메뉴 건너뛰기




Volumn , Issue , 2014, Pages 259-278

BACs-on-beads™ (BoBs™) assay for the genetic evaluation of prenatal samples and products of conception

Author keywords

Microdeletion; Aneuploidies; KaryoLite BACs on beads; Karyotype; Microduplication; Prenatal BACs on beads; Prenatal diagnosis; Product of conception

Indexed keywords

BACTERIAL ARTIFICIAL CHROMOSOME; CHROMOSOME 13; CHROMOSOME 18; CHROMOSOME 21; CHROMOSOME DELETION; COMPUTER PROGRAM; COPY NUMBER VARIATION; DEVICES; FEMALE; GENETICS; HUMAN; MALE; METABOLISM; MOSAICISM; PERSONALIZED MEDICINE; PREGNANCY; PRENATAL DIAGNOSIS; PROCEDURES; TRISOMY;

EID: 84954597224     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1007/978-1-4939-1652-8_13     Document Type: Chapter
Times cited : (8)

References (19)
  • 1
    • 0036469895 scopus 로고    scopus 로고
    • Simultaneous quantification of proinflammatory cytokines in human plasma using the LabMAP (TM) assay
    • Prabhakar U, Eirikis E, Davis HM (2002) Simultaneous quantification of proinflammatory cytokines in human plasma using the LabMAP (TM) assay. J Immunol Methods 260:207-218
    • (2002) J Immunol Methods , vol.260 , pp. 207-218
    • Prabhakar, U.1    Eirikis, E.2    Davis, H.M.3
  • 2
    • 0036146140 scopus 로고    scopus 로고
    • Development of internal controls for the Luminex instrument as part of a multiplex seven-analyte viral respiratory antibody profile
    • Martins TB (2002) Development of internal controls for the Luminex instrument as part of a multiplex seven-analyte viral respiratory antibody profile. Clin Diagn Lab Immunol 9:41-45
    • (2002) Clin Diagn Lab Immunol , vol.9 , pp. 41-45
    • Martins, T.B.1
  • 3
    • 0035071595 scopus 로고    scopus 로고
    • Fluorescent microsphere-based readout technology for multiplexed human single nucleotide polymorphism analysis and bacterial identification
    • Ye F, Li MS et al (2001) Fluorescent microsphere-based readout technology for multiplexed human single nucleotide polymorphism analysis and bacterial identification. Hum Mutat 17:305-316
    • (2001) Hum Mutat , vol.17 , pp. 305-316
    • Ye, F.1    Li, M.S.2
  • 4
    • 0035092024 scopus 로고    scopus 로고
    • Flow cytometric platform for highthroughput single nucleotide polymorphism analysis
    • Taylor JD, Briley D et al (2001) Flow cytometric platform for highthroughput single nucleotide polymorphism analysis. Biotechniques 30:661-675
    • (2001) Biotechniques , vol.30 , pp. 661-675
    • Taylor, J.D.1    Briley, D.2
  • 5
    • 0034747127 scopus 로고    scopus 로고
    • BADGE, BeadsArray for the detection of gene expression, a high-throughput diagnostic bioassay
    • Yang L, Tran DK, Wang X (2001) BADGE, BeadsArray for the detection of gene expression, a high-throughput diagnostic bioassay. Genome Res 11:1888-1898
    • (2001) Genome Res , vol.11 , pp. 1888-1898
    • Yang, L.1    Tran, D.K.2    Wang, X.3
  • 6
    • 0000408707 scopus 로고    scopus 로고
    • Application of the Luminex LabMAP in rapid screening for mutations in the cystic fibrosis transmembrane conductance regulator gene: a pilot study
    • Dunbar SA, Jacobson JW (2000) Application of the Luminex LabMAP in rapid screening for mutations in the cystic fibrosis transmembrane conductance regulator gene: a pilot study. Clin Chem 46:1498-1500
    • (2000) Clin Chem , vol.46 , pp. 1498-1500
    • Dunbar, S.A.1    Jacobson, J.W.2
  • 7
    • 0034699375 scopus 로고    scopus 로고
    • Multiplexed particlebased flow cytometric assays
    • Vignali DAA (2000) Multiplexed particlebased flow cytometric assays. J Immunol Methods 243:243-255
    • (2000) J Immunol Methods , vol.243 , pp. 243-255
    • Vignali, D.A.A.1
  • 8
    • 0032856945 scopus 로고    scopus 로고
    • Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
    • Carson RT, Vignali DAA (1999) Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods 227:41-52
    • (1999) J Immunol Methods , vol.227 , pp. 41-52
    • Carson, R.T.1    Vignali, D.A.A.2
  • 9
    • 0030870964 scopus 로고    scopus 로고
    • Multiplexed quantification of human IgG, IgA, and IgM with the FlowMetrix(TM) system
    • Gordon RF, McDade RL (1997) Multiplexed quantification of human IgG, IgA, and IgM with the FlowMetrix(TM) system. Clin Chem 43:1799-1801
    • (1997) Clin Chem , vol.43 , pp. 1799-1801
