메뉴 건너뛰기




Volumn 11, Issue 4, 2016, Pages 621-633

A fast, accurate and closed-form method for pose recognition of an intramedullary nail using a tracked C-arm

Author keywords

C arm; IM nail; Pose estimation; Pose recognition; Radiation

Indexed keywords

ACCURACY; ARTICLE; AUTOMATION; INTRAMEDULLARY NAIL; INTRAMEDULLARY NAILING; MATHEMATICAL ANALYSIS; MATHEMATICAL COMPUTING; MATHEMATICAL MODEL; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; RELIABILITY; X RAY; X RAY DETECTOR; ALGORITHM; BONE SCREW; COMPUTER ASSISTED SURGERY; DEVICES; DIAGNOSTIC IMAGING; EQUIPMENT DESIGN; FLUOROSCOPY; FRACTURES, BONE; HUMAN; IMAGE PROCESSING; PROCEDURES; REPRODUCIBILITY;

EID: 84944706850     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-015-1294-y     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 34547247781 scopus 로고    scopus 로고
    • Intramedullary nail distal hole axis estimation using blob analysis and Hough transform. In: IEEE conference on robotics, automation and mechatronics
    • Neatpisarnvanit C, Suthakorn J (2006) Intramedullary nail distal hole axis estimation using blob analysis and Hough transform. In: IEEE conference on robotics, automation and mechatronics. doi:10.1109/RAMECH.2006.252685
    • (2006) doi:10.1109/RAMECH.2006.252685
    • Neatpisarnvanit, C.1    Suthakorn, J.2
  • 2
    • 0032127086 scopus 로고    scopus 로고
    • Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing
    • COI: 1:STN:280:DyaK1M%2FjtFanug%3D%3D, PID: 9813705
    • Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM (1998) Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29:461–468
    • (1998) Injury , vol.29 , pp. 461-468
    • Muller, L.P.1    Suffner, J.2    Wenda, K.3    Mohr, W.4    Rommens, P.M.5
  • 4
  • 5
    • 0037403882 scopus 로고    scopus 로고
    • Experimental model for a new distal locking aiming device for solid intramedullary tibia nails
    • PID: 12719165
    • Abdlslam KM, Bonnaire F (2003) Experimental model for a new distal locking aiming device for solid intramedullary tibia nails. Injury 34:363–6
    • (2003) Injury , vol.34 , pp. 363-366
    • Abdlslam, K.M.1    Bonnaire, F.2
  • 6
    • 0034868609 scopus 로고    scopus 로고
    • Recovery of distal hole axis in intramedullary nail trajectory planning. In: International conference on robotics and automation
    • Zhu Y, Phillips R, Griffiths JG, Viant W, Mohsen A, Bielby M (2001) Recovery of distal hole axis in intramedullary nail trajectory planning. In: International conference on robotics and automation, pp 1561–1566
    • (2001) pp 1561–1566
    • Zhu, Y.1    Phillips, R.2    Griffiths, J.G.3    Viant, W.4    Mohsen, A.5    Bielby, M.6
  • 8
    • 0034463546 scopus 로고    scopus 로고
    • Surgical navigation based on fluoroscopy-clinical application for computer-assisted distal locking of intramedullary implants
    • Suhm N, Jacob AL, Nolte LP, Regazzoni P, Messmer P (2000) Surgical navigation based on fluoroscopy-clinical application for computer-assisted distal locking of intramedullary implants. Comput Aided Surg 5:391–400. doi:10.1002/igs.1001
    • (2000) Comput Aided Surg , vol.5 , pp. 391-400
    • Suhm, N.1    Jacob, A.L.2    Nolte, L.P.3    Regazzoni, P.4    Messmer, P.5
  • 9
    • 54449098074 scopus 로고    scopus 로고
    • A novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation
    • PID: 18779062
    • Leloup T, El Kazzi W, Schuind F, Warzée N (2008) A novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation. IEEE Trans Med Imaging 27:1202–1212. doi:10.1109/TMI.2008.920602
    • (2008) IEEE Trans Med Imaging , vol.27 , pp. 1202-1212
    • Leloup, T.1    El Kazzi, W.2    Schuind, F.3    Warzée, N.4
  • 10
    • 41649094815 scopus 로고    scopus 로고
