Volumn 11, Issue 8, 2015, Pages 877-884

Treatment of coronary bifurcation lesions with the Absorb bioresorbable vascular scaffold in combination with the Tryton dedicated coronary bifurcation stent: Evaluation using two-and three-dimensional optical coherence tomography

Author keywords

Coronary artery disease; Coronary bifurcations; Optical coherence tomography

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; BIORESORBABLE SCAFFOLD; CLINICAL ARTICLE; CORONARY ARTERY RECANALIZATION; CORONARY BIFURCATION LESION; CORONARY STENT; CORONARY STENTING; FOLLOW UP; HUMAN; MALE; MIDDLE AGED; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL COHERENCE TOMOGRAPHY DEVICE; PERCUTANEOUS CORONARY INTERVENTION; THREE DIMENSIONAL OPTICAL COHERENCE TOMOGRAPHY; TREATMENT OUTCOME; TWO DIMENSIONAL OPTICAL COHERENCE TOMOGRAPHY; ADVERSE EFFECTS; BIODEGRADABLE IMPLANT; COMPUTER ASSISTED DIAGNOSIS; CORONARY ANGIOGRAPHY; CORONARY ARTERY DISEASE; CORONARY BLOOD VESSEL; DEVICES; FEMALE; PATHOLOGY; PREDICTIVE VALUE; PROCEDURES; PROSTHESIS DESIGN; RADIOGRAPHY; STENT; THREE DIMENSIONAL IMAGING; TIME FACTOR;

EID: 84954234192     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJY14M08_15     Document Type: Article
Times cited : (11)

References (23)
  • 3
    • 80051548809 scopus 로고    scopus 로고
    • Major limitations of randomized clinical trials involving coronary artery bifurcation interventions: Time for redesigning clinical trials by involving only true bifurcation lesions and using appropriate bifurcation classification
    • Movahed MR. Major limitations of randomized clinical trials involving coronary artery bifurcation interventions: time for redesigning clinical trials by involving only true bifurcation lesions and using appropriate bifurcation classification. J Interv Cardiol. 2011;24:295-301.
    • (2011) J Interv Cardiol. , vol.24 , pp. 295-301
    • Movahed, M.R.1
  • 4
    • 84859073656 scopus 로고    scopus 로고
    • Why the provisional single-stent approach is not always the right strategy; Arguments for the development of dedicated bifurcation devices
    • Grundeken MJ, Stella PR, Wykrzykowska JJ. Why the provisional single-stent approach is not always the right strategy; arguments for the development of dedicated bifurcation devices. EuroIntervention. 2012;7:1249-53.
    • (2012) EuroIntervention. , vol.7 , pp. 1249-1253
    • Grundeken, M.J.1    Stella, P.R.2    Wykrzykowska, J.J.3
  • 7
    • 84871681721 scopus 로고    scopus 로고
    • Crush, culotte, T and protrusion: Which 2-stent technique for treatment of true bifurcation lesions?-insights from in vitro experiments and micro-computed tomography
    • Foin N, Alegria-Barrero E, Torii R, Chan PH, Viceconte N, Davies JE, Di Mario C. Crush, culotte, T and protrusion: which 2-stent technique for treatment of true bifurcation lesions?-insights from in vitro experiments and micro-computed tomography. Circ J. 2013;77:73-80.
    • (2013) Circ J. , vol.77 , pp. 73-80
    • Foin, N.1    Alegria-Barrero, E.2    Torii, R.3    Chan, P.H.4    Viceconte, N.5    Davies, J.E.6    Di Mario, C.7
  • 14
    • 33645555235 scopus 로고    scopus 로고
    • A new classification of coronary bifurcation lesions
    • Medina A, Suarez de Lezo J, Pan M. [A new classification of coronary bifurcation lesions]. Rev Esp Cardiol. 2006;59:183.
    • (2006) Rev Esp Cardiol. , vol.59 , pp. 183
    • Medina, A.1    Suarez De Lezo, J.2    Pan, M.3
  • 18
    • 84858328457 scopus 로고    scopus 로고
    • High-speed intracoronary optical frequency domain imaging: Implications for three-dimensional reconstruction and quantitative analysis
    • Okamura T, Onuma Y, Garcia-Garcia HM, Bruining N, Serruys PW. High-speed intracoronary optical frequency domain imaging: implications for three-dimensional reconstruction and quantitative analysis. EuroIntervention. 2012;7:1216-26.
    • (2012) EuroIntervention. , vol.7 , pp. 1216-1226
    • Okamura, T.1    Onuma, Y.2    Garcia-Garcia, H.M.3    Bruining, N.4    Serruys, P.W.5
  • 21
  • 23
    • 77956403637 scopus 로고    scopus 로고
    • Cardiovascular flashlight. The fate of bioresorbable struts located at a side branch ostium: Serial three-dimensional optical coherence tomography assessment
    • Okamura T, Serruys PW, Regar E. Cardiovascular flashlight. The fate of bioresorbable struts located at a side branch ostium: serial three-dimensional optical coherence tomography assessment. Eur Heart J. 2010;31:2179.
    • (2010) Eur Heart J. , vol.31 , pp. 2179
    • Okamura, T.1    Serruys, P.W.2    Regar, E.3