-
2
-
-
34247331304
-
Intravascular photoacoustic imaging using an IVUS imaging catheter
-
Sethuraman S., Aglyamov S.R., Amirian J.H., Smalling R.W., Emelianov S.Y. Intravascular photoacoustic imaging using an IVUS imaging catheter. IEEE Trans Ultrason Ferroelectr Freq Control 2007, 54(5):978-986.
-
(2007)
IEEE Trans Ultrason Ferroelectr Freq Control
, vol.54
, Issue.5
, pp. 978-986
-
-
Sethuraman, S.1
Aglyamov, S.R.2
Amirian, J.H.3
Smalling, R.W.4
Emelianov, S.Y.5
-
3
-
-
77953293939
-
Intravascular photoacoustic imaging
-
Wang B., Su J.L., Karpiouk A.B., Sokolov K.V., Smalling R.W., Emelianov S.Y. Intravascular photoacoustic imaging. IEEE J Sel Top Quantum Electron 2010, 16(3):588-599.
-
(2010)
IEEE J Sel Top Quantum Electron
, vol.16
, Issue.3
, pp. 588-599
-
-
Wang, B.1
Su, J.L.2
Karpiouk, A.B.3
Sokolov, K.V.4
Smalling, R.W.5
Emelianov, S.Y.6
-
4
-
-
84870302897
-
Feasibility of in vivo intravascular photoacoustic imaging using integrated ultrasound and photoacoustic imaging catheter
-
Karpiouk A.B., Wang B., Amirian J., Smalling R.W., Emelianov S.Y. Feasibility of in vivo intravascular photoacoustic imaging using integrated ultrasound and photoacoustic imaging catheter. J Biomed Opt 2012, 17(9):960081-960086.
-
(2012)
J Biomed Opt
, vol.17
, Issue.9
, pp. 960081-960086
-
-
Karpiouk, A.B.1
Wang, B.2
Amirian, J.3
Smalling, R.W.4
Emelianov, S.Y.5
-
5
-
-
84867301325
-
A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy
-
Yang J.-M., Chen R., Favazza C., Yao J., Li C., Hu Z., et al. A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy. Opt Express 2012, 20(21):23944-23953.
-
(2012)
Opt Express
, vol.20
, Issue.21
, pp. 23944-23953
-
-
Yang, J.-M.1
Chen, R.2
Favazza, C.3
Yao, J.4
Li, C.5
Hu, Z.6
-
6
-
-
84904348813
-
Intravascular optical-resolution photoacoustic tomography with a 1.1mm diameter catheter
-
Bai X., Gong X., Hau W., Lin R., Zheng J., Liu C., et al. Intravascular optical-resolution photoacoustic tomography with a 1.1mm diameter catheter. PLoS ONE 2014, 9(3):e92463.
-
(2014)
PLoS ONE
, vol.9
, Issue.3
, pp. e92463
-
-
Bai, X.1
Gong, X.2
Hau, W.3
Lin, R.4
Zheng, J.5
Liu, C.6
-
7
-
-
0141885294
-
From vulnerable plaque to vulnerable patient a call for new definitions and risk assessment strategies: Part I
-
Naghavi M., Libby P., Falk E., Casscells S.W., Litovsky S., Rumberger J., et al. From vulnerable plaque to vulnerable patient a call for new definitions and risk assessment strategies: Part I. Circulation 2003, 108(14):1664-1672.
-
(2003)
Circulation
, vol.108
, Issue.14
, pp. 1664-1672
-
-
Naghavi, M.1
Libby, P.2
Falk, E.3
Casscells, S.W.4
Litovsky, S.5
Rumberger, J.6
-
8
-
-
0034019601
-
Lessons from sudden coronary death a comprehensive morphological classification scheme for atherosclerotic lesions
-
Virmani R., Kolodgie F.D., Burke A.P., Farb A., Schwartz S.M. Lessons from sudden coronary death a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol 2000, 20(5):1262-1275.
-
(2000)
Arterioscler Thromb Vasc Biol
, vol.20
, Issue.5
, pp. 1262-1275
-
-
Virmani, R.1
Kolodgie, F.D.2
Burke, A.P.3
Farb, A.4
Schwartz, S.M.5
-
9
-
-
84884543843
-
Lipid detection in atherosclerotic human coronaries by spectroscopic intravascular photoacoustic imaging
-
Jansen K., Wu M., van der Steen A.F., van Soest G. Lipid detection in atherosclerotic human coronaries by spectroscopic intravascular photoacoustic imaging. Opt Express 2013, 21(18):21472-21484.
