메뉴 건너뛰기




Volumn 19, Issue 1, 2015, Pages

Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AORTIC VELOCITY TIME INTEGRAL; ARTICLE; BREATHING; CARDIOVASCULAR PARAMETERS; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; ECHOCARDIOGRAPHY; FEMALE; FLUID THERAPY; HEART OUTPUT; HEART STROKE VOLUME; HUMAN; HYPOVOLEMIA; INFERIOR VENA CAVA COLLAPSIBILITY INDEX; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ACCURACY; PREDICTIVE VALUE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; TREATMENT RESPONSE; AGED; BLOOD; DIAGNOSTIC IMAGING; ECHOGRAPHY; HYDRODYNAMICS; INFERIOR CAVA VEIN; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; PROCEDURES; RESPIRATORY FUNCTION;

EID: 84946820756     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/s13054-015-1100-9     Document Type: Article
Times cited : (163)

References (34)
  • 1
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121(6):2000-8.
    • (2002) Chest , vol.121 , Issue.6 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 2
    • 37549020378 scopus 로고    scopus 로고
    • Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008
    • Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008. Crit Care Med. 2008;36:296-327.
    • (2008) Crit Care Med. , vol.36 , pp. 296-327
    • Dellinger, R.P.1    Levy, M.M.2    Carlet, J.M.3    Bion, J.4    Parker, M.M.5    Jaeschke, R.6
  • 3
    • 0034087866 scopus 로고    scopus 로고
    • Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study
    • Alsous F, Khamiees M, DeGirolamo A, Amoateng-Adjepong Y, Manthous CA. Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study. Chest. 2000;117:1749-54.
    • (2000) Chest. , vol.117 , pp. 1749-1754
    • Alsous, F.1    Khamiees, M.2    DeGirolamo, A.3    Amoateng-Adjepong, Y.4    Manthous, C.A.5
  • 4
    • 33745081608 scopus 로고    scopus 로고
    • Comparison of two fluid-management strategies in acute lung injury
    • National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network, Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, et al. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006;354(24):2564-75.
    • (2006) N Engl J Med , vol.354 , Issue.24 , pp. 2564-2575
    • Wiedemann, H.P.1    Wheeler, A.P.2    Bernard, G.R.3    Thompson, B.T.4    Hayden, D.5
  • 6
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001;119(3):867-73.
    • (2001) Chest , vol.119 , Issue.3 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3    Ruyer, O.4    Faller, J.P.5    Teboul, J.L.6
  • 7
    • 84055160934 scopus 로고    scopus 로고
    • Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance
    • Monnet X, Bleibtreu A, Ferré A, Dres M, Gharbi R, Richard C, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012;40(1):152-7.
    • (2012) Crit Care Med , vol.40 , Issue.1 , pp. 152-157
    • Monnet, X.1    Bleibtreu, A.2    Ferré, A.3    Dres, M.4    Gharbi, R.5    Richard, C.6
  • 8
    • 33845958648 scopus 로고    scopus 로고
    • Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
    • Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35(1):64-8.
    • (2007) Crit Care Med , vol.35 , Issue.1 , pp. 64-68
    • Osman, D.1    Ridel, C.2    Ray, P.3    Monnet, X.4    Anguel, N.5    Richard, C.6
  • 9
    • 58749115378 scopus 로고    scopus 로고
    • Inferior vena cava diameter (IVCD) measured with transesophageal echocardiography (TEE) can be used to derive the central venous pressure (CVP) in anesthetized mechanically ventilated patients
    • Arthur ME, Landolfo C, Wade M, Castresana MR. Inferior vena cava diameter (IVCD) measured with transesophageal echocardiography (TEE) can be used to derive the central venous pressure (CVP) in anesthetized mechanically ventilated patients. Echocardiography. 2009;26(2):140-9.
    • (2009) Echocardiography , vol.26 , Issue.2 , pp. 140-149
    • Arthur, M.E.1    Landolfo, C.2    Wade, M.3    Castresana, M.R.4
  • 10
    • 0026952317 scopus 로고
    • Does inferior vena cava size predict right atrial pressures in patients receiving mechanical ventilation?
    • Jue J, Chung W, Schiller NB. Does inferior vena cava size predict right atrial pressures in patients receiving mechanical ventilation? J Am Soc Echocardiogr. 1992;5(6):613-9.
    • (1992) J Am Soc Echocardiogr , vol.5 , Issue.6 , pp. 613-619
    • Jue, J.1    Chung, W.2    Schiller, N.B.3
  • 11
    • 0036739873 scopus 로고    scopus 로고
    • Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated
    • Bendjelid K, Romand JA, Walder B, Suter PM, Fournier G. Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated. J Am Soc Echocardiogr. 2002;15(9):944-9.
