메뉴 건너뛰기




Volumn 23, Issue 6, 2016, Pages 1457-1466

The performance of quantitation methods in the evaluation of cardiac implantable electronic device (CIED) infection: A technical review

Author keywords

fluorodeoxyglucose (FDG); inflammation; PET CT imaging

Indexed keywords

FLUORODEOXYGLUCOSE F 18; RADIOPHARMACEUTICAL AGENT;

EID: 84944704859     PISSN: 10713581     EISSN: 15326551     Source Type: Journal    
DOI: 10.1007/s12350-015-0106-7     Document Type: Article
Times cited : (27)

References (19)
  • 1
    • 80052087661 scopus 로고    scopus 로고
    • 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States: 1993 to 2008
    • PID: 21867833
    • Greenspon AJ, Patel JD, Lau E, Ochoa JA, Frisch DR, Ho RT, et al. 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States: 1993 to 2008. J Am Coll Cardiol 2011;58:1001-6.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1001-1006
    • Greenspon, A.J.1    Patel, J.D.2    Lau, E.3    Ochoa, J.A.4    Frisch, D.R.5    Ho, R.T.6
  • 2
    • 77950508753 scopus 로고    scopus 로고
    • Continued rise in rates of cardiovascular implantable electronic device infections in the United States: Temporal trends and causative insights
    • PID: 19793359
    • Voigt A, Shalaby A, Saba S. Continued rise in rates of cardiovascular implantable electronic device infections in the United States: Temporal trends and causative insights. Pacing Clin Electrophysiol 2010;33:414-9.
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 414-419
    • Voigt, A.1    Shalaby, A.2    Saba, S.3
  • 3
    • 73849120250 scopus 로고    scopus 로고
    • Contemporary management of and outcomes from cardiac device related infections
    • PID: 19910314
    • Margey R, McCann H, Blake G, Keelan E, Galvin J, Lynch M, et al. Contemporary management of and outcomes from cardiac device related infections. Europace 2010;12:64-70.
    • (2010) Europace , vol.12 , pp. 64-70
    • Margey, R.1    McCann, H.2    Blake, G.3    Keelan, E.4    Galvin, J.5    Lynch, M.6
  • 4
    • 84863955026 scopus 로고    scopus 로고
    • Infections of implantable cardiac rhythm devices: Predisposing factors and outcome
    • PID: 22870738
    • Ipek EG, Guray U, Demirkan B, Guray Y, Aksu T. Infections of implantable cardiac rhythm devices: Predisposing factors and outcome. Acta Cardiol 2012;67:303-10.
    • (2012) Acta Cardiol , vol.67 , pp. 303-310
    • Ipek, E.G.1    Guray, U.2    Demirkan, B.3    Guray, Y.4    Aksu, T.5
  • 5
    • 84862264422 scopus 로고    scopus 로고
    • Long-term mortality after transvenous lead extraction
    • COI: 1:CAS:528:DC%2BC38Xpt1yrsL0%3D, PID: 22362891
    • Maytin M, Jones SO, Epstein LM. Long-term mortality after transvenous lead extraction. Circulation 2012;5:252-7.
    • (2012) Circulation , vol.5 , pp. 252-257
    • Maytin, M.1    Jones, S.O.2    Epstein, L.M.3
  • 7
    • 84855478171 scopus 로고    scopus 로고
    • Positron emission tomography in patients with suspected pacing system infections may play a critical role in difficult cases
    • PID: 21463705
    • Ploux S, Riviere A, Amraoui S, Whinnett Z, Barandon L, Lafitte S, et al. Positron emission tomography in patients with suspected pacing system infections may play a critical role in difficult cases. Heart Rhythm 2011;8:1478-81.
    • (2011) Heart Rhythm , vol.8 , pp. 1478-1481
    • Ploux, S.1    Riviere, A.2    Amraoui, S.3    Whinnett, Z.4    Barandon, L.5    Lafitte, S.6
  • 8
    • 84860305844 scopus 로고    scopus 로고
    • Imaging for infected cardiac implantable electronic devices: A new trick for your pet
    • PID: 22538332
    • Brinker J. Imaging for infected cardiac implantable electronic devices: A new trick for your pet. J Am Coll Cardiol 2012;59:1626-8.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1626-1628
    • Brinker, J.1
  • 9
    • 79959296181 scopus 로고    scopus 로고
    • Whole body [(18)F]fluorodeoxyglucose positron emission tomography imaging for the diagnosis of pacemaker or implantable cardioverter defibrillator infection: A preliminary prospective study
    • COI: 1:STN:280:DC%2BC3MnhsVSmtg%3D%3D, PID: 20636421
    • Bensimhon L, Lavergne T, Hugonnet F, Mainardi JL, Latremouille C, Maunoury C, et al. Whole body [(18)F]fluorodeoxyglucose positron emission tomography imaging for the diagnosis of pacemaker or implantable cardioverter defibrillator infection: A preliminary prospective study. Clin Microbiol Infect 2011;17:836-44.
    • (2011) Clin Microbiol Infect , vol.17 , pp. 836-844
