메뉴 건너뛰기




Volumn 7, Issue 12, 2015, Pages 2151-2157

Left ventricular assist device driveline infections: Recent advances and future goals

Author keywords

Biofilm; Device related infection; Driveline infections (DLIs); Left ventricular assist devices (LVADs)

Indexed keywords

CIPROFLOXACIN; DOXYCYCLINE; RIFAMPICIN;

EID: 84954182656     PISSN: 20721439     EISSN: 20776624     Source Type: Journal    
DOI: 10.3978/j.issn.2072-1439.2015.11.06     Document Type: Review
Times cited : (69)

References (42)
  • 1
    • 80655144951 scopus 로고    scopus 로고
    • Left ventricular assist device driveline infections
    • Pereda D, Conte JV. Left ventricular assist device driveline infections. Cardiol Clin 2011;29:515-27.
    • (2011) Cardiol Clin , vol.29 , pp. 515-527
    • Pereda, D.1    Conte, J.V.2
  • 2
    • 84940723713 scopus 로고    scopus 로고
    • Hospital Readmissions After Continuous-Flow Left Ventricular Assist Device Implantation: Incidence, Causes, and Cost Analysis
    • Akhter SA, Badami A, Murray M, et al. Hospital Readmissions After Continuous-Flow Left Ventricular Assist Device Implantation: Incidence, Causes, and Cost Analysis. Ann Thorac Surg 2015;100:884-9.
    • (2015) Ann Thorac Surg , vol.100 , pp. 884-889
    • Akhter, S.A.1    Badami, A.2    Murray, M.3
  • 3
    • 0034327442 scopus 로고    scopus 로고
    • Can infections be imaged in implanted devices?
    • Wickline SA, Fischer KC. Can infections be imaged in implanted devices? ASAIO J 2000;46:S80-1.
    • (2000) ASAIO J , vol.46 , pp. S80-S81
    • Wickline, S.A.1    Fischer, K.C.2
  • 4
    • 84887919812 scopus 로고    scopus 로고
    • Clinical manifestations and management of left ventricular assist device-associated infections
    • Nienaber JJ, Kusne S, Riaz T, et al. Clinical manifestations and management of left ventricular assist device-associated infections. Clin Infect Dis 2013;57:1438-48.
    • (2013) Clin Infect Dis , vol.57 , pp. 1438-1448
    • Nienaber, J.J.1    Kusne, S.2    Riaz, T.3
  • 5
    • 84964693504 scopus 로고    scopus 로고
    • A review of infections in patients with left ventricular assist devices: prevention, diagnosis and management
    • Trachtenberg BH, Cordero-Reyes A, Elias B, et al. A review of infections in patients with left ventricular assist devices: prevention, diagnosis and management. Methodist Debakey Cardiovasc J 2015;11:28-32.
    • (2015) Methodist Debakey Cardiovasc J , vol.11 , pp. 28-32
    • Trachtenberg, B.H.1    Cordero-Reyes, A.2    Elias, B.3
  • 6
    • 84867582886 scopus 로고    scopus 로고
    • Continuousflow devices and percutaneous site infections: clinical outcomes
    • Goldstein DJ, Naftel D, Holman W, et al. Continuousflow devices and percutaneous site infections: clinical outcomes. J Heart Lung Transplant 2012;31:1151-7.
    • (2012) J Heart Lung Transplant , vol.31 , pp. 1151-1157
    • Goldstein, D.J.1    Naftel, D.2    Holman, W.3
  • 7
    • 84874928016 scopus 로고    scopus 로고
    • Ventricular assist device related infections and solid organ transplantation
    • Koval CE, Rakita R; AST Infectious Diseases Community of Practice. Ventricular assist device related infections and solid organ transplantation. Am J Transplant 2013;13 Suppl 4:348-54.
    • (2013) Am J Transplant , vol.13 , pp. 348-354
    • Koval, C.E.1    Rakita, R.2
  • 8
    • 79952755019 scopus 로고    scopus 로고
    • Working formulation for the standardization of definitions of infections in patients using ventricular assist devices
    • Hannan MM, Husain S, Mattner F, et al. Working formulation for the standardization of definitions of infections in patients using ventricular assist devices. J Heart Lung Transplant 2011;30:375-84.