    • (2002) J Am Soc Echocardiogr , vol.15 , Issue.9 , pp. 944-949
    • Bendjelid, K.1    Romand, J.A.2    Walder, B.3    Suter, P.M.4    Fournier, G.5
  • 12
    • 2542457136 scopus 로고    scopus 로고
    • The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
    • Feissel M, Michard F, Faller JP, Teboul JL. The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med. 2004;30(9):1834-7.
    • (2004) Intensive Care Med , vol.30 , Issue.9 , pp. 1834-1837
    • Feissel, M.1    Michard, F.2    Faller, J.P.3    Teboul, J.L.4
  • 13
    • 4644226589 scopus 로고    scopus 로고
    • Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients
    • Barbier C, Loubières Y, Schmit C, Hayon J, Ricôme JL, Jardin F, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med. 2004;30(9):1740-6.
    • (2004) Intensive Care Med , vol.30 , Issue.9 , pp. 1740-1746
    • Barbier, C.1    Loubières, Y.2    Schmit, C.3    Hayon, J.4    Ricôme, J.L.5    Jardin, F.6
  • 14
    • 84867054087 scopus 로고    scopus 로고
    • Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use
    • Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B, et al. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012;16(5):R188.
    • (2012) Crit Care , vol.16 , Issue.5 , pp. R188
    • Muller, L.1    Bobbia, X.2    Toumi, M.3    Louart, G.4    Molinari, N.5    Ragonnet, B.6
  • 15
    • 43449086396 scopus 로고    scopus 로고
    • Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity
    • Teboul JL, Monnet X. Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity. Curr Opin Crit Care. 2008;14(3):334-9.
    • (2008) Curr Opin Crit Care , vol.14 , Issue.3 , pp. 334-339
    • Teboul, J.L.1    Monnet, X.2
  • 17
    • 79954628474 scopus 로고    scopus 로고
    • International expert statement on training standards for critical care ultrasonography
    • Expert Round Table on Ultrasound in ICU. International expert statement on training standards for critical care ultrasonography. Intensive Care Med. 2011;37(7):1077-83.
    • (2011) Intensive Care Med , vol.37 , Issue.7 , pp. 1077-1083
  • 18
    • 64749098476 scopus 로고    scopus 로고
    • American College of Chest Physicians/La Société de Réanimation de Langue Française statement on competence in critical care ultrasonography
    • Mayo PH, Beaulieu Y, Doelken P, Feller-Kopman D, Harrod C, Kaplan A, et al. American College of Chest Physicians/La Société de Réanimation de Langue Française statement on competence in critical care ultrasonography. Chest. 2009;135(4):1050-60.
    • (2009) Chest , vol.135 , Issue.4 , pp. 1050-1060
    • Mayo, P.H.1    Beaulieu, Y.2    Doelken, P.3    Feller-Kopman, D.4    Harrod, C.5    Kaplan, A.6
  • 19
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a Branch of the European Society of Cardiology
    • Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, et al. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a Branch of the European Society of Cardiology. J Am Soc Echocardiogr. 2005;18(12):1440-63.
    • (2005) J Am Soc Echocardiogr , vol.18 , Issue.12 , pp. 1440-1463
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3    Flachskampf, F.A.4    Foster, E.5    Pellikka, P.A.6
  • 20
    • 0031678867 scopus 로고    scopus 로고
    • Echocardiography of the inferior vena cava, superior vena cava, and coronary sinus in right heart failure
    • Shala MB, D'Cruz IA, Johns C, Kaiser J, Clark R. Echocardiography of the inferior vena cava, superior vena cava, and coronary sinus in right heart failure. Echocardiography. 1998;15(8):787-94.
    • (1998) Echocardiography , vol.15 , Issue.8 , pp. 787-794
    • Shala, M.B.1    D'Cruz, I.A.2    Johns, C.3    Kaiser, J.4    Clark, R.5
  • 21
    • 0030004825 scopus 로고    scopus 로고
    • Relation of mean right atrial pressure to echocardiographic and Doppler parameters of right atrial and right ventricular function
    • Nagueh SF, Kopelen HA, Zoghbi WA. Relation of mean right atrial pressure to echocardiographic and Doppler parameters of right atrial and right ventricular function. Circulation. 1996;93:1160-9.
    • (1996) Circulation. , vol.93 , pp. 1160-1169
    • Nagueh, S.F.1    Kopelen, H.A.2    Zoghbi, W.A.3
  • 22
    • 0023263501 scopus 로고
    • Effects of positional changes on inferior vena caval size and dynamics and correlations with right-sided cardiac pressure
    • Nakao S, Come PC, McKay RG, Ransil BJ. Effects of positional changes on inferior vena caval size and dynamics and correlations with right-sided cardiac pressure. Am J Cardiol. 1987;59(1):125-32.
