메뉴 건너뛰기




Volumn 51, Issue , 2015, Pages 728-731

Use of 3D printed materials as tissue-equivalent phantoms

Author keywords

Lung phantom; Radiation therapy; Rapid prototyping

Indexed keywords

BIOLOGICAL ORGANS; BIOMEDICAL ENGINEERING; COMPUTERIZED TOMOGRAPHY; DOSIMETRY; PRINTING; RADIOTHERAPY; RAPID PROTOTYPING; STYRENE; TISSUE;

EID: 84944329595     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-319-19387-8_179     Document Type: Conference Paper
Times cited : (48)

References (13)
  • 2
    • 33846437062 scopus 로고    scopus 로고
    • Percutaneous Pulmonary Valve Implantation Based on Rapid Prototyping of Right Ventricular Outflow Tract and Pulmonary Trunk from MR Data
    • Schievano S, Migliavacca F, Coats L, et al. (2007) Percutaneous Pulmonary Valve Implantation Based on Rapid Prototyping of Right Ventricular Outflow Tract and Pulmonary Trunk from MR Data. Radiol. 242(2):490-497
    • (2007) Radiol , vol.242 , Issue.2 , pp. 490-497
    • Schievano, S.1    Migliavacca, F.2    Coats, L.3
  • 4
    • 73749085335 scopus 로고    scopus 로고
    • A review of the issues surrounding three-dimensional computed tomography for medical modelling using rapid prototyping techniques
    • Bibb R, Winder J (2010). A review of the issues surrounding three-dimensional computed tomography for medical modelling using rapid prototyping techniques. Radiogr. 16(1):78-83
    • (2010) Radiogr , vol.16 , Issue.1 , pp. 78-83
    • Bibb, R.1    Winder, J.2
  • 5
    • 80053594394 scopus 로고    scopus 로고
    • Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison
    • Harrison K M, Ebert M A, Kron T, et al. (2011). Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison. Med. Phys. 38(10):5330-5337
    • (2011) Med. Phys , vol.38 , Issue.10 , pp. 5330-5337
    • Harrison, K.M.1    Ebert, M.A.2    Kron, T.3
  • 6
    • 33646894079 scopus 로고    scopus 로고
    • Physical phantom of typical Korean male for radiation protection purpose
    • Kim J I, Choi H, Lee B I, et al. (2006). Physical phantom of typical Korean male for radiation protection purpose. Radiat. Prot. Dosim. 118(1):131-136
    • (2006) Radiat. Prot. Dosim , vol.118 , Issue.1 , pp. 131-136
    • Kim, J.I.1    Choi, H.2    Lee, B.I.3
  • 7
    • 55649104197 scopus 로고    scopus 로고
    • Dimensional accuracy of the skull models produced by rapid prototyping technology using stereolithography apparatus
    • Nizam A, Gopal R N, Naing L, et al. (2006). Dimensional accuracy of the skull models produced by rapid prototyping technology using stereolithography apparatus. Orofac. Sci. 1:60-66
    • (2006) Orofac. Sci. , vol.1 , pp. 60-66
    • Nizam, A.1    Gopal, R.N.2    Naing, L.3
  • 8
    • 84965095014 scopus 로고    scopus 로고
    • Design and production of 3D printed bolus for electron radiation therapy
    • Su S, Moran K, Robar J L. (2013). Design and production of 3D printed bolus for electron radiation therapy. J. Appl. clin. Med. Phys. 15(4):4831-4831
    • (2013) J. Appl. Clin. Med. Phys , vol.15 , Issue.4
    • Su, S.1    Moran, K.2    Robar, J.L.3
  • 9
    • 34447325660 scopus 로고    scopus 로고
    • Design, development, and implementation of the radiological physics center’s pelvis and thorax anthropomorphic quality assurance phantoms
    • Followill D S, Evans D R, Cherry C, et al. (2007). Design, development, and implementation of the radiological physics center’s pelvis and thorax anthropomorphic quality assurance phantoms. Med. Phys. 34(6):2070-2076
    • (2007) Med. Phys , vol.34 , Issue.6 , pp. 2070-2076
    • Followill, D.S.1    Evans, D.R.2    Cherry, C.3
  • 10
    • 0037572347 scopus 로고    scopus 로고
    • CERR: A computational environment for radiotherapy research
    • Deasy J O, Blanco A I, Clark V H. (2003) CERR: a computational environment for radiotherapy research. Med. Phys. 30:979–985
    • (2003) Med. Phys , vol.30 , pp. 979-985
    • Deasy, J.O.1    Blanco, A.I.2    Clark, V.H.3
  • 11
    • 84867140087 scopus 로고    scopus 로고
    • 3D Slicer as an Image Computing Platform for the Quantitative Imaging Network
    • Fedorov A, Beichel R, Kalpathy-Cramer J, et al. (2012) 3D Slicer as an Image Computing Platform for the Quantitative Imaging Network. Magn. Reson. Imaging. 30(9):1323-1341
    • (2012) Magn. Reson. Imaging , vol.30 , Issue.9 , pp. 1323-1341
    • Fedorov, A.1    Beichel, R.2    Kalpathy-Cramer, J.3
  • 12
    • 78049427805 scopus 로고    scopus 로고
    • Local heterogeneities in early batches of EBT2 film: A suggested solution
    • Kairn T, Aland T, Kenny J. (2010) Local heterogeneities in early batches of EBT2 film: A suggested solution. Phys. Med. Biol. 55(15):L37-L42
    • (2010) Phys. Med. Biol , vol.55 , Issue.15 , pp. L37-L42
    • Kairn, T.1    Aland, T.2    Kenny, J.3
  • 13
    • 80051700455 scopus 로고    scopus 로고
    • Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    • Aland T, Kairn T, Kenny J. (2011) Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance. Australas. Phys. Eng. Sci. Med. 34(2):251-260
    • (2011) Australas. Phys. Eng. Sci. Med , vol.34 , Issue.2 , pp. 251-260
    • Aland, T.1    Kairn, T.2    Kenny, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.