메뉴 건너뛰기




Volumn 31, Issue 1, 2016, Pages 76-81

High central venous-to-arterial CO2 difference/arterial-central venous O2 difference ratio is associated with poor lactate clearance in septic patients after resuscitation

Author keywords

Central venous oxygen saturation; Lactate clearance; Oxygen debt; Tissue perfusion

Indexed keywords

LACTIC ACID; NORADRENALIN; CARBON DIOXIDE;

EID: 84948823821     PISSN: 08839441     EISSN: 15578615     Source Type: Journal    
DOI: 10.1016/j.jcrc.2015.10.017     Document Type: Article
Times cited : (57)

References (34)
  • 2
    • 84878607482 scopus 로고    scopus 로고
    • Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders
    • [2] Monnet, X., Julien, F., Ait-Hamou, N., Lequoy, M., Gosset, C., Jozwiak, M., et al. Lactate and venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio, but not central venous oxygen saturation, predict increase in oxygen consumption in fluid responders. Crit Care Med 41 (2013), 1412–1420.
    • (2013) Crit Care Med , vol.41 , pp. 1412-1420
    • Monnet, X.1    Julien, F.2    Ait-Hamou, N.3    Lequoy, M.4    Gosset, C.5    Jozwiak, M.6
  • 3
    • 84926320634 scopus 로고    scopus 로고
    • Central venous-to-arterial carbon dioxide difference combined with arterial-to-venous oxygen content difference is associated with lactate evolution in the hemodynamic resuscitation process in early septic shock
    • [3] Mesquida, J., Saludes, P., Gruartmoner, G., Espinal, C., Torrents, E., Baigorri, F., et al. Central venous-to-arterial carbon dioxide difference combined with arterial-to-venous oxygen content difference is associated with lactate evolution in the hemodynamic resuscitation process in early septic shock. Crit Care, 19(1), 2015, 126.
    • (2015) Crit Care , vol.19 , Issue.1 , pp. 126
    • Mesquida, J.1    Saludes, P.2    Gruartmoner, G.3    Espinal, C.4    Torrents, E.5    Baigorri, F.6
  • 4
    • 84889250824 scopus 로고    scopus 로고
    • Meaning of the venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio
    • [4] Berthet, M., Durand, M., Meaning of the venoarterial carbon dioxide difference/arterial-venous oxygen difference ratio. Crit Care Med 41 (2013), e489–e490.
    • (2013) Crit Care Med , vol.41 , pp. e489-e490
    • Berthet, M.1    Durand, M.2
  • 5
    • 84878564864 scopus 로고    scopus 로고
    • Central venous oxygen saturation: not easily replaced
    • [5] Nguyen, H.B., Central venous oxygen saturation: not easily replaced. Crit Care Med 41 (2013), 1570–1571.
    • (2013) Crit Care Med , vol.41 , pp. 1570-1571
    • Nguyen, H.B.1
  • 6
    • 0037389094 scopus 로고    scopus 로고
    • 2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference
    • [6] Levy, M.M., Fink, M.P., Marshall, J.C., Abraham, E., Angus, D., Cook, D., et al. 2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference. Crit Care Med 31 (2003), 1250–1256.
    • (2003) Crit Care Med , vol.31 , pp. 1250-1256
    • Levy, M.M.1    Fink, M.P.2    Marshall, J.C.3    Abraham, E.4    Angus, D.5    Cook, D.6
  • 7
    • 0035829842 scopus 로고    scopus 로고
    • Early goal directed therapy in the treatment of severe sepsis and septic shock
    • [7] Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., et al. Early goal directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 345 (2001), 1368–1377.
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3    Ressler, J.4    Muzzin, A.5    Knoblich, B.6
  • 8
    • 62749095433 scopus 로고    scopus 로고
    • Central venous-to-arterial carbon dioxide difference: an additional target for goal-directed therapy in septic shock?
    • [8] Vallée, F., Vallet, B., Mathe, O., Parraguette, J., Mari, A., Silva, S., et al. Central venous-to-arterial carbon dioxide difference: an additional target for goal-directed therapy in septic shock?. Intensive Care Med 34 (2008), 2218–2225.
    • (2008) Intensive Care Med , vol.34 , pp. 2218-2225
    • Vallée, F.1    Vallet, B.2    Mathe, O.3    Parraguette, J.4    Mari, A.5    Silva, S.6
  • 9
  • 10
