메뉴 건너뛰기




Volumn 3, Issue , 2015, Pages 8-16

The pH of chemistry assays plays an important role in monoclonal immunoglobulin interferences

Author keywords

Assay conditions; Creatinine; IgM paraprotein; Interference of chemistry assays; Monoclonal protein; PH induced

Indexed keywords


EID: 84945321566     PISSN: None     EISSN: 23525517     Source Type: Journal    
DOI: 10.1016/j.plabm.2015.09.001     Document Type: Article
Times cited : (14)

References (27)
  • 1
    • 38949103007 scopus 로고    scopus 로고
    • Paraproteins are a common cause of interferences with automated chemistry methods
    • Yang Y., Howanitz P.J., Howanitz J.H., Gorfajn H., Wong K. Paraproteins are a common cause of interferences with automated chemistry methods. Arch. Pathol. Lab. Med. 2008, 132:217-223.
    • (2008) Arch. Pathol. Lab. Med. , vol.132 , pp. 217-223
    • Yang, Y.1    Howanitz, P.J.2    Howanitz, J.H.3    Gorfajn, H.4    Wong, K.5
  • 2
    • 84904015326 scopus 로고    scopus 로고
    • Monoclonal and polyclonal immunoglobulin interference in a conjugated bilirubin assay
    • Song L., Kelly K.A., Butch A.W. Monoclonal and polyclonal immunoglobulin interference in a conjugated bilirubin assay. Arch. Pathol. Lab. Med. 2014, 138:950-954.
    • (2014) Arch. Pathol. Lab. Med. , vol.138 , pp. 950-954
    • Song, L.1    Kelly, K.A.2    Butch, A.W.3
  • 3
    • 0023351928 scopus 로고
    • Interference by an IgM paraprotein in the bromcresol green method for determination of serum albumin
    • Reed R.G. Interference by an IgM paraprotein in the bromcresol green method for determination of serum albumin. Clin. Chem. 1987, 33:1075-1076.
    • (1987) Clin. Chem. , vol.33 , pp. 1075-1076
    • Reed, R.G.1
  • 4
    • 27444440190 scopus 로고    scopus 로고
    • Rare IgM interference with Roche/Hitachi Modular glucose and gamma-glutamyltransferase methods in heparin samples
    • Dimeski G., Carter A. Rare IgM interference with Roche/Hitachi Modular glucose and gamma-glutamyltransferase methods in heparin samples. Clin. Chem. 2005, 51:2202-2204.
    • (2005) Clin. Chem. , vol.51 , pp. 2202-2204
    • Dimeski, G.1    Carter, A.2
  • 5
    • 0025351680 scopus 로고
    • Excessive sample blankings in two analyzers generate reports of apparent hypoglycemia and hypophosphatemia in patients with macroglobulinemia
    • Tokmakjian S., Moses G., Haines M. Excessive sample blankings in two analyzers generate reports of apparent hypoglycemia and hypophosphatemia in patients with macroglobulinemia. Clin. Chem. 1990, 36:1261-1262.
    • (1990) Clin. Chem. , vol.36 , pp. 1261-1262
    • Tokmakjian, S.1    Moses, G.2    Haines, M.3
  • 6
    • 0031309449 scopus 로고    scopus 로고
    • Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-kappa from a myeloma patient
    • Yamada K., Yagihashi A., Ishii S., et al. Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-kappa from a myeloma patient. Clin. Chem. 1997, 43:2435-2437.
    • (1997) Clin. Chem. , vol.43 , pp. 2435-2437
    • Yamada, K.1    Yagihashi, A.2    Ishii, S.3
  • 7
    • 0032192467 scopus 로고    scopus 로고
    • Interference of IgM paraproteins in the Olympus AU800 uric acid assay
    • Langman L.J., Allen L.C., Romaschin A.D. Interference of IgM paraproteins in the Olympus AU800 uric acid assay. Clin. Biochem. 1998, 31:517-521.
    • (1998) Clin. Biochem. , vol.31 , pp. 517-521
    • Langman, L.J.1    Allen, L.C.2    Romaschin, A.D.3
  • 8
    • 4344659382 scopus 로고    scopus 로고
    • Paraprotein interference in automated chemistry analyzers
    • Smogorzewska A., Flood J.G., Long W.H., Dighe A.S. Paraprotein interference in automated chemistry analyzers. Clin. Chem. 2004, 50:1691-1693.
    • (2004) Clin. Chem. , vol.50 , pp. 1691-1693
