-
1
-
-
80755148728
-
Artificial pancreas: Past, present, future
-
Cobelli C, Renard E, Kovatchev BP: Artificial pancreas: past, present, future. Diabetes 2011;60:2672-2682.
-
(2011)
Diabetes
, vol.60
, pp. 2672-2682
-
-
Cobelli, C.1
Renard, E.2
Kovatchev, B.P.3
-
2
-
-
84898444019
-
The artificial pancreas: Current status and future prospects in the management of diabetes
-
Peyser T, Dassau E, Breton M, et al.: The artificial pancreas: current status and future prospects in the management of diabetes. Ann N Y Acad Sci 2014;1311:102-123.
-
(2014)
Ann N Y Acad Sci
, vol.1311
, pp. 102-123
-
-
Peyser, T.1
Dassau, E.2
Breton, M.3
-
3
-
-
84891821449
-
Time lag of glucose from intravascular to interstitial compartment in humans
-
Basu A, Dube S, Slama M, et al.: Time lag of glucose from intravascular to interstitial compartment in humans. Diabetes 2013;62:4083-4087.
-
(2013)
Diabetes
, vol.62
, pp. 4083-4087
-
-
Basu, A.1
Dube, S.2
Slama, M.3
-
4
-
-
84940933110
-
Time lag of glucose from intravascular to interstitial compartment in type 1 diabetes
-
Basu A, Dube A, Veettil S, et al.: Time lag of glucose from intravascular to interstitial compartment in type 1 diabetes. J Diabetes Sci Technol 2015;9:63-68.
-
(2015)
J Diabetes Sci Technol
, vol.9
, pp. 63-68
-
-
Basu, A.1
Dube, A.2
Veettil, S.3
-
5
-
-
0031257640
-
Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
-
Bantle JP, Thomas W: Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid. J Lab Clin Med 1997;130:436-441.
-
(1997)
J Lab Clin Med
, vol.130
, pp. 436-441
-
-
Bantle, J.P.1
Thomas, W.2
-
6
-
-
0030003565
-
Does fall in tissue glucose precede fall in blood glucose?
-
Sternberg F, Meyerhoff C, Mennel FJ, et al.: Does fall in tissue glucose precede fall in blood glucose? Diabetologia 1996;39:609-612.
-
(1996)
Diabetologia
, vol.39
, pp. 609-612
-
-
Sternberg, F.1
Meyerhoff, C.2
Mennel, F.J.3
-
7
-
-
0027474090
-
On line glucose monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis
-
Pfeiffer EF, Meyerhoff F, Bischof F, et al.: On line glucose monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis. Horm Metab Res 1993;25:121-124.
-
(1993)
Horm Metab Res
, vol.25
, pp. 121-124
-
-
Pfeiffer, E.F.1
Meyerhoff, F.2
Bischof, F.3
-
8
-
-
0035715516
-
Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers
-
Wientjes KJ, Schoonen AJ: Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers. Int J Artif Organs 2001;24:884-889.
-
(2001)
Int J Artif Organs
, vol.24
, pp. 884-889
-
-
Wientjes, K.J.1
Schoonen, A.J.2
-
9
-
-
0042804817
-
Assessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue
-
Regittnig W, Ellmerer M, Fauler G, et al.: Assessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue. Am J Physiol Endocrinol Metab 2003;285:E241-E251.
-
(2003)
Am J Physiol Endocrinol Metab
, vol.285
, pp. E241-E251
-
-
Regittnig, W.1
Ellmerer, M.2
Fauler, G.3
-
10
-
-
6944240518
-
Interstitial glucose kinetics in subjects with type 1 diabetes under physiologic conditions
-
Wilinska ME, Bodenlenz M, Chassin LJ, et al.: Interstitial glucose kinetics in subjects with type 1 diabetes under physiologic conditions. Metabolism 2004;53:1484-1491.
-
(2004)
Metabolism
, vol.53
, pp. 1484-1491
-
-
Wilinska, M.E.1
Bodenlenz, M.2
Chassin, L.J.3
-
11
-
-
0024541965
-
In vivo molecular sensing in diabetes mellitus: An implantable glucose sensor with direct electron transfer
-
Pickup JC, Shaw GW, Claremont DJ: In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia 1989;32:213-217.
-
(1989)
Diabetologia
, vol.32
, pp. 213-217
-
-
Pickup, J.C.1
Shaw, G.W.2
Claremont, D.J.3
-
12
-
-
0032836714
-
Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
-
Rebrin K, Steil GM, Van Antwerp WP, et al.: Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol 1999;277:E561-E571.
