ZI, Cofer GP, et al., Diffusion weighted hyperpolarized (129)Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease. Magn Reson Med 2011; 65: 1155-1165.
    • (2011) Magn Reson Med , vol.65 , pp. 1155-1165
    • Kaushik, S.S.1    Cleveland, Z.I.2    Cofer, G.P.3
  • 3
    • 84867910322 scopus 로고    scopus 로고
    • Hyperpolarized helium-3 and xenon-129 magnetic resonance imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease
    • Kirby M, Svenningsen S, Owrangi A, et al., Hyperpolarized helium-3 and xenon-129 magnetic resonance imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease. Radiology 2012; 265: 600-610.
    • (2012) Radiology , vol.265 , pp. 600-610
    • Kirby, M.1    Svenningsen, S.2    Owrangi, A.3
  • 4
    • 84857370695 scopus 로고    scopus 로고
    • Lung morphometry with hyperpolarized 129Xe: Theoretical background
    • Sukstanskii AL, Yablonskiy DA,. Lung morphometry with hyperpolarized 129Xe: theoretical background. Magn Reson Med 2012; 67: 856-866.
    • (2012) Magn Reson Med , vol.67 , pp. 856-866
    • Sukstanskii, A.L.1    Yablonskiy, D.A.2
  • 5
    • 84892441920 scopus 로고    scopus 로고
    • Probing lung microstructure with hyperpolarized noble gas diffusion MRI: Theoretical models and experimental results
    • Yablonskiy DA, Sukstanskii AL, Quirk JD, Woods JC, Conradi MS,. Probing lung microstructure with hyperpolarized noble gas diffusion MRI: theoretical models and experimental results. Magn Reson Med 2014; 71: 486-505.
    • (2014) Magn Reson Med , vol.71 , pp. 486-505
    • Yablonskiy, D.A.1    Sukstanskii, A.L.2    Quirk, J.D.3    Woods, J.C.4    Conradi, M.S.5
  • 6
    • 84888004003 scopus 로고    scopus 로고
    • Lung morphometry using hyperpolarized 129Xe apparent diffusion coefficient anisotropy in chronic obstructive pulmonary disease
    • Ouriadov A, Farag A, Kirby M, McCormack DG, Parraga G, Santyr GE,. Lung morphometry using hyperpolarized 129Xe apparent diffusion coefficient anisotropy in chronic obstructive pulmonary disease. Magn Reson Med 2013; 70: 1699-1706.
    • (2013) Magn Reson Med , vol.70 , pp. 1699-1706
    • Ouriadov, A.1    Farag, A.2    Kirby, M.3    McCormack, D.G.4    Parraga, G.5    Santyr, G.E.6
  • 7
    • 84955190833 scopus 로고    scopus 로고
    • A multiple-breath 3He wash-in regimen to reduce the limitation of 3He pAO2-imaging due to delayed ventilation and slow filling
    • Salt Lake City, Utah, USA, Abstract 0821
    • Hamedani H, Kadlececk S, Han B, Emami K, Xin Y, Ishii M, Rossman M, Rizi R,. A multiple-breath 3He wash-in regimen to reduce the limitation of 3He pAO2-imaging due to delayed ventilation and slow filling. In Proceedings of the 21st Annual Meeting of ISMRM, Salt Lake City, Utah, USA, 2013. Abstract 0821.
    • (2013) Proceedings of the 21st Annual Meeting of ISMRM
    • Hamedani, H.1    Kadlececk, S.2    Han, B.3    Emami, K.4    Xin, Y.5    Ishii, M.6    Rossman, M.7    Rizi, R.8
  • 8
    • 4444320114 scopus 로고    scopus 로고
    • Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan
    • Miller GW, Altes TA, Brookeman JR, de Lange EE, Mugler JP III,. Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan. MAGMA 2004; 16: 218-226.
