메뉴 건너뛰기




Volumn 153, Issue 5, 2015, Pages 838-842

Erratum: Accuracy of a tablet audiometer for measuring behavioral hearing thresholds in a clinical population (Otolaryngology - Head and Neck Surgery (United States) (2015) 153 (838-842) DOI: 10.1177/0194599815593737);Accuracy of a Tablet Audiometer for Measuring Behavioral Hearing Thresholds in a Clinical Population

Author keywords

audiometrics; automated; hearing thresholds; reliability

Indexed keywords

ACOUSTICS; ADULT; AGED; ARTICLE; AUDIOMETER; AUDIOMETRY; AUDITORY THRESHOLD; CHILD; CLINICAL ARTICLE; COHORT ANALYSIS; HEARING ACUITY; HEARING TEST; HUMAN; MEASUREMENT ACCURACY; MEASUREMENT ERROR; MIDDLE AGED; NOISE; POPULATION; PROSPECTIVE STUDY; SOUND LEVEL METER; TABLET AUDIOMETER; TERTIARY CARE CENTER; ADOLESCENT; DEVICES; EQUIPMENT DESIGN; FEMALE; FOLLOW UP; HEARING; HEARING LOSS; MALE; MICROCOMPUTER; PATHOPHYSIOLOGY; PHYSIOLOGY; PRESCHOOL CHILD; PURE TONE AUDIOMETRY; REPRODUCIBILITY; VERY ELDERLY; YOUNG ADULT;

EID: 84946088268     PISSN: 01945998     EISSN: 10976817     Source Type: Journal    
DOI: 10.1177/0194599815623266     Document Type: Erratum
Times cited : (71)

References (10)
  • 1
    • 0003837144 scopus 로고    scopus 로고
    • American National Standards Institute. Rev ed. New York, NY: American National Standards Institute; ANSI S3.1-1999
    • American National Standards Institute. Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms. Rev ed. New York, NY: American National Standards Institute; 2003. ANSI S3.1-1999.
    • (2003) Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms
  • 2
    • 39149083239 scopus 로고    scopus 로고
    • American National Standards Institute. New York, NY: American National Standards Institute; ANSI S3.21-2004
    • American National Standards Institute. Methods for Manual Pure-Tone Threshold Audiometry. New York, NY: American National Standards Institute; 2004. ANSI S3.21-2004.
    • (2004) Methods for Manual Pure-Tone Threshold Audiometry
  • 3
    • 0003866520 scopus 로고    scopus 로고
    • American National Standards Institute. New York, NY: American National Standards Institute; ANSI S3.6-2004
    • American National Standards Institute. Specifications for Audiometers. New York, NY: American National Standards Institute; 2004. ANSI S3.6-2004.
    • (2004) Specifications for Audiometers
  • 4
    • 84887306996 scopus 로고    scopus 로고
    • Validity of automated threshold audiometry: A systematic review and meta-analysis
    • [published online 31, ]
    • Mahomed F, Swanepoel DW, Eikelboom RH, Soer M., Validity of automated threshold audiometry: a systematic review and meta-analysis. [published online 31, 2013 ]. Ear Hear.
    • (2013) Ear Hear
    • Mahomed, F.1    Swanepoel, D.W.2    Eikelboom, R.H.3    Soer, M.4
  • 5
    • 84896982593 scopus 로고    scopus 로고
    • The new age of play audiometry: Prospective validation testing of an iPad-based play audiometer
    • Yeung J, Javidia H, Heley S, et al. The new age of play audiometry: prospective validation testing of an iPad-based play audiometer. J Otolaryngol Head Neck Surg. 2013; 42: 21-28.
    • (2013) J Otolaryngol Head Neck Surg , vol.42 , pp. 21-28
    • Yeung, J.1    Javidia, H.2    Heley, S.3
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG., Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 84887432743 scopus 로고    scopus 로고
    • Automated audiometry using Apple iOS-based application technology
    • Foulad A, Bui P, Djalilian H., Automated audiometry using Apple iOS-based application technology. J Otolaryngol Head Neck Surg. 2013; 149: 700-706.
    • (2013) J Otolaryngol Head Neck Surg , vol.149 , pp. 700-706
    • Foulad, A.1    Bui, P.2    Djalilian, H.3
  • 8
    • 0037021730 scopus 로고    scopus 로고
    • Interpretation of pure-tone threshold in sensorineural hearing loss (SNHL): A review of measurement variability and age-specific references
    • Lemkens N, Vermeire K, Brokx JP, et al. Interpretation of pure-tone threshold in sensorineural hearing loss (SNHL): a review of measurement variability and age-specific references. Acta Otorhinolaryngol Belg. 2002; 56: 341-352.
    • (2002) Acta Otorhinolaryngol Belg , vol.56 , pp. 341-352
    • Lemkens, N.1    Vermeire, K.2    Brokx, J.P.3
  • 9
    • 70349754631 scopus 로고    scopus 로고
    • Computer assisted audiometry versus manual audiometry
    • Ho AT, Hildreth AJ, Lindsey L., Computer assisted audiometry versus manual audiometry. Am J Otol. 2009; 30: 876-883.
    • (2009) Am J Otol , vol.30 , pp. 876-883
    • Ho, A.T.1    Hildreth, A.J.2    Lindsey, L.3
  • 10
    • 84907057897 scopus 로고    scopus 로고
    • Ambient noise impact on accuracy of automated hearing assessment
    • Storey KK, Munoz K, Nelson L, Larsen J, White K., Ambient noise impact on accuracy of automated hearing assessment. Int J Audiol. 2014; 53: 730-736.
    • (2014) Int J Audiol , vol.53 , pp. 730-736
    • Storey, K.K.1    Munoz, K.2    Nelson, L.3    Larsen, J.4    White, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.