    • (2011) J Heart Lung Transplant , vol.30 , pp. 375-384
    • Hannan, M.M.1    Husain, S.2    Mattner, F.3
  • 9
    • 84930808528 scopus 로고    scopus 로고
    • Impact of age on outcomes following continuous-flow left ventricular assist device implantation
    • Lushaj EB, Badami A, Osaki S, et al. Impact of age on outcomes following continuous-flow left ventricular assist device implantation. Interact Cardiovasc Thorac Surg 2015;20:743-8.
    • (2015) Interact Cardiovasc Thorac Surg , vol.20 , pp. 743-748
    • Lushaj, E.B.1    Badami, A.2    Osaki, S.3
  • 10
    • 34447565878 scopus 로고    scopus 로고
    • Late-onset driveline infections: the Achilles' heel of prolonged left ventricular assist device support
    • Zierer A, Melby SJ, Voeller RK, et al. Late-onset driveline infections: the Achilles' heel of prolonged left ventricular assist device support. Ann Thorac Surg 2007;84:515-20.
    • (2007) Ann Thorac Surg , vol.84 , pp. 515-520
    • Zierer, A.1    Melby, S.J.2    Voeller, R.K.3
  • 11
    • 84929045300 scopus 로고    scopus 로고
    • Role of gallium SPECT-CT in the diagnosis of left ventricular assist device infections
    • Levy DT, Minamoto GY, Da Silva R, et al. Role of gallium SPECT-CT in the diagnosis of left ventricular assist device infections. ASAIO J 2015;61:e5-10.
    • (2015) ASAIO J , vol.61 , pp. e5-e10
    • Levy, D.T.1    Minamoto, G.Y.2    Da Silva, R.3
  • 12
    • 84954155175 scopus 로고    scopus 로고
    • Contributory Role of Fluorine 18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in the Diagnosis and Clinical Management of Infections in Patients Supported With a Continuous-Flow Left Ventricular Assist Device
    • Dell'Aquila AM, Mastrobuoni S, Alles S, et al. Contributory Role of Fluorine 18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in the Diagnosis and Clinical Management of Infections in Patients Supported With a Continuous-Flow Left Ventricular Assist Device. Ann Thorac Surg 2016;101:87-94.
    • (2016) Ann Thorac Surg , vol.101 , pp. 87-94
    • Dell'Aquila, A.M.1    Mastrobuoni, S.2    Alles, S.3
  • 13
    • 84954106575 scopus 로고    scopus 로고
    • FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device
    • Fujino T, Higo T, Tanoue Y, et al. FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device. Eur Heart J Cardiovasc Imaging 2016;17:23.
    • (2016) Eur Heart J Cardiovasc Imaging , vol.17 , pp. 23
    • Fujino, T.1    Higo, T.2    Tanoue, Y.3
  • 14
    • 84873910213 scopus 로고    scopus 로고
    • Current concepts in the diagnosis and management of left ventricular assist device infections
    • Nienaber J, Wilhelm MP, Sohail MR. Current concepts in the diagnosis and management of left ventricular assist device infections. Expert Rev Anti Infect Ther 2013;11:201-10.
    • (2013) Expert Rev Anti Infect Ther , vol.11 , pp. 201-210
    • Nienaber, J.1    Wilhelm, M.P.2    Sohail, M.R.3
  • 15
    • 84945444527 scopus 로고    scopus 로고
    • Complicated Left Ventricular Assist Device Infection Treated With Pump Exchange and Left Ventricular Apical Resection
    • Hamdan R, Ali F, Saab M. Complicated Left Ventricular Assist Device Infection Treated With Pump Exchange and Left Ventricular Apical Resection. Artif Organs 2015;39:981-2.
    • (2015) Artif Organs , vol.39 , pp. 981-982
    • Hamdan, R.1    Ali, F.2    Saab, M.3
  • 16
    • 84908021593 scopus 로고    scopus 로고
    • Evolution and impact of drive-line infection in a large cohort of continuous-flow ventricular assist device recipients
    • Koval CE, Thuita L, Moazami N, et al. Evolution and impact of drive-line infection in a large cohort of continuous-flow ventricular assist device recipients. J Heart Lung Transplant 2014;33:1164-72.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 1164-1172
    • Koval, C.E.1    Thuita, L.2    Moazami, N.3
  • 17
    • 84937053695 scopus 로고    scopus 로고
    • Suspected involvement of EPTFE membrane in sterile intrathoracic abscess and pericardial empyema in a multi-allergic LVAD recipient: a case report
    • Kornberger A, Walter V, Khalil M, et al. Suspected involvement of EPTFE membrane in sterile intrathoracic abscess and pericardial empyema in a multi-allergic LVAD recipient: a case report. J Cardiothorac Surg 2015;10:99.