    • Gordon, R.F.1    McDade, R.L.2
  • 10
    • 0043164695 scopus 로고    scopus 로고
    • A novel rapid multiplexed assay for herpes simplex virus DNA using the FlowMetrix(TM) cytometric microsphere technology
    • WalkerPeach CR, Smith PL et al (1997) A novel rapid multiplexed assay for herpes simplex virus DNA using the FlowMetrix(TM) cytometric microsphere technology. Clin Chem 43:21
    • (1997) Clin Chem , vol.43 , pp. 21
    • WalkerPeach, C.R.1    Smith, P.L.2
  • 11
    • 0031783422 scopus 로고    scopus 로고
    • A rapid, sensitive, multiplexed assay for detection of viral nucleic acids using the FlowMetrix system
    • Smith PL, WalkerPeach CR et al (1998) A rapid, sensitive, multiplexed assay for detection of viral nucleic acids using the FlowMetrix system. Clin Chem 44:2054-2056
    • (1998) Clin Chem , vol.44 , pp. 2054-2056
    • Smith, P.L.1    WalkerPeach, C.R.2
  • 12
    • 0031721423 scopus 로고    scopus 로고
    • Multiplexed analysis of human cytokines by use of the FlowMetrix system
    • Oliver KG, Kettman JR, Fulton RJ (1998) Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem 44:2057-2060
    • (1998) Clin Chem , vol.44 , pp. 2057-2060
    • Oliver, K.G.1    Kettman, J.R.2    Fulton, R.J.3
  • 13
    • 0033816504 scopus 로고    scopus 로고
    • Simultaneous measurement of thyroxine and thyrotropin from newborn dried blood-spot specimens using a multiplexed fluorescent microsphere immunoassay
    • Bellisario R, Colinas RJ, Pass KA (2000) Simultaneous measurement of thyroxine and thyrotropin from newborn dried blood-spot specimens using a multiplexed fluorescent microsphere immunoassay. Clin Chem 46:1422-1424
    • (2000) Clin Chem , vol.46 , pp. 1422-1424
    • Bellisario, R.1    Colinas, R.J.2    Pass, K.A.3
  • 14
    • 28544446736 scopus 로고    scopus 로고
    • Applications of Luminex xMAP technology for rapid, high-throughput multiplexed nucleic acid detection
    • Dunbar SA (2006) Applications of Luminex xMAP technology for rapid, high-throughput multiplexed nucleic acid detection. Clin Chim Acta 363:71-82
    • (2006) Clin Chim Acta , vol.363 , pp. 71-82
    • Dunbar, S.A.1
  • 15
    • 79954741750 scopus 로고    scopus 로고
    • Prenatal BACs-on-Beads™: a new technology for rapid detection of aneuploidies and microdeletions in prenatal diagnosis
    • Vialard F, Simoni G et al (2011) Prenatal BACs-on-Beads™: a new technology for rapid detection of aneuploidies and microdeletions in prenatal diagnosis. Prenat Diagn 31:500-508
    • (2011) Prenat Diagn , vol.31 , pp. 500-508
    • Vialard, F.1    Simoni, G.2
  • 16
    • 84869883251 scopus 로고    scopus 로고
    • Prenatal diagnosis of the duplication 17p11.2 associated with Potocki-Lupski syndrome in a foetus presenting with mildly dysmorphic features
    • Popowski T, Molina-Gomes D et al (2012) Prenatal diagnosis of the duplication 17p11.2 associated with Potocki-Lupski syndrome in a foetus presenting with mildly dysmorphic features. Eur J Med Genet 55:723-726
    • (2012) Eur J Med Genet , vol.55 , pp. 723-726
    • Popowski, T.1    Molina-Gomes, D.2
  • 17
    • 79952213667 scopus 로고    scopus 로고
    • Rapid and novel prenatal molecular assay for detecting aneuploidies and microdeletion syndromes
    • Gross SJ, Bajaj K et al (2011) Rapid and novel prenatal molecular assay for detecting aneuploidies and microdeletion syndromes. Prenat Diagn 31:259-266
    • (2011) Prenat Diagn , vol.31 , pp. 259-266
    • Gross, S.J.1    Bajaj, K.2
  • 18
    • 84872155951 scopus 로고    scopus 로고
    • Application of a new molecular technique for the genetic evaluation of products of conception
    • Grati FR, Gomes DM et al (2013) Application of a new molecular technique for the genetic evaluation of products of conception. Prenat Diagn 33:32-41
    • (2013) Prenat Diagn , vol.33 , pp. 32-41
    • Grati, F.R.1    Gomes, D.M.2
  • 19
    • 84859147595 scopus 로고    scopus 로고
    • Prenatal BACs-on-Beads™: the prospective experience of five prenatal diagnosis laboratories
    • Vialard F, Simoni G et al (2012) Prenatal BACs-on-Beads™: the prospective experience of five prenatal diagnosis laboratories. Prenat Diagn 32:329-335
    • (2012) Prenat Diagn , vol.32 , pp. 329-335
    • Vialard, F.1    Simoni, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.