    • Smogorzewska, A.1    Flood, J.G.2    Long, W.H.3    Dighe, A.S.4
  • 9
    • 0141741174 scopus 로고    scopus 로고
    • False negative results in the Roche assay for HDL-cholesterol
    • Bakker A.J., Zijlstra A., Leemhuis M.P. False negative results in the Roche assay for HDL-cholesterol. Ann. Clin. Biochem. 2003, 40:572-575.
    • (2003) Ann. Clin. Biochem. , vol.40 , pp. 572-575
    • Bakker, A.J.1    Zijlstra, A.2    Leemhuis, M.P.3
  • 10
    • 0036275513 scopus 로고    scopus 로고
    • Monoclonal paraprotein may interfere with the Roche direct HDL-C Plus assay
    • Kadri N., Douville P., Lachance P. Monoclonal paraprotein may interfere with the Roche direct HDL-C Plus assay. Clin. Chem. 2002, 48:964.
    • (2002) Clin. Chem. , vol.48 , pp. 964
    • Kadri, N.1    Douville, P.2    Lachance, P.3
  • 12
    • 0033815932 scopus 로고    scopus 로고
    • Pseudohypercreatininemia due to positive interference in enzymatic creatinine measurements caused by monoclonal IgM in patients with Waldenstrom macroglobulinemia
    • Hummel K.M., von Ahsen N., Kuhn R.B., et al. Pseudohypercreatininemia due to positive interference in enzymatic creatinine measurements caused by monoclonal IgM in patients with Waldenstrom macroglobulinemia. Nephron 2000, 86:188-189.
    • (2000) Nephron , vol.86 , pp. 188-189
    • Hummel, K.M.1    von Ahsen, N.2    Kuhn, R.B.3
  • 13
    • 75749136509 scopus 로고    scopus 로고
    • The case: Renal failure in a male with Waldenstrom macroglobulinemia
    • Rudofsky G., Villalobos M., Waldherr R., et al. The case: Renal failure in a male with Waldenstrom macroglobulinemia. Kidney Int. 2010, 77:371-372.
    • (2010) Kidney Int. , vol.77 , pp. 371-372
    • Rudofsky, G.1    Villalobos, M.2    Waldherr, R.3
  • 14
    • 33750020338 scopus 로고    scopus 로고
    • IgM monoclonal protein presenting as pseudohypercreatininaemia
    • Storsley L., Fine A., Krahn J. IgM monoclonal protein presenting as pseudohypercreatininaemia. Nephrol. Dial. Transplant. 2006, 21:3337-3338.
    • (2006) Nephrol. Dial. Transplant. , vol.21 , pp. 3337-3338
    • Storsley, L.1    Fine, A.2    Krahn, J.3
  • 15
    • 77956196476 scopus 로고    scopus 로고
    • Paraproteinemia-associated pseudohypercreatininemia across different analytical methodologies
    • Kwok J.S., Chow K.M., Lit L.C., Chan M.H. Paraproteinemia-associated pseudohypercreatininemia across different analytical methodologies. Kidney Int. 2010, 78:621-622.
    • (2010) Kidney Int. , vol.78 , pp. 621-622
    • Kwok, J.S.1    Chow, K.M.2    Lit, L.C.3    Chan, M.H.4
  • 16
    • 59849088770 scopus 로고    scopus 로고
    • Interference of IgM-lambda paraprotein with biuret-type assay for total serum protein quantification
    • Tichy M., Friedecky B., Budina M., et al. Interference of IgM-lambda paraprotein with biuret-type assay for total serum protein quantification. Clin. Chem. Lab. Med. 2009, 47:235-236.
    • (2009) Clin. Chem. Lab. Med. , vol.47 , pp. 235-236
    • Tichy, M.1    Friedecky, B.2    Budina, M.3
  • 17
    • 0024041347 scopus 로고
    • Discrepant serum total protein results for serum from some myeloma patients, as analyzed in the SMAC
    • Sykes M.O., Harrison S.P. Discrepant serum total protein results for serum from some myeloma patients, as analyzed in the SMAC. Clin. Chem. 1988, 34:1521.
    • (1988) Clin. Chem. , vol.34 , pp. 1521
    • Sykes, M.O.1    Harrison, S.P.2
  • 18
    • 0021133297 scopus 로고
    • Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: a method-dependent error
    • Whitlow K.J., Nanji A.A., Pudek M.R. Artefactual decrease in total protein concentration in patients with monoclonal gammopathies: a method-dependent error. Clin. Biochem. 1984, 17:233-235.
    • (1984) Clin. Biochem. , vol.17 , pp. 233-235