    • (2015) J Cardiothorac Surg , vol.10 , pp. 99
    • Kornberger, A.1    Walter, V.2    Khalil, M.3
  • 18
    • 79954618938 scopus 로고    scopus 로고
    • Role of biofilm in Staphylococcus aureus and Staphylococcus epidermidis ventricular assist device driveline infections
    • Toba FA, Akashi H, Arrecubieta C, et al. Role of biofilm in Staphylococcus aureus and Staphylococcus epidermidis ventricular assist device driveline infections. J Thorac Cardiovasc Surg 2011;141:1259-64.
    • (2011) J Thorac Cardiovasc Surg , vol.141 , pp. 1259-1264
    • Toba, F.A.1    Akashi, H.2    Arrecubieta, C.3
  • 20
    • 84937564449 scopus 로고    scopus 로고
    • Readmissions After Continuous Flow Left Ventricular Assist Device Implantation: Differences Observed Between Two Contemporary Device Types
    • Haglund NA, Davis ME, Tricarico NM, et al. Readmissions After Continuous Flow Left Ventricular Assist Device Implantation: Differences Observed Between Two Contemporary Device Types. ASAIO J 2015;61:410-6.
    • (2015) ASAIO J , vol.61 , pp. 410-416
    • Haglund, N.A.1    Davis, M.E.2    Tricarico, N.M.3
  • 21
    • 84872856797 scopus 로고    scopus 로고
    • Optimizing combination rifampin therapy for staphylococcal osteoarticular infections
    • Coiffier G, Albert JD, Arvieux C, et al. Optimizing combination rifampin therapy for staphylococcal osteoarticular infections. Joint Bone Spine 2013;80:11-7.
    • (2013) Joint Bone Spine , vol.80 , pp. 11-17
    • Coiffier, G.1    Albert, J.D.2    Arvieux, C.3
  • 22
    • 84885920711 scopus 로고    scopus 로고
    • In vitro efficacies and resistance profiles of rifampin-based combination regimens for biofilm-embedded methicillin-resistant Staphylococcus aureus
    • Tang HJ, Chen CC, Cheng KC, et al. In vitro efficacies and resistance profiles of rifampin-based combination regimens for biofilm-embedded methicillin-resistant Staphylococcus aureus. Antimicrob Agents Chemother 2013;57:5717-20.
    • (2013) Antimicrob Agents Chemother , vol.57 , pp. 5717-5720
    • Tang, H.J.1    Chen, C.C.2    Cheng, K.C.3
  • 23
    • 74249103796 scopus 로고    scopus 로고
    • Rifampin combination therapy for nonmycobacterial infections
    • Forrest GN, Tamura K. Rifampin combination therapy for nonmycobacterial infections. Clin Microbiol Rev 2010;23:14-34.
    • (2010) Clin Microbiol Rev , vol.23 , pp. 14-34
    • Forrest, G.N.1    Tamura, K.2
  • 24
    • 84945488746 scopus 로고    scopus 로고
    • Incidence and Risk Factor Analysis for Gastrointestinal Bleeding and Pump Thrombosis in Left Ventricular Assist Device Recipients
    • Lopilato AC, Doligalski CT, Caldeira C. Incidence and Risk Factor Analysis for Gastrointestinal Bleeding and Pump Thrombosis in Left Ventricular Assist Device Recipients. Artif Organs 2015;39:939-44.
    • (2015) Artif Organs , vol.39 , pp. 939-944
    • Lopilato, A.C.1    Doligalski, C.T.2    Caldeira, C.3
  • 25
    • 84921872306 scopus 로고    scopus 로고
    • Persistent blood stream infection in patients supported with a continuous-flow left ventricular assist device is associated with an increased risk of cerebrovascular accidents
    • Trachtenberg BH, Cordero-Reyes AM, Aldeiri M, et al. Persistent blood stream infection in patients supported with a continuous-flow left ventricular assist device is associated with an increased risk of cerebrovascular accidents. J Card Fail 2015;21:119-25.
