메뉴 건너뛰기




Volumn 37, Issue 1, 2013, Pages 102-107

Reduction of Driveline Infections Through Doubled Driveline Tunneling of Left Ventricular Assist Devices

Author keywords

Driveline; Infection; Left ventricular assist device; Tunneling method

Indexed keywords

FIBER OPTIC SENSORS; REGRESSION ANALYSIS;

EID: 84872392193     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/aor.12036     Document Type: Article
Times cited : (32)

References (11)
  • 1
    • 73349087519 scopus 로고    scopus 로고
    • Rise of the machines-left ventricular assist devices as permanent therapy for advanced heart failure
    • Fang JC. Rise of the machines-left ventricular assist devices as permanent therapy for advanced heart failure. N Engl J Med 2009;361:2282-2285.
    • (2009) N Engl J Med , vol.361 , pp. 2282-2285
    • Fang, J.C.1
  • 2
    • 79960563307 scopus 로고    scopus 로고
    • Mechanical circulatory support-results, developments and trends
    • Krabatsch T, Schweiger M, Stepanenko A, et al. Mechanical circulatory support-results, developments and trends. J Cardiovasc Transl Res 2011;4:332-339.
    • (2011) J Cardiovasc Transl Res , vol.4 , pp. 332-339
    • Krabatsch, T.1    Schweiger, M.2    Stepanenko, A.3
  • 3
    • 84855283097 scopus 로고    scopus 로고
    • Development and long-term in vivo testing of a novel skin-button system for preventing driveline infection of an implantable VAD system
    • Mizuno T, Nemoto Y, Tsukiya T, Takewa Y, Taenaka Y, Tatsumi E. Development and long-term in vivo testing of a novel skin-button system for preventing driveline infection of an implantable VAD system. J Artif Organs 2011;14:371-374.
    • (2011) J Artif Organs , vol.14 , pp. 371-374
    • Mizuno, T.1    Nemoto, Y.2    Tsukiya, T.3    Takewa, Y.4    Taenaka, Y.5    Tatsumi, E.6
  • 4
    • 34247557733 scopus 로고    scopus 로고
    • Infections associated with ventricular assist devices: epidemiology and effect on prognosis after transplantation
    • Monkowski DH, Axelrod P, Fekete T, Hollander T, Furukawa S, Samuel R. Infections associated with ventricular assist devices: epidemiology and effect on prognosis after transplantation. Transpl Infect Dis 2007;9:114-120.
    • (2007) Transpl Infect Dis , vol.9 , pp. 114-120
    • Monkowski, D.H.1    Axelrod, P.2    Fekete, T.3    Hollander, T.4    Furukawa, S.5    Samuel, R.6
  • 6
    • 79951771915 scopus 로고    scopus 로고
    • Minimally invasive aortic valve replacement: how does this perform in high-risk patients?
    • Schmitto JD, Mohr FW, Cohn LH. Minimally invasive aortic valve replacement: how does this perform in high-risk patients? Curr Opin Cardiol 2011;26:118-122.
    • (2011) Curr Opin Cardiol , vol.26 , pp. 118-122
    • Schmitto, J.D.1    Mohr, F.W.2    Cohn, L.H.3
  • 7
    • 84855386659 scopus 로고    scopus 로고
    • Past, present, and future of minimally invasive mitral valve surgery
    • Schmitto JD, Mokashi SA, Cohn LH. Past, present, and future of minimally invasive mitral valve surgery. J Heart Valve Dis 2011;20:493-498.
    • (2011) J Heart Valve Dis , vol.20 , pp. 493-498
    • Schmitto, J.D.1    Mokashi, S.A.2    Cohn, L.H.3
  • 8
    • 84855827670 scopus 로고    scopus 로고
    • Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: upper hemisternotomy combined with anterolateral thoracotomy
    • Schmitto JD, Molitoris U, Haverich A, Strueber M. Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: upper hemisternotomy combined with anterolateral thoracotomy. J Thorac Cardiovasc Surg 2012;143:511-513.
    • (2012) J Thorac Cardiovasc Surg , vol.143 , pp. 511-513
    • Schmitto, J.D.1    Molitoris, U.2    Haverich, A.3    Strueber, M.4
  • 9
    • 84858701740 scopus 로고    scopus 로고
    • Double tunnel technique for the LVAD driveline: improved management regarding driveline infections
    • Schibilsky D, Benk C, Haller C, et al. Double tunnel technique for the LVAD driveline: improved management regarding driveline infections. Artif Organs 2012;15:44-48.
    • (2012) Artif Organs , vol.15 , pp. 44-48
    • Schibilsky, D.1    Benk, C.2    Haller, C.3
  • 10
    • 0032711765 scopus 로고    scopus 로고
    • A novel method to reduce device-related infections in patients supported with the HeartMate device
    • Arusoglu L, Koerfer R, Tenderich G, Alexander WA, El-Banayosy A. A novel method to reduce device-related infections in patients supported with the HeartMate device. Ann Thorac Surg 1999;68:1875-1877.
    • (1999) Ann Thorac Surg , vol.68 , pp. 1875-1877
    • Arusoglu, L.1    Koerfer, R.2    Tenderich, G.3    Alexander, W.A.4    El-Banayosy, A.5
  • 11
    • 0034060818 scopus 로고    scopus 로고
    • Single-center experience with the Thoratec ventricular assist device
    • Körfer R, El-Banayosy A, Arusoglu L, et al. Single-center experience with the Thoratec ventricular assist device. J Thorac Cardiovasc Surg 2000;119:596-600.
    • (2000) J Thorac Cardiovasc Surg , vol.119 , pp. 596-600
    • Körfer, R.1    El-Banayosy, A.2    Arusoglu, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.