Rare IgM interference with Roche/Hitachi Modular glucose and γ-glutamyltransferase methods in heparin samples

Author keywords

[No Author keywords available]

Indexed keywords

GAMMA GLUTAMYLTRANSFERASE; GLUCOSE; GLUCOSE OXIDASE; HEPARIN; IMMUNOGLOBULIN M; PARAPROTEIN; REAGENT;

EID: 27444440190     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/clinchem.2005.053561     Document Type: Article
Times cited : (22)

References (7)
  • 1
    • 11144296752 scopus 로고    scopus 로고
    • Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 Case reports and a review of the literature
    • Berth M, Delanghe J. Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature. Acta Clin Belg 2004;59:263-73.
    • (2004) Acta Clin Belg , vol.59 , pp. 263-273
    • Berth, M.1    Delanghe, J.2
  • 2
    • 0022414824 scopus 로고
    • Heparin interference in the measurement of γ-glutamyltransferase activity with the Scandinavian and the IFCC recommended method
    • Stromme JH, Theodorsen L. Heparin interference in the measurement of γ-glutamyltransferase activity with the Scandinavian and the IFCC recommended method. Scan J Clin Lab Invest 1985;45:437-42.
    • (1985) Scan J Clin Lab Invest , vol.45 , pp. 437-442
    • Stromme, J.H.1    Theodorsen, L.2
  • 4
    • 0028912834 scopus 로고
    • Elimination of paraprotein interference in determination of plasma inorganic phosphate by ammonium molybdate method
    • Zaman Z, Sneyers L, Van Orshoven A, Blanckaert N, Marlen G. Elimination of paraprotein interference in determination of plasma inorganic phosphate by ammonium molybdate method. Clin Chem 1995;41:609-14.
    • (1995) Clin Chem , vol.41 , pp. 609-614
    • Zaman, Z.1    Sneyers, L.2    Van Orshoven, A.3    Blanckaert, N.4    Marlen, G.5
  • 6
    • 4344659382 scopus 로고    scopus 로고
    • Paraprotein interference in automated chemical analyzers [Technical Brief]
    • Smogorzewska A, Rood JG, Long WH, Dighe AS. Paraprotein interference in automated chemical analyzers [Technical Brief]. Clin Chem 2004;50:1691-3.
    • (2004) Clin Chem , vol.50 , pp. 1691-1693
    • Smogorzewska, A.1    Rood, J.G.2    Long, W.H.3    Dighe, A.S.4
  • 7
    • 0025351680 scopus 로고
    • Excessive sample blanking in two analyzers generate reports of apparent hypoglycemia and hypophosphatemia in patients with macroglobulinemia
    • Tokmakjian S, Moses G, Haines M. Excessive sample blanking in two analyzers generate reports of apparent hypoglycemia and hypophosphatemia in patients with macroglobulinemia [Letter]. Clin Chem 1990;36:1261-2.
    • (1990) Clin Chem , vol.36 , pp. 1261-1262
    • Tokmakjian, S.1    Moses, G.2    Haines, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.