-
(2013)
Opt Express
, vol.21
, Issue.18
, pp. 21472-21484
-
-
Jansen, K.1
Wu, M.2
van der Steen, A.F.3
van Soest, G.4
-
10
-
-
56749173567
-
Noninvasive photoacoustic identification of sentinel lymph nodes containing methylene blue in vivo in a rat model
-
054033-054033-054036
-
Song K.H., Margenthaler J.A., Wang L.V., Stein E.W. Noninvasive photoacoustic identification of sentinel lymph nodes containing methylene blue in vivo in a rat model. J Biomed Opt 2008, 13(5). 054033-054033-054036.
-
(2008)
J Biomed Opt
, vol.13
, Issue.5
-
-
Song, K.H.1
Margenthaler, J.A.2
Wang, L.V.3
Stein, E.W.4
-
11
-
-
84944932702
-
Metallic nanoparticles as optoacoustic contrast agents for medical imaging
-
International Society for Optics and Photonics, 60860K-60860K-60869
-
Conjusteau A., Ermilov S.A., Lapotko D., Liao H., Hafner J., Eghtedari M., et al. Metallic nanoparticles as optoacoustic contrast agents for medical imaging. Biomedical optics 2006: 2006 2006, International Society for Optics and Photonics, 60860K-60860K-60869.
-
(2006)
Biomedical optics 2006: 2006
-
-
Conjusteau, A.1
Ermilov, S.A.2
Lapotko, D.3
Liao, H.4
Hafner, J.5
Eghtedari, M.6
-
12
-
-
77951452616
-
Sentinel lymph nodes and lymphatic vessels: noninvasive dual-modality in vivo mapping by using indocyanine green in rats-volumetric spectroscopic photoacoustic imaging and planar fluorescence imaging 1
-
Kim C., Song K.H., Gao F., Wang L.V. Sentinel lymph nodes and lymphatic vessels: noninvasive dual-modality in vivo mapping by using indocyanine green in rats-volumetric spectroscopic photoacoustic imaging and planar fluorescence imaging 1. Radiology 2010, 255(2):442-450.
-
(2010)
Radiology
, vol.255
, Issue.2
, pp. 442-450
-
-
Kim, C.1
Song, K.H.2
Gao, F.3
Wang, L.V.4
-
13
-
-
84944886203
-
A tricarbocyanine dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation
-
Fox I., Brooker L., Heseltine D., Essex H., Wood E. A tricarbocyanine dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation. Proceedings of the Staff Meetings 1957, 478.
-
(1957)
Proceedings of the Staff Meetings
, pp. 478
-
-
Fox, I.1
Brooker, L.2
Heseltine, D.3
Essex, H.4
Wood, E.5
-
14
-
-
0001873290
-
The use of indocyanine green in the measurement of hepatic blood flow and as a test of hepatic function
-
Caesar J., Shaldon S., Chiandussi Le, Guevara L., Sherlock S. The use of indocyanine green in the measurement of hepatic blood flow and as a test of hepatic function. Clin Sci 1961, 21:43.
-
(1961)
Clin Sci
, vol.21
, pp. 43
-
-
Caesar, J.1
Shaldon, S.2
Chiandussi, Le3
Guevara, L.4
Sherlock, S.5
-
15
-
-
0034661367
-
Fluorescence properties and metabolic features of indocyanine green (ICG) as related to angiography
-
Desmettre T., Devoisselle J., Mordon S. Fluorescence properties and metabolic features of indocyanine green (ICG) as related to angiography. Surv Ophthalmol 2000, 45(1):15-27.
-
(2000)
Surv Ophthalmol
, vol.45
, Issue.1
, pp. 15-27
-
-
Desmettre, T.1
Devoisselle, J.2
Mordon, S.3
-
16
-
-
0017810432
-
Fluorescence properties of indocyanine green as related to angiography
-
Benson R.C., Kues H.A. Fluorescence properties of indocyanine green as related to angiography. Phys Med Biol 1978, 23(1):159.
