-
1
-
-
38949103007
-
Paraproteins are a common cause of interferences with automated chemistry methods
-
Yang Y., Howanitz P.J., Howanitz J.H., Gorfajn H., Wong K. Paraproteins are a common cause of interferences with automated chemistry methods. Arch. Pathol. Lab. Med. 2008, 132:217-223.
-
(2008)
Arch. Pathol. Lab. Med.
, vol.132
, pp. 217-223
-
-
Yang, Y.1
Howanitz, P.J.2
Howanitz, J.H.3
Gorfajn, H.4
Wong, K.5
-
2
-
-
84904015326
-
Monoclonal and polyclonal immunoglobulin interference in a conjugated bilirubin assay
-
Song L., Kelly K.A., Butch A.W. Monoclonal and polyclonal immunoglobulin interference in a conjugated bilirubin assay. Arch. Pathol. Lab. Med. 2014, 138:950-954.
-
(2014)
Arch. Pathol. Lab. Med.
, vol.138
, pp. 950-954
-
-
Song, L.1
Kelly, K.A.2
Butch, A.W.3
-
3
-
-
0023351928
-
Interference by an IgM paraprotein in the bromcresol green method for determination of serum albumin
-
Reed R.G. Interference by an IgM paraprotein in the bromcresol green method for determination of serum albumin. Clin. Chem. 1987, 33:1075-1076.
-
(1987)
Clin. Chem.
, vol.33
, pp. 1075-1076
-
-
Reed, R.G.1
-
4
-
-
27444440190
-
Rare IgM interference with Roche/Hitachi Modular glucose and gamma-glutamyltransferase methods in heparin samples
-
Dimeski G., Carter A. Rare IgM interference with Roche/Hitachi Modular glucose and gamma-glutamyltransferase methods in heparin samples. Clin. Chem. 2005, 51:2202-2204.
-
(2005)
Clin. Chem.
, vol.51
, pp. 2202-2204
-
-
Dimeski, G.1
Carter, A.2
-
5
-
-
0025351680
-
Excessive sample blankings in two analyzers generate reports of apparent hypoglycemia and hypophosphatemia in patients with macroglobulinemia
-
Tokmakjian S., Moses G., Haines M. Excessive sample blankings in two analyzers generate reports of apparent hypoglycemia and hypophosphatemia in patients with macroglobulinemia. Clin. Chem. 1990, 36:1261-1262.
-
(1990)
Clin. Chem.
, vol.36
, pp. 1261-1262
-
-
Tokmakjian, S.1
Moses, G.2
Haines, M.3
-
6
-
-
0031309449
-
Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-kappa from a myeloma patient
-
Yamada K., Yagihashi A., Ishii S., et al. Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-kappa from a myeloma patient. Clin. Chem. 1997, 43:2435-2437.
-
(1997)
Clin. Chem.
, vol.43
, pp. 2435-2437
-
-
Yamada, K.1
Yagihashi, A.2
Ishii, S.3
-
7
-
-
0032192467
-
Interference of IgM paraproteins in the Olympus AU800 uric acid assay
-
Langman L.J., Allen L.C., Romaschin A.D. Interference of IgM paraproteins in the Olympus AU800 uric acid assay. Clin. Biochem. 1998, 31:517-521.
-
(1998)
Clin. Biochem.
, vol.31
, pp. 517-521
-
-
Langman, L.J.1
Allen, L.C.2
Romaschin, A.D.3
-
8
-
-
4344659382
-
Paraprotein interference in automated chemistry analyzers
-
Smogorzewska A., Flood J.G., Long W.H., Dighe A.S. Paraprotein interference in automated chemistry analyzers. Clin. Chem. 2004, 50:1691-1693.
-
(2004)
Clin. Chem.
, vol.50
, pp. 1691-1693
-
-
Smogorzewska, A.1
Flood, J.G.2
Long, W.H.3
Dighe, A.S.4
-
9
-
-
0141741174
-
False negative results in the Roche assay for HDL-cholesterol
-
Bakker A.J., Zijlstra A., Leemhuis M.P. False negative results in the Roche assay for HDL-cholesterol. Ann. Clin. Biochem. 2003, 40:572-575.
-
(2003)
Ann. Clin. Biochem.