    • (2015) J Card Fail , vol.21 , pp. 119-125
    • Trachtenberg, B.H.1    Cordero-Reyes, A.M.2    Aldeiri, M.3
  • 26
    • 84916233448 scopus 로고    scopus 로고
    • Clinical outcomes associated with chronic antimicrobial suppression therapy in patients with continuous-flow left ventricular assist devices
    • Jennings DL, Chopra A, Chambers R, et al. Clinical outcomes associated with chronic antimicrobial suppression therapy in patients with continuous-flow left ventricular assist devices. Artif Organs 2014;38:875-9.
    • (2014) Artif Organs , vol.38 , pp. 875-879
    • Jennings, D.L.1    Chopra, A.2    Chambers, R.3
  • 27
    • 84872765576 scopus 로고    scopus 로고
    • Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality
    • Moazami N, Milano CA, John R, et al. Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality. Ann Thorac Surg 2013;95:500-5.
    • (2013) Ann Thorac Surg , vol.95 , pp. 500-505
    • Moazami, N.1    Milano, C.A.2    John, R.3
  • 28
    • 84922327010 scopus 로고    scopus 로고
    • Continuous-flow ventricular assist device exchange is safe and effective in prolonging support time in patients with end-stage heart failure
    • Anand J, Singh SK, Hernández R, et al. Continuous-flow ventricular assist device exchange is safe and effective in prolonging support time in patients with end-stage heart failure. J Thorac Cardiovasc Surg 2015;149:267-75, 278.e1.
    • (2015) J Thorac Cardiovasc Surg , vol.149 , pp. 267-275
    • Anand, J.1    Singh, S.K.2    Hernández, R.3
  • 29
    • 84901982475 scopus 로고    scopus 로고
    • Left ventricular assist device exchange for persistent infection: a case series and review of the literature
    • Levy DT, Guo Y, Simkins J, et al. Left ventricular assist device exchange for persistent infection: a case series and review of the literature. Transpl Infect Dis 2014;16:453-60.
    • (2014) Transpl Infect Dis , vol.16 , pp. 453-460
    • Levy, D.T.1    Guo, Y.2    Simkins, J.3
  • 30
    • 84949088019 scopus 로고    scopus 로고
    • Safety and Feasibility of Induction Immunosuppression When Driveline Infection Is an Indication for Cardiac Transplantation
    • Bhatia N, Voelkel AJ, Hussain Z, et al. Safety and Feasibility of Induction Immunosuppression When Driveline Infection Is an Indication for Cardiac Transplantation. Thorac Cardiovasc Surg 2015;63:675-83.
    • (2015) Thorac Cardiovasc Surg , vol.63 , pp. 675-683
    • Bhatia, N.1    Voelkel, A.J.2    Hussain, Z.3
  • 31
    • 84884990141 scopus 로고    scopus 로고
    • Heart transplantation in a patient with heteroresistant vancomycin-intermediate Staphylococcus aureus ventricular assist device mediastinitis and bacteremia
    • Swartz TH, Huprikar S, Labombardi V, et al. Heart transplantation in a patient with heteroresistant vancomycin-intermediate Staphylococcus aureus ventricular assist device mediastinitis and bacteremia. Transpl Infect Dis 2013;15:E177-81.
    • (2013) Transpl Infect Dis , vol.15 , pp. E177-E181
    • Swartz, T.H.1    Huprikar, S.2    Labombardi, V.3
  • 32
    • 84946834179 scopus 로고    scopus 로고
    • Ultraviolet Radiation Affects Thoratec HeartMate II Driveline Mechanical Properties: A Pilot Experiment
    • Evans AC, Wright GA, McCandless SP, et al. Ultraviolet Radiation Affects Thoratec HeartMate II Driveline Mechanical Properties: A Pilot Experiment. ASAIO J 2015;61:731-3.
    • (2015) ASAIO J , vol.61 , pp. 731-733
    • Evans, A.C.1    Wright, G.A.2    McCandless, S.P.3
  • 33
    • 84908143464 scopus 로고    scopus 로고
    • Drive-line infections and sepsis in patients receiving the HVAD system as a left ventricular assist device
    • John R, Aaronson KD, Pae WE, et al. Drive-line infections and sepsis in patients receiving the HVAD system as a left ventricular assist device. J Heart Lung Transplant 2014;33:1066-73.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 1066-1073
    • John, R.1    Aaronson, K.D.2    Pae, W.E.3
  • 34
    • 84872392193 scopus 로고    scopus 로고
    • Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices
    • Fleissner F, Avsar M, Malehsa D, et al. Reduction of driveline infections through doubled driveline tunneling of left ventricular assist devices. Artif Organs 2013;37:102-7.
