메뉴 건너뛰기




Volumn , Issue , 2008, Pages

Developmentof asimulation model for secondary control performance assessment with significant wind power in amarket environment

Author keywords

Automatic Generation Control; Dynamic simulation; Frequency stability; Secondary control; System integration; Wind power

Indexed keywords

AUTOMATIC PROGRAMMING; COMMERCE; COMPUTER SIMULATION; DYNAMICS; ELECTRIC POWER SYSTEMS; FREQUENCY STABILITY; REAL TIME SYSTEMS; WIND POWER;

EID: 84944104269     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (5)

References (19)
  • 1
    • 0032206595 scopus 로고    scopus 로고
    • Automatic generation control in a deregulated power system
    • Nov.
    • B. H. Bakken and O. S. Grande, "Automatic Generation Control in a Deregulated Power System", IEEE Transactions on Power Systems, vol. 13, no. 4, pp. 1401-1406, Nov. 1998.
    • (1998) IEEE Transactions on Power Systems , vol.13 , Issue.4 , pp. 1401-1406
    • Bakken, B.H.1    Grande, O.S.2
  • 3
    • 33751376097 scopus 로고    scopus 로고
    • Integration of wind power in the liberalized Dutch electricity market
    • March Nov.-Dec.
    • B. C. Ummels, M. Gibescu, W. L. Kling, and G. C. Paap, "Integration of Wind Power in the Liberalized Dutch Electricity Market", Wind Energy, no. 6, pp. 579-590, March Nov.-Dec. 2006.
    • (2006) Wind Energy , Issue.6 , pp. 579-590
    • Ummels, B.C.1    Gibescu, M.2    Kling, W.L.3    Paap, G.C.4
  • 4
    • 0038180775 scopus 로고    scopus 로고
    • Is NETA the blueprint for wholesale electricity trading arrangements of the future?
    • May
    • S. Hesmondhalgh, "Is NETA the Blueprint for Wholesale Electricity Trading Arrangements of the Future?" IEEE Transactions on Power Systems, vol. 18, no. 2, pp. 548-554, May 2003.
    • (2003) IEEE Transactions on Power Systems , vol.18 , Issue.2 , pp. 548-554
    • Hesmondhalgh, S.1
  • 6
    • 28244449042 scopus 로고    scopus 로고
    • Frequency control and wind turbine technologies
    • Nov.
    • G. Lalor, A. Mullane, and M. J. O'Malley, "Frequency Control and Wind Turbine Technologies", IEEE Transactions on Power Systems, vol. 20, no. 4, pp. 1905-1913, Nov. 2005.
    • (2005) IEEE Transactions on Power Systems , vol.20 , Issue.4 , pp. 1905-1913
    • Lalor, G.1    Mullane, A.2    O'Malley, M.J.3
  • 7
    • 4043137869 scopus 로고    scopus 로고
    • A methodology for the redesign of frequency control for AC networks
    • Aug.
    • G. A. Chown and B. Wigdorowitz, "A Methodology for the Redesign of Frequency control for AC Networks", IEEE Transactions on Power Systems, vol. 19, no. 3, pp. 1546-1554, Aug. 2004.
    • (2004) IEEE Transactions on Power Systems , vol.19 , Issue.3 , pp. 1546-1554
    • Chown, G.A.1    Wigdorowitz, B.2
  • 8
    • 77954004858 scopus 로고    scopus 로고
    • Operation handbook, appendix 1: Load-frequency control and performance
    • Tech. Rep.
    • UCTE, "Operation Handbook, Appendix 1: Load-Frequency Control and Performance", Union for the Co-ordination of Transmission of Electricity, Tech. Rep., 2004. [Online]. Available: http://www.ucte.org/ohb/curstatus.asp
    • (2004) Union for the Co-ordination of Transmission of Electricity
    • UCTE1
  • 12
    • 0025471860 scopus 로고
    • A low-order system frequency response model
    • Aug.
    • P. M. Anderson and M. Mirheydar, "A Low-Order System Frequency Response Model", IEEE Transactions on Power Systems, vol. 5, no. 3, pp. 720-729, Aug. 1990.
    • (1990) IEEE Transactions on Power Systems , vol.5 , Issue.3 , pp. 720-729
    • Anderson, P.M.1    Mirheydar, M.2
  • 15
    • 0015602387 scopus 로고
    • Automatic generation control part I - Process modeling
    • F. P. de Mello, R. J. Mills, and W. F. B'Rells, "Automatic Generation Control Part I - Process Modeling", IEEE Transactions on Power Systems, vol. PAS-92, no. 2, pp. 710-715, 1973.
    • (1973) IEEE Transactions on Power Systems , vol.PAS-92 , Issue.2 , pp. 710-715
    • De Mello, F.P.1    Mills, R.J.2    B'Rells, W.F.3
  • 16
    • 0025594779 scopus 로고
    • Small and medium size boiler models suitable for long term dynamic response
    • Dec.
    • E. Cheres, "Small and Medium Size Boiler Models suitable for Long Term Dynamic Response", IEEE Transactions on Energy Conversion, vol. 5, no. 4, pp. 686-692, Dec. 1990.
    • (1990) IEEE Transactions on Energy Conversion , vol.5 , Issue.4 , pp. 686-692
    • Cheres, E.1
  • 17
    • 0034430607 scopus 로고    scopus 로고
    • A model of fossil fueled plant with once-through boiler for power system frequency simulation studies
    • Nov.
    • T. Inoue, H. Taniguchi, and Y. Ikeguchi, "A Model of Fossil Fueled Plant with Once-Through Boiler for Power System Frequency Simulation Studies", IEEE Transactions on Power Systems, vol. 15, no. 4, pp. 1322-1328, Nov. 2000.
    • (2000) IEEE Transactions on Power Systems , vol.15 , Issue.4 , pp. 1322-1328
    • Inoue, T.1    Taniguchi, H.2    Ikeguchi, Y.3
  • 19
    • 46149112360 scopus 로고    scopus 로고
    • Statistical wind speed interpolation for simulating aggregated wind power production under unit commitment and dispatch
    • Stockholm, Sweden, June 11-15
    • M. Gibescu, B. C. Ummels, and W. L. Kling, "Statistical Wind Speed Interpolation for Simulating Aggregated Wind Power Production under Unit Commitment and Dispatch", in Proc. 9th International Conference on Probabilistic Methods Applied to Power Systems, Stockholm, Sweden, June 11-15 2006, p. 7.
    • (2006) Proc. 9th International Conference on Probabilistic Methods Applied to Power Systems , pp. 7
    • Gibescu, M.1    Ummels, B.C.2    Kling, W.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.