-
(1999)
Am J Physiol
, vol.277
, pp. E561-E571
-
-
Rebrin, K.1
Steil, G.M.2
Van Antwerp, W.P.3
-
13
-
-
0242300559
-
Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
-
Boyne MS, Silver DM, Kaplan J, et al.: Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes 2003;52:2790-2794.
-
(2003)
Diabetes
, vol.52
, pp. 2790-2794
-
-
Boyne, M.S.1
Silver, D.M.2
Kaplan, J.3
-
14
-
-
24944495481
-
Interstitial fluid glucose dynamics during insulin-induced hypoglycemia
-
Steil GM, Rebrin K, Hariri F, et al.: Interstitial fluid glucose dynamics during insulin-induced hypoglycemia. Diabetologia 2005;48:1833-1840.
-
(2005)
Diabetologia
, vol.48
, pp. 1833-1840
-
-
Steil, G.M.1
Rebrin, K.2
Hariri, F.3
-
15
-
-
70449688342
-
Analysis of time lags and other sources of error of the DexCom SEVEN continuous glucose monitor
-
Kamath A, Mahalingam A, Brauker J: Analysis of time lags and other sources of error of the DexCom SEVEN continuous glucose monitor. Diabetes Technol Ther 2009;11:689-695.
-
(2009)
Diabetes Technol Ther
, vol.11
, pp. 689-695
-
-
Kamath, A.1
Mahalingam, A.2
Brauker, J.3
-
16
-
-
84881553093
-
Who needs an artificial pancreas?
-
Winikoff J, Drexler A: Who needs an artificial pancreas? J Diabetes 2013;5:254-257.
-
(2013)
J Diabetes
, vol.5
, pp. 254-257
-
-
Winikoff, J.1
Drexler, A.2
-
17
-
-
79952201180
-
Use of subcutaneous interstitial fluid glucose to estimate blood glucose: Revisiting delay and sensor offset
-
Rebrin K, Sheppard NF Jr, Steil GM: Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset. J Diabetes Sci Technol 2010;4:1087-1098.
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 1087-1098
-
-
Rebrin, K.1
Sheppard, N.F.2
Steil, G.M.3
-
18
-
-
0026452076
-
Microdialysis measurement of the absolute glucose concentration in subcutaneous adipose tissue allowing glucose monitoring in diabetic patients
-
Bolinder J, Ungerstedt U, Arner P: Microdialysis measurement of the absolute glucose concentration in subcutaneous adipose tissue allowing glucose monitoring in diabetic patients. Diabetologia 1992;35:1177-1180.
-
(1992)
Diabetologia
, vol.35
, pp. 1177-1180
-
-
Bolinder, J.1
Ungerstedt, U.2
Arner, P.3
-
19
-
-
0027425609
-
Long-term continuous glucose monitoring with microdialysis in ambulatory insulin-dependent diabetic patients
-
Bolinder J, Ungerstedt U, Arner P: Long-term continuous glucose monitoring with microdialysis in ambulatory insulin-dependent diabetic patients. Lancet 1993;342:1080-1085.
-
(1993)
Lancet
, vol.342
, pp. 1080-1085
-
-
Bolinder, J.1
Ungerstedt, U.2
Arner, P.3
-
20
-
-
0026769254
-
Tracer-to-tracee ratio for analysis of stable isotope tracer data: Link with radioactive kinetic formalism
-
Cobelli C, Toffolo GM, Foster DM: Tracer-to-tracee ratio for analysis of stable isotope tracer data: link with radioactive kinetic formalism. Am J Physiol 1992;262:E968-E974.
-
(1992)
Am J Physiol
, vol.262
, pp. E968-E974
-
-
Cobelli, C.1
Toffolo, G.M.2
Foster, D.M.3
-
24
-
-
34247600583
-
Accuracy of the 5-Day FreeStyle Navigator continuous glucose monitoring system
-
Weinstein RL, Schwartz SL, Brazg RL, et al.: Accuracy of the 5-Day FreeStyle Navigator continuous glucose monitoring system. Diabetes Care 2007;30:1125-130.
-
(2007)
Diabetes Care
, vol.30
, pp. 1125-1130
-
-
Weinstein, R.L.1
Schwartz, S.L.2
Brazg, R.L.3
-
25
-
-
0034004142
-
Interstitial glucose concentration and glycemia: Implications for continuous subcutaneous glucose monitoring
-
Aussedat B, Dupire-Angel M, Gifford R, et al.: Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring. Am J Physiol Endocrinol Metab 2000;278:E716-E728.
-
(2000)
Am J Physiol Endocrinol Metab
, vol.278
, pp. E716-E728
-
-
Aussedat, B.1
Dupire-Angel, M.2
Gifford, R.3
|