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • [10] Hanley, J.A., McNeil, B.J., The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 43 (1982), 29–36.
    • (1982) Radiology , vol.43 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 11
    • 77649088003 scopus 로고    scopus 로고
    • Assessing shock resuscitation strategies by oxygen debt repayment
    • [11] Barbee, R.W., Reynolds, P.S., Ward, K.R., Assessing shock resuscitation strategies by oxygen debt repayment. Shock 33 (2010), 113–122.
    • (2010) Shock , vol.33 , pp. 113-122
    • Barbee, R.W.1    Reynolds, P.S.2    Ward, K.R.3
  • 12
    • 11144279379 scopus 로고    scopus 로고
    • Oxygen transport—the oxygen delivery controversy
    • [12] Vincent, J.L., DeBacker, D., Oxygen transport—the oxygen delivery controversy. Intensive Care Med 30 (2004), 1990–1996.
    • (2004) Intensive Care Med , vol.30 , pp. 1990-1996
    • Vincent, J.L.1    DeBacker, D.2
  • 13
    • 77249162677 scopus 로고    scopus 로고
    • Lactate clearance vs. central venous oxygen saturation as goals of early sepsis therapy: a randomized clinical trial
    • [13] Jones, A.E., Shapiro, N.I., Trzeciak, S., Arnold, R.C., Claremont, H.A., Kline, J.A., et al. Lactate clearance vs. central venous oxygen saturation as goals of early sepsis therapy: a randomized clinical trial. JAMA 303 (2010), 739–746.
    • (2010) JAMA , vol.303 , pp. 739-746
    • Jones, A.E.1    Shapiro, N.I.2    Trzeciak, S.3    Arnold, R.C.4    Claremont, H.A.5    Kline, J.A.6
  • 16
    • 0025735897 scopus 로고
    • Blood lactate levels are superior to oxygen derived variables in predicting outcome in human septic shock
    • [16] Bakker, J., Coffernils, M., Leon, M., Gris, P., Vincent, J.L., Blood lactate levels are superior to oxygen derived variables in predicting outcome in human septic shock. Chest 99 (1991), 956–962.
    • (1991) Chest , vol.99 , pp. 956-962
    • Bakker, J.1    Coffernils, M.2    Leon, M.3    Gris, P.4    Vincent, J.L.5
  • 17
    • 84906791087 scopus 로고    scopus 로고
    • Lactate clearance is a useful biomarker for the prediction of all-cause mortality in critically ill patients: a systematic review and meta-analysis
    • [17] Zhang, Z., Xu, X., Lactate clearance is a useful biomarker for the prediction of all-cause mortality in critically ill patients: a systematic review and meta-analysis. Crit Care Med 42 (2014), 2118–2125.
    • (2014) Crit Care Med , vol.42 , pp. 2118-2125
    • Zhang, Z.1    Xu, X.2
  • 18
    • 84870198838 scopus 로고    scopus 로고
    • Prognostic significance of blood lactate and lactate clearance in trauma patients
    • [18] Régnier, M.A., Raux, M., Le Manach, Y., Asencio, Y., Gaillard, J., Devilliers, C., et al. Prognostic significance of blood lactate and lactate clearance in trauma patients. Anesthesiology 117 (2012), 1276–1288.
    • (2012) Anesthesiology , vol.117 , pp. 1276-1288
    • Régnier, M.A.1    Raux, M.2    Le Manach, Y.3    Asencio, Y.4    Gaillard, J.5    Devilliers, C.6
  • 19
    • 35348925021 scopus 로고    scopus 로고
    • A comparison of central venous-arterial and mixed venous-arterial carbon dioxide tension gradient in circulatory failure
    • [19] Ho, K.M., Harding, R., Chamberlain, J., A comparison of central venous-arterial and mixed venous-arterial carbon dioxide tension gradient in circulatory failure. Anaesth Intensive Care 35 (2007), 695–701.
    • (2007) Anaesth Intensive Care , vol.35 , pp. 695-701
    • Ho, K.M.1    Harding, R.2    Chamberlain, J.3
  • 20
    • 10444279213 scopus 로고    scopus 로고
    • Lack of equivalence between central and mixed venous oxygen saturation
    • [20] Chawla, L.S., Zia, H., Gutierrez, G., Katz, N.M., Seneff, M.G., Shah, M., Lack of equivalence between central and mixed venous oxygen saturation. Chest 126 (2004), 1891–1896.
    • (2004) Chest , vol.126 , pp. 1891-1896
    • Chawla, L.S.1    Zia, H.2    Gutierrez, G.3    Katz, N.M.4    Seneff, M.G.5    Shah, M.6
  • 21
    • 0031904641 scopus 로고    scopus 로고
    • Importance of the sampling site for measurement of mixed venous oxygen saturation in shock