, vol.40
, pp. 572-575
-
-
Bakker, A.J.1
Zijlstra, A.2
Leemhuis, M.P.3
-
10
-
-
0036275513
-
Monoclonal paraprotein may interfere with the Roche direct HDL-C Plus assay
-
Kadri N., Douville P., Lachance P. Monoclonal paraprotein may interfere with the Roche direct HDL-C Plus assay. Clin. Chem. 2002, 48:964.
-
(2002)
Clin. Chem.
, vol.48
, pp. 964
-
-
Kadri, N.1
Douville, P.2
Lachance, P.3
-
11
-
-
0037283855
-
Artifactual hyperbilirubinemia due to paraprotein interference
-
Pantanowitz L., Horowitz G.L., Upalakalin J.N., Beckwith B.A. Artifactual hyperbilirubinemia due to paraprotein interference. Arch. Pathol. Lab. Med. 2003, 127:55-59.
-
(2003)
Arch. Pathol. Lab. Med.
, vol.127
, pp. 55-59
-
-
Pantanowitz, L.1
Horowitz, G.L.2
Upalakalin, J.N.3
Beckwith, B.A.4
-
12
-
-
0033815932
-
Pseudohypercreatininemia due to positive interference in enzymatic creatinine measurements caused by monoclonal IgM in patients with Waldenstrom macroglobulinemia
-
Hummel K.M., von Ahsen N., Kuhn R.B., et al. Pseudohypercreatininemia due to positive interference in enzymatic creatinine measurements caused by monoclonal IgM in patients with Waldenstrom macroglobulinemia. Nephron 2000, 86:188-189.
-
(2000)
Nephron
, vol.86
, pp. 188-189
-
-
Hummel, K.M.1
von Ahsen, N.2
Kuhn, R.B.3
-
13
-
-
75749136509
-
The case: Renal failure in a male with Waldenstrom macroglobulinemia
-
Rudofsky G., Villalobos M., Waldherr R., et al. The case: Renal failure in a male with Waldenstrom macroglobulinemia. Kidney Int. 2010, 77:371-372.
-
(2010)
Kidney Int.
, vol.77
, pp. 371-372
-
-
Rudofsky, G.1
Villalobos, M.2
Waldherr, R.3
-
14
-
-
33750020338
-
IgM monoclonal protein presenting as pseudohypercreatininaemia
-
Storsley L., Fine A., Krahn J. IgM monoclonal protein presenting as pseudohypercreatininaemia. Nephrol. Dial. Transplant. 2006, 21:3337-3338.
-
(2006)
Nephrol. Dial. Transplant.
, vol.21
, pp. 3337-3338
-
-
Storsley, L.1
Fine, A.2
Krahn, J.3
-
15
-
-
77956196476
-
Paraproteinemia-associated pseudohypercreatininemia across different analytical methodologies
-
Kwok J.S., Chow K.M., Lit L.C., Chan M.H. Paraproteinemia-associated pseudohypercreatininemia across different analytical methodologies. Kidney Int. 2010, 78:621-622.
-
(2010)
Kidney Int.
, vol.78
, pp. 621-622
-
-
Kwok, J.S.1
Chow, K.M.2
Lit, L.C.3
Chan, M.H.4
-
16
-
-
59849088770
-
Interference of IgM-lambda paraprotein with biuret-type assay for total serum protein quantification
-
Tichy M., Friedecky B., Budina M., et al. Interference of IgM-lambda paraprotein with biuret-type assay for total serum protein quantification. Clin. Chem. Lab. Med. 2009, 47:235-236.
-
(2009)
Clin. Chem. Lab. Med.
, vol.47
, pp. 235-236
-
-
Tichy, M.1
Friedecky, B.2
Budina, M.3
-
17
-
-
0024041347
-
Discrepant serum total protein results for serum from some myeloma patients, as analyzed in the SMAC
-
Sykes M.O., Harrison S.P. Discrepant serum total protein results for serum from some myeloma patients, as analyzed in the SMAC. Clin. Chem. 1988, 34:1521.
-
(1988)
Clin. Chem.
, vol.34
, pp. 1521
-
-
Sykes, M.O.1
Harrison, S.P.2
-
18
-
-
0021133297
-
Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: a method-dependent error
-
Whitlow K.J., Nanji A.A., Pudek M.R. Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: a method-dependent error. Clin. Biochem. 1984, 17:233-235.