    • Bensimhon, L.1    Lavergne, T.2    Hugonnet, F.3    Mainardi, J.L.4    Latremouille, C.5    Maunoury, C.6
  • 10
    • 84860299779 scopus 로고    scopus 로고
    • Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections
    • PID: 22538331
    • Sarrazin J-F, Philippon F, Tessier M, Guimond J, Molin F, Champagne J, et al. Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections. J Am Coll Cardiol 2012;59:1616-25.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1616-1625
    • Sarrazin, J.-F.1    Philippon, F.2    Tessier, M.3    Guimond, J.4    Molin, F.5    Champagne, J.6
  • 11
    • 84879730893 scopus 로고    scopus 로고
    • Diagnostic yield of FDG positron-emission tomography/computed tomography in patients with CEID infection: a pilot study
    • PID: 23148119
    • Cautela J, Alessandrini S, Cammilleri S, Giorgi R, Richet H, Casalta JP, et al. Diagnostic yield of FDG positron-emission tomography/computed tomography in patients with CEID infection: a pilot study. Europace 2013;15:252-7.
    • (2013) Europace , vol.15 , pp. 252-257
    • Cautela, J.1    Alessandrini, S.2    Cammilleri, S.3    Giorgi, R.4    Richet, H.5    Casalta, J.P.6
  • 12
    • 84939470843 scopus 로고    scopus 로고
    • Metal artefact reduction algorithms prevent false positive results when assessing patients for cardiac implantable electronic device infection
    • PID: 25112539
    • Ahmed FZ, James J, Tout D, Arumugam P, Mamas M, Zaidi AM. Metal artefact reduction algorithms prevent false positive results when assessing patients for cardiac implantable electronic device infection. J Nucl Cardiol 2014;22:219-20.
    • (2014) J Nucl Cardiol , vol.22 , pp. 219-220
    • Ahmed, F.Z.1    James, J.2    Tout, D.3    Arumugam, P.4    Mamas, M.5    Zaidi, A.M.6
  • 13
    • 84858689008 scopus 로고    scopus 로고
    • Member S. Clough-Tocher interpolation of virtual sinogram in a Delaunay triangulated grid for metal artifact reduction of PET/CT images
    • Abdoli M, De R, Dierckx RAO, Zaidi H, Member S. Clough-Tocher interpolation of virtual sinogram in a Delaunay triangulated grid for metal artifact reduction of PET/CT images. 2011 IEEE nuclear science symposium and medical imaging conference (NSS/MIC); 2011. p. 3197-3201.
    • (2011) IEEE nuclear science symposium and medical imaging conference (NSS/MIC) , vol.2011 , pp. 3197-3201
    • Abdoli, M.1    De, R.2    Dierckx, R.A.O.3    Zaidi, H.4
  • 14
    • 70349753332 scopus 로고    scopus 로고
    • Report on the first international workshop on Interim-PET-scan in lymphoma
    • PID: 19544140
    • Meignan M, Gallamini A, Haioun C. Report on the first international workshop on Interim-PET-scan in lymphoma. Leuk Lymphoma 2009;50:1257-60.
    • (2009) Leuk Lymphoma , vol.50 , pp. 1257-1260
    • Meignan, M.1    Gallamini, A.2    Haioun, C.3
  • 15
    • 66149139452 scopus 로고    scopus 로고
    • From RECIST to PERCIST: Evolving considerations for PET response criteria in solid tumors
    • COI: 1:CAS:528:DC%2BD1MXmtFahtr8%3D, PID: 19403881
    • Wahl RL, Jacene H, Kasamon Y, Lodge MA. From RECIST to PERCIST: Evolving considerations for PET response criteria in solid tumors. J Nucl Med 2009;50:122S-50S.
    • (2009) J Nucl Med , vol.50 , pp. 122S-150S
    • Wahl, R.L.1    Jacene, H.2    Kasamon, Y.3    Lodge, M.A.4
  • 16
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • COI: 1:STN:280:DyaL1M%2Fns12ksQ%3D%3D, PID: 3203132
    • DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach. Biometrics 1988;44:837-45.
    • (1988) Biometrics , vol.44 , pp. 837-845
    • DeLong, E.R.1    DeLong, D.M.2    Clarke-Pearson, D.L.3
  • 17
    • 48249153186 scopus 로고
    • Intraclass correlations: Uses in assessing rater reliability
    • COI: 1:STN:280:DC%2BD1cnkslSnsg%3D%3D, PID: 18839484
    • Shrout PE, Fliess JL. Intraclass correlations: Uses in assessing rater reliability. Psychol Bull 1979;86:420-8.
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fliess, J.L.2
  • 19
    • 84901648040 scopus 로고    scopus 로고
    • Cardiovascular implantable electronic device infection: Delayed vs standard FDG PET-CT imaging
    • PID: 24715624
    • Leccisotti L, Perna F, Lago M, Leo M, Stefanelli A, Calcagni ML, et al. Cardiovascular implantable electronic device infection: Delayed vs standard FDG PET-CT imaging. J Nucl Cardiol 2014;21:622-32.
    • (2014) J Nucl Cardiol , vol.21 , pp. 622-632
    • Leccisotti, L.1    Perna, F.2    Lago, M.3    Leo, M.4    Stefanelli, A.5    Calcagni, M.L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.