    • [21] Edwards, J.D., Mayall, R.M., Importance of the sampling site for measurement of mixed venous oxygen saturation in shock. Crit Care Med 26 (1998), 1356–1360.
    • (1998) Crit Care Med , vol.26 , pp. 1356-1360
    • Edwards, J.D.1    Mayall, R.M.2
  • 22
    • 0026720548 scopus 로고
    • Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients
    • [22] Martin, C., Auffray, J.P., Badetti, C., Perrin, G., Papazian, L., Gouin, F., Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients. Intensive Care Med 18 (1992), 101–104.
    • (1992) Intensive Care Med , vol.18 , pp. 101-104
    • Martin, C.1    Auffray, J.P.2    Badetti, C.3    Perrin, G.4    Papazian, L.5    Gouin, F.6
  • 23
    • 0022963166 scopus 로고
    • Can central-venous replace mixed-venous oxygen saturation measurements during anesthesia?
    • [23] Reinhart, K., Kersting, T., Fohring, U., Schafer, M., Can central-venous replace mixed-venous oxygen saturation measurements during anesthesia?. Adv Exp Med Biol 200 (1986), 67–72.
    • (1986) Adv Exp Med Biol , vol.200 , pp. 67-72
    • Reinhart, K.1    Kersting, T.2    Fohring, U.3    Schafer, M.4
  • 24
    • 0033533116 scopus 로고    scopus 로고
    • Lactate is an unreliable indicator of tissue hypoxia in injury or sepsis
    • [24] James, J.H., Luchette, F.A., McCarter, F.D., Fischer, J.E., Lactate is an unreliable indicator of tissue hypoxia in injury or sepsis. Lancet 354 (1999), 505–508.
    • (1999) Lancet , vol.354 , pp. 505-508
    • James, J.H.1    Luchette, F.A.2    McCarter, F.D.3    Fischer, J.E.4
  • 25
    • 0031968240 scopus 로고    scopus 로고
    • Mild hyperlactatemia in stable septic patients is due to impaired lactate clearance rather than overproduction
    • [25] Levraut, J., Ciebiera, J.P., Chave, S., Rabary, O., Jambou, P., Carles, M., et al. Mild hyperlactatemia in stable septic patients is due to impaired lactate clearance rather than overproduction. Am J Respir Crit Care Med 157 (1998), 1021–1026.
    • (1998) Am J Respir Crit Care Med , vol.157 , pp. 1021-1026
    • Levraut, J.1    Ciebiera, J.P.2    Chave, S.3    Rabary, O.4    Jambou, P.5    Carles, M.6
  • 28
    • 84889980239 scopus 로고    scopus 로고
    • Persistently high venous-to-arterial carbon dioxide differences during early resuscitation are associated with poor outcomes in septic shock
    • [28] Ospina-Tascόn, G.A., Bautista-Rincόn, D.F., Umaña, M., Tafur, J.D., Gutiérrez, A., Garcıía, A.F., et al. Persistently high venous-to-arterial carbon dioxide differences during early resuscitation are associated with poor outcomes in septic shock. Crit Care, 17, 2013, R294.
    • (2013) Crit Care , vol.17 , pp. R294
    • Ospina-Tascόn, G.A.1    Bautista-Rincόn, D.F.2    Umaña, M.3    Tafur, J.D.4    Gutiérrez, A.5    Garcıía, A.F.6
  • 32
    • 84868321045 scopus 로고    scopus 로고
    • Hemodynamic management of cardiovascular failure by using PCO(2) venous-arterial difference
    • [32] Dres, M., Monnet, X., Teboul, J.L., Hemodynamic management of cardiovascular failure by using PCO(2) venous-arterial difference. J Clin Monit Comput 26 (2012), 367–374.
    • (2012) J Clin Monit Comput , vol.26 , pp. 367-374
    • Dres, M.1    Monnet, X.2    Teboul, J.L.3
  • 33
    • 35548993658 scopus 로고    scopus 로고
    • Point of care hematocrit and hemoglobin in cardiac surgery: a review
    • [33] Myers, Gerard J., Browne, Joe, Point of care hematocrit and hemoglobin in cardiac surgery: a review. Perfusion 22 (2007), 179–183.
    • (2007) Perfusion , vol.22 , pp. 179-183
    • Myers, G.J.1    Browne, J.2
  • 34
    • 84155189164 scopus 로고    scopus 로고
    • Accuracy and precision of hemoglobin point-of-care testing during major pediatric surgery
    • [34] Spielmann, N., Mauch, J., Madjdpour, C., Schmugge, M., Weiss, M., Haas, T., Accuracy and precision of hemoglobin point-of-care testing during major pediatric surgery. Int J Lab Hematol 34 (2012), 86–90.
    • (2012) Int J Lab Hematol , vol.34 , pp. 86-90
    • Spielmann, N.1    Mauch, J.2    Madjdpour, C.3    Schmugge, M.4    Weiss, M.5    Haas, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.