-
(1984)
Clin. Biochem.
, vol.17
, pp. 233-235
-
-
Whitlow, K.J.1
Nanji, A.A.2
Pudek, M.R.3
-
19
-
-
0030829838
-
Pseudohypercalcaemia in two patients with IgM paraproteinaemia
-
John R., Oleesky D., Issa B., et al. Pseudohypercalcaemia in two patients with IgM paraproteinaemia. Ann. Clin. Biochem. 1997, 34(Pt 6):694-696.
-
(1997)
Ann. Clin. Biochem.
, vol.34
, pp. 694-696
-
-
John, R.1
Oleesky, D.2
Issa, B.3
-
20
-
-
70349627933
-
Antibodies
-
Elsevier Publishing Inc, Amsterdam, Netherlands, D. Wild (Ed.)
-
Liddell E. Antibodies. The Immunoassay Handbook 2005, 146. Elsevier Publishing Inc, Amsterdam, Netherlands. third edition. D. Wild (Ed.).
-
(2005)
The Immunoassay Handbook
, pp. 146
-
-
Liddell, E.1
-
21
-
-
0141567459
-
Physical stability of proteins in aqueous solution: mechanism and driving forces in nonnative protein aggregation
-
Chi E.Y., Krishnan S., Randolph T.W., Carpenter J.F. Physical stability of proteins in aqueous solution: mechanism and driving forces in nonnative protein aggregation. Pharm. Res. 2003, 20:1325-1336.
-
(2003)
Pharm. Res.
, vol.20
, pp. 1325-1336
-
-
Chi, E.Y.1
Krishnan, S.2
Randolph, T.W.3
Carpenter, J.F.4
-
22
-
-
11144296752
-
Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature
-
Berth M., Delanghe J. Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature. Acta Clin. Belg. 2004, 59:263-273.
-
(2004)
Acta Clin. Belg.
, vol.59
, pp. 263-273
-
-
Berth, M.1
Delanghe, J.2
-
23
-
-
77954796516
-
How paraproteins can affect laboratory assays: spurious results and biological effects
-
King R.I., Florkowski C.M. How paraproteins can affect laboratory assays: spurious results and biological effects. Pathology 2010, 42:397-401.
-
(2010)
Pathology
, vol.42
, pp. 397-401
-
-
King, R.I.1
Florkowski, C.M.2
-
24
-
-
34548546658
-
Gammopathy interference in clinical chemistry assays: mechanisms, detection and prevention
-
Bakker A.J., Mucke M. Gammopathy interference in clinical chemistry assays: mechanisms, detection and prevention. Clin. Chem. Lab. Med. 2007, 45:1240-1243.
-
(2007)
Clin. Chem. Lab. Med.
, vol.45
, pp. 1240-1243
-
-
Bakker, A.J.1
Mucke, M.2
-
25
-
-
63249084204
-
Artifactual laboratory abnormalities in patients with paraproteinemia
-
Roy V. Artifactual laboratory abnormalities in patients with paraproteinemia. South. Med. J. 2009, 102:167-170.
-
(2009)
South. Med. J.
, vol.102
, pp. 167-170
-
-
Roy, V.1
-
26
-
-
58849135418
-
Factitious biochemical measurements resulting from hematologic conditions
-
Dalal B.I., Brigden M.L. Factitious biochemical measurements resulting from hematologic conditions. Am. J. Clin. Pathol. 2009, 131:195-204.
-
(2009)
Am. J. Clin. Pathol.
, vol.131
, pp. 195-204
-
-
Dalal, B.I.1
Brigden, M.L.2
-
27
-
-
84919933494
-
The abnormal reaction data-detecting function of the automated biochemical analyzer was useful to prevent erroneous total-bilirubin measurement and to identify monoclonal proteins
-
Seimiya M., Suzuki Y., Yoshida T., Sawabe Y., Matsushita K., Nomura F. The abnormal reaction data-detecting function of the automated biochemical analyzer was useful to prevent erroneous total-bilirubin measurement and to identify monoclonal proteins. Clin. Chim. Acta 2014, 441c:44-46.
-
(2014)
Clin. Chim. Acta
, vol.441c
, pp. 44-46
-
-
Seimiya, M.1
Suzuki, Y.2
Yoshida, T.3
Sawabe, Y.4
Matsushita, K.5
Nomura, F.6
|