    • Whitlow, K.J.1    Nanji, A.A.2    Pudek, M.R.3
  • 19
    • 0030829838 scopus 로고    scopus 로고
    • Pseudohypercalcaemia in two patients with IgM paraproteinaemia
    • John R., Oleesky D., Issa B., et al. Pseudohypercalcaemia in two patients with IgM paraproteinaemia. Ann. Clin. Biochem. 1997, 34(Pt 6):694-696.
    • (1997) Ann. Clin. Biochem. , vol.34 , pp. 694-696
    • John, R.1    Oleesky, D.2    Issa, B.3
  • 20
    • 70349627933 scopus 로고    scopus 로고
    • Antibodies
    • Elsevier Publishing Inc, Amsterdam, Netherlands, D. Wild (Ed.)
    • Liddell E. Antibodies. The Immunoassay Handbook 2005, 146. Elsevier Publishing Inc, Amsterdam, Netherlands. third edition. D. Wild (Ed.).
    • (2005) The Immunoassay Handbook , pp. 146
    • Liddell, E.1
  • 21
    • 0141567459 scopus 로고    scopus 로고
    • Physical stability of proteins in aqueous solution: mechanism and driving forces in nonnative protein aggregation
    • Chi E.Y., Krishnan S., Randolph T.W., Carpenter J.F. Physical stability of proteins in aqueous solution: mechanism and driving forces in nonnative protein aggregation. Pharm. Res. 2003, 20:1325-1336.
    • (2003) Pharm. Res. , vol.20 , pp. 1325-1336
    • Chi, E.Y.1    Krishnan, S.2    Randolph, T.W.3    Carpenter, J.F.4
  • 22
    • 11144296752 scopus 로고    scopus 로고
    • Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature
    • Berth M., Delanghe J. Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature. Acta Clin. Belg. 2004, 59:263-273.
    • (2004) Acta Clin. Belg. , vol.59 , pp. 263-273
    • Berth, M.1    Delanghe, J.2
  • 23
    • 77954796516 scopus 로고    scopus 로고
    • How paraproteins can affect laboratory assays: spurious results and biological effects
    • King R.I., Florkowski C.M. How paraproteins can affect laboratory assays: spurious results and biological effects. Pathology 2010, 42:397-401.
    • (2010) Pathology , vol.42 , pp. 397-401
    • King, R.I.1    Florkowski, C.M.2
  • 24
    • 34548546658 scopus 로고    scopus 로고
    • Gammopathy interference in clinical chemistry assays: mechanisms, detection and prevention
    • Bakker A.J., Mucke M. Gammopathy interference in clinical chemistry assays: mechanisms, detection and prevention. Clin. Chem. Lab. Med. 2007, 45:1240-1243.
    • (2007) Clin. Chem. Lab. Med. , vol.45 , pp. 1240-1243
    • Bakker, A.J.1    Mucke, M.2
  • 25
    • 63249084204 scopus 로고    scopus 로고
    • Artifactual laboratory abnormalities in patients with paraproteinemia
    • Roy V. Artifactual laboratory abnormalities in patients with paraproteinemia. South. Med. J. 2009, 102:167-170.
    • (2009) South. Med. J. , vol.102 , pp. 167-170
    • Roy, V.1
  • 26
    • 58849135418 scopus 로고    scopus 로고
    • Factitious biochemical measurements resulting from hematologic conditions
    • Dalal B.I., Brigden M.L. Factitious biochemical measurements resulting from hematologic conditions. Am. J. Clin. Pathol. 2009, 131:195-204.
    • (2009) Am. J. Clin. Pathol. , vol.131 , pp. 195-204
    • Dalal, B.I.1    Brigden, M.L.2
  • 27
    • 84919933494 scopus 로고    scopus 로고
    • The abnormal reaction data-detecting function of the automated biochemical analyzer was useful to prevent erroneous total-bilirubin measurement and to identify monoclonal proteins
    • Seimiya M., Suzuki Y., Yoshida T., Sawabe Y., Matsushita K., Nomura F. The abnormal reaction data-detecting function of the automated biochemical analyzer was useful to prevent erroneous total-bilirubin measurement and to identify monoclonal proteins. Clin. Chim. Acta 2014, 441c:44-46.
    • (2014) Clin. Chim. Acta , vol.441c , pp. 44-46
    • Seimiya, M.1    Suzuki, Y.2    Yoshida, T.3    Sawabe, Y.4    Matsushita, K.5    Nomura, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.