    • (2013) Artif Organs , vol.37 , pp. 102-107
    • Fleissner, F.1    Avsar, M.2    Malehsa, D.3
  • 35
    • 84910142727 scopus 로고    scopus 로고
    • Intraoperative positioning to prevent driveline insulation from acting as a conduit for left ventricular assist device pocket infection
    • Entwistle J. Intraoperative positioning to prevent driveline insulation from acting as a conduit for left ventricular assist device pocket infection. J Thorac Cardiovasc Surg 2014;148:2437.
    • (2014) J Thorac Cardiovasc Surg , vol.148 , pp. 2437
    • Entwistle, J.1
  • 36
    • 84902440289 scopus 로고    scopus 로고
    • Driveline insulation as a conduit for left ventricular assist device pocket infection
    • Pinninti M, Thohan V, Sulemanjee NZ. Driveline insulation as a conduit for left ventricular assist device pocket infection. J Thorac Cardiovasc Surg 2014;148:e135-6.
    • (2014) J Thorac Cardiovasc Surg , vol.148 , pp. e135-e136
    • Pinninti, M.1    Thohan, V.2    Sulemanjee, N.Z.3
  • 37
    • 84930088421 scopus 로고    scopus 로고
    • Reduction in driveline infection rates: Results from the HeartMate II Multicenter Driveline Silicone Skin Interface (SSI) Registry
    • Dean D, Kallel F, Ewald GA, et al. Reduction in driveline infection rates: Results from the HeartMate II Multicenter Driveline Silicone Skin Interface (SSI) Registry. J Heart Lung Transplant 2015;34:781-9.
    • (2015) J Heart Lung Transplant , vol.34 , pp. 781-789
    • Dean, D.1    Kallel, F.2    Ewald, G.A.3
  • 38
    • 84946471645 scopus 로고    scopus 로고
    • Management of Rapidly Ascending Driveline Tunnel Infection
    • Rubinfeld G, Levine JP, Reyentovich A, et al. Management of Rapidly Ascending Driveline Tunnel Infection. J Card Surg 2015;30:853-5.
    • (2015) J Card Surg , vol.30 , pp. 853-855
    • Rubinfeld, G.1    Levine, J.P.2    Reyentovich, A.3
  • 39
    • 84929946817 scopus 로고    scopus 로고
    • Readmission due to driveline infection can be predicted by new score by using serum albumin and body mass index during longterm left ventricular assist device support
    • Imamura T, Kinugawa K, Nitta D, et al. Readmission due to driveline infection can be predicted by new score by using serum albumin and body mass index during longterm left ventricular assist device support. J Artif Organs 2015;18:120-7.
    • (2015) J Artif Organs , vol.18 , pp. 120-127
    • Imamura, T.1    Kinugawa, K.2    Nitta, D.3
  • 40
    • 84973622598 scopus 로고    scopus 로고
    • Developing a kit and video to standardize changes of left ventricular assist device dressings
    • Iseler J, Hadzic KG. Developing a kit and video to standardize changes of left ventricular assist device dressings. Prog Transplant 2015;25:224-9.
    • (2015) Prog Transplant , vol.25 , pp. 224-229
    • Iseler, J.1    Hadzic, K.G.2
  • 41
    • 84929515240 scopus 로고    scopus 로고
    • Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients
    • Wus L, Manning M, Entwistle JW 3rd. Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients. Heart Lung 2015;44:225-9.
    • (2015) Heart Lung , vol.44 , pp. 225-229
    • Wus, L.1    Manning, M.2    Entwistle, J.W.3
  • 42
    • 84948971203 scopus 로고    scopus 로고
    • Special Treatment and Wound Care of the Driveline Exit Site after Left Ventricular Assist Device Implantation
    • Menon AK, Baranski SK, Unterkofler J, et al. Special Treatment and Wound Care of the Driveline Exit Site after Left Ventricular Assist Device Implantation. Thorac Cardiovasc Surg 2015;63:670-4.
    • (2015) Thorac Cardiovasc Surg , vol.63 , pp. 670-674
    • Menon, A.K.1    Baranski, S.K.2    Unterkofler, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.