메뉴 건너뛰기




Volumn 1935, Issue , 2000, Pages 29-39

Telesurgery system for intravascular neurosurgery

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; CATHETER TIP SENSORS; MEDICAL COMPUTING; MEDICAL IMAGING; NEUROSURGERY; REMOTE CONTROL; X RAY CAMERAS; X RAYS;

EID: 84945589596     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-40899-4_4     Document Type: Conference Paper
Times cited : (47)

References (9)
  • 1
    • 0029710144 scopus 로고    scopus 로고
    • Multimedia Tele-surgery Using High Speed Optical Fiber Network and Its Application to Intravascular Neurosurgery
    • F. Arai, et al, “Multimedia Tele-surgery Using High Speed Optical Fiber Network and Its Application to Intravascular Neurosurgery”, Proc. IEEE Int'l Conf. on Robotics and Automation ICRA'96, Vol.l, pp.878-883, 1996.
    • (1996) Proc. IEEE Int'l Conf. On Robotics and Automation ICRA'96 , vol.1 , pp. 878-883
    • Arai, F.1
  • 3
    • 84956685953 scopus 로고    scopus 로고
    • Performance Measurement in Scaled Teleoperation for Microsurgery
    • Grenoble, France
    • S. E. Salcudean, et al., “Performance Measurement in Scaled Teleoperation for Microsurgery”, CVRMed-MRCAS’97, Grenoble, France, pp.789-798,1997.
    • (1997) CVRMed-MRCAS’97 , pp. 789-798
    • Salcudean, S.E.1
  • 5
    • 0031644170 scopus 로고    scopus 로고
    • Augmentation of Safety in Teleoperation System for Intravascular Neurosurgery
    • M. Tanimoto, et al., “Augmentation of Safety in Teleoperation System for Intravascular Neurosurgery”, IEEE Int'l Conf. on Robotics and Automation, pp. 2890-2895,1998
    • (1998) IEEE Int'l Conf. On Robotics and Automation , pp. 2890-2895
    • Tanimoto, M.1
  • 6
    • 0030684204 scopus 로고    scopus 로고
    • Micro Force Sensor for Intravascular Neurosurgery
    • M. Tanimoto, et al., “Micro Force Sensor for Intravascular Neurosurgery”, IEEE Int'l Conf. on Robotics and Automation, Vol. 2, pp. 1561-1566,1997
    • (1997) IEEE Int'l Conf. On Robotics and Automation , vol.2 , pp. 1561-1566
    • Tanimoto, M.1
  • 7
    • 0023962312 scopus 로고
    • A Robot with Improved Adcolute Positioning Accuracy for CT Guided Stereotactic Surgery
    • K.S. Kwon, et al., “A Robot with Improved Adcolute Positioning Accuracy for CT Guided Stereotactic Surgery”, IEEE Trans, on Biomedical Engineering, pp. 153-161, February 1988
    • (1988) IEEE Trans, on Biomedical Engineering , pp. 153-161
    • Kwon, K.S.1
  • 9
    • 0030703390 scopus 로고    scopus 로고
    • Impedance Shaping based on Force Feedback Bilateral Control in Macro-Micro Teleoperation System
    • K. Kaneko, et al., “Impedance Shaping based on Force Feedback Bilateral Control in Macro-Micro Teleoperation System”, IEEE Int'l Conf. on Robotics and Automation, Vol. l, pp. 710-717, 1997
    • (1997) IEEE Int'l Conf. On Robotics and Automation , vol.1 , pp. 710-717
    • Kaneko, K.1