    • A robust and accurate two-stage approach for automatic recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures
    • PID: 18334439
    • Zheng G, Zhang X, Haschtmann D, Gedet P, Dong X, Nolte LP (2008) A robust and accurate two-stage approach for automatic recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures. IEEE Trans Med Imaging 27:171–187. doi:10.1109/TMI.2007.904692
    • (2008) IEEE Trans Med Imaging , vol.27 , pp. 171-187
    • Zheng, G.1    Zhang, X.2    Haschtmann, D.3    Gedet, P.4    Dong, X.5    Nolte, L.P.6
  • 11
    • 84880140503 scopus 로고    scopus 로고
    • The insertion of intramedullary nail locking screws without fluoroscopy: a faster and safer technique
    • PID: 23287748
    • Chan DS, Burris RB, Erdogan M, Sagi HC (2013) The insertion of intramedullary nail locking screws without fluoroscopy: a faster and safer technique. J Orthop Trauma 27:363–366. doi:10.1097/BOT.0b013e3182828e10
    • (2013) J Orthop Trauma , vol.27 , pp. 363-366
    • Chan, D.S.1    Burris, R.B.2    Erdogan, M.3    Sagi, H.C.4
  • 13
    • 23944475576 scopus 로고    scopus 로고
    • Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty
    • PID: 16103862
    • Harstall R, Heini PF, Mini RL, Orler R (2005) Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty. Spine 30:1893–1898
    • (2005) Spine , vol.30 , pp. 1893-1898
    • Harstall, R.1    Heini, P.F.2    Mini, R.L.3    Orler, R.4
  • 14
    • 84908545027 scopus 로고    scopus 로고
    • A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging
    • Amiri S, Wilson DR, Masri BA, Anglin C (2013) A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging. Int J Comput Assist Radiol Surg 9:695–711. doi:10.1007/s11548-013-0957-9
    • (2013) Int J Comput Assist Radiol Surg , vol.9 , pp. 695-711
    • Amiri, S.1    Wilson, D.R.2    Masri, B.A.3    Anglin, C.4
  • 15
    • 84962254336 scopus 로고
    • Method and means for recognizing complex patterns. Haugh PVC, Arbor A, Assignee. Patent US3069654 A
    • Hough PVC, Arbor A (1962) Method and means for recognizing complex patterns. Haugh PVC, Arbor A, Assignee. Patent US3069654 A. 25 Mar 1960
    • (1962) 25 Mar , pp. 1960
    • Hough, P.V.C.1    Arbor, A.2
  • 16
    • 0015285440 scopus 로고
    • Use of the Hough transformation to detect lines and curves in pictures
    • Duda RO, Hart PE (1972) Use of the Hough transformation to detect lines and curves in pictures. Commun ACM 15:11–15. doi:10.1145/361237.361242
    • (1972) Commun ACM , vol.15 , pp. 11-15
    • Duda, R.O.1    Hart, P.E.2
  • 17
    • 84975553202 scopus 로고
    • Closed-form solution of absolute orientation using unit quaternions
    • Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am 4:629–642
    • (1987) J Opt Soc Am , vol.4 , pp. 629-642
    • Horn, B.K.P.1
  • 18
    • 79951722063 scopus 로고    scopus 로고
    • Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components
    • PID: 21092967
    • Acker S, Li R, Murray H, John PS, Banks S, Mu S, Wyss U, Deluzio K (2011) Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components. J Biomech 44:784–7. doi:10.1016/j.jbiomech.2010.10.033
    • (2011) J Biomech , vol.44 , pp. 784-787
    • Acker, S.1    Li, R.2    Murray, H.3    John, P.S.4    Banks, S.5    Mu, S.6    Wyss, U.7    Deluzio, K.8
  • 19
    • 0344012667 scopus 로고    scopus 로고
    • A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images
    • PID: 14649746
    • Mahfouz MR, Hoff WA, Komistek RD, Dennis DA (2003) A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging 22:1561–1574. doi:10.1109/TMI.2003.820027
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 1561-1574
    • Mahfouz, M.R.1    Hoff, W.A.2    Komistek, R.D.3    Dennis, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.