-
(1978)
Phys Med Biol
, vol.23
, Issue.1
, pp. 159
-
-
Benson, R.C.1
Kues, H.A.2
-
17
-
-
0342303010
-
Evolution of indocyanine green dye choroidal angiography
-
Flower R.W. Evolution of indocyanine green dye choroidal angiography. Opt Eng 1995, 34(3):727-736.
-
(1995)
Opt Eng
, vol.34
, Issue.3
, pp. 727-736
-
-
Flower, R.W.1
-
18
-
-
0031835403
-
Binding properties of indocyanine green in human blood
-
Yoneya S., Saito T., Komatsu Y., Koyama I., Takahashi K., Duvoll-Young J. Binding properties of indocyanine green in human blood. Invest Ophthalmol Vis Sci 1998, 39(7):1286-1290.
-
(1998)
Invest Ophthalmol Vis Sci
, vol.39
, Issue.7
, pp. 1286-1290
-
-
Yoneya, S.1
Saito, T.2
Komatsu, Y.3
Koyama, I.4
Takahashi, K.5
Duvoll-Young, J.6
-
19
-
-
79957469461
-
Indocyanine green enables near-infrared fluorescence imaging of lipid-rich, inflamed atherosclerotic plaques
-
84ra45
-
Vinegoni C., Botnaru I., Aikawa E., Calfon M.A., Iwamoto Y., Folco E.J., et al. Indocyanine green enables near-infrared fluorescence imaging of lipid-rich, inflamed atherosclerotic plaques. Sci Transl Med 2011, 3(84):84ra45. http://stm.sciencemag.org/content/3/84/84ra45. 10.1126/scitranslmed.3001577.
-
(2011)
Sci Transl Med
, vol.3
, Issue.84
-
-
Vinegoni, C.1
Botnaru, I.2
Aikawa, E.3
Calfon, M.A.4
Iwamoto, Y.5
Folco, E.J.6
-
20
-
-
0037224731
-
Indocyanine green angiography in chorioretinal diseases: indications and interpretation: an evidence-based update
-
Stanga P.E., Lim J.I., Hamilton P. Indocyanine green angiography in chorioretinal diseases: indications and interpretation: an evidence-based update. Ophthalmology 2003, 110(1):15-21.
-
(2003)
Ophthalmology
, vol.110
, Issue.1
, pp. 15-21
-
-
Stanga, P.E.1
Lim, J.I.2
Hamilton, P.3
-
21
-
-
29944441233
-
Assessment of unspecific near-infrared dyes in laser-induced fluorescence imaging of experimental arthritis
-
Fischer T., Gemeinhardt I., Wagner S., Stieglitz D.V., Schnorr J., Hermann K.-G.A., et al. Assessment of unspecific near-infrared dyes in laser-induced fluorescence imaging of experimental arthritis. Acad Radiol 2006, 13(1):4-13.
-
(2006)
Acad Radiol
, vol.13
, Issue.1
, pp. 4-13
-
-
Fischer, T.1
Gemeinhardt, I.2
Wagner, S.3
Stieglitz, D.V.4
Schnorr, J.5
Hermann, K.-G.A.6
-
22
-
-
0037423638
-
Poly (vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography
-
Kharine A., Manohar S., Seeton R., Kolkman R.G., Bolt R.A., Steenbergen W., et al. Poly (vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography. Phys Med Biol 2003, 48(3):357.
-
(2003)
Phys Med Biol
, vol.48
, Issue.3
, pp. 357
-
-
Kharine, A.1
Manohar, S.2
Seeton, R.3
Kolkman, R.G.4
Bolt, R.A.5
Steenbergen, W.6
-
23
-
-
0011034973
-
-
(Dec 10, 2014)
-
Oregon Medical Laser Center Optical absorption of methylene blue 2014, 〈http://omlc.org/spectra/mb/index.html〉 (Dec 10, 2014).
-
(2014)
Optical absorption of methylene blue
-
-
-
24
-
-
0017263577
-
Light-absorbing properties, stability, and spectral stabilization of indocyanine green
-
Landsman M., Kwant G., Mook G., Zijlstra W: Light-absorbing properties, stability, and spectral stabilization of indocyanine green. J Appl Physiol 1976, 40(4):575-583.
-
(1976)
J Appl Physiol
, vol.40
, Issue.4
, pp. 575-583
-
-
Landsman, M.1
Kwant, G.2
Mook, G.3
Zijlstra, W.4
|