    • (1987) Am J Cardiol , vol.59 , Issue.1 , pp. 125-132
    • Nakao, S.1    Come, P.C.2    McKay, R.G.3    Ransil, B.J.4
  • 23
    • 0021321966 scopus 로고
    • Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac function
    • Moreno FL, Hagan AD, Holmen JR, Pryor TA, Strickland RD, Castle CH. Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac function. Am J Cardiol. 1984;53(4):579-85.
    • (1984) Am J Cardiol , vol.53 , Issue.4 , pp. 579-585
    • Moreno, F.L.1    Hagan, A.D.2    Holmen, J.R.3    Pryor, T.A.4    Strickland, R.D.5    Castle, C.H.6
  • 24
    • 0019390527 scopus 로고
    • Real-time inferior vena caval ultrasonography: normal and abnormal findings and its use in assessing right-heart function
    • Mintz GS, Kotler MN, Parry WR, Iskandrian AS, Kane SA. Real-time inferior vena caval ultrasonography: normal and abnormal findings and its use in assessing right-heart function. Circulation. 1981;64(5):1018-25.
    • (1981) Circulation , vol.64 , Issue.5 , pp. 1018-1025
    • Mintz, G.S.1    Kotler, M.N.2    Parry, W.R.3    Iskandrian, A.S.4    Kane, S.A.5
  • 25
    • 0021014880 scopus 로고
    • Effect of inspiration on inferior vena caval blood flow in dogs
    • Lloyd Jr TC. Effect of inspiration on inferior vena caval blood flow in dogs. J Appl Physiol. 1983;55(6):1701-8.
    • (1983) J Appl Physiol , vol.55 , Issue.6 , pp. 1701-1708
    • Lloyd, T.C.1
  • 26
    • 0025102102 scopus 로고
    • Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava
    • Kircher BJ, Himelman RB, Schiller NB. Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. Am J Cardiol. 1990;66(4):493-6.
    • (1990) Am J Cardiol , vol.66 , Issue.4 , pp. 493-496
    • Kircher, B.J.1    Himelman, R.B.2    Schiller, N.B.3
  • 27
    • 85047680453 scopus 로고
    • Venous collapse and the respiratory variability in systemic venous return
    • Amoore JN, Santamore WP. Venous collapse and the respiratory variability in systemic venous return. Cardiovasc Res. 1994;28:472-9.
    • (1994) Cardiovasc Res. , vol.28 , pp. 472-479
    • Amoore, J.N.1    Santamore, W.P.2
  • 28
    • 67349286164 scopus 로고    scopus 로고
    • Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: correlations with CVP
    • Stawicki SP, Braslow BM, Panebianco NL, Kirkpatrick JN, Gracias VH, Hayden GE et al. Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: correlations with CVP. J Am Coll Surg. 2009;209(1):55-61.
    • (2009) J Am Coll Surg , vol.209 , Issue.1 , pp. 55-61
    • Stawicki, S.P.1    Braslow, B.M.2    Panebianco, N.L.3    Kirkpatrick, J.N.4    Gracias, V.H.5    Hayden, G.E.6
  • 30
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134(1):172-8.
    • (2008) Chest , vol.134 , Issue.1 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 33
    • 84855533948 scopus 로고    scopus 로고
    • Hemodynamic changes during a deep inspiration maneuver predict fluid responsiveness in spontaneously breathing patients
    • Préau S, Dewavrin F, Soland V, Bortolotti P, Colling D, Chagnon JL et al. Hemodynamic changes during a deep inspiration maneuver predict fluid responsiveness in spontaneously breathing patients. Cardiol Res Pract. 2012;2012:191807.
    • (2012) Cardiol Res Pract. , vol.2012 , pp. 191807
    • Préau, S.1    Dewavrin, F.2    Soland, V.3    Bortolotti, P.4    Colling, D.5    Chagnon, J.L.6
  • 34
    • 84866108994 scopus 로고    scopus 로고
    • Can transthoracic echocardiography be used to predict fluid responsiveness in the critically ill patient? A systematic review
    • Mandeville JC, Colebourn CL. Can transthoracic echocardiography be used to predict fluid responsiveness in the critically ill patient? A systematic review. Crit Care Res Pract. 2012;2012:513480.
    • (2012) Crit Care Res Pract. , vol.2012 , pp. 513480
    • Mandeville, J.C.1    Colebourn, C.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.