    • (2004) MAGMA , vol.16 , pp. 218-226
    • Miller, G.W.1    Altes, T.A.2    Brookeman, J.R.3    De Lange, E.E.4    Mugler, J.P.5
  • 9
    • 84955204457 scopus 로고    scopus 로고
    • Correction of errors due to RF field inhomogeneities in hyperpolarized 3He measurement of alveolar oxygen partial pressure in human lung
    • Toronto, Canada, Abstract 3786
    • Ouriadov A, Etemad-Rezai R, Parraga G, Santyr GE,. Correction of errors due to RF field inhomogeneities in hyperpolarized 3He measurement of alveolar oxygen partial pressure in human lung. In Proceedings of the 16th Annual Meeting of ISMRM, Toronto, Canada, 2008. Abstract 3786.
    • (2008) Proceedings of the 16th Annual Meeting of ISMRM
    • Ouriadov, A.1    Etemad-Rezai, R.2    Parraga, G.3    Santyr, G.E.4
  • 10
    • 84894475670 scopus 로고    scopus 로고
    • 3He pO2 mapping is limited by delayed-ventilation and diffusion in chronic obstructive pulmonary disease
    • Marshall H, Parra-Robles J, Deppe MH, Lipson DA, Lawson R, Wild JM,. 3He pO2 mapping is limited by delayed-ventilation and diffusion in chronic obstructive pulmonary disease. Magn Reson Med 2014; 71: 1172-1178.
    • (2014) Magn Reson Med , vol.71 , pp. 1172-1178
    • Marshall, H.1    Parra-Robles, J.2    Deppe, M.H.3    Lipson, D.A.4    Lawson, R.5    Wild, J.M.6
  • 13
    • 84867913057 scopus 로고    scopus 로고
    • Unshielded and asymmetric RF transmit coil for hyperpolarized 129Xe human lung imaging at 3.0T
    • Melbourne, Australia Abstract 1233
    • Farag A, Wang J, Ouriadov A, Parraga G, Santyr G,. Unshielded and asymmetric RF transmit coil for hyperpolarized 129Xe human lung imaging at 3.0T. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. Abstract 1233.
    • (2012) Proceedings of the 20th Annual Meeting of ISMRM
    • Farag, A.1    Wang, J.2    Ouriadov, A.3    Parraga, G.4    Santyr, G.5
  • 14
    • 43249093673 scopus 로고    scopus 로고
    • Large production system for hyperpolarized 129Xe for human lung imaging studies
    • Hersman FW, Ruset IC, Ketel S, et al., Large production system for hyperpolarized 129Xe for human lung imaging studies. Acad Radiol 2008; 15: 683-692.
    • (2008) Acad Radiol , vol.15 , pp. 683-692
    • Hersman, F.W.1    Ruset, I.C.2    Ketel, S.3
  • 19
    • 84955188254 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe magnetic resonance imaging lung morphometry method for estimation of xenon concentration gradients in chronic obstructive pulmonary disease
    • Salt Lake City, Utah, USA, Abstract 1457
    • Ouriadov A, Kirby M, Farag A, McCormack DG, Parraga G, Santyr GE,. Hyperpolarized 129Xe magnetic resonance imaging lung morphometry method for estimation of xenon concentration gradients in chronic obstructive pulmonary disease. In Proceedings of the 21st Annual Meeting of ISMRM, Salt Lake City, Utah, USA, 2013. Abstract 1457.
    • (2013) Proceedings of the 21st Annual Meeting of ISMRM
    • Ouriadov, A.1    Kirby, M.2    Farag, A.3    McCormack, D.G.4    Parraga, G.5    Santyr, G.E.6
  • 20
    • 84872943964 scopus 로고    scopus 로고
    • Hyperpolarized 129Xe MRI of the human lung
    • Mugler JP, Altes TA,. Hyperpolarized 129Xe MRI of the human lung. J Magn Reson Imaging 2013; 37: 313-331.
    • (2013) J Magn Reson Imaging , vol.37 , pp. 313-331
    • Mugler, J.P.1    Altes, T.A.2
  • 21
    • 84883373676 scopus 로고    scopus 로고
    • Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI
    • Nikolaou P, Coffey AM, Walkup LL, et al., Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI. Proc Natl Acad Sci U S A 2013; 110: 14150-14155.
    • (2013) Proc Natl Acad Sci U S A , vol.110 , pp. 14150-14155
    • Nikolaou, P.1    Coffey, A.M.2    Walkup, L.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.